• Title/Summary/Keyword: 포화지수

Search Result 210, Processing Time 0.026 seconds

The Role of Jugular Venous Oxyhemoglobin Saturation Monitoring During Cardic Surgery (개심술 중 경정맥 산소포화도의 역할)

  • Kim, Sae-Yeon;Jee, Dae-Lim
    • Journal of Yeungnam Medical Science
    • /
    • v.11 no.1
    • /
    • pp.49-54
    • /
    • 1994
  • Postoperative brain damage is one of most serious complications of cardiopulmonary bypass (CPB). To prevent brain damage during CPB, adequate cerebral perfusion for cerebral oxygen demand should be maintained. This study monitored jugular venous oxyhemoglobin saturation ($SjO_2$), which reflects the overall balance of cerebral oxygen supply and demand, intermittently in 10 patients undergoing cardiac surgery. At the initiation of CPB, in spite of a significant decrease in mean arterial pressure, $SjO_2$ did not change, and it was stable during the hypothermic period of CPB. But a significan reduction in $SjO_2$ was observed during the rewarming period, and $SjO_2$ had an inverse linear correlation with esophageal temperature. Furthermore, the percent decrease of $SjO_2$ was related to rewarming speed. Therefore, therapeutic approaches for $SjO_2$ desaturation include slower rewarming, increasing cerebral blood flow, decreasing the cerebral metabolic rate for oxygen, increasing oxygen content, and increasing perfusion flow rate.

  • PDF

An Experimental Study on Effects of Density and Confining Pressure on the Elastic Modulus of Subgrade Soils (밀도와 구속압력이 노상토의 탄성계수에 미치는 영향에 관한 실험적 연구)

  • Kim, Soo Il;Kim, Moon Kyum;Yoo, Ji Hyeung;Kim, Chul Soo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.8 no.2
    • /
    • pp.33-40
    • /
    • 1988
  • In this study, effects of the density of soil and the confining pressure applied to the soil sample on the elastic moduli of subgrade soils are experimentally analyzed. Through investigation of subgrade materials of domestic expressways, five typical types of subgrade soils are selected for the experiments. A series of unconsolidated undrained triaxial tests is performed on samples prepared with various water contents and densities at the confining pressures of 1.02, 2.04, and $3.06kg/cm^2$. Initial tangent modulus is inferred from the unloading-reloading portion of the stress strain curve obtained during an individual loading-unloading-reloading test. As a result of the analysis, it is found that the effect of the confining pressure on the elastic modulus of subgrade material is well consistent with the equation proposed by Janbu, and that the elastic modulus can be related to the dry unit weight expressing the Janbu constants as exponentiial functions of it. It is also found that the water content has little effect on the elastic modulus for the samples with the degree of saturation less than 70%.

  • PDF

A Study on Adhesive Joints for Composite Driveshafts (복합재료 동력전달축의 접착조인트에 관한 연구)

  • 김진국;이대길;최진경;김일영
    • Composites Research
    • /
    • v.14 no.2
    • /
    • pp.13-21
    • /
    • 2001
  • Substituting composite structures for conventional metallic structures has many advantages because of higher specific stiffness and specific strength of composite materials. In this work, one-piece driveshafts composed of carbon/epoxy and glass/epoxy composites were designed and manufactured for a rear wheel drive automobile satisfying three design specifications, such as static torque transmission capability, torsional buckling and the fundamental natural bending frequency. Single lap adhesive joint was used to join the composite shaft and the aluminum yoke. The torque transmission capability of the adhesively bonded composite shaft was calculated with respect to bonding length and yoke thickness by finite element analysis and compared with the experimental result. Torque transmission capability was based on the Tsai-Wu failure index fur composite shaft and the failure model which incorporated the nonlinear mechanical behavior of aluminum yoke and epoxy adhesive. From the experiments and the finite element analyses, it was found that the static torque transmission capability of the composite driveshaft was highest at the critical yoke thickness, and saturated beyond the critical length. Also, it was found that the one-piece composite driveshaft had 40% weight saving effect compared with a conventional two-piece steel driveshaft.

  • PDF

A Digital Elevation Analysis : Sparially Distributed Flow Apportioning Algorithm (수치 고도 분석 : 분포형 흐름 분배 알고리즘)

  • Kim, Sang-Hyeon;Kim, Gyeong-Hyeon;Jeong, Seon-Hui
    • Journal of Korea Water Resources Association
    • /
    • v.34 no.3
    • /
    • pp.241-251
    • /
    • 2001
  • A flow determination algorithm is proposed for the distributed hydrologic model. The advantages of a single flow direction scheme and multiple flow direction schemes are selectively considered to address the drawbacks of existing algorithms. A spatially varied flow apportioning factor is introduced in order to accommodate the accumulated area from upslope cells. The channel initiation threshold area(CIT) concept is expanded and integrated into the spatially distributed flow apportioning algorithm in order to delineate a realistic channel network. An application of a field example suggests that the linearly distributed flow apportioning scheme provides some advantages over existing approaches, such as the relaxation of over-dissipation problems near channel cells, the connectivity feature of river cells, the continuity of saturated areas and the negligence of the optimization of few parameters in existing algorithms. The effects of grid sizes are explored spatially as well as statistically.

  • PDF

Effect of Carrier Gas Flow Rate on Magnetic Properties of Bi:YIG Films Deposited with Aerosol Deposition Method (에어로졸성막법에 의해 제작된 Bi:YIG 막에 미치는 에어로졸유량의 영향)

  • Shin, Kwang-Ho
    • Journal of the Korean Magnetics Society
    • /
    • v.18 no.1
    • /
    • pp.14-18
    • /
    • 2008
  • Bismuth-substituted yttrium iron garnet(Bi:YIG) films, which show excellent magnetic and magneto-optical properties as well as low optical losses by optimizing their deposition and post-annealing condition, have been attracting great attention in optical device research area. In this study, the Bi:YIG thick films were deposited with the aerosol deposition method for the final purpose of applying them to optical isolators. Since the aerosol deposition is based on the impact adhesion of sub-micrometer particles accelerated by a carrier gas to a substrate, the flow rate of carrier gas, which is in proportion to mechanically collision energy, should be treated as an important parameter. The Bi:YIG($Bi_{0.5}Y_{2.5}Fe_5O_{12}$) particles with $100{\sim}500$ nm in average diameter were carried and accelerated by nitrogen gas with the flow rate of 0.5 l/min${\sim}$10 l/min. The coercive force decreased from 51 Oe to 37 Oe exponentially with increasing gas flow rate. This is presumably due to the fact that the optimal collision energy results in reduction of impurity and pore, which makes the film to be soft magnetically. The saturation magnetization decreased due to crystallographical distortion of the film with increasing gas flow rate.

Annealing Effects of Amorphous Cores for the Application of Flux-gate Sensors (Flux-gate 센서용 비정질 코아의 열처리효과)

  • 김용준;손대락;손동환
    • Journal of the Korean Magnetics Society
    • /
    • v.11 no.3
    • /
    • pp.134-140
    • /
    • 2001
  • Flux-gate magnetometer was developed in 1930's, and it has been widely used for the low magnetic field measurements. In this work, we have employed amorphous ribbon 2714A produced by Allied Chem. Co. as sensor core material. To develop low noise, low power consumption, and high reliability flux-gate magnetometer, we have measured ac magnetic properties depending on the annealing conditions. As quenched state amorphous core shows high noise level and ac magnetic properties were changed under the condition of accelerated aging test, but amorphous ribbon, which was annealed under 350 $\^{C}$ during 1 hour, shows low noise level of 0.1 nT in the frequency range of dc∼10 Hz which was 10 times better than the as quenched amorphous ribbon. Under accelerated aging test, ac magnetic properties such as squareness and coercivity of the annealed samples show higher reliability and approached to a certain limiting value as exponential function. We can see that high reliability and low noise flux-gate magnetometer could be developed, if we consider this ac magnetic properties change in the sensor design.

  • PDF

Aanalysis the Structure of Heat Environment in Daegu Using Landsat-8 (Landsat-8을 활용한 대구시 열 환경구조 분석)

  • Kim, Jun Hyun;Choi, Jin Ho
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.32 no.4_1
    • /
    • pp.327-333
    • /
    • 2014
  • To improve thermal environments in urban area, the structural characteristic analysis of thermal environments of the certain area should be preceded to analyze and supplement its problems. With Landsat-8, we measured the centrality estimation, the distribution map, and the spatial statistical analysis of Daegu Metropolitan City in January and August, which of data applied in analyzing the structure of thermal environments following to its spatial property. The thermal infrared band of satellite images has been used to analyze the standard normal deviated scores, which extract the centrality, while the cluster map, based upon Local Local Moran's I, has composed for understanding the autocorrelation of local spatial within environment space structure. Understanding the distribution features as well as the pivot center of thermal environments with satellite images provides principle database for updating urban thermal environments' policies and plans; because those are reference materials that should have precedence over for diverse thermal environment policies.

Validation of the Complementary Relationship of Evapotranspiration Hypothesis Using In-situ Measurements (관측자료 기반의 용담댐 유역 증발산 보완관계 가설 검증)

  • Eunji Kim;Boosik Kang
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.264-264
    • /
    • 2023
  • 물순환 과정에서의 증발산은 장기적인 관점에서의 수자원 계획 수립 시 중요한 요소이다. 증발산은 기온, 상대습도, 일사량 등 기상학적 인자뿐만 아니라 증발표면, 식생분포 등 다양한 인자의 복합작용에 의해 일어나므로, 유역 단위에서 발생한 실제증발산(Actual evapotranspiration, AET)을 측정하기에는 기술적인 한계가 존재한다. 그러나 증발산 보완관계(Complementary relationship of evapotranspiration, CRE) 가설을 활용하면, 수문요소의 상호작용을 고려한 모델링을 거치지 않고도, 비교적 간단하게 AET를 추정할 수 있다. 본 연구는 증발산 관측자료를 기반으로 유역 단위에서의 CRE를 검증하고자 하며, 플럭스 타워 등 다양한 관측장비가 설치되어 있는 용담댐 시험유역을 대상유역으로 선정하였다. 용담댐 유역 내 산지에 위치한 덕유산 플럭스 타워에서 측정된 증발산을 AET로 보았으며, 유역 인근에 위치한 전주 기상관측소에서 측정되는 팬 증발량(Epan)을 잠재증발산량(Potential evapotranspiration, PET)으로 보았다. Epan 계측시, 증발팬의 가열 등 주변환경 변화로 인해 과다하게 추정되는 값을 보완하기 위해 FAO Penman-Monteith 식을 활용해 팬 증발량 보정계수(Coefficient of pan evaporation, kp)를 산정하여 적용하였다. 습윤증발산량(Wet evapotranspiration, WET)은 대기가 완전히 포화되었을 때 발생하는 증발산량으로, 댐 수표면에서 계측되는 수면증발량을 WET로 보았다. CRE 검증을 위해 AET와 PET를 각각 WET로 나누어 AET+와 PET+로 무차원화하였으며, 습윤지수(Moisture Index, MI)는 AET를 PET로 나누어 산정하였다. CRE 가설은 MI에 따른 AET+와 PET+가 서로 보완관계를 갖는다는 것인데, 용담댐 유역의 관측자료를 활용하여 CRE를 검증한 결과 AET+와 PET+ 간의 비대칭계수(b)가 1.23인 것으로 나타났다. 이 때의 평균제곱오차(MSE)는 0.599, 결정계수(R2)는 0.631로 나타나 CRE의 b가 적합하게 추정된 것으로 판단된다. 본 연구결과와 같이 검증된 CRE를 통해 증발산 관측지점이 없거나, 조밀하지 않은 유역의 AET를 간접추정할 수 있으며, 이를 활용해 보다 정확한 댐의 장기유출 모의와 용수공급계획 수립에 도움을 줄 수 있을 것으로 기대된다.

  • PDF

Effect of Confining Pressure, Temperature, and Porosity on Permeability of Daejeon Granite: Experimental Study (대전 화강암의 투수계수에 미치는 구속압, 온도, 공극률의 영향: 실험적 연구)

  • Donggil Lee;Seokwon Jeon
    • Tunnel and Underground Space
    • /
    • v.34 no.1
    • /
    • pp.71-87
    • /
    • 2024
  • In deep geological disposal of high-level radioactive waste, the surrounding rock at the immediate vicinity of the deposition hole may experience localized changes in permeability due to in-situ stress at depth, swelling pressure from resaturated bentonite buffer, and the heat generated from the decay of radioactive isotopes. In this study, experimental data on changes in permeability of granite, a promising candidate rock type in South Korea, were obtained by applying various confining pressures and temperature conditions expected in the actual disposal environment. By conducting the permeability test on KURT granite specimens under three or more hydrostatic pressure conditions, the relation in which the permeability decreases exponentially as the confining pressure increases was derived. The temperature-induced changes in permeability were found to be negligible at temperatures below the expected maximum of 90℃. In addition, by establishing a relation in which the initial permeability is proportional to the power of the initial porosity, it was possible to estimate permeability value for granite with a specific porosity under a certain confining pressure.

Cognitive Dysfunction in non-hypoxemic COPD Patients (저산소증을 동반하지 않는 만성폐쇄성폐질환 환자에서의 인지기능장애)

  • Kim, Woo Jin;Han, Seon-Sook;Park, Myoung-Ok;Lee, Seung-Joon;Kim, Seong Jae;Lee, Jung Hie
    • Tuberculosis and Respiratory Diseases
    • /
    • v.62 no.5
    • /
    • pp.382-388
    • /
    • 2007
  • Background: The cognitive function is impaired in patients with hypoxemic chronic obstructive pulmonary disease (COPD). However, there are conflicting results regarding the cognitive function in patients with non-hypoxemic COPD. COPD patients also have sleep disorders. This study examined the cognitive function in non-hypoxemic COPD patients, and nocturnal sleep was assessed in COPD patients with a cognitive dysfunction. Methods: Twenty-eight COPD patients (mean age, 70.7 years) with an oxygen saturation > 90%, and 33 healthy control subjects (mean age, 69.5 years) who had visited for a routine check-up were selected. The neurocognitive tests were performed using the Korean version of the Consortium to Establish a Registry for Alzheimer's Disease (CERAD-K) Neuropsychological Battery. Results: The scores of the word list recall test (p=0.03) and the word list recognition test (p=0.006) in the COPD group were significantly lower than those in the control group. Nine patients showed a significantly impaired cognitive function. Seven of these underwent polysomnography, which revealed apnea-hypopnea indices ${\geq}$ five per hour in five patients. The median oxygen desaturation index and median limb movement index were 3.6/h and 38.6/h, respectively. Conclusion: These results suggest that the verbal memory function is impaired in non-hypoxemic COPD patients. Six out of seven COPD patients with an impaired cognitive function had sleep disorders of sleep apnea and/or periodic limb movements during sleep.