• Title/Summary/Keyword: 포기조

Search Result 96, Processing Time 0.024 seconds

The Changes of Bacillus spp. in Municipal Wastewater Treatment Plant with B3 process. (B3 공법을 사용하는 하수종말처리장에서 Bacillus 속 세균의 변화)

  • 안태석;홍선희;김옥선;유재준;전선옥;최승익
    • Korean Journal of Microbiology
    • /
    • v.37 no.3
    • /
    • pp.209-213
    • /
    • 2001
  • By FISH and spore staining methods, the changes of Bacillus spp. numbers were investigated at municipal waste water treatment system, which operated with B3 process. Total bacterial numbers, which is the sum ofDAPI bound cells and numbers of spore, were ranged TEX>$3.2{\times}10^8 ~ 4.4{\times}10^8 $ cells/ml. The Bacilli numbers whichis the sum of probe S-G-Bacill-0597-a-A-22 bound cells and numbers of spore were from $0.3{\times}10^7 ~ 8.4{\times}10^7 $ cells/ml. The ratios of Bacillus sp. to total bacteria were ranged from 8 to 60%. Among 4 aeration tanks, thefirst tank had shown the highest proportions of Bacillus sp. And third and fourth tanks, the numbers of sporewere increasing.

  • PDF

Distribution and Characteristics of Culturable Airborne Bacteria and Fungi in Municipal Wastewater Treatment Plants (하수처리시설에서 배양 가능한 공기중 미생물의 분포 및 특성)

  • Park, Kyo-Nam;Koh, Ji-Yun;Jeong, Choon-Soo;Kim, Jong-Seol
    • Korean Journal of Microbiology
    • /
    • v.47 no.1
    • /
    • pp.38-49
    • /
    • 2011
  • Bioaerosols generated from wastewater treatment plants may create health risks for plant workers and nearby residents. To determine the levels of culturable airborne bacteria and fungi in bioaerosols, samples were seasonally collected above and near the aeration tanks of one feces-urine and three sewage treatment plants in Ulsan, Korea with an impaction-type sampler. In the feces-urine treatment plant, concentrations of heterotrophic bacteria were between $1.3({\pm}0.2){\times}10^3$ and $2.6({\pm}1.2){\times}10^4$ MPN/$m^3$ above the aeration tank and between $1.7({\pm}1.0){\times}10^2$ and $7.2({\pm}2.2){\times}10^3$ MPN/$m^3$ near the aeration tank. Coliform bacteria were detected both above and near the aeration tank. In cases of sewage treatment plant, the numbers of heterotrophic bacteria ranged from $1.9({\pm}1.2){\times}10^1$ to $1.8({\pm}1.2){\times}10^4$ MPN/$m^3$ above the aeration tank and from $5.0({\pm}2.8){\times}10^0$ to $6.6({\pm}2.0){\times}10^3$ MPN/$m^3$ near the aeration tank. At reference sites, the concentrations of heterotrophs in ambient air were measured between $7.0{\times}10^0$ and $2.7{\times}10^1$ MPN/$m^3$. When we isolated and tentatively identified heterotrophic bacteria, Pseudomonas luteola was the most dominant species in bioaerosols from wastewater treatment plants, whereas the most abundant one in reference samples was Micrococcus sp. When we measured fungal concentrations in bioaerosols, they were rather similar regardless of sampling locations and seasons, and such genera as Cladosporium, Alternaria, and Penicillium were commonly identified.

The Challenges and Prospects Regarding Acceptance and Renunciation of Succession on Civil Law (민법상 상속의 승인과 포기에 관한 과제와 전망)

  • Park, Jong-Ryoel
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2013.07a
    • /
    • pp.181-184
    • /
    • 2013
  • 우리 민법에 상속인이 민법 제1019조 제1항의 기간 내에 한정승인 또는 포기를 하지 아니한 때에는 단순승인을 한 것으로 본다고 하여 그동안 상속인들에게 지나치게 불리하다는 비판을 받아왔던 규정이 1998년 8월 27일 선고된 헌법재판소 결정(96헌가 22 등)에 의하여 헌법불합치결정을 받았다. 이에 따라 2002년 1월 14일 법률 제6591호로 공포 시행된 개정민법 제1019조 제3항으로 "민법 제1019조 제1항의 규정에 불구하고 상속인은 상속채무가 상속재산을 초과하는 사실을 중대한 과실 없이 제1항의 기간 내에 알지 못하고 단순승인을 한 경우에는 그 사실을 안 날부터 3월내에 한정승인을 할 수 있다."는 규정이 신설되었다. 그러나 민법 제1019조 제3항은 상속인들에게 구제의 길이 열리기는 하였으나 상속인의 보호가 제한적이고 상속인에게 한정승인만을 허용하고 상속포기의 선택을 제한하여 상속인의 승인 포기의 선택권행사에 문제가 있다고 본다. 따라서 이 논문에서는 상속의 승인과 포기에 관한 문제점을 검토해보고 상속인과 이해당사자들 간 모두에게 불리함이 없이 가장 공평하고 합리적인 개선방안을 제시하고자 한다.

  • PDF

Temperature Prediction for the Wastewater Treatment Process using Heat Transfer Model (열전달 모델을 이용한 폐수처리공정의 온도 예측)

  • Rho, Seung-Baik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.3
    • /
    • pp.1795-1800
    • /
    • 2014
  • The temperature change in the biologically activated sludge wastewater treatment process was predicted using the heat transfer model. All incoming and outgoing heats in wastewater treatment processes were considered. Incoming heats included the solar radiation heat, the heat from impeller mechanical energy, and the biochemical heat in the aeration process. Outgoing heats comprised the radiation heat from the waste itself, the heat of vaporization and surface aeration, the wind convection heat and the conduction heat between the surface and aerator. All heats were used as an input to the existing empirical heat transfer model. The heat transfer model of wastewater treatment processes is presented also. To test the validity of the heat transfer model, the operating conditions of the actual wastewater treatment plant were used. The temperatures were compared with the model temperatures. Model predictions were consistent within the $1.0^{\circ}C$.

Determination of Oxygen Transfer Characteristics (α, β and R) in an Aeration Basin at a Conventional Activated Sludge Wastewater Treatment Plant (활성슬러지 하수처리장 포기조내 산소 전달특성(α, β와 R)의 효율적 산정방안 개발)

  • Ko, Kwang Baik;Choi, Mee Young
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.14 no.4
    • /
    • pp.989-997
    • /
    • 1994
  • The major objective of this study is to develop an effective method to estimate ${\alpha}$ and ${\beta}$ in an aeration basin at a conventional activated sludge wastewater treatment plant. A series of unsteady state batch tests were simultaneously performed with clean water and mixed liquor in two batch reactors under identical operational conditions. Oxygen uptake rates (OURs) of the mixed liquor were measured during the tests. The results show that the OURs due to synthesis respiration and endogenous respiration were averaged about $17.96 mg/(l{\cdot}hr)$ and about $12.29mg/(l{\cdot}hr)$, respectively. The corresponding ${\alpha}$ and ${\beta}$ were ranged between 0.65 to 0.95, and between 0.88 to 0.93, respectively. Based on the overall experimental results, the proposed experimental test method and the proposed method for determination of ${\alpha}$ and ${\beta}$ are found to be relatively simple and easy to use in evaluating the characteristics of aeration systems.

  • PDF

Growth and Succession of Protozoa Population in the Activated Sludge Plant. (하수처리장의 원생동물 천이)

  • 이찬형;문경숙;진익렬
    • Microbiology and Biotechnology Letters
    • /
    • v.32 no.2
    • /
    • pp.158-165
    • /
    • 2004
  • This study concerns the succession process of protozoa populations in two activated sludge pilot plants. Protozoa populations with similar structures developed and succeeded each other in two plants. It was observed that initial sludge inoculum did not influence the protozoan composition but shorten the period of the plant stabilization. It seemed the protozoan in aeration tank was come from the influent. The composition of the influent sewage influenced the structure of protozoa in the pilot plants. The flagellates was very abundant during the initial starting phase. These rapidly decreased after growth peak. Then sarcodina, ciliates were increased in succession. In ciliates, free-swimming forms appeared at first and crawling forms and stalked forms were followed. After 36 days from the start, the sludge stabilization phase was characterized by a populations of ciliates dominated by stalked and crawling type and low value of effluent BOD was achieved.

Comparison of Metabolic Fingerprintings between Biofilm and Aeration Tanks of RABC System for Food Wastewater Treatment (식품폐수처리 RABC system의 생물막과 포기조 대사지문 비교)

  • Lee, Dong-Geun;Yoo, Ki-Hwan;Sung, Gi-Moon;Park, Seong-Joo;Lee, Jae-Hwa;Ha, Bae-Jin;Ha, Jong-Myung;Lee, Sang-Hyeon
    • Journal of Life Science
    • /
    • v.19 no.3
    • /
    • pp.349-355
    • /
    • 2009
  • Metabolic fingerprinting of microbial communities was investigated with Biolog GN2 plates using samples of biofilm and aeration tanks from an RABC (rotating activated Bacillus contactor) system - an advanced wastewater treatment system for the food wastewater of pig slaughterhouses. Aerobic and anaerobic results revealed the following four aspects. First, simple matching and pairs t-test of daily variation showed more defined qualitative and quantitative relatedness of active microbial communities than that of mere optical densities. Second, metabolic potentials were higher in biofilm than in aeration tanks (p<0.01), meaning higher activity of biofilm. Third, two aeration tanks showed the highest similarity (78%) and similar metabolic power (p=0.287). However, actively used carbon sources were different among samples, signifying change of active communities at each wastewater treatment step. Finally, aerobic and anaerobic metabolic fingerprinting patterns were different for the same samples representing activities of microaerophilic and/or anaerobic communities. These results suggest that daily variation and anaerobic incubation would help in the comparison of metabolic fingerprintings.

A Dynamic Simulation for Refinery Wastewater in Activated Sludge Treatment (활성슬러지법에서 정유폐수처리의 동역학적 Simulation)

  • Lee, Woo Bum;Kim, Jong O
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.11
    • /
    • pp.2017-2023
    • /
    • 2000
  • A dynamic model was applied to compare the environmental parameters and effluent characteristics of refinery wastewater in activated sludge treatment. The measured DO, pH, MLSS, and COD values were compared with the simulated their results in the activated sludge reactor. As results of simulation. good agreements between the measured and simulated results were investigated. The simulated and measured effluent COD were 19.0~19.4mg/L and 23.1mg/L. respectively. The simulated and measured DO were 1.9~2.4mg/L and 2.2mg/L. respectively.

  • PDF