• Title/Summary/Keyword: 폐구 인상

Search Result 7, Processing Time 0.024 seconds

Comparison of conventional and suction-effective complete denture in a fully edentulous patient: a case report (완전 무치악 환자에서 전통형 총의치와 흡착형 총의치 비교 증례)

  • Woong-Gi Han;Hong Seok Moon;Jaeyoung Kim
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.62 no.4
    • /
    • pp.366-374
    • /
    • 2024
  • In a completely edentulous patient who cannot have implant-retained overdentures due to medical history and economic circumstances, a suction-effective complete denture utilizing the closed-mouth impression technique is being used to secure high retention. In this case, both a conventional complete denture using the open-mouth impression technique and a suction-effective complete denture using the closed-mouth impression technique were fabricated for a single completely edentulous patient. The results demonstrated that both methods provided excellent outcomes in terms of function, esthetics, and patient satisfaction. Conventional complete dentures increase the area of denture-bearing pressure to ensure retention and stability, whereas suction-effective complete dentures achieve retention by sealing the entire border of the denture. Since there are characteristic differences in the clinical and laboratory procedures due to differences in the concept of denture fabrication, this was compared through this case report.

Complete denture rehabilitation of edentulous patient with severe alveolar bone resorption and condyle fracture using gothic arch tracing and closed mouth impression technique: A case report (하악 과두 골절과 심한 잔존치조제 흡수를 보이는 완전 무치악 환자에서 폐구 인상법과 고딕아치 묘기법을 이용한 총의치 수복 증례)

  • Choi, In-Ho;Kim, Seong-A;Kim, Na-Hong;Lee, Yong-Sang
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.2
    • /
    • pp.145-152
    • /
    • 2020
  • It is essential to record maxillomandibular relationship accurately for the harmony of esthetic and function in complete denture. Gothic arch tracing visually demonstrates the movement of the mandible, and is useful to establish accurate and reproducible centric relation. Proper retention and stability of complete denture in patients with severe alveolar bone resorption is difficult to attain. In such case, the closed mouth impression technique might be recommended. The denture border and impression are determined by patient's physiologic movement in the closed mouth impression technique. And, denture peripheral border is entirely closed with oral mucous membrane. This report presents satisfactory complete denture restoration using closed mouth impression technique and gothic arch tracing in patients with mandibular condyle fracture and severe absorption of mandibular alveolar ridge.

Implant overdenture with closed impression technique for patient with Myasthenia Gravis: A case report (중증 근무력증 환자에서 폐구 인상법을 이용한 임플란트 피개의치 수복 증례)

  • Park, Lydia;Park, Minhyuk;Park, Sangwon;Lim, Hyun-Pil;Jang, Woohyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.4
    • /
    • pp.459-468
    • /
    • 2021
  • In patients with myasthenia gravis, it is difficult to manufacture and maintain dentures because the muscles and nervous system in the oral cavity are not properly adjusted. In addition, excessively extended or thick dentures may cause muscle weakness by stimulating the muscles, so dentures should be manufactured in consideration of this. In this case, a denture was fabricated using the closed mouth technique in a patient with myasthenia gravis with mouth opening limitation. Using the closed mouth technique, the patient's masticatory pressure and muscle movements were reproduced and denture with good retention were manufactured.

Fabrication of CAD-CAM complete denture using existing provisional denture and digital facebow transfer (기존 임시의치와 디지털 안궁이전을 이용하여 상하악 CAD-CAM 총의치 수복 증례)

  • Jaehyeok Ro;Haemin Bang;Sangwon Park;Hyun-Pil Lim;Kwi-Dug Yun;Chan Park
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.4
    • /
    • pp.268-274
    • /
    • 2023
  • In this case, a CAD-CAM complete denture that can be easily remanufactured and reduced the number of visits was decided in consideration of the fact that it was difficult to visit the dental hospital and many existing dentures were lost because the patient was inpatient in a nursing hospital. In order to reflect the shape, vertical dimension, and maxillomandibular relationship of the existing provisional dentures adapted by the patient to the fabrication of the final denture, the existing provisional dentures were scanned and closed mouth impression was taken with the printed individual tray. After digital facebow transfer using UTS CAD and arranging artificial teeth in CAD software, the maxillary and mandibular complete dentures were fabricated by milling the denture base and artificial teeth at once with the monolithic disc.

Fabrication of mandibular suction denture for complete edentulous patient: A case report (하악 흡착식 의치를 이용한 완전 무치악 환자의 총의치 수복 증례)

  • Park, Minhyuk;Park, Sang-Won;Lim, Hyun-Pil;Park, Chan;Yun, Kwi-Dug
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.3
    • /
    • pp.257-267
    • /
    • 2020
  • The goal of suction denture is to enhance retention of dentures by the formation of negative pressure between the denture base and the underlying tissue and sealing around the denture by the mucosa. This patient has been converted to a completely edentulous state after the extraction of residual teeth. Fabrication of suction denture was planned because it was estimated that the conventional compete would be hard to achieve retention due to the absorption of residual ridge and lack of sublingual fold. Through appropriate clinical and laboratory technique such as preliminary impression on the mandibular rest position, provisional vertical dimension determination with Centric Tray® (Ivoclar Vivadent AG, Schaan, Liechtenstein), closed mouth definitive impression and jaw relation record using individual tray with Gnathometer M® (Ivoclar Vivadent AG, Schaan, Liechtenstein), artificial teeth arrangement considering stability of the denture, and proper polymerization technique that minimizes polymerization shrinkage, restoring the patient with suction denture resulted in satisfaction throughout the function and asesthetics.

Fabrication of complete denture using digital technology in patient with mandibular deviation: a case report (하악 편위 환자에서 디지털 방식을 이용한 총의치 제작 증례)

  • Lee, Eunsu;Park, Juyoung;Park, Chan;Yun, Kwi-Dug;Lim, Hyun-Pil;Park, Sangwon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.38 no.1
    • /
    • pp.34-41
    • /
    • 2022
  • Recently, digital technology and computer-aided design/computer-aided manufacturing (CAD/CAM) environment have changed the clinician treatment method in the fabrication of dentures. The denture manufacturing method with CAD/CAM technology simplifies the treatment and laboratory process to reduce the occurrence of errors and provides clinical efficiency and convenience. In this case, complete dentures were fabricated using stereolithography (SLA)-based 3D printing in patient with mandibular deviation. Recording base were produced in a digital model obtained with an intraoral scanner, and after recording a jaw relation in the occlusal rim, a definitive impression was obtained with polyvinyl siloxane impression material. In addition, facial scan data with occlusal rim was obtained so that it can be used as a reference in determination of the occlusal plane and in arrangement of artificial teeth during laboratory work. Artificial teeth were arranged through a CAD program, and a gingival festooning was performed. The definitive dentures were printed by SLA-based 3D printer using a Food and Drug Administration (FDA)-approved liquid photocurable resin. The denture showed adequate retention, support and stability, and results were satisfied functionally and aesthetically.

Maxillary complete denture and mandibular fixed prosthesis restoration using CBCT based facebow transfer: a case report (CBCT를 기반으로 안궁이전을 시행한 상악 총의치 및 하악 고정성 보철 수복 증례)

  • JinYoung Chon;Su-Jin Ahn;Suk Won Lee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.62 no.4
    • /
    • pp.262-273
    • /
    • 2024
  • With the increasing use of CAD-CAM (computer-aided design-computer-aided manufacturing) methods for prosthesis fabrication, utilization of virtual articulators in CAD software has also increased. Among the various methods of positioning the maxilla in a virtual articulator, there are techniques that utilize CBCT (cone-beam computed tomography) or facial scans without the use of a facebow. In this case, a full-mouth rehabilitation was planned for a patient who exhibited multiple crown fractures and occlusal plane disharmony through maxillary complete denture and mandibular fixed prosthetic restoration. Radiopaque markers were added to the duplicated maxillary temporary denture to take closed-mouth impression, which was then scanned and positioned on the CBCT. On CBCT, hinge axis connecting the medial poles of both mandibular condyles along with the Frankfort horizontal plane was designated and utilized to perform virtual articulator mounting. Maxillary complete denture and mandibular fixed prostheses were fabricated, resulting in satisfactory aesthetic and functional outcomes.