• Title/Summary/Keyword: 평행투영모형

Search Result 5, Processing Time 0.019 seconds

DEM Generation from IKONOS Imagery by Using Parallel Projection Model (평행투영모형에 의한 IKONOS 위성영상의 수치고도모형 생성)

  • Kim, Eui-Myoung;Kim, Seong-Sam;Yoo, Hwan-Hee
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.13 no.1 s.31
    • /
    • pp.55-61
    • /
    • 2005
  • Digital Elevation Model (DEM) generation from remotely sensed imagery is crucial for a variety of mapping applications such as ortho-photo generation, city modeling. High resolution imaging satellites such as SPOT-5, IKONOS, QUICK-BIRD, ORBVIEW constitute an excellent source for efficient and economic generation of DEM data. However, prerequisite knowledge in the areas of sensor modeling, epipolar resampling, and image matching is required to generate DEM from these high resolution satellite imagery. From the above requirements, epipolar resampling emerges as the most important factors. Research attempts in this area are still in high demand and short supply. Another cause that adds to the complication of the problem is that most studies of DEM generation from IKONOS scenes have been based on rational function model. In this paper, we proposed a new methodology for DEM generation from satellite scenes using parallel projection model which is sensor independent, makes it possible for sensor modeling and epipolar resampling by only few control points. The performance and feasibility of the developed methodology is evaluated through real dataset captured by IKONOS.

  • PDF

Noise Properties for Filtered Back Projection in CT Reconstruction (필터보정역투영 CT 영상재구성방법에서 잡음 특성)

  • Chon, Kwonsu
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.6
    • /
    • pp.357-364
    • /
    • 2014
  • The filtered back projection in the image reconstruction algorithms for the clinic computed tomography system has been widely used. Noise of the reconstructed image was examined under the input noise for parallel and fan beam geometries. The reconstruction images of $512{\times}512$ size were carried out under 360 and 720 projection by the Visual C++ for parallel beam and fan beam, respectively, and those agreed with the original Shepp-Logan head phantom very much. Noise was generated because of intrinsic restriction (finite number of projections) for the image reconstruction algorithm, filtered back projection, when no input noise was applied. Because the result noise was rapidly increased under 0.5% input noise ratio, technologies for reducing noise in CT system and image processing is important.

DEM Generation from IKONOS Satellite Imagery (IKONOS 위성영상의 수치고도모형 생성)

  • Kim, Eui-Myoung;Kim, Seong-Sam;Yoo, Hwan-Hee
    • 한국공간정보시스템학회:학술대회논문집
    • /
    • 2005.05a
    • /
    • pp.369-374
    • /
    • 2005
  • 정사영상 생성, 도시 공간의 모형화 등 도면화의 다양한 응용분야에 적용을 위해서는 위성 영상으로부터 수치고도모형을 생성하는 것은 중요하며, SPOT-5, IKONOS, QUICKBIRD, ORBVIEW 등의 고해상도 위성영상은 효율적이고 경제적으로 수치고도모형을 생성할 수 있는 정보를 제공하고 있다. 그러나, 이들 고해상도 위성영상으로부터 수치고도모형을 생성하기 위해서는 센서모형화, 에피폴라 영상 생성 그리고 영상정합에 대한 사전지식이 필요하다. 이들 중 에피폴라 영상생성은 중요한 인자이며 이에 대한 연구는 아직 미흡한 실정이다. 뿐만 아니라, IKONOS 위성영상으로부터 수치고도모형을 생성하는 연구는 다항식비례모형에 기반한 연구가 주로 이루어졌다. 이에 본 연구에서는 센서 독립적이면서 적은 수의 기준점만으로 센서모형화와 에피폴라 영상생성이 가능한 평행투영모형을 이용하여 수치고도모형을 생성하는 일련의 처리과정을 새롭게 제안하였다. 제안된 방법론은 IKONOS 위성영상을 이용하여 적용하고 평가하였다.

  • PDF

Comparison Among Sensor Modeling Methods in High-Resolution Satellite Imagery (고해상도 위성영상의 센서모형과 방법 비교)

  • Kim, Eui Myoung;Lee, Suk Kun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.6D
    • /
    • pp.1025-1032
    • /
    • 2006
  • Sensor modeling of high-resolution satellites is a prerequisite procedure for mapping and GIS applications. Sensor models, describing the geometric relationship between scene and object, are divided into two main categories, which are rigorous and approximate sensor models. A rigorous model is based on the actual geometry of the image formation process, involving internal and external characteristics of the implemented sensor. However, approximate models require neither a comprehensive understanding of imaging geometry nor the internal and external characteristics of the imaging sensor, which has gathered a great interest within photogrammetric communities. This paper described a comparison between rigorous and various approximate sensor models that have been used to determine three-dimensional positions, and proposed the appropriate sensor model in terms of the satellite imagery usage. Through the case study of using IKONOS satellite scenes, rigorous and approximate sensor models have been compared and evaluated for the positional accuracy in terms of acquirable number of ground controls. Bias compensated RFM(Rational Function Model) turned out to be the best among compared approximate sensor models, both modified parallel projection and parallel-perspective model were able to be modelled with a small number of controls. Also affine transformation, one of the approximate sensor models, can be used to determine the planimetric position of high-resolution satellites and perform image registration between scenes.

Air Cavity Effects on the Absorbed Dose for 4-, 6- and 10-MV X-ray Beams : Larynx Model (4-, 6-, 10-MV X-선원에서 공기동이 흡수선량에 미치는 효과 : 후두모형)

  • Kim Chang-Seon;Yang Dae-Sik;Kim Chul-Yong;Choi Myung-Sun
    • Radiation Oncology Journal
    • /
    • v.15 no.4
    • /
    • pp.393-402
    • /
    • 1997
  • Purpose : When an x-ray beam of small field size is irradiated to target area containing an air cavity, such as larynx, the underdosing effect is observed in the region near the interfaces of air and soft tissue. With a larynx model, air cavity embedded in tissue-equivalent material, this study is intonded for examining Parameters, such as beam quality, field size, and cavity size, to affect the dose distribution near the air cavity. Materials and Methods : Three x-rar beams, 4-, 6- and 10-MV, were employed to Perform a measurement using a 2cm $(width){\times}L$ (length in cm, one side of x-ray field used 2cm (height) air cavity in the simulated larynx. A thin window parallel-plate chamber connected to an electrometer was used for a dosimetry system. A ratio of the dose at various distances from the cavity-tissue interface to the dose at the same points in a homogeneous Phantom (ebservedlexpected ratio, O/E) normalized buildup curves, and ratio of distal surface dose to dose at the maximum buildup depth were examined for various field sizes. Measurement for cavity size effect was performed by varying the height (Z) of the air cavity with the width kept constant for several field sizes. Results : No underdosing effect for 4-MV beam for fields larger than $5cm\times5cm$ was found For both 6- and 10-MV beams, the underdosing portion of the larynx at the distal surface was seen to occur for small fields, $4cm\times4cm\;and\;5cm\times5cm$. The underdosed tissue was increased in its volume with beam energy even for similar surface doses. The relative distal surface dose to maximum dose was changed to 0.99 from 0.95, 0.92, and 0.91 for 4-, 6-, and 10-MV, respectively, with increasing field size, $4cm\times4cm\;to\;8cm\times8cm$, For 6- and 10-MV beams, the dose at the surface of the cavity is measured less than the predicted by about two and three percent. respectively. but decrease was found for 4-MV beam for $5cm\times5cm$ field. For the $4cm\timesL\timesZ$ (height in cm). varying depth from 0.0 to 4.8cm, cavity, O/E> 1.0 was observed regardless of the cavity size for any field larger than about $8cm\times8cm$. Conclusion : The magnitude of underdosing depends on beam energy, field size. and cavity size for the larynx model. Based on the result of the study. caution must be used when a small field of a high quality x-ray beam is irradiated to regions including air cavities. and especially the region where the tumor extends to the surface. Low quality beam. such as. 4-MV x-ray, and larger fields can be used preferably to reduce the risk of underdosing, local failure. In the case of high quality beams such as 6- and 10-MV x-rays, however. an additional boost field is recommended to add for the compensation of the underdosing region when a typically used treatment field. $8cm\times8cm$, is employed.

  • PDF