• 제목/요약/키워드: 평행류

검색결과 138건 처리시간 0.027초

알루미늄 평판관 증발기 헤더 내 공기-물 2상류 분지 실험 (Distribution of Air-Water Two-Phase Flow in a Header of Aluminum Flat Tube Evaporator)

  • 김내현;신태룡;심용섭
    • 설비공학논문집
    • /
    • 제18권1호
    • /
    • pp.55-65
    • /
    • 2006
  • The air and water flow distribution are experimentally studied for a round header - flat tube geometry simulating a parallel flow heat exchanger. The number of branch flat tube is thirty. The effects of tube outlet direction, tube protrusion depth as well as mass flux, and quality are investigated. The flow at the header inlet is identified as annular. For the downward flow configuration, the water flow distribution is significantly affected by the tube protrusion depth. For flush-mounted configuration, most of the water flows through frontal part of the header. As the protrusion depth increases, more water is forced to the rear part of the header. The effect of mass flux or quality is qualitatively the same as that of the protrusion depth. Increase of the mass flux or quality forces the water to rear part of the header. For the upward flow configuration, however, most of the water flows through rear part of the header. The protrusion depth, mass flux, or quality does not significantly alter the flow pattern. Possible explanations are provided based on the flow visualization results. Negligible difference on the water flow distribution was observed between the parallel and the reverse flow configuration.

부분방전 검출을 위한 저, 고주파용 센서 해석 및 설계 (The Design of a Sensor for Measuring Partial Discharge Signals in Rotating Machines)

  • 허창근;김용주;강동식;정현교
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 한국정보통신설비학회 2004년도 하계학술대회
    • /
    • pp.6-10
    • /
    • 2004
  • 회전기기의 운전 상태에서 on-line 부분 방전시험은 고정자 권선의 절연상태를 검사, 평가 할 수 있는 중요한 수단으로서 이러한 부분방전시험을 통하여 회전기기 시스템의 사고예방을 위한 진단을 할 수 있다. 기존의 비접촉식 센서인 SSC는 부분방전 측정을 위하여 권선의 웨지 아래에 설치하는 방식으로 개발되어 [1], 설치가 불편하고 Global VPI 방식으로 제작된 소형 회전기에는 설치할 수 없는 단점이 있다. 본 논문에서는 소형 회전기에 사용가능한 저, 고주파용 부분방전 센서를 제안하였다. 웨지 위에 설치 가능한 SSC 형태의 마이크로스트립 센서 및 전송선로 이론을 이용한 2선 평행 전송선로 센서는 값이 싸고 소형 회전기에 설치할 수 있을 정도의 크기를 지니며, 기본적으로 센서의 구조가 고주파 웨이브가이드로서 고주파용 센서로 적합하다. 또한 저주파 신호를 검출하기 위한 센서로 로고우스키 코일 형태의 U 타입 센서는 와전류를 검출하는 센서로서 슬롯 외부에 설치 되어야 한다. 이러한 U 타입 센서와 마이크로스트립 센서 또는 2선 평행 전송선로를 동시에 설치할 경우 저, 고주파를 효과적으로 검출할 수 있다.

  • PDF

유하액막식 암모니아 흡수기에서 증기 유동방향에 따른 열 및 물질전달 특성 (Heat and Mass Transfer Characteristics of a Falling Film Ammonia Absorber with Respect to the Vapor Flow Direction)

  • 권경민;정시영;김병주;정은수
    • 설비공학논문집
    • /
    • 제16권1호
    • /
    • pp.16-25
    • /
    • 2004
  • The flow and heat/mass transfer in the falling-film of a heat exchanger can be influenced by the motion of the surrounding refrigerant vapor. In this study, the effect of the vapor flow direction on the absorption heat transfer has been investigated for a falling-film helical coil which is frequently used as the absorber of ammonia/water absorption refrigerators. The experiments were carried out for different solution concentration. The heat and mass transfer performance was measured for both parallel and counter-current flow. The effect of vapor flow on the heat and mass transfer is found to be increased with decreasing solution concentration. In the experiments with low solution concentration, whose vapor specific volume is great, the counter-current flow of vapor resulted in uneven distribution of falling-film and reduced the heat transfer performance of the absorber. The direction of the vapor flow hardly affected the thermal performance as the solution concentration became stronger since the specific volume of the ammonia/water vapor was much smaller than that of the water vapor.

알루미늄 평행류 열교환기 헤더 내 냉매 분배에 관한 연구 (A Study on the Refrigerant Distribution in an Aluminum Parallel Flow Heat Exchanger Header)

  • 김도영;김내현;김수환;변호원;이을종
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1123-1128
    • /
    • 2009
  • The refrigerant R-134a flow distributions are experimentally studied for a round header/ten flat tube test section simulating a brazed aluminum heat exchanger. Three different inlet orientations (parallel, normal, vertical) were investigated. Tests were conducted with downward flow for the mass flux from 70 to $130\;kg/m^2s$ and quality from 0.2 to 0.6. In the test section, tubes were flush-mounted with no protrusion into the header. It is shown that normal and vertical inlet yielded approximately similar flow distribution. At high mass fluxes or high qualities, however, slightly better results were obtained for normal inlet configuration. The flow distribution was worst for the parallel inlet configuration. Possible explanation is provided based on flow visualization results.

  • PDF

유로형상 변화에 따른 고분자 전해질 연료전지(PEMFC)의 성능 및 전달특성에 대한 3차원 수치 해석적 연구 (Three Dimensional Computational Study on Performance and Transport Characteristics of PEMFC by Flow Channel Patterns)

  • 이필형;조선아;최성훈;황상순
    • 신재생에너지
    • /
    • 제2권4호
    • /
    • pp.78-85
    • /
    • 2006
  • Selection of flow channel in the separation plate of PEMFC is very important parameter to improve its performance and reduce parasite loss. Flow patterns in the channel have great influence on the transport of hydrogen and air and removal of water generated from electrochemical reaction in diffusion layer. In this study. fluid flow in flow channel with parallel and interdigitated patterns are simulated three dimensionally on full flow domain including anode and cathode channel together. The numerical results show that the fuel cell with interdigitated flow channel represents better performance than that with parallel flow channel due to its strong convective transport across the gas diffusion layer. But the pressure drop in parallel flow channel is much more than that in interdigitated flow channel. And effects of temperature and stoichiometric number on performance can be calculated and analyzed as well. Nomenclature.

  • PDF

고분자 전해질 연료전지 멀티 스택 시스템의 수소극 흐름방향에 따른 습도분포 및 성능변화 (Humidity Distribution and Performance Variation of a PEMFC Multi Stack System According to the Direction of Anodic Supply)

  • 이용택
    • 설비공학논문집
    • /
    • 제30권3호
    • /
    • pp.143-148
    • /
    • 2018
  • In this study the performance and humidity variation for 2 unit cells connected in series were experimentally measured. The relative flow direction of hydrogen and air was changed from parallel flow to counter flow. Internal humidity distribution was then measured by 5 embedded sensors on each channel. In all experimental conditions, the former unit cell showed a better performance and the gap is noted to be higher when counter flow is applied. The performance was noted to be higher at high humidification case in the parallel flow. However, in the counter flow, the difference of performance according to the humidification is negligible. Hydrogen and air are discharged from the PEMFC unsaturated with water vapor at parallel flow/low humidification condition, which explains lower performance of the PEMFC than other conditions. The humidities in hydrogen and air streams of counter flow were noted to increase rapidly even at low humidification condition and the consequential even hydration of membrane is the reason of higher performance.

PF 열교환기의 열전달과 압력강하 특성 실험 연구 (Experimental of Study on Heat Transfer and Pressure drop of PF Heat Exchangers)

  • 엄유식;서동남;박경만;이상재;김대훈;권영철
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.519-524
    • /
    • 2008
  • In the present study, the air-side heat transfer and pressure drop characteristics of the fin-tube and PF heat exchangers have been experimentally investigated under the cooling standard condition. Fin type of PF heat exchanger is a triangler and squarer form. The experimental data of the slit fin-tube and two kinds of PF heat exchangers are measured using the air-enthalpy calorimeter and the constant temperature water bath. As the inlet air velocity increases, the heat transfer rate and pressure drop of the heat exchanger increased. The heat transfer rate and pressure drop of PF-2 heat exchanger of the squarer fin is larger than that of PF-1 heat exchanger of the triangler fin. As the inlet air temperature increases, the heat transfer rate decreases and the pressure drop is nearly uniform.

  • PDF

히트펌프 건조기용 PF 증발기의 능력과 제습량 실험 연구 (Experimental Study on the Heat Transfer Capacity and Dehumidification Performance of a Parallel Flow Evaporator for a Heat Pump Dryer)

  • 권영철;김기영;이석현;권정태
    • 설비공학논문집
    • /
    • 제25권9호
    • /
    • pp.516-521
    • /
    • 2013
  • In the present study, the performances of a fin-tube evaporator and three PF evaporators for a heat pump dryer were experimentally investigated. Among the tested evaporators, the PF3 type evaporator showed the highest values of heat transfer capacity and dehumidification performance, while the fin-tube evaporator had the lowest values. PF3 showed better performance compared to PF1 and PF2, due to the large pin pitch, which leads to more draining for dehumidified water. Also, the $45^{\circ}$ inclined PF evaporator presented better performance than that of the $90^{\circ}$ inclined PF evaporator, owing to its easier draining characteristics. The effect of air velocity was revealed to be quite large. When the air velocity increased by 20%, the heat transfer capacity and dehumidification performance increased 43%/11%, 48%/13% and 54%/23% for PF1, PF2 and PF3, respectively.

저층배수를 이용한 담수호화 촉진에 관한 연구 (IMPROVEMENT OF FRESHENING PROCESS BY MEANS OF UNDERDRAINAGE CONDUIT)

  • 서영제;김진규
    • 물과 미래
    • /
    • 제25권1호
    • /
    • pp.111-119
    • /
    • 1992
  • 간척사업에 있어 용수원이 되는 깊은 담수화호에서는 체절후 온도 및 염분농도차에 의한 이층류가 발생하게 되며 이중 저층염분수는 밀도류 흐름의 구조특성상 배수\ulcorner문만으로 배제가 어려우므로 별도의 저층배수시설을 계획하여 담수호화를 촉진하고 있다. 성층화된 담수화호에서 상층부의 염도변화에 영향을 주는 요소로는 크게 나누어 세가지로 대별한다. 첫째는 상, 하층간의 밀도차에 의한 내부경계면의 난류현상, 둘째는 상층부의 흐름과 요동(바람,파)에 의한 혼합작용, 셋째는 하층부 호저토에서 발생되는 염분의 확산이다. 따라서 담수호화 모형을 위한 이층류흐름의 염분평행방정식을 구획하고 이 모형이 가지는 여러 가지 매개변수를 현장에서 실측된 염분농도변화에 부합하도록 유도하였다.

  • PDF

제주도 신양리층의 연안퇴적환경 (Neaushore sedimentary environments of the Sinyangri Fornation in Cheju Island, Korea)

  • 한상준;윤호일
    • 한국해양학회지
    • /
    • 제22권1호
    • /
    • pp.1-8
    • /
    • 1987
  • 신양리층은 제주도 성산반도 주변에 발달된 층으로 주로 화산쇄설물, 현무암 역, 패각편으로 이루어져 있으며, 퇴적구조, 주직 및 퇴적물의 성분을 중심으로 암상 을 분류한 결과위로 가면서 평행층리 사암상(I), 역암상(II), 사층리 사암상(III)으 로 구분되었다. (암상 I)은 조립질 박층과 세립질 박층이 규칙적으로 반복 교호하 는 쇄기모양 및 평행층리를 보여주며 이는 foreshore 퇴적환경의 특징적인 퇴적구조 이다. 본 암상의 입자들을 다른 두 암상에 비해 양호한 원마도와 분급도를 보이며 부분적으로 역분급층리를 보인다. (암상 II)는 clast-supported하고 매우 불량한 분 급도의 현무암 역으로 이루어져 있으며 신앙리해변을 따라 연속되어 노출되어 있 다. 역 사이의 공간을 주로 화산쇄설물과 원마도가 양호한 소량의 패각쇄설물로 채 워져 있다. 현무암 역의 크기 감소뿐만 아니라 최대 층후도 남쪽(신양리)으로 가면 서 줄어든다. 이 암상 하부에 는 직 하부의 (암상 I)로부터 기원한 커다란 판상의 역이층리면에 평행하게 누워 있으며 역의 크기는 다양하고 불규칙하며 어떤 지역적 인 방향성을 보이지 않는다. 이는 원지(in-situ) 침식잔류 역으로 판단된다. 따라서 현무암역은 해수면의 상대적인 상승으로 인한 해빈잔류역으로 이역들을 부분적으로 연안류와 파랑에너지의 영향을 받았을 것으로 판단된다. (암상 II)의 상부에 발달한 남쪽으로 경사하는 사층리는 연안류의 존재와 방향을 알려준다. (암상 III)은 세립내 지 중립사 크기의 주로 화산쇄설물로 이루어진 암상으로 상부 내해안(upper shoref ace)의 특징인 육지와 바다쪽으로 경사하는 bidirectional trough cross-stratification 과 파랑물결구조가 나타난다. 전반적으로 신양리층은 foreshore에서 상부내해안에 이르는 환경에서 퇴적되었으며 (암상 I)과 (암상 II)사이에는 소규모의 부정합이 존재한다.

  • PDF