• 제목/요약/키워드: 평행류

검색결과 138건 처리시간 0.027초

Study on Power Characteristics in the PEMFC Parallel Channel with Baffles through Numerical Analysis (전산해석을 통한 PEMFC 평행 유로에서 Baffle에 의한 출력특성 분석)

  • Kwon, Oh-Jung;Oh, Chang-Mook;Shin, Hee-Sun;Oh, Byeong Soo
    • Journal of the Korean Electrochemical Society
    • /
    • 제17권3호
    • /
    • pp.193-200
    • /
    • 2014
  • Research on flow channel designs of the separate plates is necessary to improve the PEMFC performance. On concerning the performance improvement of PEMFC, many recent studies have been made on the interdigitated flow channel using forced convection. In this paper, the interdigitated flow channel is similarly applied on the parallel flow channel with a baffle or baffles. Numerical analysis is performed by using a commercial multiphysics program, which is called COMSOL, on the parallel channel with the fully blocked baffle(FBB) and there are three variables, the position of baffle, flow direction and flow velocity. Each power of the variables is resulted from the fixed 0.5V, the voltage from 80 percents of the maximum power. Finally, based on the full factorial designs(FFD), one of the design of experiments(DOE), each factor which has several levels lead to the conclusion. The analysis of the main effects and interactions of the factors is useful to find the most influenced factor to improve the power.

Performance of Heat Recovery System using Evaporative Cooling (증발냉각을 이용한 배기열 회수장치의 성능에 관한 연구)

  • Yoo, Seong Yeon;Kim, Tae Ho;Kim, Myung Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • 제39권1호
    • /
    • pp.37-43
    • /
    • 2015
  • Evaporative cooling is a very effective way for exhaust heat recovery that uses both latent heat and sensible heat. This study investigated the performance of a heat recovery system using evaporative cooling. The experimental apparatus comprised a plastic heat exchanger, a water spray nozzle, an air blowing fan, a water circulation pump, and measuring sensors for the temperature, humidity, and flow rate. The effectiveness of the sensible heat recovery without evaporation was measured and compared with that of the total heat recovery with evaporation. The effectiveness of the sensible and total heat recoveries decreased as the air flow rate increased, and a much higher effectiveness was obtained with the counterflow arrangement in both cases. For total heat recovery, the effectiveness increased with the water flow rate, and the parallel flow arrangement was found to be more sensitive to the water flow rate than the counterflow arrangement.

The Effect of refrigerant pass & distribution in aluminum parallel flow heat exchanger (알루미늄 평행류 열교환기에서 냉매패스와 분배량 변화의 영향)

  • Kim, Jeong-Sik;Kim, Nae-Hyun;Kim, Kwang-Hee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • 제10권12호
    • /
    • pp.3546-3552
    • /
    • 2009
  • In this study, an analysis code was created for a 190*650*25-mm (W*H*D) parallel-flow evaporator, and research was done on how to increase the heat transfer rate of aluminum PF heat exchanger for application in IDU. After varying the R410A refrigerant up-down flow to two and three passes and the distribution ratio to 1:1:1 and 1:2:2, it was determined that the two-pass flow has a 30% higher partial heat transfer rate and a 25% lower heat transfer coefficient compared to the three-pass flow. As for the distribution ratios of the three-pass flow, 1:1:1 was found to have a lower refrigerant pressure loss than 1:2:2 distribution. It was assumed, though, that the refrigerant distribution had a uniform flow and that its value was thus overestimated in the actual case of maldistribution in each pass.

Numerical Study of Heat and Mass Transfer Characteristics in Microchannel Steam Methane Reforming Reactor (마이크로채널 메탄 수증기 개질 반응기의 열 및 물질 전달 특성에 관한 수치해석 연구)

  • Jeon, Seung-Won;Lee, Kyu-Jung;Cho, Yeon-Hwa;Moon, Dong-Ju
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • 제36권9호
    • /
    • pp.885-894
    • /
    • 2012
  • A numerical study of a microchannel steam methane reforming reactor has been performed to understand the characteristics of heat and mass transfer. The integration of Rh-catalyzed steam methane reforming and Pt-catalyzed methane combustion has been simulated. The reaction rates for chemical reactions have been incorporated into the simulation. This study investigated the effect of contact time, flow pattern (parallel or counter), and channel size on the reforming performance and temperature distribution. The parallel and counter flow have opposite temperature distribution, and they show a different type of reaction rate and species mole fraction. As the contact time decreases and channel size increases, mass transfer between the catalyst layer and the flow is limited, and the reforming performance is decreased.

Experimental Study on Cooling Performance of A/C applied Fin-tube and PF Heat Exchangers (핀-관, 평행류 열교환기를 적용한 공조기의 냉방성능 실험연구)

  • Kwon, Young-Chul;Park, Yoon-Chang;Kwon, Jeong-Tae;Park, Gyung-Man
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • 제10권8호
    • /
    • pp.1789-1794
    • /
    • 2009
  • In the present study, the cooling performance characteristics on environment changes of A/C applied fin-tube and PF heat exchangers were experimentally investigated. Capacity and COP on an air velocity, an indoor/outdoor temperature and an indoor/outdoor relative humidity were obtained. Fin types of PF heat exchanger were a triangler and squarer form. The experimental data for the three kinds of heat exchangers were measured using the air-enthalpy calorimeter. Performance of PF A/C was more excellent than that of a fin-tube A/C. Also, the performance of PF-2 A/C with the squarer fin was more excellent than that of PF-1 A/C with the triangler fin. As the air velocity, the indoor temperature and the indoor relative humidity increase, capacity and COP increase. And as outdoor temperature increases, capacity and COP decrease. But, the performance change on the outdoor relative humidity was insignificant.

Numerical Study on the Mixing Enhancement of Parallel Supersonic-subsonic Wakes Using Wall Cavities (공동을 이용한 초음속-아음속 평행류에서의 혼합증대에 관한 수치적 연구)

  • Moon, Seong-Mok;Chang, Se-Myong;Kim, Chong-Am;Lee, Kyoung-Hoon;Kim, In-Soo;Ahn, Su-Hong;Woo, Kwan-Je
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 한국추진공학회 2010년도 제34회 춘계학술대회논문집
    • /
    • pp.353-356
    • /
    • 2010
  • A computational study on the enhancement of parallel supersonic-subsonic mixing wakes is conducted and compared with available experimental data. The first aim of the present work is to show a direct comparison between numerical predictions and equivalent experimental data for the baseline case. The Pitot pressure distribution data are in good agreement between computation and experiment, and the results show that Menter's SST model with the compressibility correction gives the best performance. Further we investigate the effects of primary parameters such as the position of the cavity, and the arrangement of the cavity at the given flow condition.

  • PDF

Numerical Simulation of Mixing Control in Parallel Supersonic- Subsonic Jet Using Acoustic Waves (음향파를 이용한 두 평행류의 혼합 증대)

  • Shin, Seong-Ryong;Chang, Se-Myong;Lee, Soogab
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 한국소음진동공학회 2001년도 춘계학술대회논문집
    • /
    • pp.751-756
    • /
    • 2001
  • An experimental model of the advanced mixing control in the parallel supersonic-subsonic mixing jet (M$_1$=1.78 and M$_2$=0.30) is numerically simulated. An oscillating wall boundary condition is used as the modeling of a wall cavity for mixing enhancement. The obtained pitot pressure distributions along cross sections at the developing region of the turbulent jets are validated from the good agreement with equivalent experimental data. The similarity solution of dimensional analysis also coincides with this numerical result at the self-similar region sufficiently far from the jet exit.

  • PDF

Performance Characteristics on Environment Change of A/C applied Fin-tube and PF Heat Exchangers (환경변화에 따른 핀-관, PF 열교환기 적용 공조기 성능 특성 실험 연구)

  • Park, K.M.;Um, U.S.;Kwon, Y.C.;Lee, S.J.
    • Proceedings of the SAREK Conference
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1267-1271
    • /
    • 2009
  • In the present study, performance characteristics on environment change of A/C applied fin-tube and PF heat exchangers were experimentally investigated. Capacity and COP changing an outlet air velocity, an indoor/outdoor temperature and a relative humidity were obtained. Air-enthalpy calorimeter was used. As the air velocity, indoor temperature and relative humidity increase, capacity and COP increase. PF A/C has smaller refrigerant weight than the fin-tube A/C. The performance of PF-2 A/C with the squarer fin was more excellent than that of PF-1 A/C with the triangler fin.

  • PDF

Experimental Study on the Freezing Conditions in a Ice-making Tube Using Flowing Subcooled Water (유동과 냉각수 이용 제빙관의 동결조건에 5관한 실험적 연구)

  • 박영하;현명택;이동원
    • Journal of Energy Engineering
    • /
    • 제9권3호
    • /
    • pp.178-183
    • /
    • 2000
  • 본 연구에서는 유동과 냉각수를 이용하는 아이슬러리 제조관정을 관찰하고, 이 시스템의 가장 큰 문제점인 관내동결 특성을 파악하였다. 시험수로는 수도수(city water)를 이용하였다. 시스템을 순환하는 시험수가 제빙관내에서 $0^{\circ}C$ 이하의 과냉각 조건이 형성되어 제빙관을 빠져 나오면서 축냉조에 설치된 충격판상에서 과냉각 해소가 일어났다. 이때 유동과냉각수는 내부에너지를 방출하면서 그 일부가 얼음 입자로 상변화되었고, 나머지는 실험장치를 계속순환하였다. 제빙관에서 시험수와 브라인의 열교환 방식을 대향류와 평행류 두 조건에서 시험수의 과냉각도는 Reynolds 수가 증가함에 따라 감소하는 경향을 보였고, 이들 결과 값으로부터 각각의 관계식을 유도하였다. 또한 브라인의 냉각속도가 0.29~0.53[$^{\circ}C$/min] 범위에서 시험수의 과냉각도는 브라인 냉각속도에 종속되지 않았다.

  • PDF