• Title/Summary/Keyword: 평균 양방향 유동 튜브

Search Result 5, Processing Time 0.02 seconds

Development of an Average Bi-directional Flow Tube for the Measurement of Single and Two phase Flow Rate (단상 및 이상유동 유량 계측을 위한 평균 양방향 유동 튜브 개발)

  • Yun, Byong-Jo;Kang, Kyong-Ho;Euh, Dong-Jin;Baek, Won-Pil
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.172-179
    • /
    • 2004
  • Average Bi-directional flow tube was suggested to measure single and two phase flow rate. Its working principle is similar with Pilot tube, however, it makes it possible to eliminate the cooling system which is normally needed to prevent from flashing in the pressure impulse line of Pilot tube when it is used in the depressurization condition. The suggested instrumentation was tested in the air-water vertical test section which has 80mm inner diameter and 10m length. The flow tube was installed at 120 of L/D from inlet of test section. From the test, single air and water flow rate was measured successfully. For the emasurement of two phase flow rate, Chexal drift-flux correlation was used. In the test a new correlation of momentum exchange factor was suggested. The test result shows that the suggested instrumentation using the measured void fraction and Chexal drift-flux correlation can predict the mass flow rates within $10\%$ error of measured data.

  • PDF

FLUENT Code Analyses for Design Optimization of an Average Bi-directional Flow Tube (평균 양방향 튜브의 설계 최적화를 위한 FLUENT 코드해석)

  • Kang, Kyong-Ho;Yun, Byong-Jo;Euh, Dong-Jin;Baek, Won-Pil
    • The KSFM Journal of Fluid Machinery
    • /
    • v.8 no.4 s.31
    • /
    • pp.14-19
    • /
    • 2005
  • Average Bi-directional flow tube was suggested to measure single and two phase flow rate. Its working principle is similar with Pilot tube, however, it makes it possible to eliminate the cooling system which is normally needed to prevent from flashing in the pressure impulse line of Pilot tube when it is used in the depressurization condition. 3-dimensional steady state flow analyses using FLUENT 5.4 code were performed to validate the application of the average bi-directional flow tube in case of water and air flow. In this study, sensitivity studies have been performed to optimize the design features of the average bi-directional flow tube which can be applied for the various experimental conditions. For Re numbers above 1000, the k values are nearly constant regardless of the Re numbers and flow types and calculation results and experimental data coincides quite well. The current FLUENT calculation results suggest that linearity of the k values in various design features of the average BDFT is highly promising, which means that it is quite reasonable to select the typical design of the average BDFT for the convenience of the experimental conditions.

FLUENT Code Analyses for Design Optimization of an Average Bi-directional Flow Tube (평균 양방향 튜브의 설계 최적화를 위한 FLUENT코드해석)

  • Kang, Kyong-Ho;Yun, Byong-Jin;Euh, Dong-Jin;Baek, Won-Pil
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.180-186
    • /
    • 2004
  • Average Bi-directional flow tube was suggested to measure single and two phase flow rate. Its working principle is similar with Pilot tube, however, it makes it possible to eliminate the cooling system which is normally needed to prevent from flashing in the pressure impulse line of Pilot tube when it is used in the depressurization condition. 3-dimensional steady state flow analyses using FLUENT 5.4 code were performed to validate the application of the averagebi-directional flow tube in case of water and air flow In this study, sensitivity studies have been performed to optimize the design features of the average hi-directional flow tube which can be applied for the various experimental conditions. For Re numbers above 1000, the k values are nearly constant regardless of the Re numbers and flow types and calculation results and experimental data coincides quite well. The current FLUENT calculation results suggest that linearity of the k values in various design features of the average BDFT is highly promising, which means that it is quite reasonable to select the typical design of the average BDFT for the convenience of the experimental conditions.

  • PDF

Numerical Study of the Averaging BDFT(bidirectional flow tube) Flow Meter on the Applicability in the Fouling Condition (수치해석을 이용한 평균 양방향 유동 튜브 유량계의 파울링 환경 적용성 연구)

  • Park, JongPil;Jeong, JiHwan;Kang, KyongHo;Baek, WonPil;Yun, ByongJo
    • The KSFM Journal of Fluid Machinery
    • /
    • v.16 no.4
    • /
    • pp.35-43
    • /
    • 2013
  • Most of the nuclear power plants(NPPs) adopts pressure difference type flow meters such as venturi and orifice meters for the measurement of feedwater flow rates to calculate reactor thermal power. However, corrosion products in the feedwater deposits on the flow meter by fouling as operating time goes. These effects lead to severe errors in the flow indication and then determination of reactor thermal power. The averaging BDFT, which has developed by Yun et al., has a potentiality to minimize this problem thanks to its inherent measurement principle. Therefore, it is expected that the averaging BDFT can replace the venturi meter for the feedwater pipe of steam generator of NPPs. The present work compares the amplification factor, K, based on CFD calculation against the K obtained from experiments in order to confirm whether a commercial CFD code can be applicable to the evaluation of characteristic for the averaging BDFT. In addition to this, the simulations to take into account of fouling effect are also carried out by rough wall option. The results show that the averaging BDFT is a promising flow meter for the accurate measurement of flow rates in the fouling condition of the NPPs.