• Title/Summary/Keyword: 평균파워

Search Result 171, Processing Time 0.026 seconds

Effects of Walking Exercise on Isokinetic Muscular Function (걷기운동이 등속성 근력에 미치는 효과)

  • Lee, Jong-Bok;Kim, Jong-Hyuck
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.10
    • /
    • pp.427-435
    • /
    • 2009
  • The aim of this study was to examine the effect of a brisk walking intervention for 8weeks on isokinetic muscular function factor(strength, power, endurance). The following results were found from the current study: First, Isokinetic muscle function(strength, power, endurance) on $60^{\circ}/sec$ in extension and flexion was significant exercise group and interaction in left knee flexion and right knee extension(P<.00l). Secondly, Isokinetic muscle function(strength, power, endurance) on $120^{\circ}/sec$ in extension and flexion was significant exercise group and interaction in left knee flexion and right knee extension(P<.001). Thirdly, Isokinetic muscle function(strength, power, endurance) on $180^{\circ}/sec$ in extension and flexion was significant exercise group and interaction in left knee flexion and right knee extension(P<.001). Considering the above result of the study the brisk walking had more improvement knee flexor and extensor muscular power. Therefore the brisk walking in the study can be proposed as effective plan to prevention hurt from a sarcopenia and to raise quality in life.

A New Feature for Speech Segments Extraction with Hidden Markov Models (숨은마코프모형을 이용하는 음성구간 추출을 위한 특징벡터)

  • Hong, Jeong-Woo;Oh, Chang-Hyuck
    • Communications for Statistical Applications and Methods
    • /
    • v.15 no.2
    • /
    • pp.293-302
    • /
    • 2008
  • In this paper we propose a new feature, average power, for speech segments extraction with hidden Markov models, which is based on mel frequencies of speech signals. The average power is compared with the mel frequency cepstral coefficients, MFCC, and the power coefficient. To compare performances of three types of features, speech data are collected for words with explosives which are generally known hard to be detected. Experiments show that the average power is more accurate and efficient than MFCC and the power coefficient for speech segments extraction in environments with various levels of noise.

Effects of Short Term Creatine Loading on Repeated Bouts of Kicking, Plasma Components and Anaerobic power in Taekwondo player (단기간의 크레아틴 섭취가 태권도 선수의 발차기 횟수, 혈장요소 및 무산소성 파워에 미치는 영향)

  • Lee Ho-Song
    • The Journal of the Korea Contents Association
    • /
    • v.6 no.4
    • /
    • pp.136-145
    • /
    • 2006
  • The main purpose of the present study was to find the effect of short term creatine loading on repeated bouts of kicking, plasma creatine phosphokinase and anaerobic power in male taekwondo player from high school. Eighteen male were randomly assigned to two groups. They were tested before and after 6 days of placebo($4{\times}5$ glucose d-1, N=9) or Creatine monohydrate loading(consume 0.3g kg-1, N=9). Only creatine loading group were significantly increased of repeated bouts of kicking, plasma creatine phosphokinase and anaerobic power These results suggest that short creatine loading was effective diet protocol in taekwondo player from male high school.

  • PDF

Development of Global Simulator of $O_2$ Discharge in High Density Transformer Coupled Plasma Source (고밀도 유도결합 플라즈마 장치의 $O_2$ 방전에 대한 공간 평균 시뮬레이터 제작)

  • Kim, Hyung-Yong;Yoon, Nam-Sik;Kwon, Deuk-Chul;Kim, Jeong-Hyung;Jeong, Kwang-Hwa;Sin, Yong-Hyun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.550-551
    • /
    • 2005
  • 고밀도 유도결합 플라즈마 장치의 $O_2$ 방전에 대한 공간 평균 시뮬레이터를 제작하였다. 제작된 시뮬레이터는 $O_2$ 플라즈마 방전에서 발생되는 전자, 양이온, 음이온 및 중성종, 활성종들에 대해 공간 평균된 유체 방정식을 기반으로 하고 있으며, 고밀도 유도결합 플라즈마 장치에서 전자가열 모델은 anomalous skin effect 를 고려한 파워 흡수 모델을 적용하여 전자가 흡수하는 고주파 파워량을 결정하였다. 완성된 시뮬레이터에서 RF- 파워, gas-inlet, pumping-speed등의 조정 변수를 비롯한 여러 가지 장치 변수들의 변화에 대한 하전입자, 중성종, 활성종들의 밀도 변화 및 전자 온도 의존성을 계산하였다.

  • PDF

Research on Frequency Average Analysis of vibrational Power Flow Analysis (진동파워흐름해석의 주파수 평균해석에 대한 연구)

  • Lee, Jea-Min;Hong, Suk-Yoon;Park, Young-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.971-977
    • /
    • 2005
  • Power Flow Analysis (PFA) is developed for the effective predictions of frequency-averaged vibrational response in medium-to-high frequency ranges. In PFA, the power coefficients of semi-infinite structure and for-field energy density are used to predict the vibrational responses of structures. Generally, at high frequencies, PFA can predict narrow-band frequency-averaged vibrational responses of built-up structures. However, in low- to medium frequency ranges, the dynamic responses obtained by PFA represent broad-band frequency-averaged vibrational energy densities. For the prediction of vibrational response variance in Power Flow Finite Element Method (PFFEM), the variances of input power and joint element matrix describing structural coupling relationship are derived. Finally, for the validity of developed formulation, numerical examples for two co-planer plates are performed and the vibrational response variance of the structure are compared with the results of classical and PFFEM solutions.

  • PDF

Effect of Happiness and Empowerment on Nursing Performance of Clinical Nurses (간호사의 행복감과 임파워먼트가 간호업무성과에 미치는 영향)

  • Kim, Seon-Young;Kwon, Young-Eun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.1
    • /
    • pp.112-120
    • /
    • 2020
  • This study examined the relationship between the happiness, empowerment, and nursing performance of nurses with more than one-year of clinical experience, and the factors affecting the nursing performance. The subjects were 164 nurses who worked in two general hospitals in Incheon and Chungcheong-do, Korea. Data were collected from October to November 2018. The main findings of this study were as follows. The mean scores for happiness, empowerment, and nursing performance were 3.07±0.36, 3.37±0.43, and 3.40±0.44 points. Happiness was positively correlated with empowerment (r=.58, p<.01) and nursing performance (r=.58, p<.01), empowerment was positively correlated with the nursing performance (r=.58, p<.01). The factors influencing the nursing performance were empowerment (β=.65, p<.001), total length of a clinical career (β=.19, p<.001), education level (β=.12, p<.05), and happiness (β=.12, p=.05), showing an explanatory power of 64%. Based on these results, it is necessary to provide sufficient human and physical resources to improve the nursing performance and manage the organizational level to increase the nurses' happiness and empowerment. To improve the work performance of nurses, an empowerment improvement program tailored to the clinical experience and educational level should be developed, and the working environment that can increase the nurse's happiness should be improved.

A Comparison of Physical Fitness of High School Ssirum Elite-players According to Their Weight Class (고등부 씨름선수의 체급별 기초·전문체력 비교분석)

  • Jung, Joo-Ha;Kim, Sung-Eun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.12
    • /
    • pp.162-169
    • /
    • 2020
  • This study was conducted from November 25 to December 4, 2019, to unmask differences in physical fitness based on the weight class of high school Ssirum elite-players. A total of 28 high school Ssirum elite-players were compared and analyzed by measuring physical factors (muscle strength/power, agility, anaerobic power, aerobic ability, flexibility, and isokinetic muscle function) by weight class. Data were analyzed using SPSS ver. 23.0. One-way ANOVA was used for comparison between groups. There was no difference by weight class in terms of grip strength, sit-ups, sergeant jump, long jump, flexibility, side step, and reaction time. Evaluation of back muscle strength revealed that the group with more than 100 kg had greater strength than lower weight categories, whereas it was lower in the sit-ups, 20 m shuttle run and the relative values anaerobic power. Considering isokinetic muscle function, no difference was observed between the groups of back muscle strength and knee joint. The results of this study indicate that amongst the high school Ssirum elite-players, there is no difference in muscle power, flexibility, agility, and anaerobic average power per body weight, isokinetic trunk strength, and knee flexion strength, when evaluated according to weight class.

Isokinetic Strength Capacity Between Elite Athletes and Taekwondo Player (엘리트 육상선수와 태권도 선수의 등속성 운동능력에 관한 비교 연구)

  • Kim, Hyun-Mi;Lee, So-Yun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.6
    • /
    • pp.2691-2697
    • /
    • 2011
  • The purpose of the dissertation is to offer basic data available for being conducive to application of a training program by comparatively analyzing the players' physical strength, the knee joint, a hip joint, power of the trunk joint and muscle power in order to study isokinetic strength and muscle power between short distance athletes and Taekwondo players. This study measured peak power, %Body weight peak power, always power, and %Body weight peak power targeting 8 male athletes and 8 male Taekwondo players who warmed up 10 minutes before from the test to reduce repulsion and unfamiliarity at the instrument. The power of the knee joint($60^{\circ}$/sec), muscle power($180^{\circ}$/sec), were measured by using HUNOM(U.S.A). As a result of the physical strength, statistically, short distance athletes were indicated to be better in muscle strength, muscular endurance than Taekwondo players, and there was no significant difference between flexibility, power, and muscular endurance. Although the short distance athletes were indicated to be better in right and left muscle strength of knee joint than Taekwondo player, there was no significant difference and Taekwonde players were indicated to be higher at the right and left muscle power than short distance athletes.

Development of High Density Inductively Coupled Plasma Sources for SiH4/O2/Ar Discharge (고밀도 유도 결합 플라즈마 장치의 SiH4/O2/Ar 방전에 대한 공간 평균 시뮬레이터 개발)

  • Bae, S.H.;Kwon, D.C.;Yoon, N.S.
    • Journal of the Korean Vacuum Society
    • /
    • v.17 no.5
    • /
    • pp.426-434
    • /
    • 2008
  • A space averaged $SiH_4/O_2/Ar$ simulator for the high density inductively coupled plasma sources for $SiH_4/O_2/Ar$ discharge is developed. The developed simulator uses space averaged fluid equations for electrons, positive ions, negative ions, neutral species, and radicals in $SiH_4/O_2/Ar$ plasma discharge, and the electron heating model including the anomalous skin effect. Using the developed simulator, the dependency of the density of charged particles, neutral particles, and radicals, the electron temperature, the plasma resistance, and the power absorption coefficient for the RF power and pressure is calculated.

A MAC Protocol for Transmission Power Control in Ad Hoc Networks (애드 혹 네트워크에서 전송파워 제어를 위한 MAC 프로토콜)

  • Hwang, Sungho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.2
    • /
    • pp.878-884
    • /
    • 2013
  • This paper presents a transmission power control MAC protocol that allows terminals to vary transmit power level on data frame basis in ad hoc network. Unlike the IEEE 802.11 approach, we do not use the RTS/CTS packets to silence the neighboring nodes. Instead, channel gain and distance information between transmitter and receiver terminal are inserted in the RTS/CTS packets. These informations are used to dynamically bound the transmission power. Simulation results indicate that, compared to the GMAC, the proposed MAC protocol achieves a increase in the average frame delivery ratio and a decrease in the average frame delay.