• Title/Summary/Keyword: 평균선량

Search Result 734, Processing Time 0.026 seconds

Influence of Total Laryngectomy on Spinal Cord Dose in Advanced Laryngeal Cancers (진행된 후두암 환자에서 후두전절제술에 의한 척수선량 변화)

  • Kim, Jae-Cheol;Kim, Sung-Hwan;Park, In-Kyu
    • Radiation Oncology Journal
    • /
    • v.14 no.2
    • /
    • pp.167-173
    • /
    • 1996
  • Purpose : This analysis was to evaluate the radiation dose around a tracheostoma and spinal cord in the case of advanced laryngeal cancers in which a total laryngectomy was done before radiotherapy. Materials and Methods : The radiation dose around a tracheostoma and spinal cord was measured by thermoluminescence and film dosimetry in the phantom, Radiotherapy treatment planning was done in 12 cases of advanced laryngeal cancer and compared with the measured dose in the phantom. Results : Mean spinal cord doses in the phantom by thermoluminescence dosimetry were $86.4\%$ (with a tracheostoma), $80.1\%$ (without a tracheostoma), and the difference was $6.3\%$. Mean spinal cord doses in the phantom by film dosimetry were $84.7\%$ (with a tracheostoma), $79.0\%$ (without a tracheostoma). and the difference were $5.7\%$. Calculated spinal cord doses in the phantom were $84.0\%$ (with a tracheostoma), $78.0\%$ (without a tracheostoma), and the difference was $6.0\%$. Mean calculated spinal cord doses in 12 patients were $83.1\%$ (with a tracheostoma), $76.9\%$ (without a tracheostoma). and the difference was $6.2\%$. Measured dose of lateral and posterior wall of the tracheostoma by film was low (depth of maximum dose = 12 mm). Conclusion : In the treatment planning of the advanced laryngeal cancers, the radiation dose of the tracheostoma and spinal cord should be evaluated and be followed by an appropriate management such as a bouls or a brachytherapy boost if the dose around the tracheostoma is low.

  • PDF

Radiation Treatment Planning Evaluation by Internal Target Volume Settings (내부표적체적 설정을 통한 방사선치료계획 평가)

  • Park, Ho-Chun;Han, Jae-Bok;Choi, Nam-Gil
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.8
    • /
    • pp.416-423
    • /
    • 2015
  • The study was conducted targeting 25 patients who underwent the respiratory gated radiation therapy in the abdominal region at Radiation Oncology of a University Hospital from December 2013 to June 2014 and types of cancer included liver(64%), CBD(8%), gastric(8%), GB(8%), pancreas(8%), SMA(4%). The means of ITV and PTV volume are 471.44 cm3 and 425.48 cm3, showing an increase in volume. Normal tissue volume was also found to have increased due to the increase of the section selected from PTV section to ITV section. Right kidney showed a significant increase in differences between increase in normal tissue volume, increase in target volume and increase in therapy irradiation area and difference between the means of dose applied to normal tissue. There was no significant difference in the mean dose applied to normal tissue according to the respiratory average. Both kidneys showed a significant difference in the difference between mean doses of target moving and normal tissue. In this study, both therapy methods through PTV section and ITV section volume setting were appropriate for protection doses of normal tissue and distributed over 95% of the prescribed dose and therefore, it is considered to be okay to be optionally used depending on the patient's therapeutic purpose. But in order to minimize the unexpected side effect, the plan of PTV section and ITV section should be established and used by evaluating normal tissue protection dose.

Analysis of the Distributional Effects of Radioactive Materials on External Gamma Exposure (방사성물질의 분포특성에 따른 외부 감마피폭해석)

  • Han, Moon-Hee;Kim, Eun-Han;Suh, Kyung-Suk;Hwang, Won-Tae;Choi, Young-Gil
    • Journal of Radiation Protection and Research
    • /
    • v.23 no.4
    • /
    • pp.211-218
    • /
    • 1998
  • The distributional effects of radioactive materials on external gamma exposure have been analyzed. An approximate method for estimating external gamma dose given from an arbitrary distribution of radioactive material has been developed. The minimum gamma exposure given from a point source is shown at 0.07 MeV if the source to receptor distance is shorter than 10 m. But if the receptor to point source distance is longer than 20 m, gamma exposure rate increases monotonously according to the average gamma energy. For the analysis of the effects of volume source, we estimated the gamma dose given from different size of hemisphere in which radioactive materials are distributed uniformly. When the radius of hemisphere is longer than 40 m, external gamma dose rate increases monotonously. The gamma dose rate given from the radioactive materials deposited on the ground shows the minimum value at 0.07 MeV in any case. The analysis shows that external gamma exposure is strongly dependent on the distribution of radioactive materials in the environment and gamma energy.

  • PDF

Comparison of Operator Radiation Exposure Dose undergoing Cardiac Angiography and Cardiac Intervention (심장혈관 중재적 시술의 시술자 피폭 선량에 관한 연구)

  • Kim, Jungsu;Kwon, Soonmu;Jung, Haekyoung;Lee, Bongki;Ryu, Dongryeol;Kwon, Hoseok;Cho, Byungryul
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.3
    • /
    • pp.181-186
    • /
    • 2016
  • Cardiac angiography(CA) or cardiac intervention(CI) is one of the major examination methods applied to the detection of cardiovascular diseases using X-rays. These CA and CI procedures require radiation exposure to patients and physicians. We evaluated the radiation dose to cardiac operator during the each case of CA and CI procedures. The number of patients is 113 patients in CA and 34 patients in CI. Mean fluoroscopy time, mean cine time, and mean total cumulative dose area product(DAP) in patients during CA and CI was 165.9 sec vs. 1200.0 sec, 30.31 sec vs 107.5 sec, and $37130.3mGy.cm^2$ vs $213312.6mGy.cm^2$, respectively. Mean dose of thyroid, over chest apron and under chest apron in operator during CA and CI was 15.84 uSv vs 89.81 uSv, 20.16 uSv vs 123.20 uSv, and 0.30 uSv vs 2.40 uSv, respectively. Mean effective dose of operator during CI was about 6 times greater than during CA. Also there was significant inter-relationship between fluoroscopy or cine time and effective dose in operator during CA and CI(p=0.001 and p=0.001, respectively).

Bolus Effect to Reduce Skin Dose of the Contralateral Breast During Breast Cancer Radiation Therapy (유방암 방사선치료 시 반대편 유방의 피부선량 감소를 위한 볼루스 효과)

  • Won, Young Jin;Kim, Jong Won;Kim, Jung Hoon
    • Journal of radiological science and technology
    • /
    • v.40 no.2
    • /
    • pp.289-295
    • /
    • 2017
  • The aim of this study was to evaluate the dose comparison using Radon phantom with 5 mm and 10 mm tissue equivalent materials, FIF, Wedge(15, 30 angle) and IMRT, to reduce the skin dose of the contralateral breast during breast cancer radiation therapy(Total dose: 50.4Gy). The dose was measured for each treatment plan by attaching to the 8 point of the contralateral breast of the treated region using a optical-stimulated luminance dosimeter(OSLD) as a comparative dose evaluation method. Of the OSLD used in the study, 10 were used with reproducibility within 3%. As a result, the average reduction rates of 5 mm and 10 mm in the FIF treatment plan were 37.23 cGy and 41.77 cGy, respectively, and the average reduction rates in the treatment plan using Wedge $15^{\circ}$ were 70.69 cGy and 87.57 cGy, respectively. The IMRT showed a reduction of 67.37 cGy and 83.17 cGy, respectively. The results of using bolus showed that as the thickness of the bolus increased in all treatments, the dose reduction increased. We concluded that mastectomy as well as general radiotherapy for breast cancer would be very effective for patients who are more likely to be exposed to scattered radiation due to a more demanding or complex treatment plan.

Estimate of Radiation Doses in MDCT Using Patient Weight (MDCT 검사에서 환자 체중을 이용한 선량 평가)

  • Kwon, Seong-Ohk;Dong, Kyung-Rae;Kweon, Dae-Cheol;Goo, Eun-Hoe;Choi, Ji-Won;Chung, Woon-Kwan
    • Progress in Medical Physics
    • /
    • v.21 no.3
    • /
    • pp.246-252
    • /
    • 2010
  • The purpose of this study provides measurements of radiation dose from MDCT of head, chest, abdomen and pelvic examinations. A series of dose quantities that are measured of patient weight to compare the dose received during MDCT examinations. Data collected included: weight together with CT dose descriptors, volume CT dose index (CTDIvol) and dose length product (DLP). The effective dose was also estimated and served as collective dose estimation data. Data from 1,774 adult patients attending for a CT examination of the head (n=520) or chest (n=531) or abdomen (n=724) was obtained from spiral CT units using a same CT protocol. Mean values of CTDIvol was a range of 48.6 mGy for head and 6.9, 10.5 mGy for chest, abdomen examinations, respectively. And mean values of DLP was range of 1,604 $mGy{\cdot}cm$ for head, 250 $mGy{\cdot}cm$ for chest, 575 $mGy{\cdot}cm$ for abdomen examinations, respectively. Mean effective dose values for head, chest, abdominal CT were 3.6, 4.2, and 8.6 mSv, respectively. The degree of CTDIvol and DLP was a positive correlation with weight. And there was a positive correlation for weight versus CTDIvol ($r^2$=0.62), DLP ($r^2$=0.694) in chest. And head was also positive correlation with weight versus CTDIvol ($r^2$=0.691), DLP ($r^2$=0.741). We conclude that CTDIvol and DLP is an important determinant of weight within the CT examinations. The results for this study suggest that CT protocol should be tailored according to patient weight.

Usefulness Evaluation of Algorithm Conversion Method for Dose Reduction in Brain CT Examination (두부 CT 검사에서 선량감소를 위한 알고리즘 변환방법의 유용성 평가)

  • Kim, Hyeon ju
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.3
    • /
    • pp.481-487
    • /
    • 2019
  • Based on the scan conditions and algorithms that are generally applied during examinations during head CT examinations, the results of dose reduction through the application of algorithm changes were investigated through experiments. As a result, the dose reduction effect was more meaningful for the change of perfusion than for the tube voltage, and the quality evaluation using the brain phantom was relatively less reduced when the dose was reduced after the application of the Bone algorithm, especially for the application of the Bone algorithm, and the deviation of the mean CT number or Pixel value was measured relatively significantly. In other words, the conditions under which dose was reduced and quality was maintained to reduce the patient's exposure dose and obtain images of the same quality were obtained with the application of the Smooth algorithm and the resulting values of 120 kVp, 160 mA. At this point, doses were reduced by about 28%, and the mean CT number or Pixel value was also measured with relatively little error. If the results are applied to patients who visit the hospital for examination or follow-up after applying various algorithms and follow up scan conditions, the results are considered to be very useful in reducing patient exposure dose.

Dose Distribution&Calibration in HDR Intracavitary Irradiation for Uterine Cervical Cancer (자궁경부암의 강내치료를 위한 선량측정)

  • 김진기;김정수;김형진;권형철
    • Progress in Medical Physics
    • /
    • v.6 no.1
    • /
    • pp.13-18
    • /
    • 1995
  • Dose distribution of HDR-RALS source represents an inverse square law as the distance. Difference of measurement value and calculation value according of brachytherapy. Therefore, in HDR-RALS dose calibration and calculation have an important effect in treatment of uterine cervical cancer and absorbed dose of interesting points. In intracavitary therapy, particula attention is paid for precise determination of the doses to be applied. In this report, we have discussed that the calibration of a HDR-RALS, differences between calculation dose use of isodose chart and measurement in rectum. Dose rate calibration of radiation sources are obtained from air kerma and Г factor with calibraed ion chamber for cobalt source. and used semiconductor detector for compared with measurement in phantom. Eighteen patients were treated with a HDR-RALS for intrcavitarty irradiation (ICR) using a cobalt-cesium source. Repoductivity of dose measurements were 0.3 -1.1% in phantom. The means of dose distribution was -6- +21% between calculation of isodose chart and measurement of recyum, and was same mean value upper 6.3% in measurement value than calculation does.

  • PDF

Measurement of Spatial Dose Distribution for evaluation operator dose during Neuro-interventional Procedures (두경부 질환의 인터벤션 시술 시 시술자의 피폭선량평가를 위한 공간선량측정에 관한 연구)

  • Han, Su-Chul;Hong, Dong-Hee
    • Journal of radiological science and technology
    • /
    • v.39 no.3
    • /
    • pp.323-328
    • /
    • 2016
  • The spatial dose distribution was measured with ionization chamber as preliminary study to evaluate operator dose and to study dose reduction during neuro-interventional procedures. The zone of operators was divided into four area (45, 135, 225, and 315 degree).We supposed that operator exist on the four area and indicated location of critical organs(eyes, breast, gonad). The spatial doses were measured depending on distance( 80, 100, 120, and 140 cm) and location of critical organs. The spatial doses of area of 225 degree were 114.5 mR/h (eyes location), 143.1 mR/h (breast location) and 147 mR/h (gonad location) in 80 cm. When changed location of x-ray generator, spatial dose increased in $18.1{\pm}10.5%$, averagely. We certified spatial dose in the operator locations, Using the results of this study, It is feasible to protect operator from radiation in neuro-interventional procedures.

Monte Carlo Simulation for the Measurement of Entrance Skin Dose on Newborn and Infants (영·유아의 입사피부선량 측정을 위한 몬테카를로 시뮬레이션)

  • Kim, Sang-Tae
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.6
    • /
    • pp.346-352
    • /
    • 2012
  • Radiation dose estimation on the newborn and infants during radiation examinations, unlike for the adults, is not actively being progressed. Therefore, as an index to present exposure dose during radiation examinations on newborn and infants, entrance skin dose was measured, and the result was compared with results of monte carlo simulation to raise reproducibility of entrance skin dose measurement, and it was proved that various geometry implementation was possible. The resulting values through monte carlo simulation was estimated using normalization factors for entrance skin dose to calibrate radiation dose and then normalized to a unit X ray radiation field size. Average entrance skin dose per one time exposure was $78.41{\mu}Gy$ and the percentage error between measurement by dosimeter and by monte carlo simulation was found to be -4.77%. Entrance skin dose assessment by monte carlo simulation provides possible alternative method in difficult entrance skin dose estimation for the newborn and infants who visit hospital for actual diagnosis.