• 제목/요약/키워드: 평가 영역

Search Result 6,368, Processing Time 0.047 seconds

A Study on the Psychosocial Characteristics and Quality of Life in Functional Gastrointestinal Disorders (기능성위장질환 환자들의 정신사회적 특성 및 삶의 질의 관계에 관한 연구)

  • Kim, So-Won;Jang, Seung-Ho;Ryu, Han-Seung;Choi, Suck-Chei;Rho, Seung-Ho;Lee, Sang-Yeol
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.27 no.1
    • /
    • pp.25-34
    • /
    • 2019
  • Objectives : This study aimed to compare the psychosocial characteristics among patients with functional gastrointestinal disorder (FGID), adults with functional gastrointestinal symptoms, and normal control group and investigate factors related to quality of life (QoL) of FGID patients. Methods : 65 patients diagnosed with FGID were selected. 79 adults were selected as normal control group based on the Rome III diagnostic criteria, and 88 adults who showed functional gastrointestinal symptoms were selected as "FGID positive group". Demographic factors were investigated. Psychosocial factors were evaluated using the Korean-Beck Depression Inventory-II, Korean-Beck Anxiety Inventory, Korean-Childhood Trauma Questionnaire, Multi-dimensional Scale of Perceived Social Support, Connor-Davidson Resilience Scale and WHO Quality of Life Assessment Instrument Brief Form. A one-way ANOVA was used to compare differences among groups. Pearson correlation test was used to analyze correlations between QoL and psychosocial factors in patients with FGID. Results : There were group differences in the education level. Depression (F=29.012, p<0.001), anxiety (F=27.954, p<0.001) and Childhood trauma (F=7.748, p<0.001) were significantly higher in FGID patient group than in both FGID-positive and normal control group. Social support (F=5,123, p<0.001), Resilience (F=9.623, p<0.001) and QoL (F=35.991, p<0.001) were significantly lower in the FGID patient group than in others. QoL of FGID patients showed a positive correlation with resilience (r=0.475, p<0.01), and showed a negative correlation with depression (r=-0.641, p<0.01), anxiety (r=-0.641, p<0.01), and childhood trauma (r=-0.278, p<0.05). Conclusions : FGID patients have distinctive psychosocial factors compared to the both FGID-positive and normal control group. Therefore, the active interventions for psychosocial factors are required in the treatment of patients with FGID.

A Study on the Treatment of Combine Electron Beam in the Treatment of Breast Cancer Tumor Bed (유방암 Tumor bed 치료 시 혼합 전자선 치료 방법에 대한 고찰)

  • Lee, Geon Ho;Kang, Hyo Seok;Choi, Byoung Joon;Park, Sang Jun;Jung, Da Ee;Lee, Du Sang;Ahn, Min Woo;Jeon, Myeong Soo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.1
    • /
    • pp.51-56
    • /
    • 2019
  • Purpose: The usefulness of using single-electron radiation for secondary radiotherapy of breast cancer patients after surgery is assessed and the use of a combine of different energy. Methods and materials : In this study, 40 patients (group A) using energy 6 MeV and 9 MeV, and 19 patients (group B) using a combine of 9 MeV and 12 MeV were studied among 59 patients who performed secondary care using combine electronic radiation. Each patient in each group, 6 MeV, 9 MeV, Combine(6 MeV / 9 MeV) and 9 MeV, 12 MeV, Combine (9 MeV / 12 MeV) were developed in different ways, and the maximum doses delivered to the original hospital, D95, D5, and $V_3$, $V_5$, $V_{10}$ were compared. Result: The D95 mean value of Group A treatment plan was $785.33{\pm}225.37cGy$, $1121.79{\pm}87.02cGy$ at 9 MeV, and $1010.98{\pm}111.17cGy$ at 6 MeV / 9 MeV, and the mean value at 6 MeV / 9 MeV was most appropriate for the dose. The mean values of the low dose area $V_3$ and $V_5$ in the lung of the breast direction being treated were $3.24{\pm}3.49%$ and $0.72{\pm}1.55%$ at 6 MeV, the highest 9 MeV at $7.25{\pm}4.59%$, $3.07{\pm}2.64%$, the lowest at 6 MeV. Maximum and average lung dose was $727.78{\pm}137.27cGy$ at 6 MeV / 9 MeV, $49.16{\pm}24.44cGy$, highest 9 MeV at $998.97{\pm}114.35cGy$, $85.33{\pm}41.18cGy$, and lowest 6 MeV at $387.78{\pm}208.88cGy$, $9.27{\pm}6.60cGy$. The value of $V_{10}$ was all close to zero. Group B appeared in the pattern of Group A. Conclusion: Relative differences in low-dose areas of the lungs $V_3$ and $V_5$ were seen and were most effective in the dose transfer of tumor bed in the application of combined energy. It is thought that the method of using electronic energy in further radiation treatments for breast cancer is a more effective way to use the energy effect of limiting energy resources, and that if you think about it again, it could be a little more beneficial radiation treatment for patients.

Evaluation of the Neural Fiber Tractography Associated with Aging in the Normal Corpus Callosum Using the Diffusion Tensor Imaging (DTI) (확산텐서영상(Diffusion Tensor Imaging)을 이용한 정상 뇌량에서의 연령대별 신경섬유로의 변화)

  • Im, In-Chul;Goo, Eun-Hoe;Lee, Jae-Seung
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.4
    • /
    • pp.189-194
    • /
    • 2011
  • This study used magnetic resonance diffusion tensor imaging (DTI) to quantitatively analyze the neural fiber tractography according to the age of normal corpus callosum and to evaluate of usefulness. The research was intended for the applicants of 60 persons that was in a good state of health with not brain or other disease. The test parameters were TR: 6650 ms, TE: 66 ms, FA: $90^{\circ}$, NEX: 2, thickness: 2 mm, no gap, FOV: 220 mm, b-value: $800s/mm^2$, sense factor: 2, acquisition matrix size: $2{\times}2{\times}2mm^3$, and the test time was 3 minutes 46 seconds. The evaluation method was constructed the color-cored FA map include to the skull vertex from the skull base in scan range. We set up the five ROI of corpus callosum of genu, anterior-mid body, posterior-mid body, isthmus, and splenium, tracking, respectively, and to quantitatively measured the length of neural fiber. As a result, the length of neural fiber, for the corpus callosum of genu was 20's: $61.8{\pm}6.8$, 30's: $63.9{\pm}3.8$, 40's: $65.5{\pm}6.4$, 50's: $57.8{\pm}6.0$, 60's: $58.9{\pm}4.5$, more than 70's: $54.1{\pm}8.1mm$, for the anterior-mid body was 20's: $54.8{\pm}8.8$, 30's: $58.5{\pm}7.9$, 40's: $54.8{\pm}7.8$, 50's: $56.1{\pm}10.2$, 60's: $48.5{\pm}6.2$, more than 70's: $48.6{\pm}8.3mm$, for the posterior-mid body was 20's: $72.7{\pm}9.1$, 30's: $61.6{\pm}9.1$, 40's: $60.9{\pm}10.5$, 50's: $61.4{\pm}11.7$, 60's: $54.9{\pm}10.0$, more than 70's: $53.1{\pm}10.5mm$, for the isthmus was 20's: $71.5{\pm}17.4$, 30's: $74.1{\pm}14.9$, 40's: $73.6{\pm}14.2$, 50's: $66.3{\pm}12.9$, 60's: $56.5{\pm}11.2$, more than 70's: $56.8{\pm}11.3mm$, and for the splenium was 20's: $82.6{\pm}6.8$, 30's: $86.9{\pm}6.4$, 40's: $83.1{\pm}7.1$, 50's: $81.5{\pm}7.4$, 60's: $78.6{\pm}6.0$, more than 70's: $80.55{\pm}8.6mm$. The length of neural fiber for normal corpus callosum were statistically significant in the genu(P=0.001), posterior-mid body(P=0.009), and istumus(P=0.012) of corpus callosum. In order of age, the length of neural fiber increased from 30s to 40s, as one grows older tended to decrease. For this reason, the nerve cells of brain could be confirmed through the neural fiber tractography to progress actively in middle age.

Ultrasonographic study on the masseter muscle thickness of adult Korean (한국인 성인의 교근 두께에 관한 초음파검사적 연구)

  • Cha, Bong-Kuen;Park, In-Woo;Lee, Yeun-Hee
    • The korean journal of orthodontics
    • /
    • v.31 no.2 s.85
    • /
    • pp.225-236
    • /
    • 2001
  • It is widely accepted that the shape and structure of bone are closely related to the activity of attached muscle. Numerous clinical and animal experimental studies indicated the significant effects of masticatory muscle function on maxillofacial morphology. Recently, the development of ultrasonography has spread throughout different fields of medicine. In the clinical examinations, ultrasonography is a convenient, inexpensive technique to apply with accurate and reliable results. The aim of this study is to assess the thickness of the masseter muscle and its correlation to maxillofacial skeleton by examining 35 male and 15 female dental students at Kangnung National University. The masseter muscle thickness of the subjects were measured by ultrasonographic scanning with a 7.5MHz linear probe, and their maxillofacial morphology were investigated by lateral cephalometric radiographs. The relationship between the masseter muscle thickness and maxillofacial morphology of normal adult was statistically analyzed, and the following results were obtained. 1. The average thickness of male masseter muscle was 13.8${\pm}$1.71mm in the relaxed state and 14.8${\pm}$1.77mm at maximal clenching state, while that of female was 11.6${\pm}$1.58mm and 12.4${\pm}$1.47mm, respectively. Ethnic difference in thickness of the masseter muscle and maxillofacial skeleton was found when the results of many researchers were compared with those of this study. 2. The thickness of the masseter muscle in both sexes increased significantly at maximal clenching state than in relaxed state(P<0.05). 3. The masseter muscle thickness of male was greater than that of female both in the relaxed state and maximal clenching states(P<0.05). 4. In males, the thickness of the masseter muscle was negatively correlated with the mandibular plane angle and positively correlated with the mandibular ramus height and anterior cranial base length(P<0.05). It may suggest that the male with thicker masseter muscle has smaller facial divergence. 5. No significant correlation was found between the masseter muscle thickness and maxillofacial morphology in females(P<0.05). Therefore, these data suggest that ultrasonography can add valuable information to the conventional examinations of masseter muscle function.

  • PDF

Usefulness Evaluation of Open Mouth View when PET/CT scan In Tongue Cancer Patients (Tongue Cancer 환자에서 PET/CT 검사 시 Open Mouth 촬영법의 유용성 평가)

  • Kim, Jae Hwan;Yun, Jong Jun;Jung, Ji Wook;Kim, Jung Wook;Hwang, Ju Won;Ji, Hye In
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.14-20
    • /
    • 2016
  • Purpose Tongue cancer is 1.8% of all cancer tumors occur in the tongue, it is known that the high incidence enough to account for 75% of oral cancer conducted a PET / CT examination for early diagnosis, metastasis, staging, etc. and. Tongue when PET / CT scan of a cancer patient and a Torso taken to close mouth lesions if the condition was caused due to the overlapping or corresponding artifacts are not clearly observed. The purpose of this study is to evaluate the changes that occur during PET / CT scan with open mouth and its usefulness under. Materials and Methods From June 2015 to March 2016 complained of herein by May 21 had received a diagnosis of tongue cancer underwent PET / CT scan patients were treated with a target (16 males, 5 female). The first was taken to close mouth Torso state, it was taken to add 1 bed open mouth condition. Tumor (T), measuring the Normal Tongue (NT), Lymph Node (LN) standard intake coefficient by setting a region of interest in the (standardized uptake value, SUV) SUVmean, the average value was measured SUVmax, drawn to each region of interest 3 times and Background (Carotid artery) was out of the SUV. In Chapter 3 of the slice to the tumor clearly visible by setting the region of interest to measure the change Tumor size was calculated average value. Gross Image resolution assessment were analyzed statistically through were divided into 1-5 points by the Radiation 7 people in 2, more than five years worked in specialized nuclear medicine compare to proceed with the blind test nonparametric test (wilcoxon signed rank test). (SPSS ver.18) Results $SUV_{mean}$ T's were in close mouth $5.01{\pm}2.70$ with open mouth $5.48{\pm}2.88$ (P<0.05), $SUV_{max}$ were respectively $8.78{\pm}5.55$ and $9.70{\pm}5.99$ (P<0.05). $SUV_{mean}$ in the NT were respectively $0.43{\pm}0.30$ and $0.34{\pm}0.24$ (P=0.20), $SUV_{max}$ was $0.56{\pm}0.34$ and $0.45{\pm}0.25$ (P=0.204). LN $SUV_{mean}$ were respectively $1.62{\pm}1.43$ and $1.69{\pm}1.49$ (P=0.161), $SUV_{mean}$ was $2.09{\pm}1.88$ and $1.99{\pm}1.74$ (P=0.131). Tumor size change is close mouth $4.96{\pm}4.66cm^2$ $5.33{\pm}4.64cm^2$ with 7.45% increase was (P<0.05), gross image resolution evaluation is $2.87{\pm}0.73$, $3.77{\pm}0.68$ with open mouth examinations 30.5% increase was (P<0.05). Conclusion Tumor SUV on the changes that had an increase in open mouth during inspection, the normal tongue and lymph node, but there was no significant difference in the change slightly. It is also one open mouth PET / CT scan will provide improved image to all patients with tongue cancer, but it could be confirmed that similar overall through the blind test, or tumor size changes and showing a high resolution image. It can be the perfect alternative method for problems that occur when the close mouth Open mouth PET / CT scan, but is believed to be through the open mouth to observe the boundary of overlapping or tumor of the oral cavity other structures a little more clearly. Tongue cancer patients how to recommend that the shooting further open mouth PET / CT.

  • PDF

The efficacy of continuous positive airway pressure (CPAP) for patient with left breast cancer (좌측 유방암 방사선치료에서 CPAP(Continuous Positive Airway Pressure)의 유용성 평가)

  • Jung, Il Hun;Ha, Jin Sook;Chang, Won Suk;Jeon, Mi Jin;Kim, Sei Joon;Jung, Jin Wook;Park, Byul Nim;Shin, Dong Bong;Lee, Ik Jae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.2
    • /
    • pp.43-49
    • /
    • 2019
  • Purpose: This study examined changes in the position of the heat and lungs depending on the patient's breathing method during left breast cancer radiotherapy and used treatment plans to compare the resulting radiation dose. Materials and methods: The participants consisted of 10 patients with left breast cancer. A CT simulator(SIMENS SOMATOM AS, Germany) was used to obtain images when using three different breathing methods: free breathing(FB), deep inspiration breath hold(DIBH with Abches, DIBH), inspiration breath hold(IBH with CPAP, CPAP). A Ray Station(5.0.2.35, Sweden) was used for treatment planning, the treatment method was volumetric modulated arc therapy (VMAT) with one partial arc of the same angle, and the prescribed dose to the planning target volume (PTV) was a total dose of 50Gy(2Gy/day). In treatment plan analysis, the 95% dose (D95) to the PTV, the conformity index(CI), and the homogeneity index (HI) were compared. The lungs, heart, and left anterior descending artery (LAD) were selected as the organs at risk(OARs). Results: The mean volume of the ipsilateral lung for FB, DIBH, and CPAP was 1245.58±301.31㎤, 1790.09±362.43 ㎤, 1775.44±476.71 ㎤. The mean D95 for the PTV was 46.67±1.89Gy, 46.85±1.72Gy, 46.97±23.4Gy, and the mean CI and HI were 0.95±0.02, 0.96±0.02, 0.95±0.02 and 0.91±0.01, 0.90±0.01, 0.92±0.02. The V20 of Whole Lung was 10.74±4.50%, 8.29±3.14%, 9.12±3.29% and The V20 of the ipsilateral lung was 20.45±8.65%, 17.18±7.04%, 18.85±7.85%, the Dmean of the heart was 7.82±1.27Gy, 6.10±1.27Gy, 5.67±1.56Gy, and the Dmax of the LAD was 20.41±7.56Gy, 14.88±3.57Gy, 14.96±2.81Gy. The distance from the thoracic wall to the LAD was measured to be 11.33±4.70mm, 22.40±6.01mm, 20.14±6.23mm. Conclusion: During left breast cancer radiotherapy, the lung volume was 46.24% larger for DIBH than for FB, and 43.11% larger for CPAP than FB. The larger lung volume increases the distance between the thoracic wall and the heart. In this way, the LAD, which is one of the nearby OARs, can be more effectively protected while still satisfying the treatment plan. The lung volume was largest for DIBH, and the distance between the LAD and thoracic wall was also the greatest. However, when performing treatment with DIBH, the intra-fraction error cannot be ignored. Moreover, communication between the patient and the radiotherapist is also an important factor in DIBH treatment. When communication is problematic, or if the patient has difficulty holding their breath, we believe that CPAP could be used as an alternative to DIBH. In order to verify the clinical efficacy of CPAP, it will be necessary to perform long-term follow-up of a greater number of patients.

Dosimetry of the Low Fluence Fast Neutron Beams for Boron Neutron Capture Therapy (붕소-중성자 포획치료를 위한 미세 속중성자 선량 특성 연구)

  • Lee, Dong-Han;Ji, Young-Hoon;Lee, Dong-Hoon;Park, Hyun-Joo;Lee, Suk;Lee, Kyung-Hoo;Suh, So-Heigh;Kim, Mi-Sook;Cho, Chul-Koo;Yoo, Seong-Yul;Yu, Hyung-Jun;Gwak, Ho-Shin;Rhee, Chang-Hun
    • Radiation Oncology Journal
    • /
    • v.19 no.1
    • /
    • pp.66-73
    • /
    • 2001
  • Purpose : For the research of Boron Neutron Capture Therapy (BNCT), fast neutrons generated from the MC-50 cyclotron with maximum energy of 34.4 MeV in Korea Cancer Center Hospital were moderated by 70 cm paraffin and then the dose characteristics were investigated. Using these results, we hope to establish the protocol about dose measurement of epi-thermal neutron, to make a basis of dose characteristic of epi-thermal neutron emitted from nuclear reactor, and to find feasibility about accelerator-based BNCT. Method and Materials : For measuring the absorbed dose and dose distribution of fast neutron beams, we used Unidos 10005 (PTW, Germany) electrometer and IC-17 (Far West, USA), IC-18, ElC-1 ion chambers manufactured by A-150 plastic and used IC-l7M ion chamber manufactured by magnesium for gamma dose. There chambers were flushed with tissue equivalent gas and argon gas and then the flow rate was S co per minute. Using Monte Carlo N-Particle (MCNP) code, transport program in mixed field with neutron, photon, electron, two dimensional dose and energy fluence distribution was calculated and there results were compared with measured results. Results : The absorbed dose of fast neutron beams was $6.47\times10^{-3}$ cGy per 1 MU at the 4 cm depth of the water phantom, which is assumed to be effective depth for BNCT. The magnitude of gamma contamination intermingled with fast neutron beams was $65.2{\pm}0.9\%$ at the same depth. In the dose distribution according to the depth of water, the neutron dose decreased linearly and the gamma dose decreased exponentially as the depth was deepened. The factor expressed energy level, $D_{20}/D_{10}$, of the total dose was 0.718. Conclusion : Through the direct measurement using the two ion chambers, which is made different wall materials, and computer calculation of isodose distribution using MCNP simulation method, we have found the dose characteristics of low fluence fast neutron beams. If the power supply and the target material, which generate high voltage and current, will be developed and gamma contamination was reduced by lead or bismuth, we think, it may be possible to accelerator-based BNCT.

  • PDF

Study on Current Curriculum Analysis of Clinical Dental Hygiene for Dental Hygiene Students in Korea (국내 치위생(학)과 임상치위생학 교육과정 운영현황 분석)

  • Choi, Yong-Keum;Han, Yang-Keum;Bae, Soo-Myoung;Kim, Jin;Kim, Hye-Jin;Ahn, Se-Youn;Lim, Kun-Ok;Lim, Hee Jung;Jang, Sun-Ok;Jang, Yun-Jung;Jung, Jin-Ah;Jeon, Hyun-Sun;Park, Ji-Eun;Lee, Hyo-Jin;Shin, Bo-Mi
    • Journal of dental hygiene science
    • /
    • v.17 no.6
    • /
    • pp.523-532
    • /
    • 2017
  • The purpose of this study was to provide basic data to standardize the clinical dental hygiene curriculum, based on analysis of current clinical dental hygiene curricula in Korea. We emailed questionnaires to 12 schools to investigate clinical dental hygiene curricula, from February to March, 2017. We analyzed the clinical dental hygiene curricula in 5 schools with a 3-year program and in 7 schools with a 4-year program. The questionnaire comprised nine items on topics relating to clinical dental hygiene, and four items relating to the dental hygiene process and oral prophylaxis. The questionnaire included details regarding the subject name, the grade/semester/credit system, course content and class hours, the number of senior professors, and the number of patients available for dental hygiene clinical training purposes. In total, there were 96 topics listed in the curricula relating to clinical dental hygiene training, and topics varied between the schools. There was an average of 20.4 topic credits, and more credits and hours were allocated to the 4-year program than to the 3-year program. On average, the ratio of students to professors was 21.4:1. Course content included infection control, concepts for dental hygiene processes, dental hygiene assessment, intervention and evaluation, case studies, and periodontal instrumentation. An average of 2 hours per patient was spent on dental hygiene practice, with an average of 1.9 visits. On average, student clinical training involved 19 patients and 26.6 patients in the 3-year and 4-year programs, respectively. The average participation time per student per topic was 38.0 hours and 53.1 hours, in the 3-year and 4-year programs, respectively. Standardizing the clinical dental hygiene curricula in Korea will require consensus guidelines on topics, the number of classes required to achieve core competencies as a dental hygienist, and theory and practice time.

The Audience Behavior-based Emotion Prediction Model for Personalized Service (고객 맞춤형 서비스를 위한 관객 행동 기반 감정예측모형)

  • Ryoo, Eun Chung;Ahn, Hyunchul;Kim, Jae Kyeong
    • Journal of Intelligence and Information Systems
    • /
    • v.19 no.2
    • /
    • pp.73-85
    • /
    • 2013
  • Nowadays, in today's information society, the importance of the knowledge service using the information to creative value is getting higher day by day. In addition, depending on the development of IT technology, it is ease to collect and use information. Also, many companies actively use customer information to marketing in a variety of industries. Into the 21st century, companies have been actively using the culture arts to manage corporate image and marketing closely linked to their commercial interests. But, it is difficult that companies attract or maintain consumer's interest through their technology. For that reason, it is trend to perform cultural activities for tool of differentiation over many firms. Many firms used the customer's experience to new marketing strategy in order to effectively respond to competitive market. Accordingly, it is emerging rapidly that the necessity of personalized service to provide a new experience for people based on the personal profile information that contains the characteristics of the individual. Like this, personalized service using customer's individual profile information such as language, symbols, behavior, and emotions is very important today. Through this, we will be able to judge interaction between people and content and to maximize customer's experience and satisfaction. There are various relative works provide customer-centered service. Specially, emotion recognition research is emerging recently. Existing researches experienced emotion recognition using mostly bio-signal. Most of researches are voice and face studies that have great emotional changes. However, there are several difficulties to predict people's emotion caused by limitation of equipment and service environments. So, in this paper, we develop emotion prediction model based on vision-based interface to overcome existing limitations. Emotion recognition research based on people's gesture and posture has been processed by several researchers. This paper developed a model that recognizes people's emotional states through body gesture and posture using difference image method. And we found optimization validation model for four kinds of emotions' prediction. A proposed model purposed to automatically determine and predict 4 human emotions (Sadness, Surprise, Joy, and Disgust). To build up the model, event booth was installed in the KOCCA's lobby and we provided some proper stimulative movie to collect their body gesture and posture as the change of emotions. And then, we extracted body movements using difference image method. And we revised people data to build proposed model through neural network. The proposed model for emotion prediction used 3 type time-frame sets (20 frames, 30 frames, and 40 frames). And then, we adopted the model which has best performance compared with other models.' Before build three kinds of models, the entire 97 data set were divided into three data sets of learning, test, and validation set. The proposed model for emotion prediction was constructed using artificial neural network. In this paper, we used the back-propagation algorithm as a learning method, and set learning rate to 10%, momentum rate to 10%. The sigmoid function was used as the transform function. And we designed a three-layer perceptron neural network with one hidden layer and four output nodes. Based on the test data set, the learning for this research model was stopped when it reaches 50000 after reaching the minimum error in order to explore the point of learning. We finally processed each model's accuracy and found best model to predict each emotions. The result showed prediction accuracy 100% from sadness, and 96% from joy prediction in 20 frames set model. And 88% from surprise, and 98% from disgust in 30 frames set model. The findings of our research are expected to be useful to provide effective algorithm for personalized service in various industries such as advertisement, exhibition, performance, etc.

Quality Assurance for Intensity Modulated Radiation Therapy (세기조절방사선치료(Intensity Modulated Radiation Therapy; IMRT)의 정도보증(Quality Assurance))

  • Cho Byung Chul;Park Suk Won;Oh Do Hoon;Bae Hoonsik
    • Radiation Oncology Journal
    • /
    • v.19 no.3
    • /
    • pp.275-286
    • /
    • 2001
  • Purpose : To setup procedures of quality assurance (OA) for implementing intensity modulated radiation therapy (IMRT) clinically, report OA procedures peformed for one patient with prostate cancer. Materials and methods : $P^3IMRT$ (ADAC) and linear accelerator (Siemens) with multileaf collimator are used to implement IMRT. At first, the positional accuracy, reproducibility of MLC, and leaf transmission factor were evaluated. RTP commissioning was peformed again to consider small field effect. After RTP recommissioning, a test plan of a C-shaped PTV was made using 9 intensity modulated beams, and the calculated isocenter dose was compared with the measured one in solid water phantom. As a patient-specific IMRT QA, one patient with prostate cancer was planned using 6 beams of total 74 segmented fields. The same beams were used to recalculate dose in a solid water phantom. Dose of these beams were measured with a 0.015 cc micro-ionization chamber, a diode detector, films, and an array detector and compared with calculated one. Results : The positioning accuracy of MLC was about 1 mm, and the reproducibility was around 0.5 mm. For leaf transmission factor for 10 MV photon beams, interleaf leakage was measured $1.9\%$ and midleaf leakage $0.9\%$ relative to $10\times\;cm^2$ open filed. Penumbra measured with film, diode detector, microionization chamber, and conventional 0.125 cc chamber showed that $80\~20\%$ penumbra width measured with a 0.125 cc chamber was 2 mm larger than that of film, which means a 0.125 cc ionization chamber was unacceptable for measuring small field such like 0.5 cm beamlet. After RTP recommissioning, the discrepancy between the measured and calculated dose profile for a small field of $1\times1\;cm^2$ size was less than $2\%$. The isocenter dose of the test plan of C-shaped PTV was measured two times with micro-ionization chamber in solid phantom showed that the errors upto $12\%$ for individual beam, but total dose delivered were agreed with the calculated within $2\%$. The transverse dose distribution measured with EC-L film was agreed with the calculated one in general. The isocenter dose for the patient measured in solid phantom was agreed within $1.5\%$. On-axis dose profiles of each individual beam at the position of the central leaf measured with film and array detector were found that at out-of-the-field region, the calculated dose underestimates about $2\%$, at inside-the-field the measured one was agreed within $3\%$, except some position. Conclusion : It is necessary more tight quality control of MLC for IMRT relative to conventional large field treatment and to develop QA procedures to check intensity pattern more efficiently. At the conclusion, we did setup an appropriate QA procedures for IMRT by a series of verifications including the measurement of absolute dose at the isocenter with a micro-ionization chamber, film dosimetry for verifying intensity pattern, and another measurement with an array detector for comparing off-axis dose profile.

  • PDF