Invivo Dosimetry for Mammography with and without Lead Apron Using the Glass Dosimeters (유방촬영술에서 유리선량계를 이용한 납치마의 선량차폐 효과 측정)

  • Yu, Su-Jeong;Lim, Sangwook;Ma, Sun Young;Seo, Sun-Youl;Kim, Young-Jae;Kang, Young-Nam;Keum, Ki Chang;Cho, Samju
    • Progress in Medical Physics
    • /
    • v.26 no.2
    • /
    • pp.93-98
    • /
    • 2015
  • The purpose of this study is to see the usefulness of lead apron for critical organs near the breast under examining. For clinical experiment, 30 female volunteers who agreed to their participation in the experiments, were chosen and divided into two groups, 15 in group A and 15 in group B respectively. group A is to see whether each side of breast under mammography affects to other side glandular on the critical organs is same, because it is not allowed to scan the both breast for same person or to scan repeatedly. Group B is to see the effectiveness of lead apron during the mammography of right breast. Glass dosimeters were placed on the thyroid, the contralateral breast, and lower abdomen where near the breast during examining. The average glandular doses on the surface in mammography of the thyroid gland, the contralateral breast, the lower abdomen were 0.0692 mGy, 0.6790 mGy, and 0.0122 mGy, respectively, which was an extremely low level of glandular dose. In group B, as to the thyroid gland, average dose was decreased from 0.0922 mGy to 0.0158 mGy. The average dose of contralateral breast was decreased from 0.8575 mGy to 0.0286 mGy. The average doses of lower abdomen was decrease 0.0150 mGy to 0.0173 mGy. As to the lower abdomen, dose decreased from 0.0150 mGy before the use of an apron down to 0.0173 mGy after the use. As p-value was under 0.05, statistically significant difference was observed between the two groups. Wearing an apron can have the protective effects on the thyroid gland up to 20 times lower than not wearing one. Besides, it is also necessary to protect the other breast during the examination by wearing one.

The Feasibility Study of MRI-based Radiotherapy Treatment Planning Using Look Up Table (Look Up Table을 이용한 자기공명영상 기반 방사선 치료계획의 타당성 분석 연구)

  • Kim, Shin-Wook;Shin, Hun-Joo;Lee, Young-Kyu;Seo, Jae-Hyuk;Lee, Gi-Woong;Park, Hyeong-Wook;Lee, Jae-Choon;Kim, Ae-Ran;Kim, Ji-Na;Kim, Myong-Ho;Kay, Chul-Seung;Jang, Hong-Seok;Kang, Young-Nam
    • Progress in Medical Physics
    • /
    • v.24 no.4
    • /
    • pp.237-242
    • /
    • 2013
  • In the intracranial regions, an accurate delineation of the target volume has been difficult with only the CT data due to poor soft tissue contrast of CT images. Therefore, the magnetic resonance images (MRI) for the delineation of the target volumes were widely used. To calculate dose distributions with MRI-based RTP, the electron density (ED) mapping concept from the diagnostic CT images and the pseudo CT concept from the MRI were introduced. In this study, the look up table (LUT) from the fifteen patients' diagnostic brain MRI images was created to verify the feasibility of MRI-based RTP. The dose distributions from the MRI-based calculations were compared to the original CT-based calculation. One MRI set has ED information from LUT (lMRI). Another set was generated with voxel values assigned with a homogeneous density of water (wMRI). A simple plan with a single anterior 6MV one portal was applied to the CT, lMRI, and wMRI. Depending on the patient's target geometry for the 3D conformal plan, 6MV photon beams and from two to five gantry portals were used. The differences of the dose distribution and DVH between the lMRI based and CT-based plan were smaller than the wMRI-based plan. The dose difference of wMRI vs. lMRI was measured as 91 cGy vs. 57 cGy at maximum dose, 74 cGt vs. 42 cGy at mean dose, and 94 cGy vs. 53 at minimum dose. The differences of maximum dose, minimum dose, and mean dose of the wMRI-based plan were lower than the lMRI-based plan, because the air cavity was not calculated in the wMRI-based plan. These results prove the feasibility of the lMRI-based planning for brain tumor radiation therapy.

Diffusion-Weighted MR Imaging of Various Intracranial Diseases : Clinical Utility (다양한 두개강내 질환의 확산강조 자기공명영상 : 임상적 유용성)

  • 김영준
    • Investigative Magnetic Resonance Imaging
    • /
    • v.2 no.1
    • /
    • pp.104-112
    • /
    • 1998
  • Purpose : To evaluate the clinical utility of diffusion-weighted imaging by analyzing the signal intersity of lesions in patients with various intracranial diseases. Materials and Methods : difusion-weighted MR imaging was prospectively perormed in randomly selected 70 patients with various intracranial idseases. They consisted of 20 patients with acute infarct, 21 patients with chronic infarct of small vessel disease, 14 patients with primary intracranial tumor, three patients with brain metastasis, five patient with brain abscess, five patients with brain abscess, five patients with cerebral hemorrhage, one patient with neurocysticercosis, and one patient with epidermoid cyst. the diffusion-weighted images were obtained immediately after routine T2-weighted imaging on a 1.5T MR unit using single shot spin echo EPI technique with 6500 ms TR, 107ms TE, $128{\times}128$ matrix, 1 number of excitation, $24{\times}24$ field of view, 5-7 mm slice thickness, 2-3 mm inter-slice gap. The diffusion-gradients (b value of ($1000s{\;}/{\;}textrm{mm}^2$)) were applied along three directions(x, y, z). On visual inspection of diffusion-weighted images, the signal intersity of lesions was arbitrarily graded as one of 5 grades. In quantitative assessment, we measured the signal intensity of all the lesions and the contralateral corresponding normal area using round region of interest(ROI), and then calculated the signal intensity ratio of the lesion to the normal brain parenchyma. Results : On visual inspection, markedly hyperintense signals were seen in all cases of acute infarct, brain abscess, epidermoid cyst, and neurocysticercosis in degenerating stage. In all cases of cerebral hematoma, the very high signal internsity was intermingled with low signal intensity. focal very high signal intersity was also seen in a solid portion of the tumor in a patient. the mean signal intensity ratios of all those lesions to the normal brain parenchyma were above 2.5. Gliosis, solid component of brain tumor, brain metastasis, and vasogenic dedma appeared isointense to the normal brain parenchyma in 71%, 64%, 100%, and 67%, respectively ; the mean signal intensity ratios of those lesions to the normal brain parenchyma ranged 1.15 to 1.28 and there was no significant difference among these(p>0.1). Cystic cerebromalacia and necrotic or cystic portions in tumor were markedly or slightly hypointense, and the mean signal intensity ratios were 0.45 and 0.42, respectively. Conclusion : Very high signal intensity of acute infarct, brain abscess, epidermoid cyst, and cystic neurocysticercosis in degenerating stage on diffusion-weighted images may be helpful in differentiating from other diseases that are hypointense or isointense to the normal brain parenchyma. It may be especially useful differentiation of brain abscess from brain tumor with necrotic or cystic portion.

  • PDF

ORTHODONTIC BRACKET SHEAR BOND STRENGTH TO Nd:YAG LASER Er:YAG LASER IRRADIATED ENAMEL (Nd : YAG 및 Er : YAG 레이저로 치아표면 조사시 브라켓 전단접착강도에 관한 실험적 연구)

  • Choi, Seung-Hoon;Yang, Won-Sik
    • The korean journal of orthodontics
    • /
    • v.27 no.1
    • /
    • pp.141-155
    • /
    • 1997
  • The purpose of this study was to evaluate the effectiveness of the Nd:YAG laser and the Er:YAAG laser on etching enamel for direct bonding of orthodontic bracket. The advantages of laser etching rather than conventional acid etching are to reduce the subsurface demineralization rate, to inhibit the spillage of acid onto uninvolved ""its of enamel, and to save the clinical manipulation time involving drying, trashing and drying again. 189 freshly extracted human premolars were prepared for this research. 165 out of them were divided into 11 groups of 15 teeth. One group was acid etching and the rest groups were irradiated with Nd:YAG laser by four different energy levels(100mj 10pps, 100mj 20pps, 150mj 20pps, 200mj 20pps) and with Er:YAG laser by six different energy levels(60mj 5pps, 60mj 10pps, 100mj 10pps. 200mj 10pps, 200mj l5pps, 400mj 10pps). Shear bond strength was tested with Instron after 24 hours, one week, and three weeks. Twenty-four out of 189 teeth were divided into twelve groups untreated control, acid etching, and ten laser irradiation subgroups. And the ultrastructural enamel surfaces of each group were observed with scanning electron microscope. The results were as follows; 1. The means and the standard deviations of shear bond strength of Nd:YAG and Er:YAU laser irradiation by different energy levels were obtained. 2. Shear bond strengths of Er:YAG laser irradiation groups were higher than those of Nd:YAG laser irradiation groups at the identical energy level. 3. Maximum bond strengths was achieved at the energy of I50mj, 20pps in Nd:YAG laser irradiation groups or 60mj, 10pps in Er:YAG laser irradiation groups. 4. It was acceptible for direct bonding to irradiate lb0mj 20pps with Nd:YAG laser or to irradiate 60mj 10pps with Er:YAG laser considering the results of shear bond strength tests and SEM obsesvation.

  • PDF

The Evaluation of Bone Scan and SPECT Before and After Treatment of TMD Patients (골관절염을 가진 측두하악장애 환자의 치료 전, 후 골스캔과 SPECT의 평가)

  • Kim, Byeong-Soo;Ahn, Yong-Woo;Ko, Myung-Yun;Park, June-Sang
    • Journal of Oral Medicine and Pain
    • /
    • v.30 no.1
    • /
    • pp.57-67
    • /
    • 2005
  • The aim of this study was to evaluate bone scan(SUR) and SPECT(hot spot) in patients with TMJ osteoarthritis. 99mTc-MDP bone scan and SPECT were done in 27 patients, total 54 temporomandibular joints were examined with clinical examination, plain radiography. 42 TMJs were osteoarthritis and 12 TMJs were normal case, clinically diagnosed. We compared osteoarthritis group and control group of bone scan(SUR) and SPECT(hot spot). thus we compared before and after treatment of bone scan(SUR) and bone SPECT(hot spot) according to history, contributing factor, symptom degree, treatment, treatment period. The obtained results were as follows. 1. Bone scan(SUR) and SPECT(hot spot) activity of osteoarthritis group were higher than control group(P<0.05, P<0.01). 2. Bone scan(SUR) and SPECT(hot spot) activity were decreased after treatment at TMJ with osteoarthritis(P<0.01). 3. Bone scan(SUR) and SPECT(hot spot) activity were decreased at treatment group with splint(P<0.01, P<0.05). 4. Bone scan(SUR) and SPECT(hot spot) activity were decreased at Chronic group(P<0.01, P<0.05). 5. Bone scan(SUR) and SPECT(hot spot) activity were decreased at low noise NAS(<6) group(P<0.01,P<0.05). 6. Bone scan(SUR) and SPECT(hot spot) activity were decreased at TMD patient with parafunctional habit and without trauma history, psychosocial factor. 7. Bone scan(SUR) and SPECT(hot spot) activity were higher at before treatment required more treatment period.

EVALUATION ON THE ABRASION RESISTANCE OF A SURFACE SEALANT (레진전색제의 마모저항성에 대한 평가)

  • Kim, Soo-Mee;Han, Sae-Hee;Cho, Young-Gon
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.3
    • /
    • pp.180-190
    • /
    • 2007
  • The purpose of this study was to evaluate the abrasion resistance of surface penetrating sealant which was applied on a composite resin restoration and to provide proper time to reapply sealant on composite resin surface. Two hundred rectangular specimens, sized $8\times3\times2mm$, were made of Micronew (Bisco, Inc., Schaumburg, IL, U.S.A) and divided into two groups; F group (n = 10) was finished with coarse and medium grit of Sof-Lex discs and BisCoverwas applied B group (n = 190) after finishing with discs. B group was again subdivided into nineteen subgroups From B-1 group to B-18 group were subjected to toothbrush abrasion test using a distilled water-dentifrice slurry and toothbrush heads B-IM group was not subjected to toothbrush abrasion test. Average surface roughness (Ra) of each group was calculated using a surface roughness tester (Surfcorder MSE-1700: Kosaka Laboratory Ltd., Tokyo, Japan) . A representative specimen of each group was examined by FE-SEM (S-4700: Hitachi High Technologies Co., Tokyo, Japan). The data were analysed using cluster analysis, paired t-test, and repeated measure ANOVA. The results of this study were as follows; 1. Ra off group was $0.898{\pm}0.145{\mu}m$ and B-IM group was $0.289{\pm}0.142{\mu}m$. Ra became higher from B-1 group $(0.299{\pm}0.48{\mu}m$ to B-18 group $(0.642{\pm}0.313{\mu}m$. 2. Final cluster center of Ra was $0.361{\mu}m$ in cluster 1 $(B-IM\simB-7)$, $0.511{\mu}m$ in cluster 2 $(B-8\simB-14)$ and $0.624{\mu}m$ in cluster 3 ($(B-15\simB-18)$. There were significant difference among Ra of three clusters. 3 Ra of B-IM group was decreased 210.72% than Ra of F group. Ra of B-8 group and B-15 group was increased 35.49% and 51.35% respectively than Ra of B-IM group. 4. On FE-SEM, B-IM group showed the smoothest resin surface. B-8 group and B-15 group showed vertically shallow scratches , and wide and irregular vertical scratches on composite resin surface respectively. Within a limitation of this study, finished resin surface will be again smooth and glazy if BisCover would be reapplied within 8 to 14 months after applying to resin surface.

The Landscape Organization of the Dodong-SeoWon in the Aesthetics of Moderation (중용(中庸)의 미학으로 살핀 도동서원(道東書院)의 경관짜임)

  • Rho, Jae-Hyun;Shin, Byung-Chul
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.30 no.4
    • /
    • pp.44-55
    • /
    • 2012
  • This study is to interpret how landscape aesthetic characteristics of moderation, which is the point of human-oriented neo-confucianism vision, are projected to the landscape organization of a Dodong-SeoWon, known for its overflow to neo-confucianism grounds and standards among domestic SeoWon. The aspects of neo-confucianism discussion in the shape of Dodong-SeoWon with the beauty of from and contents dominating the landscape of Dodong-SeoWon different from constructive completeness as 7 external and internal landscape organization including placement, circulation, setting, vista, fencing, naming, and decoration are as follows. The left direction of Dodong-SeoWon, part of external organization, is the result of landscape organization that emphasized the stage of moderation through the unification of man and nature by naturalizing natural direction to human-oriented directions. Important aspects to rule external orders and standards of Dodong-SeoWon are principles of one classes based on ranks and bilateral symmetry that is the unity of setting and circulation landscape organization from penetrating the spirit of moderation with no bias. By securing territoriality by fencing the unity of verticality and horizontality, the landscape organization to reach moderation is expressed. Meanwhile, Suwoloo(水月樓) perceived on the floor of central assembly hall, the formation of time frame from roof piles of Hwanjumun(喚主門) as well as pilars of Jungjeongdang(中正堂), and rime link method inducing visual balance and openness through segment, combination, and others are vista organization that show the ideality of unique neo-confucianism building. Also as part of landscape organization contents. semantically, building name including arrangement from Taegukdoseol, ideological naming following the name of Ssanggye-SeoWon, which is the former body, the name of the hall symbolizing the transfer of neo-confucianism enlightenment, impartiality with no bias, as well as Geoinjae(居仁齋) and Geoijae(居義齋) based on olympic, are also results of applying neo-confucianism standards. Additionally. the SeoHoe(瑞花) expressing the change of IleumIlyang(一陰一陽) on the stylobate of Jungjeongdang, Saeho(細虎) which goes up and down, as well as Simul made of four dragons, are artistic expression of the moderation that symbolizes the harmony of ying and yang with no exceeding or insufficiency. Humorous and unique rocks and stones evenly arranged in all spots of Dodong-SeoWon are to promote anti-strict organization by offsetting the image and external order of the lecture hall as strict as it is, and this is very ironic as it is the other landscape organization in different dimension as well as the expression of moderation.

The information of the businesses and the protection of information human rights (기업정보화와 정보인권보호)

  • 하우영
    • Proceedings of the Korea Institutes of Information Security and Cryptology Conference
    • /
    • 2003.12a
    • /
    • pp.543-559
    • /
    • 2003
  • The information drive of the businesses requires new alternatives in that the promotion of business efficiency through information process technologies ends up conflicting with the protection of information human rights on laborers’side. Nevertheless, apathy on information protection has a tendency to be distorted by the efficiency of the businesses. Should the capital and mass media warn economic red lights, political circles with uneasiness would ignore the significance of information protection on the behalf of business efficiency. Therefore, the importance of information protection is considered a smaller interest than that of business efficiency with the infringements of human rights on laborers’side arising. Informatization of the businesses along with the developments of information process technologies has enabled the management to monitor and control the behaviors of laborers. This new problem needs to establish both information protection mechanism and institutional devices to regulate those labor controls. The security of business activity without human rights infringement warrants both basic rights of the public and spirit of the Constitution. The study suggests the establishment and revision of laws suitable to the period of information human rights. On top of that, the establishment of the basic law for information protection of individuals’with the common principle that integrates the related laws and rules on-off line is needed. This will warrant the active participation of labor unions and create specific alternatives for information protection.

  • PDF

Experimental Study with Respect to Dose Characteristic of Glass Dosimeter for Low-Energy by Using Internal Detector of Piranha 657 (Piranha 657의 Internal Detector를 이용한 저에너지에서 유리선량계의 선량 특성에 관한 연구)

  • Son, Jin-Hyun;Min, Jung-Whan;Kim, Hyun-Soo;Lyu, Kwang-Yeul;Lim, Hyun-Soo;Kim, Jung-Min;Jeong, Hoi-Woun
    • Journal of radiological science and technology
    • /
    • v.35 no.2
    • /
    • pp.119-124
    • /
    • 2012
  • Recently, Glass Dosimeter (GD) with thermoluminescent Dosimeter (TLD) are comprehensively used to measure absorbed dose from diagnostic field to therapy field that means from low energy field to high energy field. However, such studies about dose characteristics of GD, such as reproducibility and energy dependency, are mostly results in high energy field. Because characteristic study for measurement devices of radiation dose and radiation detector is performed using 137Cs and 60Co which emit high energy radiations. Thus, this study was evaluated the linearity according to Piranha dose which measured by changing tube voltage (50kV, 80kV and 100kV which are low energy radiations), reproducibility and reproducibility according to delay time using GD. Measurement of radiation dose is performed using internal detector of Piranha 657 which is multi-function QA device (RTI Electronic, Sweden). Condition of measurement was 25mA, 0.02sec, 2.5mAs, SSD of 100 cm and exposure area with $10{\times}10cm^2$. As above method, GD was exposed to radiation. Sixty GDs were divided into three groups (50kV, 80kV, 100kV), then measured. In this study, GD was indicated the linearity in low energy field as high energy existing reported results. The reproducibility and reproducibility according to delay time were acceptable. In this study, we could know that GD can be used to not only measure the high energy field but also low energy field.

Entrance Skin Dose According to Age and Body Size for Pediatric Chest Radiography (소아 흉부촬영 시 나이와 체격에 따른 입사피부선량)

  • Shin, Gwi-Soon;Min, Ki-Yeul;Kim, Doo-Han;Lee, Kwang-Jae;Park, Ji-Hwan;Lee, Gui-Won
    • Journal of radiological science and technology
    • /
    • v.33 no.4
    • /
    • pp.327-334
    • /
    • 2010
  • Exposure during childhood results in higher risk for certain detrimental cancers than exposure during adulthood. We measured entrance skin dose (ESD) under 7-year children undergoing chest imaging and compared the relationship between ESD and age, height, weight, chest thickness. Though it is important to measure chest thickness for setting up the exposure condition of chest examination, it is difficult to measure chest thickness of children. We set up exposure parameters according to age because chest thickness of children has correlation with age. In the exposure parameters, for chest A-P examination under 2 year-children, tube voltage (kVp) in hospital A was higher than that in hospital B while tube current (mAs) was higher in hospital B, thus the ESD values were about 1.7 times higher in hospital B. However, for chest P-A examination over 4 year-children, the tube voltage was 7 kVp higher in hospital B, the tube current were same in all two systems, and focus to image receptor distance (FID) in hospital B (180 cm) was longer than that in hospital A (130 cm), thus the ESD values were 1.4 times higher in hospital A. For same ages, the ESD values for chest A-P examinations were higher than those for chest P-A examinations. Comparing ESD according to age, ESD values were $154{\mu}Gy$, $194{\mu}Gy$ and $138{\mu}Gy$ for children under 1 year, 1 to under 4 years and 4 to under 7 years of age, respectively. These values were lower than reference level ($200{\mu}Gy$) recommended in JART (japan association of radiological technologists), however these were higher than reference values recommended by EC (european commission), NRPB (national radiological protection board) and NIFDS (national institute of food & drug safety evaluation). In conclusion, the values of ESD were affected by exposure parameters from radiographer's past experience more than x-ray system. ESD values for older children were not always higher than those for younger children. Therefore we need to establish our own DRLs (diagnostic reference levels) according to age of the children in order to optimize pediatric patient protection.