• Title/Summary/Keyword: 평가장치

Search Result 4,655, Processing Time 0.038 seconds

Evaluation of Mineral Content in Convenience Baby Food (간편 이유식의 무기질 함량 평가)

  • Cho, Young-Sun;Kim, Ki-Cheol;Shin, Sang-Woon;Sung, Jin-Hee;Kim, Ji-Eun;Baek, Eun-Jin;Lee, Eun-Bin;Kim, Hye-Jin;Park, Yong-Bae;Yun, Mi-Hye
    • Journal of Food Hygiene and Safety
    • /
    • v.35 no.5
    • /
    • pp.489-494
    • /
    • 2020
  • A total of 101 samples of convenience baby food products were analyzed by microwave digestion and mineral nutrients (iron, zinc, calcium, magnesium) were determined by inductively coupled plasma optical emission spectroscopy (ICP-OES). By type, the samples included 44 rice porridges, 40 soft-boiled rices, 11 purees, and 6 powders. The mean values for iron (Fe) content were 0.05 to 0.45 mg/100 g (excepted powder type, mg/l0 g). This was equivalent to 22.35% for rice porridge, 10.55% for soft-boiled rice, 9.88% for puree and 2.74% for powder type compared to the KDRIs (Dietary Reference Intakes for Koreans), respectively. The mean values for zinc (Zn) was 0.06 to 0.28 mg/100 g (excepted powder type, mg/l0 g) and the KDRI ratio was the lowest at 5.94% in puree, with 27.76%, 28.95% and 10.91% in rice porridge, soft-boiled rice and powder type, respectively. Calcium (Ca) content relative to KDRIs was relatively low compared to other minerals, with 6.65% for rice porridge, 3.61% for soft-boiled rice, 6.24% for puree and 3.07% for powder type, respectively. The magnesium (Mg) content of baby food ranged from 13.4% to 39.0% compared to KDRIs, and was included in all baby food as a whole. For balanced nutritional mineral supply to infants, it is recommended that information on mineral sources and ingredients in convenience baby food be clearly provided to ensure proper growth and development.

Evaluation of Compost Qualities with or without Microbial Inoculation for Food Waste Composting (미생물제 첨가유무에 따른 음식물 쓰레기 퇴비 부숙도 평가)

  • Jeong, Jun-Young;Jung, Kwang-Yong;Nam, Sung-Suk
    • Korean Journal of Environmental Agriculture
    • /
    • v.18 no.3
    • /
    • pp.280-286
    • /
    • 1999
  • This studies were conducted to evaluate efficiency of microbial inoculator for active composting of food wastes. The Microbial inoculators used in this studies were purchased from different comparise to evaluate their effectiveness for composting of food waste in Korea. The number of bacteria growing at $30^{\circ}C$ in commercial inoculator collected were below $91.0{\times}10^8\;CFU/g$ which were counted from well cured compost made by animal manure. The number of bacteria in commercial microbial inoculator, such as FL, VP, B9, CM and GE were higher than that of composted at $50^{\circ}C$ or $60^{\circ}C$ of incubation temperature. Fungi were counted in GR, VP and B9 as over $10^3CFU/g$ at $30^{\circ}C$ of incubation temperature, while fungi of all the commercial inoculator collected could not grown at $50^{\circ}C$ and $60^{\circ}C$. Actinomycetes in most of the these had higher number($10^5CFU/g$) than that of compost : however, it was not detected at $60^{\circ}C$ incubation temperature from all the samples collected. The amount of carbon dioxid production was order to VP>HU>B9>GE>CM>Control>Compost in the lab scale composting test with or without inoculation of commercial inoculators, however, but the difference in carbon dioxide production was similar among each treatments. The effect of inoculation on composting parmeter such as pH changes, temperature increasing and change of chemicals properties were a little among each treatments, with or without inoculation of commercial inoculator in active composting of food waste. Using commercial inoculator did not show any statistical difference in food waste composting process under various condition such as pH changes, temperature changes, etc.

  • PDF

Change in the Korean Fertility Control Policy and its Effect (출산력 억제정책의 영향과 변천에 관한 고찰)

  • Hong, Moon-Sik
    • Korea journal of population studies
    • /
    • v.21 no.2
    • /
    • pp.182-227
    • /
    • 1998
  • Korean government decided to adopt an explicit population control policy in 1961 and from the following year the establishment and operation of the national family planning programme was included in each of the Five-Year Economic Development Plans that began in 1962. This policy was pursued in the understanding that without proper population control measures korea could not be able to achieve economic development. Korean national family planning programme is characterized by contraceptive target system through public health network with distribution of free contraceptives by family planning field workers and clinical contraceptive services such as IUD, vasectomy and tubaligation at designated clinics by the government. In addition, IE&C activities by the Planned Parenthood Federation of Korea and programme evaluation and research by the Korea Institute for Health and Social Affairs contributed to the development of the government programme. Between 1960 and mid 1980s the nation's total fertility rate was reduced from 6.0 to population replacement level of 2.1 and thereafter it has been maintained at 1.6 to 1.7 of below replacement level. With a short period of less than three decades fertility transition was completed in Korea. It is estimated that if the current level of below replacement fertility continues, the population in Korea stabilize at around 52.78 million people by the year 2028, and it will begin to decrease thereafter. Under this circumstances, the government adopted new directions and strategies of the population policy in June 1996, focused primarily on population quality and social welfare than on demographic arenas. In spite of over 80 percent of high contraceptive prevalence among married women, high incidence of induced abortions is maintained. Moreover, the prevalence of sex selective induced abortions using procedures to determine the sex of the fetus has resulted in an imbalance in the sex ratio at birth. In order to overcome those problems associated with reproductive health new policy for population quality control and health promotion programme should be highly strengthened in the future.

  • PDF

Treatment Margin Assessment using Mega-Voltage Computed Tomography of a Tomotherapy Unit in the Radiotherapy of a Liver Tumor (간종양 방사선치료 시 토모테라피 메가볼트 CT를 이용한 치료 여백 평가)

  • You, Sei-Hwan;Seong, Jin-Sil;Lee, Ik-Jae;Koom, Woong-Sub;Jeon, Byeong-Chul
    • Radiation Oncology Journal
    • /
    • v.26 no.4
    • /
    • pp.280-288
    • /
    • 2008
  • Purpose: To identify the inter-fractional shift pattern and to assess an adequate treatment margin in the radiotherapy of a liver tumor using mega-voltage computed tomography (MVCT) of a tomotherapy unit. Materials and Methods: Twenty-six patients were treated for liver tumors by tomotherapy from April 2006 to August 2007. The MVCT images of each patient were analyzed from the $1^{st}$ to the $10^{th}$ fraction for the assessment of the daily liver shift by four groups based on Couinard's proposal. Daily setup errors were corrected by bony landmarks as a prerequisite. Subsequently, the anterior-, posterior-, right-, and left shifts of the liver edges were measured by maximum linear discrepancies between the kilo-voltage computed tomography (KVCT) image and MVCT image. All data were set in the 2-dimensional right angle coordinate system of the transverse section of each patient's body. Results: The liver boundary shift had different patterns for each group. In group II (segment 2, 3, and 4), the anterior mean shift was $2.80{\pm}1.73\;mm$ outwards, while the left mean shift was $2.23{\pm}1.37\;mm$ inwards. In group IV (segment 7 and 8), the anterior-, posterior-, right-, and left mean shifts were $0.15{\pm}3.93\;mm$ inwards, $3.15{\pm}6.58\;mm$ inwards, $0.60{\pm}3.58\;mm$ inwards, and $4.50{\pm}5.35\;mm$ inwards, respectively. The reduced volume in group II after MVCT reassessment might be a consequence of stomach toxicity. Conclusion: Inter-fractional liver shifts of each group based on Couinard's proposal were somewhat systematic despite certain variations observed in each patient. The geometrical deformation of the liver by respiratory movement can cause shrinkage in the left margins of liver. We recommend a more sophisticated approach in free-breathing mode when irradiating the left lobe of liver in order to avoid stomach toxicity.

The Comparative Assessment of the KVA and Dynamic Stereoacuity (동적시력(KVA)과 동적 입체시의 비교 평가)

  • Kim, Young-Cheong;Shim, Hyun-Suk;Kim, Sang-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.4
    • /
    • pp.519-525
    • /
    • 2014
  • Purpose: On this study, we investigated the relationship between the kinetic visual acuity (KVA) and the dynamic stereoacuity and the effects of anisometropia with measuring KVA and the dynamic stereoacuity. Methods: For 63 adults (male 30, female 33), KVA and the dynamic stereoacuity were measured by using the kinetic visual acuity tester (KOWA AS-4A) and the Howard-Dolman test (H-D test) at distance 2.5 m after conducted full correction of subjects' refractive error respectly. Results: The means of KVA were $0.49{\pm}0.25$ for total subjects, $0.58{\pm}0.26$ for male, $0.40{\pm}0.22$ for female, and LogMAD (Log minimum angle of displacement) dynamic stereoacuities were $1.27{\pm}0.44$($28.44{\pm}25.03sec$ of arc) for total subjects, $1.28{\pm}0.44$($28.23{\pm}23.34sec$ of arc) for male, $1.27{\pm}0.45$($28.63{\pm}26.83sec$ of arc) for female. KVA showed a statistically significant difference between male and female (p=0.00), but dynamic stereoacuity was no significant difference (p=0.97). No significant correlation was present between KVA and dynamic stereoacuity (r=0.03). Also there were no significant differences in the dynamic stereoacuity of the three group which were classified according to the low, middle, high range of KVA (p=0.99). The anisometropia were less than 1 D and over 1 D when divided into two groups, KVA and dynamic stereoacuity showed no significant difference between each (p=0.11, p=0.99). There was no significant correlation between anisometropia and KVA (r=0.33), dynamic stereoacuity (r=0.18) but the correlation between KVA and anisometropia revealed more higer than between dynamic stereoacuity and anisometropia. Conculsions: The KVA for adults showed a significant difference between male and female and male was higher than female for KVA. The dynamic stereoacuity due to the KVA, the KVA and dynamic stereoacuity due to anisometropia were not significant differences between each and also were not great correlations.

Performance Improvement of Dielectric Barrier Plasma Reactor for Advanced Oxidation Process (고급산화공정용 유전체 장벽 플라즈마 반응기의 성능 개선)

  • Kim, Dong-Seog;Park, Young-Seek
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.7
    • /
    • pp.459-466
    • /
    • 2012
  • In order to improved treatment performance of dielectric barrier discharge (DBD) plasma, plasm + UV process and gas-liquid mixing method has been investigated. This study investigated the degradation of N, N-Dimethyl-4-nitrosoaniline (RNO, indicator of the generation of OH radical). The basic DBD plasma reactor of this study consisted of a plasma reactor (consist of quartz dielectric tube, titanium discharge (inner) and ground (outer) electrode), air and power supply system. Improvement of plasma reactor was done by the combined basic plasma reactor with the UV process, adapt of gas-liquid mixer. The effect of UV power of plasma + UV process (0~10 W), gas-liquid mixing existence and type of mixer, air flow rate (1~6 L/min), range of diffuser pore size (16~$160{\mu}m$), water circulation rate (2.8~9.4 L/min) and UV power of improved plasma + UV process (0~10 W) were evaluated. The experimental results showed that RNO degradation of optimum plasma + UV process was 7.36% higher than that of the basic plasma reactor. It was observed that the RNO decomposition of gas-liquid mixing method was higher than that of the plasma + UV process. Performance for RNO degradation with gas-liquid mixing method lie in: gas-liquid mixing type > pump type > basic reactor. RNO degradation of improved reactor which is adapted gas-liquid mixer of diffuser type showed increase of 17.42% removal efficiency. The optimum air flow rate, range of diffuser pore size and water circulation rate for the RNO degradation at improved reactor system were 4 L/min, 40~$100{\mu}m$ and 6.9 L/min, respectively. Synergistic effect of gas-liquid mixing plasma + UV process was found to be insignificant.

Negligence theory of Aviation accident with reference to the japanese aviation accident precedent (항공 사고에서의 과실 이론 - 일본 항공 사고 판례를 중심으로 -)

  • Hwang, Ho-Won;Ham, Se-Hun
    • The Korean Journal of Air & Space Law and Policy
    • /
    • v.23 no.2
    • /
    • pp.115-136
    • /
    • 2008
  • The development of the aviation technology is beyond the people's imagination. For example, with some exaggeration, If the autopilot engage upon take off, You will realize that you are on the centerline of the foggy JFK runway 13R after 15 hours with only once or twice of intervention. But the more aviation technology develops, the more responsible the pilot will be who has the final authority of the aviation safety. In the JAL 706 accident caused by unidentified reason, the pilot increased pitch abruptly and overrode the control from the autopilot. The result of this process made the death of a flight attendant and some injuries of a few passengers. The district court found the pilot not guilty at the first trial on the ground that the control override was not connected to the possibility of foresight and avoidance of the human death. The pilot was proved to be innocent through the analysis of the DFDR and ADAS that the override did not precede the unidentified pitch up motion. The judicial precedent related to aviation accidents in Korea requires pilots' absolute and extended care compared to the ordinarily prudent or reasonably careful behaviors in the vehicle and medical accidents. Although there is some controversy about the standard care, the care required in the actual operation of high tech aircraft by a pilot should include objective and standard care and be judged by analysis of the scientific data. Although the pilot maintained the unusual hi speed that doesn't have safety margin and descended under turbulence in case of the JAL 706 accident, the court negatived its relation to the cause of pitch up. Also, the override of the control after initial pitch up might have caused the possibility of the death and injury, but the court denied it. Because of this complex cause of the aviation accidents, it is important for a court to figure out the core reason of the event and casual relationship with the pilot Now, It is required that the judgement of negligence in the aviation accidents should include an objective care with scientific data from simulated circumstances(or a simulator) as the Japanese court not from the theory of vehicle's negligence.

  • PDF

Comparison of Awareness of Symptoms and Illness Between Patients with Obstructive Sleep Apnea and Simple Snoring (수면무호흡증과 단순 코골이 환자의 증상과 질환 인식도 비교)

  • Lee, Seyoung;Kang, Jae Myeong;Cho, Yoon-Soo;Yoon, Hyun Jin;Kim, Ji-Eun;Shin, Seung-Heon;Park, Kee Hyung;Kim, Seon Tae;Kang, Seung-Gul
    • Sleep Medicine and Psychophysiology
    • /
    • v.23 no.1
    • /
    • pp.16-24
    • /
    • 2016
  • Background and Objectives: Obstructive sleep apnea (OSA) is often undiagnosed but is an important risk factor affecting the health of an individual. The level of awareness of the illness among patients with OSA is low and is not correlated with severity of the illness. This study was conducted to compare awareness of OSA symptoms and illness between patients with OSA and simple snorers. Materials and Methods: Two hundred eighty-two patients who were suspected of having OSA participated in this study. All subjects underwent overnight polysomnography. Those with an apnea-hypopnea index (AHI) ${\geq}5$ were classified as the OSA group, while those with an AHI < 5 were classified as the simple snoring group. A sleep questionnaire, which included items on awareness of the illness, OSA, and sleep symptoms, was administered to all subjects and their bed-partners. Results: Simple snorers were much more aware of their symptoms such as snoring, irregular breathing, and apnea than were patients with OSA. Bed-partners of simple snorers were also more aware of the participants' sleep symptoms than were partners of patients with OSA. However, the duration of OSA symptoms was longer in the OSA group. In the correlation analysis, the level of awareness of OSA symptoms was negatively correlated with AHI, age, body mass index, and Epworth Sleepiness Scale score. Among the sleep questionnaire and polysomnography results, only Pittsburgh Sleep Quality Index was positively correlated with level of awareness of OSA symptoms. The minority of the respondents had heard about the treatment methods of continuous positive airway pressure and oral appliance and preferred them as treatment options. Conclusion: This study suggests that simple snorers are more aware of their symptoms than are patients with OSA. A higher severity of OSA, represented by a higher AHI, is correlated with lower awareness of one's OSA symptoms.

The Differences of Anthropometric and Polysomnographic Characteristics Between the Positional and Non-positional Obstructive Sleep Apnea Syndrome (체위 의존성 및 체위 비의존성 폐쇄성 수면 무호흡증후군의 신체계측인자 및 수면구조의 차이)

  • Park, Hye-Jung;Shin, Kyeong-Cheol;Lee, Choong-Kee;Chung, Jin-Hong;Lee, Kwan-Ho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.48 no.6
    • /
    • pp.956-963
    • /
    • 2000
  • Backgrounds : Obstructive sleep apnea syndrome(OSA) can divided into two groups, positional(PP) and non-positional(NPP) obstructive sleep apnea syndrome, according to the body position while sleeping. In this study, we evaluated the differences of anthropometric data and polysomnographic recordings between the two types of sleep apnea syndrome. Materials : Fifty patients with OSA were divided two groups by Cartwright's criteria. The supine respiratory disturbance index (RDI) was at least two times higher than the lateral RDI in the PP group, and the supine RDI was less than twice the lateral RDI in the NPP group. This patients underwent standardized polysomnographic recordings. The anthropometric data and polysomnographic data were analyzed, statistically. Results : Of all 50 patients, 30% were found to be positional OSA. BMI was significantly higher in the PP group(p<0.05). Total sleep time was significantly longer in the PP group (350.6$\pm$28.2min, 333.3$\pm$46.0min, (p<0.05). Sleep efficiency was high in the PP group(89.6$\pm$6.4%, 85.6$\pm$9.9%, p<0.05). Deep sleep was significantly higher and light sleep was lower in the PP group than in the NPP group but no difference was observed in REM sleep between the two groups. Apnea index(AI) and RDI were significantly lower( 17.0$\pm$10.6, 28.5$\pm$13.3, p<0.05) and mean arterial oxygen saturation was higher in the PP group(92.7$\pm$1.8%. p<0.05) than in the NPP group. Conclusion : Body position during sleep has a profound effect on the frequency and severity of breathing abnormalities in OSA patients. A polysomnographic evaluation for suspected OSA patients must include monitoring of the body position. Breathing function in OSA patients can be improved by controlling their obesity and through postural therapy.

  • PDF

Effect of an Acrylic Plate and SSD on Dose Profile and Depth Dose Distribution of 9 MeV Electron Beams (에너지 저하체로서 아크릴과 SSD 가 9MeV 전자선의 측방 및 깊이선량분포에 미치는 효과)

  • 강위생
    • Progress in Medical Physics
    • /
    • v.9 no.2
    • /
    • pp.65-71
    • /
    • 1998
  • The aims are to evaluate the effects of an 1.0 cm acrylic plate and SSD on the dose profile and depth dose distribution of 9 MeV electron beam and to analyse adequacy for using an acrylic plate to reduce energy of electron beams. An acrylic plate of 1.0 cm thickness was used to reduce energy of 9 MeV electron beam to 7 MeV. The plate was put on an electron applicator at 65.4 cm distance from x-ray target. The size of the applicator was 10${\times}$l0cm at 100 cm SSD. For 100cm, l05cm and 110cm SSD, depth dose on beam axis and dose profiles at d$\_$max/ on two principal axes were measured using a 3D water phantom. From depth dose distributions, d$\_$max/, d$\_$85/, d$\_$50/ and R$\_$p/, surface dose, and mean energy and peak energy at surface were compared. From dose profiles flatness, penumbra width and actual field size were compared. For comparison, 9 MeV electron beams were measured. Surface dose of 7 MeV electron beams was changed from 85.5% to 82.2% increasing SSD from 100 cm to 110 cm, and except for dose buildup region, depth dose distributions were independent of SSD. Flatness of 7 MeV ranged from 4.7% to 10.4% increasing SSD, comparing 1.4% to 3.5% for 9 MeV. Penumbra width of 7 MeV ranged from 1.52 cm to 3.03 cm, comparing 1.14 cm to 1.63 cm for 9 MeV. Actual field size increased from 10.75 cm to 12.85 cm with SSD, comparing 10.32 cm to 11.46 cm for 9 MeV. Virtual SSD's of 7 and 9 MeV were respectively 49.8 cm and 88.5cm. In using energy reducer in electron therapy, depth dose distribution were independent of SSD except for buildup region as well as open field. In case of using energy reducer, increasing SSD made flatness to deteriorate more severely, penumbra width more wide, field size to increase more rapidly and virtual SSD more short comparing with original electron beam. In conclusion, it is desirable to use no energy reducer for electron beam, especially for long SSD.

  • PDF