• Title/Summary/Keyword: 편의 보정

Search Result 241, Processing Time 0.028 seconds

A study on the Factors Affected on the P- and S-wave Velocity Measurement of the Acrylic and Stainless Steel Core (아크릴 및 스테인리스강 시험편의 P-, S-파 속도 산출에 미친 영향 요인 고찰)

  • Lee, Sang-Kyu;Lee, Tae-Jong
    • Geophysics and Geophysical Exploration
    • /
    • v.14 no.4
    • /
    • pp.305-315
    • /
    • 2011
  • A total of 864 measurements for P- and S- wave velocity of acrylic and stainless steel core samples have been performed with respect to their lengths and axial load applied. S-wave velocity measurement was much harder than P-wave velocity, so that it showed higher deviation in measured S-wave velocity with respect to repeated measurement, length of the cores, and the axial load applied. Velocity measurements for acrylic cores showed more stable and less than half of the variation between the measurements than the stainless steel cores. This seems to be come from better coupling between the transducers and acrylic cores than stainless cores, and from larger value of the first arrival time in a similar system noise environments. From the analysis of the 864 measurements, it is recommended that the length of the core be 60 ~ 90 mm, axial load between 20 kg (27.7 $N/cm^2$) and 30 kg (41.6 $N/cm^2$) for measurement of wave velocity of the acrylic and stainless steel cores. Especially for measuring S-wave velocity of stainless steel core, core length should be less than 50 mm, otherwise it will be affected by mode conversion or others. These results can be used in measurement and correction for system delay in wave velocity measurement for rock cores.

Assessment of ECMWF's seasonal weather forecasting skill and Its applicability across South Korean catchments (ECMWF 계절 기상 전망 기술의 정확성 및 국내 유역단위 적용성 평가)

  • Lee, Yong Shin;Kang, Shin Uk
    • Journal of Korea Water Resources Association
    • /
    • v.56 no.9
    • /
    • pp.529-541
    • /
    • 2023
  • Due to the growing concern over forecasting extreme weather events such as droughts caused by climate change, there has been a rising interest in seasonal meteorological forecasts that offer ensemble predictions for the upcoming seven months. Nonetheless, limited research has been conducted in South Korea, particularly in assessing their effectiveness at the catchment-scale. In this study, we assessed the accuracy of ECMWF's seasonal forecasts (including precipitation, temperature, and evapotranspiration) for the period of 2011 to 2020. We focused on 12 multi-purpose reservoir catchments and compared the forecasts to climatology data. Continuous Ranked Probability Skill Score method is adopted to assess the forecast skill, and the linear scaling method was applied to evaluate its impact. The results showed that while the seasonal meteorological forecasts have similar skill to climatology for one month ahead, the skill decreased significantly as the forecast lead time increased. Compared to the climatology, better results were obtained in the Wet season than the Dry season. In particular, during the Wet seasons of the dry years (2015, 2017), the seasonal meteorological forecasts showed the highest skill for all lead times.

Accuracy Analysis of Orthometric Heights Based on GNSS Static Surveying (GNSS 정지측량을 통한 표고 산출 정확도 분석)

  • Shin, Gwang-Soo;Han, Joong-Hee;Kwon, Jay Hyoun
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.32 no.5
    • /
    • pp.527-537
    • /
    • 2014
  • In 2013, NGII(National Geographic Information Institute) has developed and provided the KNGeoid13(Korean National Geoid Model 2013) to support the fundamental computation of GNSS-derived orthometric height. In this study, the adjusted ellipsoidal height, the sum of geoidal height and height by the leveling, is applied to calculate the GNSS-derived orthometric height without the local bias, based on GNSS static surveying and KNGeoid13. The mean of errors in GNSS-derived orthometric heights could be verified with the leveling data, which was actually less than 0.5 cm with using the adjusted ellipsoidal heights, but 3 cm by calculating differences between ellipsoidal heights and geoidal heights. By analyze the accuracy of GNSS-derived orthometric height depending on the duration of observation, we could realized 95% of data shows less than 4 cm accuracy, when the GNSS survey conducting for 4 hours spread over two days, but while the case of GNSS survey conducting for 4 hours and 2 hours respectively, resulted in 95% of data less than 5cm level of accuracy. Also, if the ambiguity is fixed, less than 10cm of accuracy could be obtained at 95% of data for only 30 minutes GNSS survey over a day. Following the study, we expected that the height determination by GNSS and geoid models can be used in the public benchmark surveying.

DEM Generation by the Matching Line Using Exterior Orientation Parameters of the IKONOS Geo Imagery (IKONOS 위성영상의 외부표정요소로부터 정합선 수립에 의한 DEM 생성)

  • Lee, Hyo-Seong;Ahn, Ki-Weon
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.24 no.4
    • /
    • pp.367-376
    • /
    • 2006
  • This study determines the optimum polynomial of exterior orientation parameters(EOPs) as a function of line number of linear array scanner. To estimate priori EOPs, meta data of IKONOS scene and ground control points are used. We select a first order polynomial and a constant for position elements modeling and rotation elements modeling. Positioning accuracy of the determined EOPs is compared with that of RPCs bias-corrected by the least squares adjustment. There is almost no difference between accuracies of the two methods. To obtain digital elevation model(DEM), matching line is established by the EOPs. The DEM is compared with DEM generated by ERDAS IMAGINE software, which utilizes the bias-corrected RPCs. Height differences of DEMs by the two methods are ranged within a allowable standard deviation. The produced DEM, therefore, shows accuracy similar to the verified method.

Application of Parameter-setting Free Method for Multi-objective Optimal Design of Water Distribution Systems (상수관망 다목적 최적설계를 위한 매개변수 자동보정 기법의 적용)

  • Choi, Young Hwan;Lee, Ho Min;Yoo, Do Guen;Choi, Ji Ho;Kim, Joong Hoon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.209-209
    • /
    • 2015
  • 상수도 관망은 대표적인 사회기반시설로 수원으로부터 수용가에 이르기까지 안정적으로 유량을 공급하는 것을 목표로 한다. 상수도 관망의 최적설계는 요구되는 절점의 수압, 관로의 유속 등 수리학적 제약조건을 만족시키는 범위 안에서 비용을 최소화하는 설계안을 얻어내는 것을 목표로 시작하였다. 하지만 비용만을 고려한 과거의 상수도 관망 최적설계는 미래의 불확실한 조건에 매우 취약하고, 사용자의 다양한 요구를 충족시키지 못한다. 이 때문에 현대의 상수도 관망의 설계시 다양한 설계인자의 고려와 함께 효율적인 최적설계기법 적용의 필요성이 대두되고 있다. 따라서 본 연구에서는 상수도 관망 최적설계에 다양한 설계인자를 동시에 고려하기 위해 다목적 최적 설계기법인 Multi-objective Harmony Search 알고리즘을 적용하였다. 또한 다목적 최적설계의 효율성 증대를 위하여 매개변수 자동보정 기법 중 하나인 Parameter-Setting-Free (PSF) 기법(Geem and Sim, 2010)을 사용하였다. PSF 기법은 최적화 알고리즘의 매개변수 설정의 번거로움을 없애고, 반복수행을 통한 해 탐색이 진행됨에 따라 가장 효율적으로 작용하는 매개변수를 자동으로 설정하여 탐색효율을 강화하도록 고안된 기법이다. 본 연구에서는 제안된 기법을 실제 상수도관망의 최적설계에 적용하였고 그 결과를 분석하였다. 그 결과 제안된 기법을 통해 관망의 비용을 포함한 다양한 설계인자를 동시에 만족시키는 최적설계안을 효과적으로 도출 할 수 있었으며, 매개변수 자동보정 기법의 적용을 통해 해 탐색의 효율성과 편의성을 향상시킬 수 있었다.

  • PDF

Impacts of Parameter Changes According to Landuse Changes on Hydrologic Simulation (토지이용 변화에 따른 매개변수 변화가 수문모형의 수문 해석에 미치는 영향 분석)

  • Hwang, Soonho;Kim, Gye Woong;Kang, Moon Seong
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2018.05a
    • /
    • pp.336-336
    • /
    • 2018
  • 수문 모형에서 토지이용 자료는 수문해석에서 중요한 환경변수라고 할 수 있으며, 토지이용 자료의 정확도 및 해상도에 따라서도 수문해석 결과가 달라지기도 한다. 특히, SWAT 모형은 수문해석을 위한 알고리즘에서 고려하는 토지이용 관련 매개변수가 다양하며, 수문 모형의 적용성을 평가하는데 토지이용 관련 매개변수를 정확하게 추정하는 것이 중요한 요인이라 할 수 있다. 일반적으로 수문 모형의 검보정을 위해서는 각 년도에 맞는 토지이용자료를 이용하여야 하고, 각 년도별 매개변수를 달리하여 검보정을 실시하여야 하지만 토지이용 자료의 부족함과 수문모형 검보정의 편의성을 위해 특정년도의 토지이용 자료를 이용하여 고정된 매개변수를 이용하고 있다. 특히, 장래 수문변화를 고려하는 연구에서는 장래 토지이용 변화를 고려하여, 토지이용 변화에 따라 변화하는 매개변수를 고려하고 있으나 장래 수문해석에 있어 모든 매개변수를 토지이용 자료로만 추정할 수 없기 때문에 기 검보정에 사용한 매개변수를 일부 수용하여 적용하고 있는 실정이다. 그러므로 본 연구에서는 모형의 검보정에 있어 고정된 매개변수를 사용한 경우 (a)와 토지이용 변화에 따라 변화하는 토지이용 특성과 매개변수 간의 상호 관계를 이용한 경우 (b)를 비교하여 토지이용 변화에 따른 매개변수 변화를 고려한 경우의 수문 모형의 수문모형 해석 결과를 검토하였다. 본 연구에서는 연도별 토지이용 자료를 생산하기 위해서 무료로 공개하는 위성영상 중 자료의 공간해상도와 분광해상도가 상대적으로 좋은 Landsat 위성영상 자료와 Sentinel 위성영상을 고려하였다. 또한 연구대상지는 토지이용 변화를 뚜렷이 확인할 수 있고 유역 말단 부분에 수문 모니터링 (혹은 유량 자료가 구축된 곳)이 이루어지고 있는 지역으로 선정하였다.

  • PDF

Surgical Results for Treating Postpneumonectomy Empyema with BPF by Using an Omental Pedicled Flap and Thoracoplasty (전폐절제술 후 기관지 흉막루를 동반한 농흉에서 유경성 대망 이식편과 흉곽성형술을 이용한 수술적 치료에 대한 임상 고찰)

  • Jeong, Seong-Cheol;Kim, Mi-Jung;Song, Chang-Min;Kim, Woo-Shik;Shin, Yong-Chul;Kim, Byung-Yul
    • Journal of Chest Surgery
    • /
    • v.40 no.6 s.275
    • /
    • pp.420-427
    • /
    • 2007
  • Background: Postpneumonectomy empyema (PPE) due to bronchopleural fistula (BPF) can be a surgical challenge for surgeons. We analyzed the follow-up outcomes after performing omentopexy and thoracoplasty for the treatment of PPE with BPF after pneumonectomy. Material and Mehod: Between December 1991 and January 2006, 9 patients underwent BPF closure using an omental pedicled flap for the treatment of PPE with BPF after pneumonectomy. There were 7 males and 2 females (mean age: $45.9{\pm}9$ years). The patients were followed up for a mean of 58 months (median: 28 months, range: $6{\sim}169$). When we performed omentopexy, the surgical procedures for empyema were thoracoplasy for 8 patients and the Clagett procedure for 1 patient. Thoracoplasty was performed for the latter patient due to recurrence of empyema, Result: For the 8 patients who were treated by omentopexy and thoracoplasty, there was 1 operation-related death due to sepsis. During follow up, 1 patient, who was treated by omentopexy and a Clagett procedure, died of acute hepatitis 40 months postoperatively. The early mortality was 11.1% (8/9). Of the 8 patients, including the 1 late death patient, successful closure of the BPF were achieved in all patients (8/9) and the empyema was cured in 7 patients (7/8). Conclusion: The BPF closure using an omental pedicled flap was an effective method for treating PPE with BPF due to 75-destroyed lung, and thoracoplasty with simultaneous omentopexy was effective and safe for removing dead space if the patient was young and in a good general condition.

A Comparative Study of Blood Lead Measurement by Polarized Zeman Effect Correction AAS and D2 Correction AAS Method (편광 Zeeman 보정 및 D2 보정 방법에 의한 혈중연 측정치의 비교 연구)

  • Lee, Seok Ki;Ahn, Kyu Dong;Lee, Byung Kook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.5 no.1
    • /
    • pp.59-67
    • /
    • 1995
  • Blood lead assay by $D_2$ lamp background correction method of atomic absorption spectrophotometer(AAS) with wavelength of 283.3 nm is most popular in occupational health practice in Korea. On the other hand, $D_2$ lamp background correction method with wavelength of 217.0 nm is also often used in general chemical analysis for lead assay in general purpose. But both methods have some weakness of background correction which brought direct effect on the results of analysis. Recently blood lead assay with polarized Zeeman effect of AAS was introduced and is now preferred in many laboratory than $D_2$ correction method in blood lead analysis. But still AAS with $D_2$ lamp are widely used in the field of occupational health in Korea. This study compared blood lead assay data with $D_2$ correction methods(283.3 and 217.0 nm) and with that of polarized Zeeman effect correction method to evaluate the validity of 02 correction methods. The results obtained were as follows; 1. Taking the value of polarized Zeeman effect method as reference value of 1.00, the mean relative value of $D_2$ correction method with wavelength of 217.0 nm was 0.92 and that with wavelength of 283.3 nm was 0.90 respectively in the analysis of blood lead whose value were below $20.0{\mu}g/dl$(p<0.001). Both mean values were statistically smaller than polarized Zeeman effect correction method. But in the analysis of blood whose value were between 20.0 to $20.0{\mu}g/dl$, the mean relative value of $D_2$ correction method was 0.96 in both wavelength and did not differ from polarized Zeeman effect method(p<0.001). There was no difference of blood lead between $D_2$ correction method and polarized Zeeman effect method in the analysis of blood lead whose value were over $40.0{\mu}g/dl$. 2. The variations of background correction value in polarized Zeeman effect method were not changed by increase of blood lead, but those in $D_2$ correction methods were increased by the increase of blood lead. While then relative standard deviation(RSD) of data measured by Zeeman effect method were decreased by the increase of blood lead, those by $D_2$ methods were nol differed by the increase of blood lead.

  • PDF

Statistical Issues in the Articles Published in the Journal of Veterinary Clinics (한국임상수의학회지에 발표된 논문의 통계분석 검토)

  • Pak, Son-Il;Oh, Tae-Ho
    • Journal of Veterinary Clinics
    • /
    • v.27 no.2
    • /
    • pp.170-174
    • /
    • 2010
  • With the ease availability of statistical software and powerful computers the application of statistical methods in domestic veterinary journals is on the increase. In parallel with this benefit, statistical errors are not uncommon even in renowned scientific and medical journals. These errors may lead to misinterpretation of the data, thereby, subjected to faulty conclusions. A systematic review of articles published in 8 issues of the Journal of Veterinary Clinics during 2006-2007 was performed to assess the statistical methodology and reporting. Ninety-four (72.9%) articles of the 129 original articles screened included any inferential statistical analysis in the article, including comparison of 3 or more groups (53 or 56.4%), comparison of independent 2 groups (40 or 42.6%), and paired t-test (9 or 9.6%) in order. Of the 94 articles in which statistical analysis was done 62 (or 66.0%) had at least 1 statistical error. Errors included failure to apply or incorrectly applying independent Student's t-test for paired data or vice versa, inappropriate use of t-test for more than 3 groups and failure in chi-square test to consider continuity-correction for small expected frequencies. The common errors in ANOVA were failure to validate assumption of the test, inappropriate post-hoc multiple-comparison and incorrect assumption of independence of data in repeated measures design. Reporting errors included failure to state statistical methods and failure to state specific test if more than 1 test was done. It is suggested that an editorial effort would be necessary to achieve the improvement of appropriate statistical procedures through the publication of statistical guidelines to author(s).

Estimation of Surface Reflectance by Utilizing Single Visible Reflectance from COMS Meteorological Imager - Analysis of BAOD correction effect - (천리안위성 기상 탑재체의 가시 채널 관측을 이용한 지표면 반사도 산출 - 배경광학두께 보정의 효과 분석 -)

  • Kim, Mijin;Kim, Jhoon;Yoon, Jongmin
    • Korean Journal of Remote Sensing
    • /
    • v.30 no.5
    • /
    • pp.627-639
    • /
    • 2014
  • Accurate correction of surface effect from back scattered solar radiance is one of key issue to retrieve aerosol information from satellite measurements. In this study, two different methods are applied to retrieve surface reflectance by using single visible channel measurement from meteorological imager onboard COMS. The first one is minimum reflectance method, which composes the minimum value among previously measured reflectances at each pixel over a certain search window length. This method assumes that the darkest pixel corresponds to the aerosol-free condition, and deduces surface reflectance by correcting atmospheric scattering from the measured visible reflectance. The second method, named as the "atmospheric correction method" in this study, estimates the result by correcting aerosol and atmospheric scattering with ground-based observation of aerosol optical properties. The purpose of this study is to investigate the retrieval accuracy of the widelyused minimum reflectance method. Also, the retrieval error caused by the loading of background aerosol is mainly estimated. The comparison between surface reflectances retrieved from the two methods shows good agreement with the correlation coefficient of 0.87. However, the results from the minimum reflectance method are slightly overestimated than the values from the atmospheric correction method when surface reflectance is lower than 0.2. The average difference between the two results is 0.012 without the background aerosol correction. By considering the background aerosol effect, however, the difference is reduced to 0.010.