• Title/Summary/Keyword: 펌프 특성

Search Result 1,224, Processing Time 0.026 seconds

Design Optimization of Dual-Shell and Tube Heat Exchanger for Exhaust Waste Heat Recovery of Gas Heat Pump (GHP 배열회수용 이중 쉘-튜브형 배기가스 열교환기의 설계 최적화)

  • Lee, Jin Woo;Shin, Kwang Ho;Choi, Song;Chung, Baik Young;Kim, Byung Soon
    • Transactions of the KSME C: Technology and Education
    • /
    • v.3 no.1
    • /
    • pp.23-28
    • /
    • 2015
  • In this paper, we performed the design optimization dual-shell and tube heat exchanger on exhaust waste heat recovery for gas heat pump using CFD and RSM. CFD analysis is useful to design the complex structure such as double shell and tube heat exchanger. By computer simulation, engineers can assess the feasibility of the given design factors and change them to get a better design. But if one wishes to perform complex analysis on the simulation, such dual-shell and tube heat exchanger for GHP, the computational time can become overwhelming. CFD is powerful but it takes a lot of time for complex structure. Therefore, the CFD analysis is minimized by the optimization using the RSM method. As a result, the number of baffle and tube are optimized by 6 baffles and 25 tubes for heat transfer and flow friction. And then pressure drop and heat transfer is improved about 12.2%. We confirm the design optimization using CFD and RSM is useful on complex structure of heat exchanger.

Environmental Isotope-Aided Studies on River Water and Ground Water Interaction in the Region of Seoul Part I: Isotope Hydrology of the Shallow Alluvial Aquifer Han R. Valley (동위원소를 이용한 서울 지역의 강수와 지하수와의 상호연관성에 관한 연구 제 1 보 : 동위원소를 이용한 한강류역 충적대수층 지하수의 수문학적 연구)

  • Jong Sung Ahn;Jae Sung Kim;You Sun Kim;Peter Airey;Bryan Payne
    • Nuclear Engineering and Technology
    • /
    • v.13 no.2
    • /
    • pp.85-96
    • /
    • 1981
  • A preliminary study of the isotope hydrology of the Han River Valley is presented. This investigation is part of a project whose overall aim is to relate the levels of heavy metal ions to the dynamics of the groundwater movement in order to establish (i) whether there is any evidence for the deterioration in groundwater quality associated with the release of industrial effluents and (ii) if so, to determine the migration path-ways. Evidence is adduced that the recharge mechanism is principally determined by the degree of urbanisation. In the metropolitan area of Seoul, river recharge dominates probably due to the combined effects of reduced infiltration and increased pumpage. In the inter-urban region, the major source of recharge is local precipitation. During the spring sampling period when the river levels were low. evidence was obtained for appreciable groundwater infiltration in the vicinity of the upstream transect. No significant correlations were observed between the levels of heavy metals in the groundwater, and the recharge mechanism, the distance from the river or the electrical conductivity of the samples.

  • PDF

Design and Construction of a Bottoming Organic Rankine Cycle System for an Natural Gas Engine (가스엔진용 유기랭킨사이클의 설계 및 제작)

  • Lee, Minseog;Baek, Seungdong;Sung, Taehong;Kim, Hyun Dong;Chae, Jung Min;Cho, Young Ah;Kim, Hyoungtae;Kim, Kyung Chun
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.6
    • /
    • pp.65-72
    • /
    • 2016
  • ORC system was designed and constructed for utilizing the heat of the exhaust gas and coolant released from the gas engine which was modified to use natural gas as a fuel. In this paper the components of the ORC system were designed and manufactured based on measured data of the gas engine. The components are composed of two plate heat exchanger, the 5kW-class expander and multi stage centrifugal pump. The thermodynamic performance of the ORC system was analyzed by using the electric heater. Also, the developed ORC system was implemented to modified natural gas engine. Two gas engines were used to supply heat to the ORC system. As a result of test bench, when the heat source temperature is $110^{\circ}C$ expander shaft power, the pressure ratio and cycle efficiency is 5.22kW, 7.41, 9.09%. As a result of field test, when the heat source temperature is $86^{\circ}C$ expander shaft power, the pressure ratio and cycle efficiency is 2kW, 3.75, 6.45%.

Fog Nozzle-Greenhouse Cooling System Analysis (포그노즐을 이용한 온실냉방시스템 분석)

  • 김영중;유영선;윤진하;오권영;김승희
    • Journal of Bio-Environment Control
    • /
    • v.6 no.1
    • /
    • pp.48-54
    • /
    • 1997
  • Among the various vegetables eggplant and gourd family can stand against high temperature environmental condition, about 35$^{\circ}C$. However, most of greenhouse farmers are giving up crop cultivation during hot summer season due to extreme temperature, 4$0^{\circ}C$ or above, condition of greenhouse interior. To improve this inferior crop growth condition, for nozzle system was installed in the pet greenhouse and the effect of fog system was investigated in order to determine fog water amount and the required fog nozzle numbers according to house volumes. MEE fog nozzle was selected for this Investigation which can produce water particle size of 27${\mu}{\textrm}{m}$ with water amount of 100$m\ell$ at pumping pressure of 70kg/$\textrm{cm}^2$. House cooling test was conducted in the pet greenhouse with one minute fogging and one minute air ventilation without stopping. It maintained 32$^{\circ}C$ at the house interior when the atmosphere and the house temperature were 35 and 4$0^{\circ}C$, respectively. And, an experimental equation was developed through calculating the changes of relative humidity and temperature with psychrometric equation which revealed the moisture transfer pattern between the house air and fog system. It showed that the required water fogging amounts to reduce 1$0^{\circ}C$, 40 to 3$0^{\circ}C$, needs 80.7$\ell$ for 1-2W(8,350㎥) and 99.9$\ell$ for 3-2G-3S(10,330㎥) type greenhouse with particle size of 27${\mu}{\textrm}{m}$.

  • PDF

Proposal of Design Criteria on Multi-functional Tunnel for the Urban Traffic Tunnel to Flooding Bypass (도심지 홍수저감과 교통량 분담을 위한 다기능 대심도 터널 설계 기준 방안 제시)

  • Kwon, Soonho;Kim, Junghwan;Chung, Gunhui
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.5
    • /
    • pp.3518-3524
    • /
    • 2015
  • Spatial and time variation of the precipitation in Korea is high, therefore, more than 2/3 of the annual precipitation is concentrated during the rainy season. Climate change also causes the intensive rainfall in the area of dense population, thus the occurrence frequency of the heavy flood in the impervious area has been increased. Therefore, the structural food mitigation measures such as the construction of the higher design frequency stormwater pipes, pumping stations, and/or detention ponds. The flood bypass tunnel or retention storage is also one of the efficient structures to mitigate flood damage in the urban area. However, the economic feasibility has been controversial because the flood bypass tunnel might be used once or twice a year. To solve the problem, the multi-functional tunnel for the urban traffic and flooding bypass has been considered. In this study, the design criteria of the road and water tunnel has been analysed and the composite design criteria is proposed for the multi-functional tunnel which is expected to be constructed.

Evaporation Heat Transfer Characteristics of Carbon Dioxide in a Diameter Tube of 4.57mm (내경 4.57mm 관내 CO2의 증발 열전달 특성)

  • Son, Chang-Hyo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.3
    • /
    • pp.574-579
    • /
    • 2008
  • The evaporation heat transfer coefficient of $CO_2$ (R-744) in a horizontal tube was investigated experimentally. The main components of the refrigerant loop are a receiver, a variable-speed pump, a mass flow meter, a pre-heater and evaporator (test section). The test section consists of a smooth, horizontal stainless steel tube of inner diameter of 4.57mm. The experiments were conducted at mass flux of 400 to $900kg/m^2s$, saturation temperature of 5 to $20^{\circ}C$, and heat flux of 10 to $40kW/m^2$. The test results showed the heat transfer of $CO_2$ has a greater effect on nucleate boiling more than convective boiling. Mass flux of $CO_2$ does not affect nucleate boiling too much. In comparison with test results and existing correlations, All of the existing correlations for the heat transfer coefficient underestimated the experimental data. However Jung et al.'s correlation showed a good agreement with the experimental data. Therefore, it is necessary to develope accurate predictions determining the evaporation heat transfer coefficient of $CO_2$ in horizontal tubes.

Analysis of Loss of Offsite Power Transient Using RELAP5/MODl/NSC; I: KNU1 Plant Transient Simulation (RELA5/MOD1/NSC를 이용한 원자력 1호기 외부전원상실사고해석 - I. 실제사고해석)

  • Kim, Hho-Jung;Chung, Bub-Dong;Lee, Young-Jin;Kim, Jin-Soo
    • Nuclear Engineering and Technology
    • /
    • v.18 no.2
    • /
    • pp.97-106
    • /
    • 1986
  • System thermal-hydraulic parameters and simulated, using the best-estimate system code(RELAPS/MODl/NSC), based upon the sequence of events for the KNU1 (Korea Nuclear Unit 1) loss of offsite power transient at 77.5% power which occurred on June 9,1981. The results are compared with the actual plant transient data and show good agreements. After the flow coastdown following the trips of both reactor coolant pumps, the establishment of natural circulation by the temperature difference between the hot and the cold legs is confirmed. The calculated reactor coolant flowrate closely approximates the plant data indicating the validity of relevant thermal-hydraulic models in the RELAP5/MOD1/NSC. Results also show that the sufficient heat removal capability is secured by the appropriate supply of the auxiliary feedwater without the operation of S/G PORVs. In addition, a scenario accident at full power, based upon the same sequence of events described above, is also analysed and the results confirmed that the safety of KNU1 is secured by the appropriate operation of the S/G PORVs coupled with the supply of auxiliary feedwater which ensures sufficient heat removal capability. The characteristics of the non-safety related components such as the turbine stop valve closing time, S/G PORV settings etc. are recognized to be important in the transient analyses on a bestestimate basis.

  • PDF

The Effect of Low Impact Development Techniques on Urban Runoff (저영향개발기법이 도시 유출에 미치는 영향)

  • Kim, Heesoo;Chung, Gunhui
    • Journal of Wetlands Research
    • /
    • v.23 no.4
    • /
    • pp.307-316
    • /
    • 2021
  • Due to rapidly increased urbanization, impervious area has been extended and concerns about urban flooding has been increased as well. A lot of effort has been made to restore the urban water circulation. Low Impact Development (LID) technology that consist of retention, infiltration, and evapotranspiration has begun to attract attention to simulate the hydrologic phenomenon before and after development. Many researches on the technique is being actively conducted. In this study, the effect on reducing runoff in urban catchment was analyzed and evaluated by applying LID techniques using SWMM and six scenarios. A SWMM-LID model was built for the Gasan 1 rainwater pumping station basin, and Green Roof and Permeable Pavement were selected as LID techniques to be applied. As a result, the reduction effect of the permeable pavement was larger than green roof. In the future, the results could be used to design a LID facility using the characteristics of the watershed, and other urban water resource factors such as river and groundwater levels that affect each other should be considered, so that the entire system can be considered.

High-power Yb Fiber Laser with 3.0-kW Output (3.0 kW 고출력 발진 단일 모드 Yb 광섬유 레이저)

  • Park, Jong Seon;Park, Eun Ji;Oh, Ye Jin;Jeong, Hoon;Kim, Ji Won;Jung, Yeji;Lee, Kangin;Lee, Yongsoo;Cho, Joonyong
    • Korean Journal of Optics and Photonics
    • /
    • v.32 no.4
    • /
    • pp.147-152
    • /
    • 2021
  • We report high-power continuous-wave operation of a Yb-doped fiber laser at 1070 nm, pumped by high-power laser diodes at 976 nm. Based on theoretical calculation of the stimulated Raman scattering and temperature distribution in the fiber, we construct a bidirectionally pumped Yb-fiberlaser system incorporating a pair of fiber Bragg gratings and a cladding light stripper. The fiber laser yields 3.0 kW of continuous-wave output at 1070 nm in a diffraction-limited beam with M2 ≈ 1.26 for 4.1 kW of incident pump power, corresponding to a slope efficiency of 81.5%. The prospects for further power scaling are discussed.

Analytic study on thermal management operating conditions of balance of 100kW fuel cell power plant for a fuel cell electric vehicle (100kW급 연료전지 열관리 시스템 실도로 운전조건 해석적 연구)

  • Lee, Ho-Seong;Lee, Moo-Yeon;Cho, Choong-Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.2
    • /
    • pp.1-6
    • /
    • 2019
  • The objective of this study was to investigate performance characteristics of thermal management system(TMS) in a fuel cell electric vehicle with 100kW Fuel Cell(FC) system. In order to build up analytic modelling for TMS, each component was installed and tested under various operating conditions, such as water pump, radiator, 3-Way valve, COD heater, and FC stack etc. and as the results of them, correlations reflecting component's characteristics with flow rate, air velocity were developed. Developed analytic modelling was carried out under various operating conditions on the road. To verify modelling's accuracy, after prediction for optimum coolant flow rate was fulfilled under certain operating conditions, such as FC system, water pump speed, opening of 3-way valve, and pipe resistance, analytic and experimental values were compared and good agreement was shown. In order to predict cold-start operating performance for analytic modelling, coolant temperature variation was analyzed with $-20^{\circ}C$ ambient temperature and duration was predicted to rise in optimum temperature for FC. Because there is appropriate temperature difference between inlet and outlet of FC stack to operate FC system properly, related analysis was performed with respect to power consumption for TMS and heat rejection rate and performance map was depicted along with FC operating conditions.