A Study on Partial Load Performance of Absorption Type Heat Pump for Waste Heat Recovery of Closed Cooling Water (기기냉각수 폐열회수용 흡수식 히트펌프의 부분부하 성능에 관한 연구)

  • Park, Byungchul;Kim, Taehyeong;Kim, Kwangsu
    • Journal of Energy Engineering
    • /
    • v.28 no.2
    • /
    • pp.47-54
    • /
    • 2019
  • As absorption type heat pump for waste heat recovery is installed in combined cycle power plant for Energy Service Company, performance test is implemented to confirm the operation data on partial load. The operation data changes according to the heat pump operation on partial load are as follows. Total heat output increases, because waste heat of closed cooling water and a portion of LP steam from HRSG is supplied. But electric power output of steam turbine is reduced, because LP steam to steam turbine is reduced. And heat output from HP district heater and LP district heater is reduced, because HP turbine exhaust steam to HP district heater and LP district heater is reduced. On partial load operation, turbine output reduction is higher than the base load operation. Therefore, on partial load, heat pump should be operated in consideration of the heat output increase and electric power output reduction.

揚水 發電所의 心要性과 高宵差 大量容 펌프.水車의 動向

  • 이용식
    • Journal of the KSME
    • /
    • v.20 no.3
    • /
    • pp.201-203
    • /
    • 1980
  • 최근 전력수요의 증대와 석유위기에 따라 화력발전소의 연료 cost의 상승때문에 선진국에서는 대용량의 원자력 발전소의 건설이 증대되고 있으며, 원자력발전의 빈하조절의 난점 때문에 잉 여발력의 발생이 예상되는바 이들 잉여전력의 소화와 발전소의 효율향상, 철두전력의 공급상 변화변동에 대한 속응성이 가장 우수한 앙수발전소의 고려는 불가피 하게 된다. 양수발전은 전 력의 소비가 가장적은 심야에 잉여전력을 동력으로 이용하여 pump로 하부저수지에 저장되어 있는 물을 비교적 높은 곳에 자리잡은 상부 저수지에 양수한 다음 양간 또는 야간의 접두번하 시(peak time)나 계통사고때 이물을 다시 하부 저수지에 방유하면서 발전하는 점두변히 담당 발전방식이다. 따라서 양수발전은 peak 전력공급 뿐 아니라 심야의 값싼 전력을 소화 시키기 때문에 대용량 기저발전소(화력및 원자력)의 이용율을 향상 시켜주는 두가지 구실을 하게 된다.

  • PDF

A Real-Time Monitoring System for the Portable Insulin Pumps Using ZigBee (ZigBee 모듈을 이용한 휴대용 인슐린 펌프의 실시간 모니터링 시스템)

  • Lee, Soo-Yong;Kim, Ji-Hong;Kim, Yong-Hyun;Im, Hwa-Suk;Oh, Myung-Keun;Hong, Yun-Sik
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2007.06d
    • /
    • pp.157-162
    • /
    • 2007
  • 최근 홈 네트워크 및 유비쿼터스 컴퓨팅에 대한 일반인들의 관심이 크게 증가하면서, 10m 내외의 단거리에서 사용되는 개인 무선 네트워킹 솔루션인 무선 PAN 기술이 주목받고 있다. 본 논문에서는 이러한 무선 PAN 기술 중 저속, 저가, 저전력의 무선통신 기술인 ZigBee 이용해 당뇨병 환자들을 위한 실시간 모니터링 시스템을 구현하였다. 즉, 휴대용 인슐린 펌프에 ZigBee 통신이 가능한 모듈을 장착함으로써, 인슐린 펌프에 내장된 환자의 혈당치, 인슐린 투입량 등과 같은 중요 데이터를 별도의 조작 없이 유선 클라이언트에 실시간 전송할 수 있게 된 것이다. 한편, 유선 클라이언트에 저장된 환자의 정보는 서버에 즉시 전송되며, 담당 주치의의 모니터링이 가능하도록 웹 접근성을 부여하였다. 이를 통해 환자들이 보다 안전하고 편리하게 휴대용 인슐린 펌프를 사용할 수 있도록 하였다.

  • PDF

Real-Time Pump Scheduling Technique for Optimal Operation of Water Distribution System (관망운영 최적화를 위한 실시간 펌프스케줄링 기법 개발)

  • Woo, Hyoung Min;Kim, Ju Hwan;Ahn, Hyo Won;Yoon, Jae Heung
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2004.05b
    • /
    • pp.1316-1320
    • /
    • 2004
  • 생활수준의 향상과 기술발전에 따라 상수도 관망시스템에 관할 관점 또한 기존의 설계 및 해석의 개념에서 안정적이고 효율적인 용수공급 운영의 측면으로 변화하고 있다. 본 연구에 서는 상수도 시스템을 효율적으로 운영하기 위한 방법을 관망운영의 측면에서 모색하였으며, 수도권 광역상수도를 대상으로 하여 시범 적용하였다. 본 연구는 현재 시점에서 안정적인 용수공급이 가능한 가능최소 에너지 비용을 구하는 것이 목적이다 용수수요량의 변화 등 운영여건이 바뀌게 되면, 수리적 안정성이 확보되는 범위내에서 가능한 최적의 펌프운영패턴을 도출하였다. 현재 용수공급량 변동시 또는 연계운영 방법의 변경시와 같은 운영여건 변동에 따른 경제적운영 방안 등에 대한 연구가 미비하여 가장 최적의 운영방안 도출이 어려운 실정이므로, 본 연구를 통하여 연계운영에 최적화 기법의 적용 및 운영방안의 도출을 수행하였다. 운영여건의 변경시 펌프장 등에서의 전력원단위 변화 등 각 단계별 수도시설의 종합적 고려를 통한 경제적 운영방안을 검토할 수 있는 상수관망 최적운영모형의 실제 탑재 모델을 개발하였으며, 이를 기반으로 하여 실제 현장에서 담당자가 쉽게 사용할 수 있는 사용자 편의 환경을 개발하였다.

  • PDF

Investigation of Pump Wavelength Dependence of Long-Wavelength-Band Erbium-Doped Fiber Amplifier using 1530nm-Band Pump (L 대역 EDFA 특성의 펌프 파장 의존성에 관한 연구)

  • Choi, Bo-Hun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.7
    • /
    • pp.1249-1255
    • /
    • 2008
  • 1530nm band has been studied as pump wavelength for long-wavelength-band erbium-doped fiber amplifier (L-band EDFA). The pump source is built using a tunable light source and cascaded conventional-band (C-band) EDFA. The L-band EDFA uses a forward pumping scheme. Within the 1530nm band, 1545nm pump demonstrates 0.45dB/mW gain coefficient, which is twice better than that of conventional 1480nm pumped EDFA. The noise figure of 1530nm pump is at worst 6.36dB, which is 0.75dB higher than that of 1480nm pumped EDFA. Such high gain coefficient indicates that the L-band EDFA consumes low power.

Studies on the Application of Unit-inverter Parallel Operation to Sea-water Lift Pump in Power Plant (단위 인버터 병렬운전에 의한 발전소 해수펌크 적용)

  • 김수열;류홍우
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.3 no.1
    • /
    • pp.1-7
    • /
    • 1998
  • Due to the increase in capacity of auxiliary machinery in power plant, the importance of energy saving has been greatly emphasized. If the speed of fans or pumps is controlled in accordance with the variation of load, large electric energy can be saved. Large capacity inverter, 2MVA GTO inverter, has been developed by operating two of 1MVA unit inverters in parallel. The parallel operation of the unit inverter is accomplished through two output transformers of which the secondary windings are connected in series. The system is composed of one control cubicle, one rectifier cubicle and 2 unit inverter cubicles. This inverter system was applied to the sea water lift pump(SLP) driven by a 6.6KV 1500KW induction motor in Seo-Inchon power plant to save the electric energy. The parallel operation of inverters by 180 degrees apart in switching frequency helps to reduce the harmonic components.

Development of Vibration Monitoring System of Simulator for Power Plant (발전소 운전원 훈련용 시뮬레이터에서의 Vibration Monitoring System 개발)

  • 이명수
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.241-244
    • /
    • 2000
  • 한전은 국가경제 성장에 따라 늘어나는 발전설비에 대한 운영효율의 향상과 고장발생의 예방 사고시 운전원들의 운전능력 배양 등을 목적으로 운영요원 훈련용 시뮬레이터를 국산화 개발하여 운영하고 있다 훈련용 시뮬레이터를 구성하는 시스템들 중 발전소 안전계통과 발전소 감시계통을 시뮬레이션하는 PPC(Plant Processing Computer) 시스템이 있다 VMS(Vibration Monitoring System) 는 PPC의 여러계통들 중 하나로서 발전소의 터빈 발전기 펌프 등의 진동을 감시하는 시스템이다 본 논문에서는 시뮬레이터의 VMS를 개발하기 위해 적용한 시뮬레이tus 모델 알고리즘 그리고 모델에서 계산된 진동값을 PC의 모니터에 나타내는 Display 시스템등에 대해 기술하고자한다.

  • PDF

A Study on the Application of protective relay diagnostic and the power system analysis of power substation (수변전설비 보호계전진단 및 전력계통해석 적용방안에 대한 연구)

  • Lee, Kyung;Roh, Sang-Chun;Park, Min-Su
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.577-578
    • /
    • 2015
  • 펌프 전동기 기동특성과 전력계통해석 프로그램의 현장 실무 적용으로 전동기 부하가 다수인 수용가에 있어서의 보호계전기의 최적 설정방안을 제시하고자 한다.

  • PDF

development of High Vacuum pump system (고진공 펌프 시스템 개발에 관한 연구)

  • Kim, Soo-Yong;Lee, Oh-Keol
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.316-318
    • /
    • 2001
  • In this paper, the basic characteristics of flat fluorescent lamp using ultraviolet generated from gas discharge and powder type electrolyminescent display(P-ELD) using a phenomenon of the light emission eaused by the electrical field applied to phosphor are studied. The lamp is a simple structure with insulator layer, phosphor layer, and gas gap. Current(displacement current + discharge current) in flat fluorescent lamp using.

  • PDF

Complementary Dual-Path Charge Pump with High Pumping Efficiency in Standard CMOS Logic Technology (상보형 전하이동 경로를 갖는 표준 CMOS 로직 공정용 고효율 전하펌프 회로)

  • Lee, Jung-Chan;Chung, Yeon-Bae
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.46 no.12
    • /
    • pp.80-86
    • /
    • 2009
  • In this paper, we present a new charge pump circuit feasible for the implementation with standard twin-well CMOS process technology. The proposed charge pump employs PMOS-switching dual charge-transfer paths and a simple two-phase clock. Since charge transfer switches are fully turned on during each half of clock cycle, they transfer charges completely from the present stage to the next stage without suffering threshold voltage drop. During one clock cycle, the pump transfers charges twice through two pumping paths which are operating alternately. The performance comparison by simulations and measurements demonstrates that the proposed charge pump exhibits the higher output voltage, the larger output current and a better power efficiency over the traditional twin-well charge pumps.