• Title/Summary/Keyword: 펌프 시일

Search Result 545, Processing Time 0.026 seconds

A Study on Development of Shutoff Operating System of Ultra-High Pressure Positive Displacement Pump (초고압 용적형 펌프의 체절운전시스템 개발에 관한 연구)

  • Min, Se-Hong;Kim, Ho-Chul;Sung, Gi-Chan
    • Fire Science and Engineering
    • /
    • v.30 no.2
    • /
    • pp.106-113
    • /
    • 2016
  • Ultra-high pressure positive displacement pump can discharge high pressure water with mass volume, which depends on periodic changes in volume that made by rotation motor. Its high efficiency of discharge is one of the most strong point of positive displacement pump. Due to its simple system structure, it can be miniaturized and lightened. Positive displacement pump can discharge high pressure with stable flow rate, irrespective of pressure fluctuate. This is the reason that positive displacement pump was used instead of centrifugal pump. In this study, shutoff operating system was developed for positive displacement pump to secure safety of high pressure operate. This shutoff system contains controller system, electronic clutch, and relief valve, and each part is mutual supplementation. Speed test was carried out in order to check operation of controller program and electronic clutch and fluid flow, venting experiment of the relief valve. It was confirmed that segment system of ultra-high pressure positive displacement pump is operated.

Experimental Study of Energy-Saving Realized with the Improvement of Inner Roughness in Double-Entry Centrifugal Pump (양흡입 원심펌프의 내부 표면 거칠기 개선에 따른 에너지 절감 실험 연구)

  • Lim, Sung-Eun;Sohn, Chang-Hyun;Ryu, Jung-Yup
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.6
    • /
    • pp.409-415
    • /
    • 2016
  • In this study, we test the effects of the surface roughness on the hydro efficiency of double-suction centrifugal pumps ($Q=70.7m^3/min$, H = 87 m). The original surface of the impeller and inner casing were coated, resulting in surface-roughness reductions ranging from $100{\sim}110{\mu}m$ to $0{\sim}0.08{\mu}m$. We conducted experimental studies to measure the efficiency of the pumps and operating-pump electro energy variations with different surface roughness values. The experimental results showed that the efficiency of the pumps increased by about 0.8~1.79% and the electric energy of the operating pump was reduced by around 4.38 ~ 6.08%. These results indicate that the performance of the pumps depend largely on the surface roughness of the impeller and inner casing, and by reducing the surface roughness, we can improve the efficiency of the pump and reduce costs by reducing the electric energy consumption.

Analysis of Flow Characteristics in Pump Sump by Floor Cone Anti-Vortex Device Installation (원뿔 형태의 와류발생저감장치 설치로 인한 펌프 흡수조 내 흐름특성 변화 분석)

  • Byeon, Hyunhyuk;Kim, Heejung;Kim, Seojun;Yoon, Byumgman
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2017.05a
    • /
    • pp.73-73
    • /
    • 2017
  • 최근 기후변화에 따른 집중호우로 도시홍수의 피해가 급격히 증가하고 있다. 특히 인구가 밀집하고 교통량이 많은 대도시의 경우 동일한 호우에 대하여 녹지나 농경지 등에 비해 그 피해가 더 심각하다. 일반적으로 홍수 피해의 직접원인은 외수로 인한 피해와 내수로 인한 피해로 크게 구분할 수 있다. 외수피해는 주로 소하천 및 지천의 범람, 제방의 붕괴 등으로 발생한 것이며 내수피해는 배수로, 하수도 및 펌프장의 내수배제능력 부족이 주된 원인이다. 따라서 도시홍수를 효과적으로 방어하기 위해서는 우선적으로 내배수시설의 성능개선이 선행되어야 할 필요가 있다. 이러한 내배수 시설 중 빗물펌프장은 흡수조로 우수를 유도한 후 펌프를 이용하여 하천으로 배수하고 있다. 우수를 원활히 하천으로 배수하기 위해서는 흡수조 내 흐름이 안정적으로 형성되어야 한다. 하지만 갑작스런 폭우 등으로 인하여 우수가 짧은 시간에 집중될 경우 흡수조 내에서 빠른 유속과 불규칙한 흐름이 발생하여 와류가 생성된다. 이러한 와류는 펌프 입구로 공기를 유입시켜 효율 저하의 원인이 되며, 공동현상을 발생시켜 펌프의 손상을 초래하기도 한다. 따라서 와류발생 저감장치(Anti-Vortex Device)를 설치하여 와류의 생성을 억제하고자 하는 연구들이 수행되었으며, 그 결과 다양한 형태의 와류발생 저감장치가 소개되었다. 하지만 와류발생 저감장치의 명확한 설계기준이 제시되어 있지 않으며, 와류발생 저감장치를 설치하였을 때 효율이 얼마만큼 증가하는가에 대한 실험적인 자료가 제시되어 있지 않다. 따라서 본 연구에서는 원뿔 형태의 와류발생 저감장치 설치 전 후의 흐름특성을 분석하여 원뿔형태의 와류발생 저감장치가 흐름안정에 얼마나 효과가 있는지를 확인하기 위하여 PIV(Particle Image Velocimetry) 기법을 이용한 유속분포와 와도를 분석하여 흐름 안정 효과를 정량적으로 검토하였다. 그 결과 와류 발생을 저감할 수 있었으며, 정량적으로 와도가 감소하여 펌프 흡입량이 증가됨을 확인하였다. 향후 추가적으로 다양한 형태의 와류발생 저감장치에 대한 효과를 검토한다면 최적의 펌프 흡수조 설계에 도움이 될 것으로 기대한다.

  • PDF

광역상수도 관련 취수장 및 가압장의 운영자료 조사 및 분석

  • 노형운;박종문;이영범;이영호
    • The KSFM Journal of Fluid Machinery
    • /
    • v.5 no.2 s.15
    • /
    • pp.73-80
    • /
    • 2002
  • 운영 자료의 조사$\cdot$분석을 위해 수도권 광역상수도의 취수장, 가압장 및 정수장들을 발문하여 각 펌프장에서 관리하고 있는 운전일보, 기기이력카드 등과 한국수자원공사에서 발간하는 월보 및 년보와 각 단계별 실시설계 보고서 및 준공도소를 수집하여 통계 처리한 결과를 요약하여 보면 다음과 같다. 각 단계별 수도권 광역상수도의 취수량 및 송수량은 운영을 시작한 초기부터 1990년까지 증가하다가 점점 수량이 감소하는 추세이다. 팔당 1 취수펌프장은 계획 취수량의 $95.5\%$, 2 취수펌프장은 $89.8\%$를 공급한 후 계속 감소되었고 설계 시 $100\%$의 용수량을 만족시키지 못하고 있다. 이러한 현상은 최근 IMF로 인하여 건설경기 둔화와 용수 수요량이 감소하였을뿐만 아니라 지방자치단체별로 취수펌프장을 독자적으로 건설하여 수요량 감소가 심화되었기 때문인 것으로 판단된다. 각 단계별 광역상수도 중 펌프의 운전토출압력과 운전흡입압력으로 부터 전양정을 계산하여 보면 설계된정격양정보다 낮은 수치인 저양정$\cdot$대유량으로 운전되고 있음을 알 수 있다. 이러한 운전은 캐비테이션을 발생시키고 이로 인하여 임펠러에 침식이나 균열이 발생하여 10년에 한번씩은 임페러를 교체한 것으로 나타났다. 그리고 펌프의 교체 주기는 $15\~20$년인 것으로 조사되었다.

A Study of Chill-down Process in 30 tonf Turbopump-Gas Generator Coupled Tests (30톤급 터보펌프-가스발생기 연계시험에서 예냉 절차 연구)

  • Moon, Yoon-Wan;Nam, Chang-Ho;Kim, Seung-Han
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2012.05a
    • /
    • pp.447-450
    • /
    • 2012
  • An analysis of chill-down process was performed for 30 tonf Turbopump-Gas generator coupled tests. The chill-down process must be fulfilled before liquid rocket engine test using cryogenic propellant. Cavitation, damage and/or combustion instability due to bubble of propellant must be eliminated by chill-down process in a test specimen, especially cryogenic pump. The analysis of test data obtained by 30 tonf TP-GG coupled tests was performed in order to be based on the test process of KSLV-II liquid propellant rocket engine which will be developed. To macroscopically understand the process of chill-down from the viewpoint of test procedure the temperatures of important part and total time of chill-down process were analyzed.

  • PDF

Runoff simulation for operation of small urban storm water pumping station under heavy storm rainfall conditions (집중호우 시 도시 소유역 배수펌프장 운영을 위한 강우유출모의)

  • Gil, Kyung-Ik;Han, Jong-Ok;Kim, Sung-Geun;Lee, Chang-No;Kim, Goo-Hyeon
    • Journal of Wetlands Research
    • /
    • v.8 no.2
    • /
    • pp.75-81
    • /
    • 2006
  • In this study, runoff simulation was carried out in order to derive operational improvement of small urban storm water pumping station under heavy storm rainfall conditions. The flood inflow hydrograph of Guri city heavy storm in July, 2001 was successfully simulated by HEC-HMS, a GIS-based runoff simulation model. For the runoff simulation, ArcView, as an effective GIS tool, was used to provide input data of the model such as land use data, soil distribution data and SCS runoff curve number.

  • PDF

Studies on Raw-Water Source Heat Pump Equipped with Thermal Storage Tank in Water Treatment Facility (정수장 내 축열조 설치 원수열원 히트펌프의 성능분석)

  • Oh, Sun Hee;Yun, Rin;Cho, Yong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.5
    • /
    • pp.467-472
    • /
    • 2013
  • A raw-water source heat pump equipped with a thermal storage tank was dynamically simulated by TRNSYS, and the results were verified by using the data from a heat pump installed in the Seongnam water treatment facility. The average coefficient of performance (COP) of the raw-water source heat pump based on simulation was 4.97 and 3.17 in the cooling and heating season, respectively. When the volume of the thermal storage tank was changed from 5 to $20m^3$, the highest COP was found at a size of $10m^3$. Considering the regional locations of raw-water source heat pumps at Seoul, Incheon, Gangneung, and Gwangju, Seoul showed the lowest electric power consumption in the cooling season and the highest in the heating season. When a comparison of the performance between the present system and that of a water-air heat pump was conducted, the present system showed lower electric power consumption by 25% than that of a water-air heat pump.

Design and fundamental test on the cargo pump sump scaled model of tankers (탱크선 카고 펌프장 축소모델 설계 및 기초 실험)

  • Lee, Jo-Yeon;Kim, Seung-Jun;Chen, Zhenmu;Singh, Patrick Mark;Choi, Young-Do
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.41 no.1
    • /
    • pp.31-35
    • /
    • 2017
  • The internal flow of a pump system that is installed in the interior of large vessels such as tankers is largely affected by the water level and flow conditions of the pump sump. However, the performance of the pump is generally evaluated with the consideration of only the performance of the pump itself, without considering the pumping station operating environment. Therefore, if the pump is affected by the incoming flow that exhibits vortex and swirl, the occurrence of vortex and swirl accompanied with air may cause problems with the pump sump. This effect of flow condition can lead to a decrease in efficiency, increase in vibration, and noise generation in the pump. In this study, to investigate the internal flow of the pump sump according to several water levels, a pump sump scale-model was designed and constructed. The frequency of vortex occurrence and the shape of the vortex were investigated according to the different water levels of a fundamental test. The Class C vortex type, which has a larger volume of air intake to the pump, was confirmed by the higher occurrence frequency at a relatively lower water level.

진공펌프 배기속도 측정 방식에 따른 구조적 오차 및 보정

  • In, Sang-Ryeol
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.169-169
    • /
    • 2011
  • 진공펌프의 성능을 나타내는 여러 파라미터가 있지만 가장 중요한 성능지표는 역시 배기속도라고 할 수 있다. 배기속도는 물리적으로 체적유량(volume flow rate, L/s 또는 m3/hr) 즉 단위시간당 펌프 흡기구에 들어오는 기체의 체적을 가리킨다. 펌프 흡기구 단면을 지나가는 체적을 직접 측정하는 것은 거의 불가능하므로 진공 전문가들은 흡기구로 들어가는 기체 유량(flow rate, mbar${\cdot}$L/s 또는 Pa${\cdot}$m3/s)과 흡기구 압력(mbar 또는 Pa)을 측정한 후 유량을 압력으로 나누어 주는 방식으로 배기속도를 측정한다. 유량은 표면 기체 방출을 고려하더라도 실용적인 측면에서 보면 위치에 상관없이 불변하는 값으로 볼 수 있어서 유량을 어떻게 정밀하게 잴 것인가 하는 방법만 있으면 편리한 위치에서 측정하면 된다. 반면에 압력을 정밀하게 측정하는 방식은 확립되어 있지만 막상 어디서 측정하는 것이 옳은가 하는 것은 의외로 쉽지 않다. 펌프의 배기속도를 측정하는 상황을 몇 가지로 가정해 보면, 규격에 입각한 표준용기에 달아 정식으로 재는 것, 게이지가 부착된 마구리판을 달고 간이로 재는 것, 펌프가 사용되고 있는 시스템 현장에서 재는 것이 있을 수 있고 펌프가 달려 있는 상태도 직접 용기에 달거나, 도관 또는 어댑터 및 밸브를 통해 달리는 경우가 있다. 앞에서 펌프 배기속도 계산 시 사용하는 흡기구 압력이란 엄밀히 말하면 흡기구를 바라보는 방향으로 가해지는 압력을 말하는데 이는 진공 게이지를 펌프 흡기구 면에서 상류를 향하도록 놓을 때 얻을 수 있는 값으로 막상 실행하는 것은 어렵다. 표준용기의 구조는 진공 게이지를 특정 위치에 달 때 마치 흡기구 면에 놓인 게이지처럼 흡기구 압력을 정확하게 측정할 수 있도록 고안된 것이지만 때에 따라서는 여러 변형된 측정 방식을 사용할 수밖에 없는 상황이 만들어지므로 어떤 보정을 거치면 올바른 배기속도 값을 구할 수 있는지 살펴볼 필요가 있다.

  • PDF

2단 GM형 맥동관 냉동기 적용 크라이오 펌프 개발

  • Go, Jun-Seok;Park, Seong-Je;Go, Deuk-Yong;Kim, Hyo-Bong;Hong, Yong-Ju;Yeom, Han-Gil;Gang, Min-Jeong;Gang, Sang-Baek
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.85-85
    • /
    • 2011
  • 반도체 생산 공정은 청정 환경을 요구하며, 이를 위해서는 고진공 환경이 필수적인 요소이다. 반도체 생산 라인의 고진공 환경 조성을 위해서는 주로 복합 분자 펌프와 크라이오 펌프가 사용되고 있다. 본 연구에서는 기존의 상용 크라이오 펌프에 사용되던 GM 극저온 냉동기를 맥동관 냉동기로 대체하기 위한 연구를 수행하였다. 맥동관 냉동기는 저온부에 움직이는 부분이 없어 진동이 작고, 신뢰성이 높은 장점이 있어 이를 이용한 크라이오 펌프는 반도체 생산 공정의 공정 정밀도 향상에 기여할 수 있을 것으로 기대된다. 맥동관 냉동기는 크라이오 펌프에 사용하기 위하여 2단으로 구성되며, 저온부가 U자 형상으로 개발되었다. 상용화를 고려하여 로터리 밸브와 위상조절기구가 위치하는 상온부는 일체형으로 제작하였다. 제작된 맥동관 냉동기의 기초 냉각 성능 시험 결과 부하가 없는 조건에서 최저도달온도는 1단과 2단에서 각각 42.53 K과 8.68 K 이었으며, 부하 시험 결과 1단과 2단에서 각각 40 W at 82.97 K, 10 W at 20.51 K의 냉각 능력을 갖는 것으로 측정되었다. 개발된 맥동관 냉동기에 복사차폐막 및 1차, 2차 냉각판을 설치하여 크라이오 펌프를 구성하였고, 기체 질소에 대한 배기 속도 측정 시험을 수행하였다. 배기속도 측정 결과 배기속도는 2차 냉각판의 형상에 크게 영향을 받는 것이 확인되었으며, 약 650 L/의 배기속도를 갖는 것으로 측정되었다. 실험 결과를 바탕으로 크라이오 펌프로 작동시 맥동관 냉동기의 동작 특성 및 배기 속도 향상을 위한 방안을 논의하였다.

  • PDF