Modeling and Simulation of O2/CH4 Gas Supply System of Afterburner for Fuel-rich Gas of Gas Generator (가스발생기의 연료과잉가스 후연소용 O2/CH4 가스 공급시스템 설계)

  • Wang, Seungwon;Lee, Kwangjin;Chung, Yonggahp;Han, Yeoungmin
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • 제18권2호
    • /
    • pp.86-92
    • /
    • 2014
  • Combustion Chamber Test Facility (CCTF) to be constructed in Naro Space Center for re-burning the fuel-rich gas of gas generator have afterburner system. The afterburner system is supplied the Oxygon ($O_2$) gas and Methane ($CH_4$) gas to reduced the harmful exhaust gas. The detailed design for the planned CCTF afterburner system is simulated and analysed by AMESim program through the all of gas supply system components. Afterburner system is performed to verify the pipe size, orifice diameter, and gas supply conditions according to the total gas consumption from analysis of gas supply system.

HAZOP Study for Risk Assessment and Safety Improvement Strategies of CO2 Separation Process (HAZOP 기법을 이용한 이산화탄소 분리 공정 위험성 평가 및 안전도 향상 전략)

  • You, Chanhee;Kim, Jiyong
    • Korean Chemical Engineering Research
    • /
    • 제56권3호
    • /
    • pp.335-342
    • /
    • 2018
  • Various technologies to cope with the energy and environmental issues related to the chemical and electric power industry are in development and demonstration stage. Especially, the absorption process of carbon dioxide ($CO_2$) using amine solution is a key technology of the $CO_2$ capture and storage (CCS). In this study, we identify the major risk factors and suggest strategies for safety improvement by analyzing and assessing commercial the amine-based $CO_2$ separation process. HAZOP method was used to assess the risk for the process. We provide facilities and operational strategies to mitigate or eliminate major risk factors by assessing the relative ranks of identified risk factors using a risk matrix.

The Characteristics of Two Phase Flow by Non-Newtonian Fluid for Vertical Up-ward in a Tube (수직 상향유동 배관에서 비뉴톤유체에 의한 2상류의 유동특성)

  • Cha K.O.;Kim J. G.;Che K.S.
    • Journal of the Korean Institute of Gas
    • /
    • 제2권4호
    • /
    • pp.53-59
    • /
    • 1998
  • Flow pattern of air-water two phase flow depends on the conditions of pressure drop, void fraction, and channel geometry. Drag reduction in the two phase flow can be applied to the transport of crude oil, phase change systems such as chemical reactor, pool and boiling flow, and to present cavitation which occurs in pump impellers. But the research on drag reduction in two phase flow is not intensively investigated. Therefore, experimental investigations have been carried out to analyze the drag reduction produced and void fraction by Co-polymer(A611p) addition in the two phase flow system. We find that the maximum point position of local void friction moves from the wall of the pipe to the center of the pipe when polymer concentration increases. Also we find that the polymer solution changes the characteristics of the two phase flow. And then we predict that it is closely related with the drag reduction.

  • PDF

A study on Quantitative Supply of Sewage Sludge for Co-Incineration of Municipal Solid Waste and Sewage Sludge(II) - Based on Actual Incineration Plant (하수슬러지와 생활폐기물 혼합소각시 하수슬러지 정량공급에 관한 연구(II) - 실증플랜트 중심으로)

  • Cho, Jae-Beom;Kim, Woo-Gu;Jang, Hoon
    • Journal of Korean Society of Environmental Engineers
    • /
    • 제35권12호
    • /
    • pp.960-966
    • /
    • 2013
  • In this study, operation data from an actual plant in M city were analyzed to evaluate effects of water supply into sewage sludge on the co-incineration of municipal solid waste (MSW) and sewage sludge. Design capacity of the stoker incinerator is 50 m3/day. Maximum portion of sewage sludge in the total waste input was 20%. According to this research, moisture content increase up to 85% of sewage sludge could be possible by water supply on MSW input to the incinerator. Therefore, stable operation of incinerator could be achieved. As water was added into sewage sludge up to 85%, input quantity of sewage sludge to frequency (Hz) was similar to theoretical input. Also, it is concluded that stable management of incinerator without leachate combustion and damages of refractory bricks and castable could be achieved by the reduction of low heating value.

A Study on Application Analysis Using RETRAN Computer Code for the Environmental Qualification Flood Analysis Following the Main Feed Water Line Break (주급수관 파단에 따른 내환경검증 침수분석용 전산코드 RETRAN의 적용 해석연구)

  • Park, Young-Chan;Cho, Cheon-Hwey;Hong, Sung-In
    • Journal of Energy Engineering
    • /
    • 제16권3호
    • /
    • pp.103-112
    • /
    • 2007
  • Flood issue for nuclear power plants designed and built in 1970 is extremely severe for main steam header compartment and main feedwater line region of intermediate building and lower floor. A calculation for flood level at the main feedwater line isolation compartment is now performing by hand calculation. But, this methodology is quite conservative assumption. The goal of this study was to develop method to analyze flowrate using the RETRAN-3D computer code, and the developed method was applied to flood level analysis following main feedwater line break. As a result of analysis, flood level was low remarkably.

Eddy Current Testing of Weldment by Plus(+) Point Probe (Plus(+) Point Probe를 이용한 용접부 와전류검사)

  • Lee, Hee-Jong;Kim, Yong-Sik;Nam, Mim-Woo;Yoon, Byung-Sik;Kim, Seok-Kon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • 제19권6호
    • /
    • pp.426-432
    • /
    • 1999
  • A plus-point eddy current test(ECT) probe was developed to examine the defects on the welds of pumps, valves, and pipings which are the major components of the electric power plants, non-destructive evaluation (NDE) techniques for detecting and sizing the flaws were studied adapting this probe. Differential plus-point ECT probe is consists of two "I"-type coils crossed each other and has an advantage having a small influence on the sensitivity by lift-off variation to the conventional types of probe. The specimens with crack-like electro discharge machining(EDM) notches on the weld of type 304 stainless-steel were fabricated in order to evaluate the plus-point ECT probe response to the flaws. NDE techniques to detect and size the flaws and estimate the flaw type were established with this specimens.

  • PDF

Liquid Oxygen Supercooling System in the 75 tonf-class Liquid Engine Combustion Test Facility (75톤급 액체엔진 연소시험설비의 액체산소 과냉각 시스템)

  • Seo, Daeban;Yoo, Byoungil;Lee, Jungho;Cho, Namkyung;Kim, Seunghan;Han, Yeoungmin
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 한국추진공학회 2017년도 제48회 춘계학술대회논문집
    • /
    • pp.1080-1083
    • /
    • 2017
  • In the design of KSLV-II, there is a scenario in which supercooled liquid oxygen is supplied to prevent a geysering phenomenon in the oxidizer pipe and a cavitation phenomenon at the pump inlet. To verify this condition in the engine development test phase, a system that supplies supercooled liquid oxygen to the engine was applied in the engine combustion test facility. In this system, supercooling methods using a vacuum ejector and using helium injection to the tank were appied. Both tests were carried out for about 17 minutes. Supercooling results of about 3.3K for the ejector test and about 2.2K for the helium injection test were obtained at the 50% level of the tank.

  • PDF

Study on the Pressure Loss of Hoses in a Fire Hose Reel Hydrant (호스릴옥내소화전 호스에 대한 압력손실에 관한 연구)

  • Whang, Young-Kwon;Lee, Seung-Chul
    • Fire Science and Engineering
    • /
    • 제33권2호
    • /
    • pp.63-67
    • /
    • 2019
  • In this study, the pressure loss of a fire hose reel hydrant was examined and the effects of each factor on the pressure loss were analyzed. First, in the pressure loss experiment according to the length of the reel hose, the pressure loss increased with increasing length of the reel hose; it was approximately 38.86% based on a 25 m hose. Second, the pressure loss of the reel hose per unit length was estimated to be $.13{\sim}.15kgf/cm^2$. Third, in the pressure loss experiment according to the change in the flow rate, the result was similar to the relation, flow rate - pressure loss (${\Delta}P{\sim}Q^2$), in the piping flow. These results provide basic data on the evaluation of fire pump pressure and the performance-based fire-protecting design of fire hose reel hydrants used in buildings.

Sprinkler System with Universal Solenoid Valve (범용 전자개방밸브를 적용한 스프링클러설비)

  • Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • 제5권3호
    • /
    • pp.351-357
    • /
    • 2019
  • This research is automatic Wet Pipe Sprinkler System, dry pipe Sprinkler System, preaction Sprinkler system, vacuum Sprinkler system, deluge Sprinkler system, etc., key components of each Sprinkler system, verve valve, valve, etc. This is to simplify the various processes of the manufacturing process into a single process to create an environment in which a single machine can simultaneously produce a standardized product, thereby improving the price competitiveness of the product, reducing the cost of maintaining the product, and making it more adaptable to the new sprinkler system that is developed in the future. Automatic Wet Pipe Sprinkler System, desipe Sprinkler System, preaction sprinkler system, vacuum Sprinkler system, deluge Sprinkler system, both types of existing Sprinkler system, only replace the primary and secondary tubing valves.It has the advantage of being easy to apply to the lower system. Legal and institutional research is needed for the commercialization of the Sprinkler system applying the solenoid valve as a future project.

Construction and Tests of the Vacuum Pumping System for KSTAR Current Feeder System (KSTAR 전류전송계통 진공배기계 구축 및 시운전)

  • Woo, I.S.;Song, N.H.;Lee, Y.J.;Kwag, S.W.;Bang, E.N.;Lee, K.S.;Kim, J.S.;Jang, Y.B.;Park, H.T.;Hong, Jae-Sik;Park, Y.M.;Kim, Y.S.;Choi, C.H.
    • Journal of the Korean Vacuum Society
    • /
    • 제16권6호
    • /
    • pp.483-488
    • /
    • 2007
  • Current feeder system (CFS) for Korea superconducting tokamak advanced research(KSTAR) project plays a role to interconnect magnet power supply (MPS) and superconducting (SC) magnets through the normal bus-bar at the room temperature(300 K) environment and the SC bus-line at the low temperature (4.5 K) environment. It is divided by two systems, i.e., toroidal field system which operates at 35 kA DC currents and poloidal field system wherein 20$\sim$26 kA pulsed currents are applied during 350 s transient time. Aside from the vacuum system of main cryostat, an independent vacuum system was constructed for the CFS in which a roughing system is consisted by a rotary and a mechanical booster pump and a high vacuum system is developed by four cryo-pumps with one dry pump as a backing pump. A self interlock and its control system, and a supervisory interlock and its control system are also established for the operational reliability as well. The entire CFS was completely tested including the reliability of local/supervisory control/interlock, helium gas leakage, vacuum pressure, and so on.