• Title/Summary/Keyword: 펌프 배관

Search Result 131, Processing Time 0.022 seconds

Combustion Characteristics of Full-scale Gas Generator for 30 ton Class Liquid Rocket Engine (30톤급 실물형 가스발생기 연소 특성)

  • Ahn, Kyu-Bok;Seo, Seong-Hyeon;Lim, Byoung-Jik;Kim, Jong-Gyu;Lee, Kwang-Jin;Han, Yeoung-Min;Choi, Hwan-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.129-132
    • /
    • 2008
  • Combustion characteristics of a gas generator for a 30 ton-class liquid rocket engine were studied. At the early stage of development, the combustion tests of the gas generator were performed by only using the nozzle which substitute for a turbine manifold exit. Then, the extension tube was applied between the gas generator and the nozzle for imitating the resonant mode of gas generator and turbine manifold. Finally, the hot-firing tests were performed on the condition of connecting the gas generator with the turbine manifold. In the paper, the step-by-step results such as temperature distribution and pressure fluctuations were analyzed.

  • PDF

Numerical Analysis on the Heat Transfer Characteristics of HDPE Pipe with the Variation of Geometries for Ground Loop Heat Exchangers (지중열교환기의 고밀도폴리에틸렌 배관 형상에 따른 열전달 성능 특성에 대한 수치해석적 연구)

  • Mensah, Kwesi;Choi, Jong Min
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.12 no.4
    • /
    • pp.33-39
    • /
    • 2016
  • A ground source heat pump (GSHP) system is recommended as a heating and cooling system to solve the pending energy problem in the field of air conditioning, because it has the highest efficiency. However, higher initial construction cost works as a barrier to the promotion and dissemination of GSHP system. In this study, numerical analysis on the characteristics of high density polyethylene (HDPE) pipe with spiral inside was executed. The heat transfer and flow characteristics of it were compared with those of a conventional smooth HDPE pipe. The heat transfer coefficient and pressure drop of the spiral HDPE pipe were higher than those of the smooth HDPE pipes at the same fluid flow rate. By decreasing the flow rate, the spiral HDPE pipe represented similar values of heat transfer coefficient and pressure drop to the smooth HDPE pipe. The lower flow rate of the spiral HDPE pipe comparing with it of the smooth HDPE pipe is estimated to reduce the length of the ground loop heat exchanger.

Development of a Dispersion Analysis Program for the Liquid Rocket Engine and its Application (액체로켓 엔진 성능 분산해석 프로그램의 개발 및 응용)

  • Park, Soon-Young;Nam, Chang-Ho;Seol, Woo-Seok
    • Aerospace Engineering and Technology
    • /
    • v.10 no.1
    • /
    • pp.63-69
    • /
    • 2011
  • In this study, we developed a dispersion analysis program of the gas-generator cycle liquid propellant rocket engine by expanding the mode analysis software(GEMAT). The performance dispersions of an engine that are arisen from the internal dispersion factors of engine's sub-components were formulated and solved to find the effects of each dispersion factor. We were also able to present the calculation method to find the required pressure margin for the compensation of those dispersion to satisfy the required performances of engine. Using this method, we could propose a novel procedure of compensating during the ground firing test which would induce the performance improvement by lessening the pumps discharge pressures or augmenting the combustion chamber pressure.

Energy Saving Effect for High Bed Strawberry Using a Crown Heating System (고설 딸기 관부 난방시스템의 에너지 절감 효과)

  • Moon, Jong Pil;Park, Seok Ho;Kwon, Jin Kyung;Kang, Youn Koo;Lee, Jae Han;Kim, Hyung Gweon
    • Journal of Bio-Environment Control
    • /
    • v.28 no.4
    • /
    • pp.420-428
    • /
    • 2019
  • This study is the heating energy saving test of the high-bed strawberry crown heating system. The system consists of electric hot water boiler, thermal storage tank, circulation pump, crown heating pipe(white low density polyethylene, diameter 16mm) and a temperature control panel. For crown heating, the hot water pipe was installed as close as possible to the crown part after planting the seedlings and the pipe position was fixed with a horticultural fixing pin. In the local heating type, hot water at $20{\sim}23^{\circ}C$ is stored in the themal tank by using an electric hot water boiler, and crown spot is partially heated at the setting temperature of $13{\sim}15^{\circ}C$ by turning on/off the circulation pump using a temperature sensor for controlling the hot water circulation pump which was installed at the very close to crown of strawberry. The treatment of test zone consisted of space heating $4^{\circ}C$ + crown heating(treatment 1), space heating $8^{\circ}C$(control), space heating $6^{\circ}C$ + crown heating(treatment 2). And strawberries were planted in the number of 980 for each treatment. The heating energy consumption was compared between November 8, 2017 and March 30, 2018. Accumulated power consumption is converted to integrated kerosene consumption. The converted kerosene consumption is 1,320L(100%) for space $8^{\circ}C$ heating, 928L(70.3%) for space $4^{\circ}C$ + crown heating, 1,161L($88^{\circ}C$) for space $6^{\circ}C$ + crown heating). It was analyzed that space $4^{\circ}C$ + pipe heating and space $6^{\circ}C$ + crown heating save heating energy of 29.7% and 12% respectively compared to $8^{\circ}C$ space heating(control).

Effects of Local Cooling and Root Pruning on Budding and Local Heating on Heating Energy Consumption in Forcing Cultivation of Strawberry (딸기 촉성재배 시 국소 냉방 및 단근처리와 국소난방이 화방출뢰와 난방에너지소비에 미치는 영향)

  • Kwon, Jin Kyung;Kang, Suk Won;Paek, Yee;Moon, Jong Pil;Jang, Jae Kyung;Oh, Sung Sik
    • Journal of Bio-Environment Control
    • /
    • v.28 no.1
    • /
    • pp.46-54
    • /
    • 2019
  • Experiments of local cooling and heating on crown and root zone of forcing cultivation of strawberry 'Seolhyang' using heat pump and root pruning before planting were conducted. During the daytime, the crown surface temperature of the crown local cooling treatment was maintained at $18{\sim}22^{\circ}C$. This is suitable for flower differentiation, while those of control and root zone local cooling treatment were above $30^{\circ}C$. Budding rate of first flower clusters and initial yields were in the order of crown local cooling, root zone local cooling and control in root pruning plantlet and non pruning plantlet, except for purchase plantlet. Those of root pruning plantlet were higher than those of non pruning plantlet. These trends were evident in the yield of the first flower cluster until February 14, 2018, and the effect of local cooling and root pruning decreased from March 9, 2018. The budding rates of the second flower cluster according to the local cooling and root pruning treatments were not noticeable compared to first flower cluster but showed the same tendency as that of first flower cluster. In the heating experiment, root zone local heating(root zone $20^{\circ}C$+inside greenhouse $5^{\circ}C$) and crown local heating(crown $20^{\circ}C$+inside greenhouse $5^{\circ}C$) saved 59% and 65% of heating fuel, respectively, compared to control(inside greenhouse $9^{\circ}C$). Considering the electric power consumption according to the heat pump operation, the heating costs were reduced by 55% and 61%, respectively.

A Study on Characteristics of Drag Reduction Additive under High Temperature Range (고온영역에서 계면활성제의 마찰저감 성능 특성에 관한 연구)

  • Cho, Sung-Hwan;Ryu, Jae-Sung;Jung, Sang-Hoon
    • Journal of Energy Engineering
    • /
    • v.19 no.2
    • /
    • pp.116-120
    • /
    • 2010
  • Overall total length of hydraulic pipe to transport the hot water in the domestic district heating network is above 3,000 Km approximately. This long pipe network requires a lots of the transport pumping power by surface friction of fluid. In this study, the drag reduction(DR) of Amin Oxide $C_{18}$ as non-ionic surfactant according to the fluid velocity, temperature and surfactant concentration under the condition of above $80^{\circ}C$ fluid temperature were investigated experimentally. Results showed that new amin oxide $C_{18}$ surfactant had DR of maximum 30% in fluid temperature of $80^{\circ}C$ and had 15% DR in fluid temperature over $100^{\circ}$ under short time test condition. And amine oxide had 155 hours duration time to keep the DR characteristic in the fluid temperature of $80^{\circ}$ and 1000 ppm concentration. But duration time of DR was decreased when fluid temperature increased.

Comparison of Flow Characteristics for the Development of a C-Type Strainer with Its Inlet and Outlet on a Straight Line (유입·유출구가 일직선상인 C형 스트레이너 개발을 위한 유동특성 비교)

  • Shin, Byung-kyun;Kwon, Chang-Hee
    • Journal of Digital Convergence
    • /
    • v.14 no.11
    • /
    • pp.257-265
    • /
    • 2016
  • The purpose of this study was to develop a strainer that could protect a flow system by blocking the introduction of foreign substances into the pipe of industrial or architectural facilities. Strainers are installed at the front tip of valves, machines, or pumps in the piping line of clean water, oil, or gas. There are Y-type, U-type, and T-type strainers. The study identified problems with the Y-type strainers, develop a "C-type strainer with its inlet and outlet on a straight line" as a more improved new model, and compared them in functions in a full-scale strainer test. The study conducted a full-scale strainer test according to four situations at the flow laboratory of Korea Research Institute of Standards and Science by using the old Y-type strainer and C-type strainer 50A. The test results show that the C-type strainer had a higher capacity coefficient(Kv) than the Y-type one, recording 74.9% when there was no screen, 54.5% when there were no foreign substances in the screen, 54.2% when there was a 15% accumulation of foreign substances, and 52.4% when there was a 30% accumulation of foreign substances. The investigator conducted a test only with the 50A type due to the limitations of life-size strainers, but the results demonstrate that the C-type strainer had better flow characteristics than the Y-type one.

변환시설 발생 해체금속폐기물의 용용제염처리

  • Hwang, Du-Seong;Kim, Dong-Ho;Lee, Gyu-Il;Choe, Yun-Dong;Park, Jin-Ho;Jeong, Un-Su
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2009.06a
    • /
    • pp.63-64
    • /
    • 2009
  • 변환시설의 해체 시 발생한 해체폐기물은 2009년 현재까지 약 354톤이며, 이들 중 탱크, 배관, 반응기, 펌프류 동의 해체금속폐기물이 약 191톤으로 54% 를 차지하고 있다. 이들 해체금속폐기물은 제염 처리공정을 통하여 전량 자체처분폐기물로 전환시키는 것을 목표로 두고 있다. 이는 오염된 금속류를 효과적으로 제염한 다음 자체처분시킴으로서 방사성폐기물에 대한 처분비용을 저감할 수 있기 때문이다. 해체금속폐기물 중 스테인레스강 해체폐기물은 질산 용액을 사용한 초음파화학제염공정으로 제염한 후 자체처분폐기물로 53톤을 전환하였다. 탄소강 해체물의 경우 스팀제염공정으로 제염한 결과 제영 효율은 좋았으나 변환시설 가동 중 유지 보수를 위하여 페인팅을 하였던 해체물의 경우 페인트를 제거하지 않을 경우 스팀제염장치로는 제염이 안 되었다. 탄소강 해체금속폐기물은 약 117톤 발생하였으며, 이들 중 모터, 펌프 등을 제외한 제염 대상 폐기물은 약 80톤이며, 이들을 용융 제염 및 감용을 위하여 기초 연구를 수행한 결과를 바탕으로 약 180kg/batch 용량의 금속용융제염 설비를 제작 설치하여 탄소강 해체금속폐기물 용융제염 처리를 수행 중에 있다. 금속용융은 장치가 간단하고 폐기물 처리량이 비교적 적고 단속적인 운전에 매우 효과적인 고주파 유도로를 사용하였다. 용융장치는 고주파 발진장지와 용해로체로 구성된 고주파 유도설비와 냉각계통으로 구성된다. 고주파발진장치는 철제 200kg을 용해할 수 있는 용량을 갖추었으며, 실험 및 실제 처리 등 용해로체의 크기 변경이 필요할 경우에는 고주파발진기의 출력 주파수를 변경할 수 있게 하였다. 용융 장치의 발진기 부분의 입력전원은 3상, 440V, 60Hz 이며, 출력전원은 200kW, 출력주파수는 lkHz, 3kHz, 5kHz로 구성되어 있으며, 회당 180kg 의 폐기물을 용융할 시에는 3kHz로 고정하여 사용하였다. 용해로체 부분 중 고주파유도가열부는 heating coil 및 절연부로 구성되어 있고, 그 외 support frame과 lever로 구성되어 있다. 용해로체와 고주파 발진장치의 냉각을 위한 냉각설비는 냉각기와 냉매의 저장을 위한 저장조로 구성되어 있으며, 냉각기의 용량은 20RT 이다. 용융로체의 직경은 약 28cm로 크기가 큰 해체물의 장입이 어려워 작은 크기로 세절을 해야만 하며,용융로의 용량을 증가시킬 경우 해체물을 작은 크기로 세절하는 비용을 절감할 수 있을 것이다. 용융 중 시료 채취는 매 배치마다 수행하였으며, 그림3과 같은 시료 채취용 주형 틀에 국자모양의 채취기로 채취하였다. 해체물의 용융시 ingot를 생성하기 위해서 주형틀에 용융물을 장입하기 전 시료를 채취하였다 그림4는 생성된 ingot이며, 이들의 방사능 농도는 배치마다 차이는 있지만 최대 0.05 Bq/g 이하로 나타나 자체처분 폐기물로 전량 전환 가능하였다 그림5 는 해체물에 함유된 우라늄과 불순물을 제거한 슬래그로 방사능농도는 약 12Bq/g 으로 나타났으며, 이들의 발생량은 약 3wt% 정도로 폐기물 발생량이 작았다. 따라서 금속폐기물의 경우 용융제염으로 처리할 경우 폐기물 발생량을 최대로 줄일 수 있어 처리 효율이 기타 처리 공정보다 효율적인 것으로 판단된다.

  • PDF

An Analysis of the Application Technology of Heat Recovery System from Dyeing Wastewater (염색폐수 열회시스템 적용기술 분석)

  • 장기창;박성룡;이상남;라호상;박준택;함성원;박영태
    • Journal of Energy Engineering
    • /
    • v.10 no.3
    • /
    • pp.195-205
    • /
    • 2001
  • A great deal of energy is necessary with emission of lots of wastewater in dyeing and finishing process, but heat recovery from wastewater is not introduced since is technology is not developed yet. In order to obtain the method utilizing hot water produced by heat source, that is, dyeing wastewater it was investigated the characteristics of dyeing and finishing process and energy basic unit. Energy basic unit of polyester/cotton (T/C), polyester/rayon (T/R) and polyester dyeing process are higher than that of the other process. The average quantity of wastewater for each dyeing company is 20,470 ton/month, the average temperature of wastewater is about 41$^{\circ}C$. Because the SS solution of wastewater in polyester dyeing process is lower than that of the other process, the effect of corrosion in heat recovery system is low. Since the energy price for 1000 kcal produced by vapor compression heat pump is presumed to be 22.50 won, it is found to be very economic heat recovery system, and its payback is 2.09 years for the factory with LNG boiler.

  • PDF

An experimental study on the improving noise characteristic of hydraulic power unit (유압동력 발생장치의 소음특성 개선을 위한 실험적 연구)

  • Lee, Gi Chun;Lee, Yong Bum
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.6
    • /
    • pp.638-643
    • /
    • 2013
  • Nowadays, the hydraulic power unit (HPU) has been increased its working pressure and enlarged its capacity in order to improve the performance of the hydraulic system, but it produces noise leveled around 110dB(A) during operation. Recently, due to the reinforcement of industrial safety regulations and the requirement of improving work environment, a separated HPU room is installed at outside or underground of the building as to reduce the noise from HPU, but there are also problems of power loss owing its fluid friction of pipe system and of deficient accessibility during its failure accident. In this study, experiment is performed to improve the noise characteristics with installing a soundproof chamber to minimize the power loss and exclude effectively the high leveled noise, which is generated during the power conversion of HPU.