• Title/Summary/Keyword: 펄스 레이저 용발

Search Result 3, Processing Time 0.014 seconds

Enhancement of Pulsed-Laser Ablation by Phase Explosion of Liquid (액체의 상폭발 과정에 의한 펄스 레이저 용발률의 증진)

  • Kim, Dong-Sik;Lee, Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.11
    • /
    • pp.1483-1491
    • /
    • 2001
  • Enhancement of pulsed-laser ablation by an artificially deposited liquid film is presented. Measurements of ablation rate, ablation threshold, and surface topography arc performed. Correlation between material ablation and photoacoustic effect is examined by the optical beam deflection method. The dependence of ablation rate on liquid-film thickness and chemical composition is also examined. The results indicate that photomechanical effect in the phase explosion of liquid is responsible for the enhanced ablation. The low critical temperature of liquid induces explosive vaporization with localized photoacoustic excitation in the superheat limit and increases the ablation efficiency. Experiments were carried out utilizing a Q-swiched Nd:YAG laser at near-threshold laser fluences with negligible plasma effect (up to ∼100 MW/cm$^2$).

Decontamination Characteristics of 304 Stainless Steel Surfaces by a Q-switched Nd:YAG Laser at 532 nm (532 nm 파장의 큐스위치 Nd:YAG 레이저를 이용한 스테인리스 스틸 표면 제염특성)

  • Moon, Jei-Kwon;Baigalmaa, Byambatseren;Won, Hui-Jun;Lee, Kune-Woo
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.8 no.3
    • /
    • pp.181-188
    • /
    • 2010
  • Metal surface decontamination characteristics were investigated by using a laser ablation method. A second harmonic generation of a Q-switched Nd:YAG laser with a wave length of 532 nm, a pulse energy of 150 mJ and a pulse width of 5 ns was employed to assess the decontamination performance for metal surfaces contaminated with $CsNO_3$, $Co(NH_4)_2(SO_4)_2$, $Eu_2O_3$ and $CeO_2$. The ablation behavior was investigated for the decontamination variables such as a number of laser shots, laser fluence and an irradiation angle. Their optimum values were found to be 8, 13.3 J/$cm^2$ and $30^{\circ}$, respectively. The decontamination efficiency was different depending on the kinds of the contaminated ions, due to their different melting and boiling points and was in the order: $CsNO_3>Co(NH_4)_2(SO_4)_2>Eu_2O_3>CeO_2$. We also evaluated a correlation between the metal ablation thickness and the number of laser shots for the different laser fluences.

Study on increasing the mass resolution in aerosol TOF mass spectrometer by using post focusing method (후집속 방법을 이용한 에어로졸 TOF 질량분석기의 질량분해능 향상 연구)

  • Kim, Dukhyeon;Yang, Kiho;Cha, Hyungki;Kim, Dohoon;Lee, Sang Chun
    • Analytical Science and Technology
    • /
    • v.18 no.6
    • /
    • pp.483-490
    • /
    • 2005
  • Mass resolution of the time of flight aerosol mass spectrometer for an aerosol component analysis depends on the initial direction and the initial energy of the ions. We have found that the shape of the optimum post focusing electric field is not linear. The maximum electric potential should be applied to the ions whose initial direction is 90 degree. To check on the post focusing effects, we have installed a laser ablation mass spectrometer. By using this LA-MS, we have found that the average energy distribution of the laser ablated ions is 8 eV. To establish the optimum mass resolution, a time delay and a high voltage are needed, and the results of the study show that 1500 nsec, and 3.7 kV are the optimum parameters for our system respectively. The isotope mass signals of copper show a good resolution.