• Title/Summary/Keyword: 펄스형$CO_2$ 레이저

Search Result 23, Processing Time 0.021 seconds

Comparison of Wound Healing in Porcine Skin with Continuous-Wave and Pulsed Mode $CO_2$ Laser Incisions (돼지에서 연속형 $CO_2$ 레이저와 펄스형 $CO_2$ 레이저를 이용한 피부절개시 창상치유 평가)

  • Lee, Jae-Yeon;Cho, Sung-Whan;Park, Chang-Sik;Kim, Myung-Cheol
    • Journal of Veterinary Clinics
    • /
    • v.27 no.6
    • /
    • pp.647-651
    • /
    • 2010
  • The advantages of the $CO_2$ laser are offset by the delay in laser wound healing secondary to thermal damage. To minimize the undesirable thermal damage of the $CO_2$ laser, investigators have developed technical advances in the delivery system of the laser energy. This study compared tissue healing of the continuous and the pulsed modes $CO_2$ laser wounds in an animal surgery model. Five healthy Landrace and Yorkshire mixed breeds of both genders were used (45-51 kg, 4-6 months old, three males and two females). A full thickness wound of skin ($2{\times}2{\times}2cm^2$) was made over on the each pig's both sides of dorsal midline at 0, 7, 14, and 18 days. The wounds created at 18, 14, 7 and 0 days were named post-wounding day (PWD) 3, 7, 14 and 21, respectively. In each pig, one wound (left side) was treated pulsed $CO_2$ laser and the other wound (right side) was treated continuous wave $CO_2$ laser. Each wound was closed with two interrupted suture of 3-0 sutures. At 21 days after initial wounding, each wound was taken for histological evaluations. The degrees of reepithelialization were performed more prominently in the pulsed mode group than in the continuous mode group. The degrees of granulation were greater significantly in pulsed mode group than those in the continuous mode on PWD 3 (p < 0.05). The degrees of fibroblasts in the pulsed mode group were greater significantly in comparison to those in the continuous mode group on PWD 7, (p < 0.05). In conclusion, reepithelialization, granulation and fibroblasts in the pulsed mode group were greater markedly in comparison to those in the continuous mode group. It was considered that pulsed mode $CO_2$ laser was more suitable for the skin incision than the continuous mode $CO_2$ laser.

A Study on the pulsed $CO_2$ laser by the switching control of leakage transformer primary (누설변압기 1차측의 스위칭 제어에 의한 펄스형$ CO_2$ 레이저에 관한 연구)

  • 정현주;이동훈;김도완;이유수;김중만;김희제
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2000.08a
    • /
    • pp.100-101
    • /
    • 2000
  • 최근에 100Hz 이하의 펄스 반복율을 가지는 20 W급 출력의 의료용 및 마킹용 펄스 $CO_2$레이저의 수요가 증가함에 따라 유지와 보수의 편리성은 물론 사용자의 편의성을 충족시키기 위한 레이저 전원장치의 소형화, 출력 제어의 용이성 및 저가격화 등에 대한 요구가 증대되고 있다. 기존의 펄스형 $CO_2$레이저의 전원장치는 원하는 펄스 반복율에 맞도록 스위칭 소자를 "on"-"off"하여 콘덴서에 충전된 에너지를 고압 펄스 트랜스를 통해서 레이저 방전관에 인가하는 방식이다. 즉 DC를 스위칭 과정을 통해 펄스 에너지로 변환시킨 후 방전관에 그 펄스에너지를 공급하는 형태이다$^{(1)}$ . (중략)

  • PDF

A study on the improved efficiency of pulsed Nd:YAG laser adopted ZCC Method (ZCC 방식을 적용한 펄스형 Nd:YAG 레이저의 효율개선에 관한 연구)

  • Hong, Jung-Hwan;Moon, Dong-Sung;Jung, Jong-Han;Kim, Hwi-Young;Kang, Wook;Kim, Hee-je
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2000.08a
    • /
    • pp.220-221
    • /
    • 2000
  • 가공용 레이저로는 $CO_2$, 루비, Nd:YAG, 아르곤 이온 레이저 등이 이용되고 있으며, 이중 펄스형 Nd:YAG 레이저는 $CO_2$ 레이저와 함께 레이저 가공에 널리 사용되는 고체 레이저로서 마킹(making), 트리밍(trimming), 리페어링(repairing) 등의 정밀 가공 분야에서 많은 실용화가 이루어져 왔다.$^{(1)}$ $CO_2$ 레이저의 경우 매질가스로 $CO_2$, $N_2$, He 등을 사용해야하므로 취급 및 유지보수가 불편하지만, 열전도율이 높고, 기계적 광학적으로 안정된 Nd:YAG 레이저는 램프에 의한 광 여기 방식이므로 유지보수가 쉽다. 또한 광 출력의 제어가 용이하며, 광파이버에 의한 빔 전송이 가능하여 산업기술 및 의료 분야에서의 적용이 더욱 더 확대되고 있다.$^{(2)}$ (중략)

  • PDF

Design and evalution of pulsed $CO_2$ laser system using high repetition ratio and high precision (고반복율 및 고정밀방식을 이용한 펄스형 $CO_2$ Laser 시스템 설계 및 평가)

  • 김흥수;김휘영
    • Journal of the Korea Computer Industry Society
    • /
    • v.2 no.8
    • /
    • pp.1055-1062
    • /
    • 2001
  • Study, it is the purpose to develope a cheap and compact pulsed $CO_2$ laser with pulse repetition rate range of 1 KHz. We used a IGBT switched power supply as a power supply, which is cheap and simple comparing to others. PIC one-chip microprocessor was used for precise control of a laser power supply on the control part. And the laser cavity was fabricated as an axial and water cooled type. The laser performance characteristics as various parameters, such as pulse repetition rate, gas pressure, and gas mixture rate have been investigated. The experiment was done under the condition of total pressure of $CO_2$$N_2$:He = 1:3:10, 1:1.5:5, 1:9:15 from 6 Torr to 15 Torr and pulse repetition rate from 100 Hz to 900 Hz. As a result, the maximum average outpu was about 20.5 W at the total pressure of 15 Torr, the gas mixture $CO_2$$N_2$:He = 1:9:15 and the pulse repetition rate of 700 Hz.

  • PDF

The development of power supply of High-Repetition Pulsed $CO_2$ Laser using SMPS (SMPS 방식의 고반복 펄스형 $CO_2$ 레이저의 전원장치 개발)

  • 이동훈;정현주;김도완;김희제
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2000.02a
    • /
    • pp.316-317
    • /
    • 2000
  • 펄스형 $CO_2$레이저는 적외선 영역인 10.6 $mu extrm{m}$ 파장의 매우 안정된 고출력 펄스를 방출시킬 수 있으므로 산업용, 군사용, 의료용, 각종 물리.화학의 기초 연구용 등의 광범위한 응용 분야에서 각광을 받고 있다. 특히 금속의 정밀절단, 심용접에서는 수 십 Hz로부터 수 kHz의 펄스 출력이 필요하다. 펄스방식은 Normal Pulse와 Super Pulse로 크게 나눌 수 있다. Normal Pulse의 경우에는 Pulse의 파고치가 연속파의 파고치와 동일하기 때문에 펄스시의 평균 출력은 연속파의 경우보다 낮다. Super Pulse의 경우에는 Pulse 파고치를 연속파의 파고치보다 훨씬 높게 할 수 있으므로 평균 출력은 낮지만 첨두 출력이 높아서 유리 등 세라믹 재료의 가공에 널리 사용된다$^{(1)}$ (중략)

  • PDF

Design and embodiment of stable system by change of action waveform by pulsemodule special quality of pulse style$CO_2$ laser for obstetrics and gynecology (산부인과용 펄스형 $CO_2$레이저의 펄스모듈 특성과 동작파형 변화에 따른 안정된 시스템의 설계 및 구현)

  • Kim, Whi-Young
    • Journal of the Korea Computer Industry Society
    • /
    • v.8 no.2
    • /
    • pp.97-102
    • /
    • 2007
  • [ $CO_2$ ] laser sees that is most suitable to get this effect through minimum formation damage and advantage that is root enemy of effect that happen in minimum cellular tissue depth of 0.1mm is stable living body organization or internal organs institution. Formation damage by ten can be related in formation's kind or energy density, length of evaporation time. If shorten evaporation time, surroundings cellular thermal damage 200 - because happen within 400um laser beam in rain focus sacred ground surroundings cellular tissue without vitiation me by evaporation Poe of very small floor as is clean steam can . Application is possible to vulva cuticle cousins by a paternal aunt quantity, uterine cancer, cuticle tumor by laser system that $CO_2$ laser gets into standard in obstetrics and gynecology application. Because effect that super pulse output is ten enemies of laser if uniformity one pulse durations are short almost is decreased, most of all pulse module special quality of Pulse style $CO_2$ laser for obstetrics and gynecology mode stabilization by weight very, in this research to get into short pulse duration and higher frequency density, do switching by high frequency in DC-DC Converter output DC's ripple high frequency to be changed, high frequency done current ripple amount of condenser for output filter greatly reduce can . Ripple of output approximately to Zero realization applying possible inductor realization through a special quality experiment do.

  • PDF

Design and Implementation of Dermatology $CO_2$ Laser System (피부과용 $CO_2$레이저시스템의 설계 및 구현)

  • Kim, Whi-Young
    • Journal of the Korea Society of Computer and Information
    • /
    • v.6 no.2
    • /
    • pp.8-13
    • /
    • 2001
  • We demonstrate a pulsed CO$_2$laser with long pulse duration of millisecond order in the low pressure less than 30 Torr. A new power supply for our laser system switches the voltage of AC power line(60㎐) directly. The power supply doesn't need elements such as a rectified bridge, energy-storage capacitors. and a current-limiting resistor in the discharge circuit. In order to control the laser output power, the pulse repetition rate is adjusted up to 60㎐ and the firing angle of SCR gate is varied from 30˚ to 150˚. A ZCS(Zero Crossing Switch) circuit and a PIC one-chip microprocessor are used to control the gate signal of SCR precisely. The maximum laser output is 23W at the total pressure of 18 Torr, the pulse repetition rate of 60㎐, and SCR gate firing angle of 90˚. In addition, the obtained laser pulse width is approximately 3㎳(FWHM)

Special quality research by pulse transformer stabilization by high tension output module of medical ultra series laser II (산부인과용 $CO_2$ 연속형 레이저의 고압출력 모듈에 따른 펄스트랜스 안정화 특성연구(II))

  • Kim, Whi-Young
    • Journal of the Korea Computer Industry Society
    • /
    • v.8 no.1
    • /
    • pp.49-56
    • /
    • 2007
  • Various kind of laser had been used on addition to endoscope for obstetrics and gynecology, gas laser such as CO2 laser had been used mainly much in laparoscope surgical operation mainly Thermal effect of beam displays other result different component parts of cellular tissue and different close of a marketplace of laser beam and priority solidification of temperature increase consists in cellular tissue, and cutting or carbonization process happens and evaporation by breakdown of cellular tissue happens more than $300^{\circ}$. <중략> Ostabilization of pulse transformer by high tension output module of CO2analog laser for obstetrics and gynecology that accomplish marks of honor kind switching and accuracy is required, and stabilize with laser output applying Turn-off in existent hard switching forward converter, on city happened switching damage, damage increase of output diode station recovery special quality, parasitism shock, design and result that manufacture, brought result that improve than existing product. Will be bought to get into superior result if supplement as systematic late.

  • PDF

System of stable action waveform by pulse special quality of obstetrics and gynecology pulse style $CO_2$ laser (산부인과 펄스형 $CO_2$ 레이저의 펄스 특성에 의한 안정된 동작파형의 시스템)

  • Kim, Whi-Young
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.55-57
    • /
    • 2007
  • $CO_2$ laser sees that is most suitable to get this effect through minimum formation damage and advantage that is root enemy of effect that happen in minimum cellular tissue depth of 0.1mm is stable living body organization or internal organs institution. Formation damage by ten can be related in formation's kind or energy density, length of evaporation time. If shorten evaporation time, surroundings cellular thermal damage 200 - because happen within 400ums laser beam in rain focus sacred ground surroundings cellular, tissue without vitiation me by evaporation Poe of very small floor as is clean steam can. Application is possible to vulva cuticle cousins by a paternal aunt quantity, uterine cancer, cuticle tumor by laser system that $CO_2$ laser gets into standard in obstetrics and gynecology application. Because effect that super pulse output is ten enemies of laser if uniformity one pulse durations are short almost is decreased, most of all pulse module special quality of pulse style $CO_2$ laser for obstetrics and gynecology mode stabilization by weight very, in this research to get into short pulse duration and higher frequency density, do switching by high frequency in DC-DC Converter output DC's ripple high frequency to be changed, high frequency done current ripple amount of condenser for output filter greatly reduce can. Ripple of output approximately to Zero realization applying possible inductor realization through a special quality experiment do.

  • PDF

Fixed system of action waveform by pulse module special quality of obstetrics and gynecology pulse style $CO_2$ laser relationship embodiment (산부인과 펄스형 $CO_2$ 레이저의 펄스모듈 특성에 의한 동작파형의 일정한 시스템의 구현)

  • Kim, Whi-Young
    • Proceedings of the KIEE Conference
    • /
    • 2007.04c
    • /
    • pp.159-161
    • /
    • 2007
  • $CO_2$ laser sees that is most suitable to get this effect through minimum formation damage and advantage that is root enemy of effect that happen in minimum cellular tissue depth of 0.1mm is stable living body organization or internal organs institution. Formation damage by ten can be related in formation's kind or energy density, length of evaporation time. If shorten evaporation time, surroundings cellular thermal damage 200 - because happen within 400ums laser beam in rain focus sacred ground surroundings cellular tissue without vitiation me by evaporation Poe of very small floor as is clean steam can. Application is possible to vulva cuticle cousins by a paternal aunt quantity, uterine cancer, cuticle tumor by laser system that $CO_2$ laser gets into standard in obstetrics and gynecology application. Because effect that super pulse output is ten enemies of laser if uniformity one pulse durations are short almost is decreased, most of all pulse module special quality of pulse style $CO_2$ laser for obstetrics and gynecology mode stabilization by weight very, in this research to get into short pulse duration and higher frequency density, do switching by high frequency in DC-DC Converter output DC's ripple high frequency to be changed, high frequency done current ripple amount of condenser for output filter greatly reduce can. Ripple of output approximately to Zero realization applying possible inductor realization through a special quality experiment do.

  • PDF