Reverse Analysis on a Direct Dive Servo Valve with Electric Feedback (전기 피드백 직동형 서보 밸브에 관한 역 분석)

  • Kim, S.D.;Ahn, H.W
    • Journal of Drive and Control
    • /
    • v.10 no.4
    • /
    • pp.22-28
    • /
    • 2013
  • Mechanical and electrical properties of a DDV(Direct Drive servo Valve) with electric feedback are analysed via reverse analysis technique in this work. The DDV is disassembled and mechanical parameters, such as spool mass, spring stiffness and port size are identified. The servo amplifier, which is built in the valve, is reversely analysed and the control scheme and gains for several control actions are also identified. The electrical feedback for spool displacement improves much better the valve performance, such as hysteresis and dynamic bandwidth frequency, than an ordinary mechanical feedback valve. Integrating control action with very large gain was adopted in the valve amplifier, and it seemed to give high performance.

FPGA Implementation of High Speed Multi-Channel PWM (멀티채널 고속 PWM의 FPGA 구현)

  • 김창수;박성모
    • Proceedings of the IEEK Conference
    • /
    • 1999.11a
    • /
    • pp.959-962
    • /
    • 1999
  • 예전에 일반적인 DC모터제어 또는 전류 량 제어 분야에만 사용되던 펄스 폭 변조기 형태의 부품이 근래에는 멀티미디어 단말장치의 한 부품으로 사용되고 있는데 본 논문에서는 비디오 신호처리 및 영상보드에서 간편하게 사용될 수 있는 PWM 모듈을 설계하였다. 단말장치의 주변 칩에서 사용되는 일반적인 내장형 모듈을 사용하게 되면, 멀티채널을 요하는 시스템에서 채널의 부족으로 인해 여러 개일 마이크로 콘트롤러를 사용해야 하는 단점이 있다. 이 때문에 내장형으로 사용될 수도 있으며, 독립적으로도 동작할 수 있는 구조가 필요하며 정적으로 동작해야 하는 시스템에도 이식될 수 있는 기능도 동시에 가지고 있어야 한다. 본 논문에서는 이러한 기능을 만족시키기 위한 진보된 PMW 모듈의 구조를 제안하였으며, 이를 VHDL로 기술하여 기능을 검증하고, XC4010XL-PC84 FPGA로 구현하였다.

  • PDF

Single-Stage APWM Half-Bridge Flyback Converter with Synchronous Rectifier (단일단 동기정류기형 APWM 하프브리지 플라이백 컨버터)

  • Park, Hae-Yong;Lee, Han-Mo;Kwon, Bong-Hwan
    • Proceedings of the KIPE Conference
    • /
    • 2011.07a
    • /
    • pp.360-361
    • /
    • 2011
  • 본 논문에서는 단위역률과 고효율을 갖기 위한 단일단 동기정류기형 비대칭 하프브리지 플라이백 컨버터 회로를 제안한다. 제안된 회로에서는 역률 개선단을 통해 입력전류의 리플이 줄어들게 되며, 거의 단위역률에 가까운 고역률을 갖게 된다. 또한 비대칭 펄스폭 변조에 의한 하프브리지 플라이백 DC/DC 컨버터는 영전압 스위칭 (ZVS) 동작을 하게 되며, 출력단에 동기정류기를 사용하여 스위칭에 의한 손실을 줄였다. 출력전압 24V, 최대 출력 200W, 스위칭 주파수 100kHz에서 제안된 컨버터의 성능을 입증하기위해 실험이 진행 되었다.

  • PDF

A Study on Design and Development of the Electronically Controlled Power Steering Controller far a Passenger Car (승용차용 전자계어식 파워스티어링 콘트롤러의 설계 및 개발에 관한 연구)

  • 김광열;김태훈
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.10 no.4
    • /
    • pp.166-174
    • /
    • 2002
  • Power steering systems far automobile are becoming ever more popular because they reduce steering efforts of the drivers, especially during parking lot maneuver. In this paper, the controller of the motor driven hydraulic power steering(MDHPS) has been designed and developed. This system uses a power source of DC motor instead of engine power source for power steering drive oil pump. The developed MDHPS system is accomplished a highly sensitive power steering resulted from electronic control under variable driving condition. Furthermore, this system is more improvement than type of engine driving far fuel economy.

Modelling and Controller Design of Electro-Magnetic Valve for Vehicle Engine (차량 엔진용 전자기식 밸브의 모델링 및 제어기 설계)

  • Jung, Y.S.
    • Journal of Power System Engineering
    • /
    • v.6 no.4
    • /
    • pp.81-87
    • /
    • 2002
  • The modelling and controller design of the EMV(electro-magnetic valve) for vehicle engine are considered in this paper. For the analysis and controller design, the governing equation of the EMV system is derived. For a good performance of the system, the start control, the holding control and the swing control are included in the controller design of the EMV system. In order to reduce landing speed of the valve, the on-time delay control which mainly come from the optimal control theory is employed. In order to reduce the power consumption of the system, the pick-up and hold operation has been used for the magnetic coil. The simulation and experimental results are presented to show the validity of the control method.

  • PDF

Experimental Investigation on PWM control of Power-shift Transmission Hydraulic System (파워시프트 변속기 유압시스템의 PWM 제어 실험 연구)

  • Kim, D.C.;Lee, J.K.;Kang, Y.S.;Lee, J.C.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.6 no.3
    • /
    • pp.10-15
    • /
    • 2009
  • The major system of an agricultural power-shift tractor is the transmission, using power-shift. Because the transmission performance depends on the hydraulic control system, the most important aspect of the optimization is the design of the hydraulic control system. This study was conducted to improve a pressure modulation characteristics of the power-shift transmission hydraulic system. It has been tried to replace an existing pressure modulation method with a digital control by using HSSV(High Speed Solenoid Valve). The performance of the PWM control system in power-shift hydraulic transmission has been evaluated by means of experiment.

  • PDF

Design of a DC-DC Step-Down Converter for LED Backlight of Mobile Devices (휴대기기용 LED 백라이트를 위한 감압형 DC-DC 변환기 설계)

  • Son, Hyun-Sik;Lee, Min-Ji;Park, Won-Kyoung;Song, Han-Jung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.3
    • /
    • pp.1700-1706
    • /
    • 2014
  • In this paper, a step down converter for LED backlight of mobile application has been proposed. The converter which is operated with 4 MHz high switching frequency is capable of reducing mounting area of passive devices consists of a power stage and a control block. Circuit elements of the power stage are inductor, output capacitor, MOS transistors and feedback resistors. The control block consists of pulse width modulator, error amplifier and oscillator etc. Proposed step down converter has been designed and verified using a $0.35{\mu}m$ 1-poly 4-metal BCD process technology. Simulation results show that the output voltage is 1.8 V in 3.7 V input voltage, output current 100 mA which is larger than 25 ~ 50 mA in conventional 500 KHz driven converter when the duty ratio is 0.4.

Data Decision Aided Timing Tracker in IR-UWB System using PPM (PPM 변조방식의 IR-UWB 시스템에서 데이터 결정방식을 이용한 타이밍 추적기)

  • Ko, Seok-Jun
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.44 no.1
    • /
    • pp.98-105
    • /
    • 2007
  • In this paper, we propose a timing detector using suboptimal maximum likelihood method. The proposed method has an simple reference signal generator. Additionally, timing detector's gain of the proposed method is the same to Early-Late gate and ML method. We reveal that tracking range of time tracker is narrow because of using data-decision, that is, tracking range is ${\pm}0.06ns$ for the 4-order Gaussian monocycle with 0.7ns pulse width. Therefore we can find that searcher must have very accurate acquisition procedure. When estimating a performance of time tracker, we consider a jitter in transmitter and receiver's pulse generation process as well as background noise. By using computer simulation, we propose mean/variance of timing detector and tracking process. Also we consider a mobility in tracking process, i.e., timing error modeled ramp function. In order to propose a performance of time tracker, we consider only one correlation demodulator.

Control of Refrigerating Compressor Capacity Using Inverter (인버터를 이용한 냉동용 압축기의 용량 제어)

  • Yang, H.S.;Kim, H.S.;Kim, J.H.;Kim, S.B.;Kim, J.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.5 no.2
    • /
    • pp.94-101
    • /
    • 1993
  • Recently, efforts of decreasing energy consumption are continously increased and user's preference is also diversified in refrigeration and air conditioning systems. Thus, in order to satisfy these demands, high efficiency, high intelligence, and energy saving for those systems are essential. As the basic study for diverse functions and intelligence of those systems, we investigated the response characteristics through the compressor capacity control concerned with superheat and refrigeration room temperature. And, response characteristics are investigated experimentally by using micro computer based PWM inverter control method. Experimental result of the conventional on-off control method is given in order to be compared to the results of inverter control method. The results obtained through this study are summarized as follows. It is shown from the experimental results of the on-off control method that the range of temperature variation around the steady state ($-18^{\circ}C$) is very large (about $7{\sim}8^{\circ}C$) and the settling time bringing the steady state is not found. In the inverter control method, we can see that the refrigeration room temperature after reaching the setting temperature is very stable without fluctuation and a robust control for disturbance such as opening the door has been realized.

  • PDF

A Single-Phase Buck AC-AC Power Converter for Custom Power Applications (수용가 전원 응용을 위한 단상 Buck AC-AC 전력 변환기)

  • 강정식;최남섭
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2001.05a
    • /
    • pp.427-430
    • /
    • 2001
  • Computers and automated manufacturing processes in industry are very susceptible to voltage sags and surges. The need for greater power reliability makes the end-users to use the uninterruptible power supply and other electronic power conditioning means to maintain the stable voltage. In this paper, a single-phase buck ac-ac converter for Custom Power Applications is presented. The presented converter uses IGBT's as switching module and maintains the stable voltage through PWM technology in spite of the input voltage sags and load rejections. In this paper, the operation characteristics of the power converter at steady state are illustrated using PSPICE simulations.

  • PDF