• Title/Summary/Keyword: 펄스에코

Search Result 85, Processing Time 0.026 seconds

A Study on the Inspection of Orthotropy Composite Laminate plates Using Ultrasonics (직교이방성 복합적층판의 초음파 탐사에 관한 연구)

  • 나승우;임광희;양인영
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.583-586
    • /
    • 2000
  • This work ethibits how susceptive the shear ultrasonic waves are to a little misoriented plies according to the angle variation of shear ultrasoic waves $0^\circ$ , $45^\circ$ and $90^\circ$. Also, it is shown that shear waves, particularly the transmission mode with the transmitter and receiver perpendicular to each other, have high sensitivity for detecting anomalies in fiber orientation and ply layup sequence that may occur in the manufacturing of composite laminates. Experimental results are agreed with modeling solutions which were based on decomposition of shear wave polarization vector as it propagates through the composite laminates. This wave appeared considerably to be sensitive to CFRP composites to the thickness direction along in-plane fibers.

  • PDF

Determination of the Position and Velocity of the Solid-Liquid Interface During Directional Solidification of Metals based on Guided Ultrasonic Waves (유도초음파를 이용하여 금속의 방향성 고체화과정에서 고체-액체 경계면의 위치와 속도결정)

  • 김태진;슈마크텔미샤엘;그릴볼프강;쉬벤부쉬안드레;찜머만게르하르트
    • The Journal of the Acoustical Society of Korea
    • /
    • v.17 no.2
    • /
    • pp.79-83
    • /
    • 1998
  • 높은 온도에서 금속물질이 응고되는 동안에 물질의 구조는 결정성장속도비율에 따 라 크게 좌우된다. 유도초음파를 기초로 한 펄스-에코 초음파실험기술과 함께 고체-액체 경 계면의 위치와 속도를 실시간으로 측정할 수 있어 고체화되는 동안의 용광로 파라메터들을 조절하는데 사용될 수 있다. 실험은 Bridgman형의 용광로에서 CuMn-막대시료에 대하여 서로 다른 냉각비율로 수행되었다. 열적평형상태에서 경계면의 위치에 대한 측정분해능은 약10㎛이다.

  • PDF

Gamma-Variate Function을 이용한 관류강조영상(Perfusion MRI) 프로그램 개발 및 평가

  • 백현만;김대원;정성택;박민석;류완석;최환준;최보영
    • Proceedings of the KSMRM Conference
    • /
    • 2002.11a
    • /
    • pp.128-128
    • /
    • 2002
  • 목적: Gamma-Variate Function을 이용하여 뇌 관류에 관련하는 새로운 재구성 영상 (CBV, CBF, MTT, TTP, BAT)을 산출할 수 있는 프로그램을 개발 및 평가 대상 및 방법: 뇌 관류와 관련한 정량적인 재구성 영상(CBV, CBF, MTT, TTP, BAT)을 얻기 위하여 Gamma-Variate Function을 이용한 Post-processing 프로그램을 개발하였다. 자기공명영상은 1.5T & 3.0T Magnum (Medinus Co., Ltd.)을 사용하였으면, 개발된 프로그램 평가를 위해 스핀에코 -EPI 펄스시퀀스(TR 2000 ms, TE 80 ms, FOV 260 mm, matrix 92$\times$128)를 사용하여 관류강조영상을 획득하였다.

  • PDF

Study on Measuring the Acoustic Velocity Propagating Through the Polymeric Mterials in the Low Frequency Ranges (저주파 영역에서 고분자 재료의 음속 측정에 관한 연구)

  • 김창현;조국영;박정기
    • The Journal of the Acoustical Society of Korea
    • /
    • v.17 no.8
    • /
    • pp.58-63
    • /
    • 1998
  • 저주파 영역의 음파의 투과속도 측정에 기존의 펄스에코방법이나 투과법 (transmission method)가 이용되는 경우, 탐촉자 및 시편의 크기, 시편과 탐촉자 사이의 거 리가 사용하는 음파의 주파수가 작아질수록 대형화되어 측정에 어려움을 나타내게 된다. 따 라서 본 연구에서는 고분자 재료의 음향특성을 평가할 수 있는 간단한 방법으로써 고분자 재료의 주파수에 따른 동적 탄성률(dynamic modulus)을 시간-온도 중첩의 원리를 이용하여 측정하고, 고분자 내에서 저주파 영역의 음파의 전달 속도와 주파수에 따른 탄성율(elastic modulus), 전단 탄성률(shear modulus) 그리고 밀도의 관계식으로부터 음속을 측정하였다. 실험결과 주파수가 증가함에 따라 고분자 재료의 동적 탄성률이 증가하였으며, 음속도 주파 수에 따라 증가하였다. 본 연구에서 사용한 폴리우레탄 재료의 음속은 100Hz∼10kHz영역에 서 약1500m/sec에서 3000m/sec를 나타내었다.

  • PDF

Pulse-echo Response of Piezoceramic-Polymer 1-3 Type Composite Transducer for a Level Limit Switch Applications (Level Limit스위치용 1-3형 복합압전체 트랜스듀서의 펄스-에코응답특성)

  • Choi, H.I.;Sohn, M.H.;Kim, H.K.;Park, K.I.;SaGong, G.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05a
    • /
    • pp.224-228
    • /
    • 2002
  • In this study, the piezoelectric ceramics PZT powder was synthesized by the Wet-Dry combination method. Flexible 1-3 type composite specimens were fabricated with the piezoceramics PZT filler phase and Eccogel polymer matrix phase. This paper represents the pulse-echo response of the 1-3 type composite transducer to check it out to investigate a basic property regarding a level limit switch. The acoustic impedance of 1-3 type composite was improved than that of single phase PZT ceramics. The pulse-echo response of transducer fabricated with the self-made 1-3 type composites resonator was better than that of the solid PZT transducer.

  • PDF

Quantitative Nondestructive Evaluation of Bonded Joints utilizing Pulse-Echo Ultrasonic Test (펄스-에코법을 이용한 접착접합 시험편의 정량적 비파괴 평가)

  • Oh, Seung-Kyu;Hwang, Young-Taek;Lee, Won
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.3
    • /
    • pp.157-164
    • /
    • 2003
  • The pulse-echo method is one of the most widely used ultrasonic techniques for application of nondestructive evaluation. Particularly, quantitative nondestructive evaluation of defects has been considered more important to assure the reliability and the safety of structure. Frequency energy in adhesive joints is based on the ultrasonic wave analysis. The attenuation coefficient upon wave amplitude and the frequency energy that is expressed in the term of wave pressure amplitude were utilized for the primary wave experiment. By means of a control experiment, it was confirmed that the variation of the frequency energy in adhesive joints depends on transition by stress variation. In this paper, the ultrasonic characteristics were measured for single lap joint and Double Cantilever Beam specimen with different fracture modes that was subjected to stress. Consequently, the data that was obtained from the adhesive specimen was analytically compared to the fracture mechanics parameter

Diagnostic Imaging of Isolated Splenic Torsion in a German Shepherd Dog (독일셰퍼드 견에서 단독으로 발생한 비장 염전의 영상진단)

  • Lee, Ki-Ja;Jeong, Seong-Mok;Choi, Ho-Jung;Lee, Young-Won
    • Journal of Veterinary Clinics
    • /
    • v.28 no.6
    • /
    • pp.613-616
    • /
    • 2011
  • A 5-year-old male German shepherd dog was presented with a 4 day-history of anorexia and depression. Abdominal radiographs showed a large soft tissue mass and loss of serosal detail. Ultrasonographs revealed splenomegaly with the lacy pattern parenchyma, perivenous hyperechoic region at the splenic hilum, and loss of splenic venous flow. Computed tomographic findings included the enlarged non-enhanced spleen except perivenous region at the splenic hilum and a whirled soft tissue mass at the splenic hilum. Exploratory laparotomy confirmed the diagnosis of splenic torsion. Ultrasonographic findings including lacy appearance, hyperechoic perivenous echogenicity and absence of splenic blood flow and CT findings including no or minimal enhancement of the spleen and a whirled appearance of splenic pedicle could be useful for diagnosing isolated splenic torsion in the dog.

Detection of Laser Generated Ultrasonic Wave Using Michelson Interferometer (마이켈슨 간섭계를 이용한 레이저 여기 초음파의 검출)

  • Kim, Kyung-Cho;Yamawaki, Hisashi;Jhang, Kyung-Young
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.20 no.1
    • /
    • pp.27-32
    • /
    • 2000
  • In this paper, ultrasonic wave in the thermoelastic regime was generated in a steel disk by illuminating a pulse laser (Q-switched Nd:YAG) on the surface of the sample and was detected on the other side by Michelson interferometer which was stabilized by feed back control. The experimentally detected displacement waveform of the ultrasonic wave showed good agreement with the theoretically expected one. Also it was shown that sound speeds of longitudinal and shear wave were similar to ones measured by pulse-echo method using a contact transducer. As an application of the noncontact ultrasonic measurement by using laser based ultrasonics, the sound speed in the sample was monitored while the sample was heated in a furnace, and the result showed that it decreased according to the increase of sample temperature.

  • PDF

Development of the Automated Ultrasonic Flaw Detection System for HWR Nuclear Fuel Cladding Tubes (중수로형 핵연료 피복관의 자동초음파탐상장치 개발)

  • Choi, M.S.;Yang, M.S.;Suh, K.S.
    • Nuclear Engineering and Technology
    • /
    • v.20 no.3
    • /
    • pp.170-178
    • /
    • 1988
  • An automated ultrasonic flaw detection system was developed for thin-walled and short tubes such as Zircaloy-4 tubes used for cladding heavy-water reactor fuel. The system was based on the two channels immersion pulse-echo technique using 14 MHz shear wave and the specially developed helical scanning technique, in which the tube to be tested is only rotated and the small water tank with spherical focus ultrasonic transducers is translated along the tube length. The optimum angle of incidence of ultrasonic beam was 26 degrees, at which the inside and outside surface defects with the same size and direction could be detected with the same sensitivity. The maximum permissible defects in the Zircaloy-4 tubes, i.e., the longitudinal and circumferential v notches with the length of 0.76mm and 0.38mm, respectively and the depth of 0.04 mm on the inside and outside surface, could be easily detected by the system with the inspection speed of about 1 m/min and the very excellent reproducibility. The ratio of signal to noise was greater than 20 dB for the longitudinal defects and 12 dB for the circumferential defects.

  • PDF

Study on Thickness Measurement about Insulation Rubber of Steel Motor Case Using Ultrasonic Resonance (초음파 공진을 이용한 스틸 연소관의 내열 고무 두께 측정 기법 연구)

  • Kim, Dong-Ryun;Kim, Jae-Hoon
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.16 no.5
    • /
    • pp.89-96
    • /
    • 2012
  • The rubber side could be contaminated using the existing pulse echo method because the ultrasonic wave was incident on the rubber side from the interior of the steel motor case, which could lead to the critical disbond defect. To develop the test method which can be replaced the existing method, the ultrasonic wave was incident on steel face of the steel/rubber adhesive test block. Rubber resonance frequencies measured from the steel/rubber adhesive test block were in good agreement with theoretically predicted rubber resonance frequencies. This paper was described about the ultrasonic resonance method to convert the rubber resonance frequency into the rubber thickness.