• Title/Summary/Keyword: 펄스에코

Search Result 85, Processing Time 0.024 seconds

Pulse-echo Response of Ultrasonic Transducer Fabricated by Porous Piezoceramics PZT Resonator (다공질 압전소자(PZT)로 제작된 초음파 트랜스듀서의 펄스에코 응답특성)

  • Joo, Yong-Khoan;Lee, Su-Ho;Park, Jung-Hak;SaGong, Geon
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.358-360
    • /
    • 1995
  • PZT powders were prepared by the molten salt synthesis method. The porous PZT specimens were prepared from a mixture of PZT and polyvinylalcohol(PVA) powders by BURPS(Burnout Plastic Sphere) technique. The pulse-echo response of porous PZT transducer with various PVA wt.% were studied. The fall time of pulse-echo response of porous PZT transducer was shorten to that of solid PZT-maded transducer. Therefore, a good transmitting and receiving properties could be obtained. The distance between transducer and reflector was in good agreement both solid PZT and porous PZT fabricated transducer.

  • PDF

Separation of Superimposed Pulse-Echo Signal for Improvement of Resolution of Scanning Acoustic Microscope -Deconvolution Technique Combined with Wavelet Transform- (초음파 주사 현미경의 분해능 향상을 위한 중첩된 펄스에코 신호의 분리 기법(디컨볼루션과 웨이브렛 변환의 혼합기법))

  • 장경영;장효성;박병일
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.7
    • /
    • pp.217-225
    • /
    • 2000
  • Scanning Acoustic Microscope (SAM) is used as an important nondestructive test tool in semiconductor reliability evaluation and failure analysis. However, inspections of chip attach adhesive interface fer thin chip has proven difficulty as the reflected signals from the chip top and bottom are superimposed. In this paper, in order to overcome this difficulty, a new signal processing method based on the deconvolution technique combined with the wavelet transform is proposed. The wavelet transform complements a disability of deconvolution technique of which performance largely decreases when the waveform of target signal is not identical to that of reference signal. Performances of the proposed method are demonstrated by through computer simulations using model signal and experiments for the fabricated semiconductor samples, and satisfactory results are obtained.

  • PDF

Pulse-echo response of 1-3 type piezoelectric composite transducers for distance measurement (거리 측정용 1-3형 복합압전체 트랜스듀서의 펄스에코 응답 특성)

  • 최헌일;박정학;이수호;사공건
    • Electrical & Electronic Materials
    • /
    • v.8 no.2
    • /
    • pp.211-216
    • /
    • 1995
  • In this study, the piezoelectric ceramics/polymer composite transducers with 1-3 connectivity have been studied. A piezoelectric ceramics PZT prepared by Wet-Dry Combination method was used as a filler in polymer matrix Eccogel. We've got the pulse-echo response for 1-3 type piezc-electric composite transducers in water. It was shown that the transmitting and receiving sensitivity of 1-3 type piezoelectric composite transducers could be improved in comparison with that- of solid PZT transducers. The reason is for that 1-3 type Piezoelectric composites have low dielectric constant and density. There was in a good agreement between the resonant frequencies calculated from one period and observed results on the Ultrasonic Transducer Analyzer. According to these results we could be figured out the distance in water by virture of the pulse-echo response.

  • PDF

Pulse-echo Response of Piezoceramic-Polymer 1-3 Type Composite Transducers (압전 세라믹-고분자 1-3형 복합 압전체 트랜스듀서의 펄스에코 특성)

  • Choi, H.I.;Park, J.H.;Lee, S.H.;SaGong, G.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1403-1405
    • /
    • 1994
  • In this study, the piezoelectric transducers with 1-3 connectivity have maded. A piezoelectric ceramic PZT prepared by Wet-Dry Combination method is used as a filler in Eccogel polymer matrix. The pulse-echo response for 1-3 type composite transducers were carried out in water. It was observed that the transmitting and receiving sensitivity of 1-3 type composite transducers were improved in comparison with that or solid PZT transducer. The reason is for that 1-3 composites have a hish piezoelectric voltage coefficients, The period of pulse-echo response for the transducer is in a good agreement with the resonant frequency of self-maded composite transducer.

  • PDF

Pulse-echo Response of Piezoceramics PZT-Polymer 1-3-0 Type Composite (1-3-0형 복합압전체의 펄스-에코특성)

  • 양윤석;유영준;최헌일;손무헌;사공건
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.303-306
    • /
    • 1999
  • In this study, the piezoelectric ceramics PZT powder was synthesized by Wet-Dry combination method. The flexible 1-3-0 type composites were fabricated with piezoceramic PZT and Eccogel polymer matrix embedded 3rd phase. This paper represents the acoustic properties with various 3rd phase wt.%. The acoustic impedance of 1-3-0 type composites was lower than that of single phase PZT ceramics. The pulse-echo response of transducer fabricated with 1-3-0 type composites was better than solid PZT transducer.

  • PDF

Wavelet Transform Based Doconvolution of Ultrasonic Pulse-Echo Signal (웨이브렛 변환을 이용한 초음파 펄스 에코 신호의 디컨볼루션)

  • Jhang, Kyung-Young;Jang, Hyo-Seong;Park, Byung-Yll;Ha, Job
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.20 no.6
    • /
    • pp.511-520
    • /
    • 2000
  • Ultrasonic pulse echo method comes to be difficult to apply to the multi-layered structure with very thin layer, because the echoes from the top and the bottom of the layer are superimposed. We can easily meet this problem when the silicon chip layer in the semiconductor is inspected by a SAM equipment using fairly low frequency lower than 20MHz by which severe attenuation in the epoxy mold compound of packaging material can be overcome. Conventionally, deconvolution technique has been used for the decomposition of superimposed UT signals, however it has disabilities when the waveform of the transmitted signal is distorted according to the propagation. In this paper, the wavelet transform based deconvolution(WTBD) technique is proposed as a new signal processing method that can decompose the superimposed echo signals with superior performances compared to the conventional deconvolution technique. WTBD method uses the wavelet transform in the pre-stage of deconvolution to extract out the common waveform from the transmitted and received signal with distortion. Performances of the proposed method we shown by through computer simulations using model signal with noise and we demonstrated by through experiments for the fabricated semiconductor sample with partial delamination at the top of silicon chip layer.

  • PDF

Study on Application of Ultrasonic Propagation Imager for Non-destructive Evaluation of Composite Lattice Structure (복합재 격자 구조 비파괴평가를 위한 초음파전파 영상화 시스템 활용 연구)

  • Park, Jae-Yoon;Shin, Hye-Jin;Lee, Jung-Ryul
    • Composites Research
    • /
    • v.30 no.6
    • /
    • pp.356-364
    • /
    • 2017
  • Composite lattice structures are tried to be used in various fields because of its benefit in physical properties. With increase of demand of the composite lattice structure, nondestructive testing technology is also required to certificate the quality of the manufactured structures. Recently, research on the development of the composite lattice structure in Republic of Korea was started and accordingly, fast and accurate non-destructive evaluation technology was needed to finalize the manufacturing process. This paper studied non-destructive testing methods for composite lattice structure using laser ultrasonic propagation imaging systems. Pulse-echo ultrasonic propagation imaging system was able to inspect a rib structure wrapped with a skin structure. To reduce the time of inspection, a band divider, which can get signal in different frequency bands at once, was developed. Its performance was proved in an aluminum sandwich panel. In addition, to increase a quality of results, curvature compensating algorithm was developed. On the other hand, guided wave ultrasonic propagation imaging system was applied to inspect delamination in a rib structure. To increase an area of inspection, multi-source ultrasonic wave propagation image was applied, and defects were successfully highlighted with variable time window amplitude mapping algorithm. These imply that ultrasonic propagation imaging systems provides fast and accurate non-destructive testing results for composite lattice structure in a stage of the manufacturing process.

MR spectroscopy using single-shot RF localization technique (단일 RF 펄스를 사용한 3차원 체적 선택 방법을 이용한 MR 스펙트로 스코피)

  • Rim, C.Y.;Chun, K.W.;Ra, J.B.;Cho, Z.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1989 no.05
    • /
    • pp.51-54
    • /
    • 1989
  • In last several years, a number of volume localization techniques, such as ISIS, VSE, SPARS and STEAM etc., have been developed for the MR spectroscopy. These localizing techniques, however, require application of several RF pulses for the 3-D volume selection and suffer from T1 and T2 decays due to relatively long RF excitation time. In this paper, we propose a single-shot RF pulse localization technique to achieve the localized 3-D volume selection. This technique combines the cylindrical volume selection technique with a radial gradient coil with single-shot RF pulse and the oscillating selection gradient technique, so thai it minimizes the volume selection time. We report some experimental results obtained with the proposed method which appears promising for 3-D volume imaging and localized spectroscopy.

  • PDF

T1-, T2-weighted, and FLAIR Imaging: Clinical Application (T1, T2강조영상, FLAIR영상의 임상 적용)

  • Kim, Jae-Hyoung
    • Investigative Magnetic Resonance Imaging
    • /
    • v.13 no.1
    • /
    • pp.9-14
    • /
    • 2009
  • T1-, and T2-weighted imagings and FLAIR (fluid attenuated inversion recovery) imaging are fundamental imaging methods in the brain. T1-weighted imaging is a spin-echo sequence with short TR and short TE and produces the tissue contrast by different T1 relaxation times. In other words, short TR maximizes the difference of the longituidinal magnetization recovery between the tissues. T2-weighted imaging is a spin-echo sequence with long TR and long TE and produces the tissue contrast by different T2 relaxation times. Long TE maximizes the difference of the transverse magnetization decay between the tissues. FLAIR is an inversion recovery sequence using 180 degree inversion pulse. 2500 msec of inversion time is applied to suppress the CSF signal.

  • PDF

Development of Digital Telesounder (디지털 원격 어군탐지기의 개발에 관한 연구)

  • Sin, Hyeon-Ok;Hwang, Seung-Uk
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.34 no.2
    • /
    • pp.135-138
    • /
    • 1998
  • This paper describes the construction and experimetal results of prototype digital telesounder developed to monitor remotely the fish school entered in setnet. The telesounder consists of the sea station and land station. The former consists of an ultrasonic transceiving part of 50 KHz, a hand made 16 bits single board computer (SBC), and a RF MODEM of 9600 bps for data link. The SBC controls the trigger signal to transmit the ultrasonic pulse, maximum detection range, sampling rate in analog to digital converter and data link. The sampling rate of echo data was 80 ${\mu}$s. The later consists of a RF MODEM same as the former one and 486 notebook computer which displays the echogram and saves its raw data. The authors carried out some experiments to confirm the practical use of the telesounder. At results the echogram obtained on the land station is sufficiently good and clear to monitor the behavior of fish school in setnet.

  • PDF