• Title/Summary/Keyword: 펄스길이

Search Result 167, Processing Time 0.024 seconds

Experimental performance analysis on the non-negative matrix factorization-based continuous wave reverberation suppression according to hyperparameters (비음수행렬분해 기반 연속파 잔향 제거 기법의 초매개변숫값에 따른 실험적 성능 분석)

  • Yongon Lee; Seokjin Lee;Kiman Kim;Geunhwan Kim
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.1
    • /
    • pp.32-41
    • /
    • 2023
  • Recently, studies on reverberation suppression using Non-negative Matrix Factorization (NMF) have been actively conducted. The NMF method uses a cost function based on the Kullback-Leibler divergence for optimization. And some constraints are added such as temporal continuity, pulse length, and energy ratio between reverberation and target. The tendency of constraints are controlled by hyperparameters. Therefore, in order to effectively suppress reverberation, hyperparameters need to be optimized. However, related studies are insufficient so far. In this paper, the reverberation suppression performance according to the three hyperparameters of the NMF was analyzed by using sea experimental data. As a result of analysis, when the value of hyperparameters for time continuity and pulse length were high, the energy ratio between the reverberation and the target showed better performance at less than 0.4, but it was confirmed that there was variability depending on the ocean environment. It is expected that the analysis results in this paper will be utilized as a useful guideline for planning precise experiments for optimizing hyperparameters of NMF in the future.

Development of the Automated Ultrasonic Flaw Detection System for HWR Nuclear Fuel Cladding Tubes (중수로형 핵연료 피복관의 자동초음파탐상장치 개발)

  • Choi, M.S.;Yang, M.S.;Suh, K.S.
    • Nuclear Engineering and Technology
    • /
    • v.20 no.3
    • /
    • pp.170-178
    • /
    • 1988
  • An automated ultrasonic flaw detection system was developed for thin-walled and short tubes such as Zircaloy-4 tubes used for cladding heavy-water reactor fuel. The system was based on the two channels immersion pulse-echo technique using 14 MHz shear wave and the specially developed helical scanning technique, in which the tube to be tested is only rotated and the small water tank with spherical focus ultrasonic transducers is translated along the tube length. The optimum angle of incidence of ultrasonic beam was 26 degrees, at which the inside and outside surface defects with the same size and direction could be detected with the same sensitivity. The maximum permissible defects in the Zircaloy-4 tubes, i.e., the longitudinal and circumferential v notches with the length of 0.76mm and 0.38mm, respectively and the depth of 0.04 mm on the inside and outside surface, could be easily detected by the system with the inspection speed of about 1 m/min and the very excellent reproducibility. The ratio of signal to noise was greater than 20 dB for the longitudinal defects and 12 dB for the circumferential defects.

  • PDF

가중 쳐프 신호를 사용한 초음파 고조파 영상 기법

  • 김동열;이종철;권성재;송태경
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.1
    • /
    • pp.61-72
    • /
    • 2002
  • In this parer, a new harmonic imaging technique is Proposed and evaluated experimentally. In the Proposed method. a weighted chirp signal with a hanning window is transmitted. The RF samples obtained on each array element are individually compressed by correlating with the reference signal defined as the 2nd harmonic component($2f_0$) of a transmitted chirp signal generated in a square-law system. The correlator output will then consist of the compressed version of the $2f_0$ component generated in tissue and the crosscorrelation sequence of the fundamental($f_0$) and 2f$_{0}$components. The Proposed method uses the compressed $2f_0$ component to form an image. for which the crosscorrelation term should be suppressed below at least -50dB. The Proposed method has two process, 2f$_{0}$-correlation and $2f_0$-correlation(PI) . $2f_0$-correlation can successfully eliminate the $f_0$ component with a single transmit-receive events and therefore is more efficient than the conventional Pulse inversion method in terms of the frame rate. 2i)-correlation(Pl) Performs pulse compression after applying pulse inversion method for the 2nd harmonic image with high resolution and SNR. Another advantage of the proposed method is that the SNR of 2nd harmonic imaging can be improved without limitation by increasing the duration of the chirp signal. The proposed method was verified through both the computer simulations and actual experiments .ts .

Gas flow pattern through a long round tube of a gas fueling system (I) (기체연료주입계의 긴 원형도관에서 기체 흐름의 유형)

  • IN, S.R.
    • Journal of the Korean Vacuum Society
    • /
    • v.15 no.5
    • /
    • pp.465-474
    • /
    • 2006
  • A gas fueling system composed of a gas reservoir, an on-off valve, and a gas transferring tube, which is the simplest construction for the pre-programmed gas puffing, was simulated by numerically solving the time-dependent one-dimensional gas flow equation. The purpose of the simulation is to establish the relationship between the gas flow pattern (the elapsed time to the maximum flow, the maximum flow rate, the gas pulse duration) and the system parameters (the filling pressure and the volume of the gas reservoir, and the length and the diameter of the gas transferring tube).

Simple Q-switched Waveguide $CO_2$ Laser Using Polygon Mirror (회전 다면셩을 이용한 도파관 $CO_2$ 레이저의 Q-스위칭)

  • 최종운;김용평;강응철;김재기
    • Korean Journal of Optics and Photonics
    • /
    • v.6 no.1
    • /
    • pp.21-25
    • /
    • 1995
  • Q-switched Waveguide $CO_{2}$ laser using polygon mirror were constructed and their output characteristics were measured. Waveguide was made of the beryllium oxide tube of inner diameter of 2 mm, outer diameter of 20 mm, and length of 200 mm. A flat ZnSe output coupler of 80% reflectivity was placed on the 9 mm distance from the end of the waveguide. Convex lens was used to reduce the coupling loss between the polygon mirror and the waveguide. The polygon mirror was located behind of convex lens. With this condition, continuous output of the laser were measured as 1.2 W. In the Q-switched mode. pulse width 120 ns were measured with rotational speed 7,559 RPM. and peak power of up to 250 W. 250 W.

  • PDF

The Q-switched $1.3\mum$ Nd:YAG laser using sautrable absorber Nd:LSB (포화흡수체 Nd:LSB를 이용한 $1.3\mum$ Q-스위칭 Nd:YAG 레이저)

  • 지명훈;이재명;오세용;이영우
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2001.05a
    • /
    • pp.329-332
    • /
    • 2001
  • In this paper, it's shown that the saturable absorber Nd:LSB has a capability as a saturable absorber in Q-switching system. In the passively Q-switched 1.3${\mu}{\textrm}{m}$ Nd:YAG laser with saturable absorber, we theoretically investigated the optimized output mirror, peak power, output power, pulse width and output efficiency. The passively Q-switched Nd:YAG laser with saturable absorber Nd:LSB gives peak power of 30MW and pulse width of 6.23 ps at 30cm resonator length and output mirror reflectivity 98%. Consequently the output energies are 143, 200 and 209 $\mu$J at loss of 2.2%, 2.1% and 1.5%, respectively.

  • PDF

Dual Modulation Driving for Poly-Si TFT Active Matrix OLED Displays (다결정 실리콘 박막 트랜지스터 Active Matrix OLED 디스플레이를 위한 이중 변조 구동)

  • 김재근;정주영
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.41 no.10
    • /
    • pp.17-22
    • /
    • 2004
  • We developed a new ANGLED display driving method which used both amplitude and pulse width modulation. For pulse width modulation, we divided a picture frame time into S sub-frames. For amplitude modulation, we used three OLED luminance(or current) levels which were controlled by TFT's gate voltages. By combining these two modulation methods, we obtained 35(=243) grey levels. And we designed a new data electrode driving circuit block with two shift registers without using DAC's. To verify the feasibility, we simulated the key circuit components by HSpice with TFT parameters extracted from current-voltage characteristics of 6${\mu}{\textrm}{m}$ channel length polysilicon TFT's. From the simulation results, we found that 320${\times}$240, dual scan, 243 grey level AMOLED display can be designed with this method.

Metal Vapor Laser Research II. (금속증기레이저 연구 II)

  • 이재경;정환재;임기건;이형종;정창섭;김진승
    • Korean Journal of Optics and Photonics
    • /
    • v.3 no.3
    • /
    • pp.178-182
    • /
    • 1992
  • An air-cooled discharge-heated copper-vapor laser system with its inter-electrode distance of 45 cm has been developed by utilizing an alumina ceramic plasma tube of 1.6 cm in diameter and 50 cm in lengih. For operating the laser, a dc high voltage power supply with output rating of 6 kV and 500 mA, a resonant charging circuitry consisting partly of an 1.8 H inductor assembly and a 5 nF storage capacitor, and a thyratron driver operating up to 7 kHz have also been developed. The present laser system starts lasing at the tube temperature of about $1350^{\circ}C$ and an maximum average output power of 0.7 W has been obtained at 12 kV, 4.5 kHz. 50 mbar of Ne buffer gas pressure, and at the tube temperature of $1460^{\circ}C$.

  • PDF

Implemeention and performance measurement of a novel in-service supervisory system for WDM transmission link (파장분할다중화방식 전송로의 In-service 감시를 위한 새로운 감시시스템의 구현 및 성능평가)

  • 김필한;윤호성;박남규;서재은;정기태;유기원;이규행
    • Korean Journal of Optics and Photonics
    • /
    • v.12 no.2
    • /
    • pp.129-134
    • /
    • 2001
  • Novel supervisory system for WDM transmission link using conventional optical time domain reflectometry was presented. By modifying the structure of erbuim doped fiber amplifier to support bi-directional transmission at arDR pulse wavelength and launching the optical pulse into transmission link in the opposite direction of data signal propagation to avoid the distortion by cross-gain modulation, it is possible to monitor the WDM link in service. To prove the validity of proposed scheme, the supervision result of 2.5 Gbps $\times$ 8 channel WDM 320 km transmission system in service by arDR was presented. And power penalty due to monitoring was measured as smaller than 0.3 dB. .3 dB.

  • PDF

A Study on the Cyclic Pressure Function in Freeze Drying of Foodstuff (식품의 냉동 건조에서 주기 압력 함수에 대한 연구)

  • Mun, Jae-Choel;Kim, Soo-Ho;Hwang, Kap-Sung;Hong, Song-Sun
    • Applied Chemistry for Engineering
    • /
    • v.8 no.1
    • /
    • pp.1-7
    • /
    • 1997
  • We show that the usage of the cyclic pressure function in the freeze drying is more effective than the drying rate of the constant pressure process. The ultimate object of this process is to reduce energy costs by shortening the drying time. In this work, the concept of cyclic pressure function to decrease the drying time and the effects of the following factors on drying rate are considered ; pulse type, size in amplitude of pressure, size of intermediate time. Temperature for drying has always been maintained constantly at $20^{\circ}C$ and the pulse type could have found to give useful results than the constant pressure by altering chamber pressure from low pressure to high pressure Also, when the amplitude of the pulse is 0.4 torr and the intermediate time is six hour the drying rate was increased considerably.

  • PDF