• Title/Summary/Keyword: 팔걸이

Search Result 23, Processing Time 0.033 seconds

Change in Gait Parameters by Arm Sling Types in Healthy Adults (팔걸이 형태에 따른 정상인의 보행변수 변화)

  • Lee, Ok-Kyoung;An, Duk-Hyun
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.5
    • /
    • pp.267-276
    • /
    • 2010
  • The purpose of this study was to investigate the variations in gait parameters according to arm slings used in healthy adults. Twenty healthy adults (9 males, 11 females) participated in this study and walked at self-selected speeds on a GAITRite-instrumented carpet. They were randomly assigned conditions: without an arm sling, a care sling, a Harris hemi arm sling, a CVA sling, and a Rolyan humeral cuff sling. The following gait parameters were analyzed: the temporo-spatial parameters of gait velocity, swing phase, single support, cadence. In the comparison of parameters in each trial, step length was statistically significantly changed(p=.002). The right step length was significantly decreased in the Harris hemi arm sling and increased in the Rolyan humeral cuff sling when compared with no sling. This study found that several different types arm slings varied gait pattern in healthy adults.

A Study of the Physical Suitability of Chairs Using Conjoint Analysis (Conjoint 분석기법을 활용한 의자의 물리적 적합도 연구)

  • 신미경;박수찬;김진호;최경주
    • Science of Emotion and Sensibility
    • /
    • v.3 no.2
    • /
    • pp.57-65
    • /
    • 2000
  • 컨조인트 분석기법은 Marketing 분야에서 주로 많이 쓰여온 분석 방법으로서 제품의 중요한 속성들을 찾아내어 다양한 종류의 제품들에 대한 고객의 선호도를 분석하는 방법이다. 본 연구에서는 컨조인트 분석기법을 이용하여 의자의 물리적 적합도를 분석, 평가하여 사용자가 적합하다고 느끼는 최적의 의자를 밝히는데 목적을 두었다. 안정성, 여유성, 인체적합성, 안락성등 4개의 적합도 요소를 종속변수로 선택하고 의자 자체의 설계 요소에 해당하는 휴먼인테페이스 요소(HIE) 중 높이 조절 기능, 팔걸이, 등판길이의 3가지 속성을 독립변수로 사용하였다. 분석에 사용된 의자는 각 속성을 특징적으로 대표하는 8개의 의자들로서 구성되었다. 분석의 결과 네 가지의 적합성에 공통성적으로 가장 큰 영향을 주는 속성은 (남자 안정성은 예외) 등판길이로서 남자와 여자 모두 등판길이가 높을 때 안정적이며 안락하고 인체적합하며 여유성이 있다고 느낀다는 결과가 나왔다. 적합도의 네가지 항목 모두에서 공통적으로 등판길이가 높고 팔걸이가 있는 경우에 평가가 높게 나타났으며, 안정성의 경우에는 남·녀 모두 높이조절 기능이 없는 고정형을 더 높게 평가하는 것으로 나타났다.

  • PDF

Development and Analysis of a Walking Game Using Controllers of Armrests and Footboards (Title: Paldokangsan) (팔걸이/발판 컨트롤러를 이용한 걷기게임 '팔도강산' 개발 및 효과성 연구)

  • Kim, Kyung-Sik;Oh, Seong-Suk;Ahn, Jin-Ho;Lee, Sun-Hyung;Lim, Kyung-Choon
    • Journal of Korea Game Society
    • /
    • v.11 no.6
    • /
    • pp.43-52
    • /
    • 2011
  • We have developed a serious game for the game-aided human life and entertainment for the elders with the concept of enjoying scenic beauties in Korea walking in the room using controllers of armrests and footboards with PC. The expected effects of the game are the satisfaction of bodily sensation with cooperation and competition, and also remedy by entertainment such as vital power, maintaining mental functions with the game playing. We have tested 309 elders who were more than 65 years old in Cheonan city community center for the elderly. 76.1% of them answered they were satisfied totally for the game play, average grade for the interest/fun of the game was 4.13 points with full 5 points. 89.4% of them replied they would like to play the game again. We found the intended permissiveness and coenesthesia of the game was appealing to elders.

The Optimal Design for Vehicle Door Trim Armrest Regard to Side Impact Test (측면충돌을 고려한 자동차 도어트림 팔걸이부 최적 설계)

  • Choi, Hae-Seok;Jang, Ik-Kun;Koo, Ja-Keum;Kim, Sun-Min;Kim, Han-Kyoung
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.882-886
    • /
    • 2004
  • A nation have the regulation for a vehicle safety and interested in the side impact of a vehicle. But we spend a lot of money and time for the side impact test. So we must design a vehicle parts regard to the side impact test. This paper describes a new test method for side impact test. We used DFSS(Design For Six Sigma) process for design of door trim armrest. We searched the door trim armrest control factor and made the experiment plan. We researched the optimal design factor and improved the abdomen injury value of the human dummy.

  • PDF

A Study on the Structural Strength of the Rolling Stock Seat Frame (철도차량 시트프레임의 강도 평가 연구)

  • 구정서;조현직
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.12 no.3
    • /
    • pp.130-138
    • /
    • 2004
  • In this paper, the structural strength of a rolling stock seat were numerically evaluated under several design load conditions based on the UIC requirements. The rot]ins stock seat was designed for the high speed train of a Chinese conventional line. To maximize its weight reduction and structural strength, an aluminium alloy, ALDC8-T5, was applied to the base frame, side frames and armrests. The designed seat frame satisfied the strength requirements on inertia loads and fatigue test conditions. However, it couldn't satisfy the requirements on the static test conditions of UIC 566 OR. Therefore, some design modifications were suggested and numerically evaluated whether the static test requirements could be satisfied or not.

Development of Devices for Improving the Reducibility of Patient Positioning on a Breast Board (Breast Board를 이용한 방사선치료에서 환자 위치 재현성 향상 방안에 대한 연구)

  • Huh Soon Nyung;Cho Woong;Park Yang Kyun;Ha Sung Whan
    • Radiation Oncology Journal
    • /
    • v.23 no.2
    • /
    • pp.123-130
    • /
    • 2005
  • Purpose: We wanted to improve the setup reproducibility of breast cancer patients when utilizing a commercially available breast board for radiation therapy. The breast board was modified by using a new head rest and 2 types of board fixation devices. Materials and Methods: A conventional head/neck rest was modified to be positioned in various slots of the breast board, and it was fabricated 1 cm thinner to provide more comfort to a patient when the patient's neck was rotated. This rest improves the uncertainty of the daily setup. Also, the sagging problems at the left and right sides became negligible with the two types of board fixation devices: (1) the stair type, and (2) the arm type. The first device consists of an upper/lower holder with 4 stair-types of grooves and 4 rectangular Inserts. In order to cover the whole range of vertical setup of the breast board, 4 rectangular inserts were needed, and each covered 10 steps. The arm-type fixation device was also fabricated and attached to the breast board, It had two aluminum bars that were fixed by utilizing a lock-type of screw. These devises were evaluated with two volunteers in order to prove the effectiveness of the improved setup accuracy. Results; The developed cranio-caudal fixation device demonstrated that it could reduce the cranio-caudal error by nearly $55\%$ compared to the old device. As for left-and-right inclination, the stair-type and arm-type fixation devices can reduce the relative inclination by nearly $80\%$ and $90\%$, respectively, compared to the breast board without the fixation device. Conclusion: It was verified that the developed devices were effective for positioning the patients and for avoiding inclination of the breast board.

A Study on the Standards of South Korea Type Manual Wheelchair in Accordance with the Human Body Size of Adult (성인인체치수에 따른 한국형수동휠체어 표준규격에 관한 고찰)

  • Kim, S.E.;Song, B.S.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.7 no.2
    • /
    • pp.63-68
    • /
    • 2013
  • Manual wheelchair is one of the most used assistant device in Korea and the size of the wheelchair is defined as KS P ISO 7176-5 which follows the ISO 7176-5 standard size. But the standard often doesn't fit to Korean people because the ISO was enacted by foreigners' body sizes. Actually the result of survey from the Korean Agency for Technology and Standards showd that the designated sizes of height, width, deep of seat except armrest and the height of backrest of a chair in the present KS P ISO 7176-5 are much bigger and the height of armrest is smaller than the sizes investigated by the survey. In case the disabled person has a long wheelchair use time everyday, the posture of user should be uncomfortable because the mismatched size should cause user's pelvis rotations, slouching pose and low stability. Also, inside of knee may touch the wheelchair seat and user can't keep a correct posture. In this paper, the body sizes of Korean disabled person were investigated and the correct wheelchair sizes for Korean people are provided.

  • PDF

Evaluation of The Physical Suitability of Chairs Using Conjoint Analysis (Conjoint Analysis를 이용한 의자의 물리적 적합도 평가)

  • 신미경;김진호;박수찬;최경주;윤지은
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 1999.11a
    • /
    • pp.32-37
    • /
    • 1999
  • 본 연구는 컨조인트 분석기법을 이용하여 의자의 물리적 적합도를 분석, 평가하여 사용자가 선호하는 최적의 의자를 제시하고자 하는데 목적이 있다. 컨조인트 분석기법은 Marketing 분야에서 주로 많이 쓰여온 분석 방법으로서 제품의 중요한 속성들을 찾아내어 다양한 종류의 제품들에 대한 고객의 선호도를 분석하는 방법이다. 이러한 컨조인트 분석기법은 제품개발과 평가의 측면에서 매우 큰 가능성이 있음에도 불구하고 마켓팅 이외의 분야에서는 거의 적용되자 않고 있는 실정이다. 따라서 본 연구에서는 의자의 물리적 적합성 연구에 이 컨조인트 분석을 이용하여 그 적용의 가능성을 알아보고자 하였다. 또한 이러한 적합성 연구에 컨조인트 분석기법이 타당한 분석기법인지 비교하기 위해 분산분석의 기법도 병행하여 실시하였다. 문헌 조사와 전문가 의견 수렴을 통하여 선행연구에서 추출된 의자의 물리적 적합도 요소인 안정성, 여유성, 적합성, 안락성등 4개의 적합도 요소를 채택하여 종속변수로 사용하였다. 또한 의자 자체의 설계 요소에 해당하는 휴먼인터페이스 요소(HIE)는 높이 조절 여부, 팔걸이 유무, Tilting 유무의 3가지 속성을 선택하여 독립변수로 사용하였다. 분석에 사용된 의자는 각 속성을 특징적으로 대표하는 8개의 의자들로서 구성하였고 63명의 피험자를 사용하여 실험하였다. 분석의 결과는 안정성에 가장 큰 영향을 주는 속성은 높이조절(HC)로서 남자와 여자 모두 높이조절 기능이 없을 때 안정성을 느낀다는 결과가 나왔다. 여유성에 영향을 주는 가장 큰 요인은 남자는 높이조절 기능이 있을 때, 여자는 팔걸이가 있을 때 여유성이 있다고 판단하였으며, 인체적합성에 영향을 주는 요인은 남자와 여자 모두 Tilting 기능이, 안락성에 영향을 주는 주요인은 남자는 Tilting 기능이 있을 매, 여자는 높이조절 기능이 있을 때인 것으로 나타났다.감, 강연성, 회복성, 수분특성, 밀도감이었으며, 요인들로 설명되는 누적분산값은 67.18%였다.주관적 평가의 결과와 객관적 평가 결과를 이용해 마직물의 태를 평가하는 산출식을 제시하였다. 태 평가치의 경우 16가지 특성치를 모두 넣는 방법과 stepwise 방법, 또 Kawabatark 사용한 순차적 군 회귀법의 세가지 방법의 회귀식 중 16가지 특성치를 모두 넣는 방법의 결정계수가 가장 높았다.tosterone농도는 107.7$\pm$12.0 pmol/l이었고, 남성의 타액내 농도는 274.2$\pm$22.1 pmol/l이었다. 이상의 결과로 보아 본 연구에서 정립된 EIA 방법은 RIA를 대신하여 소규모의 실험실에서도 활용할 수 있을 것으로 사려된다.또한 상실기 이후 배아에서 합성되며, 발생시기에 따라 그 영향이 다르고 팽창과 부화에 관여하는 것으로 사료된다. 더욱이, 조선의 ${\ulcorner}$구성교육${\lrcorner}$이 조선총독부의 관리하에서 실행되었다는 것을, 당시의 사범학교를 중심으로 한 교육조직을 기술한 문헌에 의해 규명시켰다.nd of letter design which represents -natural objects and was popular at the time of Yukjo Dynasty, and there are some documents of that period left both in Japan and Korea. "Hyojedo" in Korea is supposed to have been influenced by the letter design. Asite- is also considered to have been "Japanese Letter Jobcheso." Therefore, the purpose of

  • PDF

Effect of an Arm Sling on Gait with Hemiparesis (팔걸이가 편마비환자의 보행에 미치는 영향)

  • Song, Geun-Ho;Lee, Hyun-Ok
    • The Journal of Korean Physical Therapy
    • /
    • v.18 no.4
    • /
    • pp.27-40
    • /
    • 2006
  • Purpose: This study was to investigate the effect of an arm sling on gait with hemiparesis. Methods: Fifteen patients(8 male, 7 female) with hemiparesis participated in this study and walked self-selected speed over 10m walkway, randomly without arm sling, with Single strap hemisling and Rolyan humeral cuff sling. It were filmed by 5 video camera and used with 3-dimensional motion analyzer system. The following gait variables were analyzed: temporo-spatial parameters, kinematic parameters. Results: In the comparison of temporo-spatial parameters each trial, walking velocity and single support time on affected side was significantly increased and step length on affected side, step length asymmetry ratio, single support time asymmetry ratio was significantly decreased in the Single strap hemisling and Rolyan humeral cuff sling. In the comparison of kinematic parameters each trial, maximal angle of the hip flexion on affected side was significantly increased in the Single strap hemisling and Rolyan humeral cuff sling and maximal angle of the knee flexion on affected side was significantly increased in the Rolyan humeral cuff sling and maximal angle of the ankle dorsiflexion on affected side was significantly increased in the Single strap hemisling. Conclusion: An arm sling improved walking velocity and decreased asymmetry and increased maximal angle of hip, knee, ankle flexion on affected side with hemiparesis caused by stroke.

  • PDF

The Study of a Newly Designed Sling(MTBSDS) for Hemiplegic Shoulder Subluxation (새로운 팔걸이(MTBSDS)가 편마비환자의 견관절 아탈구에 미치는 효과)

  • Lim, Ho-Yong;Song, Tae-Ho;Yang, Dae-Jung;Park, Seung-Kyu
    • Journal of the Korean Academy of Clinical Electrophysiology
    • /
    • v.2 no.1
    • /
    • pp.71-82
    • /
    • 2004
  • To compare the effectiveness of the hemisling, bobath sling, extension-type sling, and the newly designed Modified Triangular Bobath Sling with Distal Support on a hemiplegic shoulder subluxation. Fourteen hemiplegic patients with shoulder subluxation were evaluated by a simple X-ray with and without the slings and the vertical and horizontal distances on the plain AP views were measurement. The newly designed arm sling was compared in terms of the effects of correction with distal support attached with shoulder saddle sling. The arm sling designed for this study was developed for the purpose of maintaining patients hands in a functional position and performing ROM exercise of the shoulder easily, and prevention or correction to shoulder subluxation. The mean values of the vertical and horizontal distance were compared to determine if there was significant difference of function between the new sling and the conventional slings. The new sling provided the patients with good vertical correction of the subluxation(p<0.05) but did not increase the horizontal distance significantly. These results support the effectiveness of a new sling to decrease subluxation in hemiplegia. Further study on the long term effects or complication of the new sling is recommended.

  • PDF