• Title/Summary/Keyword: 판요소법

Search Result 407, Processing Time 0.029 seconds

Numerical Simulation of Convection-dominated Flow Using SU/PG Scheme (SU/PG 기법을 이용한 이송이 지배적인 흐름 수치모의)

  • Song, Chang Geun;Seo, Il Won
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.3B
    • /
    • pp.175-183
    • /
    • 2012
  • In this study, Galerkin scheme and SU/PG scheme of Petrov-Galerkin family were applied to the shallow water equations and a finite element model for shallow water flow was developed. Numerical simulations were conducted in several flumes with convection-dominated flow condition. Flow simulation of channel with slender structure in the water course revealed that Galerkin and SU/PG schemes showed similar results under very low Fr number and Re number condition. However, when the Fr number increased up to 1.58, Galerkin scheme did not converge while SU/PG scheme produced stable solutions after 5 iterations by Newton-Raphson method. For the transcritical flow simulation in diverging channel, the present model predicted the hydraulic jump accurately in terms of the jump location, the depth slope, and the flow depth after jump, and the numerical results showed good agreements with the hydraulic experiments carried out by Khalifa(1980). In the oblique hydraulic jump simulation, in which convection-dominated supercritical flow (Fr=2.74) evolves, Galerkin scheme blew up just after the first iteration of the initial time step. However, SU/PG scheme captured the boundary of oblique hydraulic jump accurately without numerical oscillation. The maximum errors quantified with exact solutions were less than 0.2% in water depth and velocity calculations, and thereby SU/PG scheme predicted the oblique hydraulic jump phenomena more accurately compared with the previous studies (Levin et al., 2006; Ricchiuto et al., 2007).

TEMPERAMENTAL CHARACTERISTICS OF KOREAN CHILDREN WITH COMMUNICATION DISORDERS (한국 의사 소통 장애 아동의 기질 특성)

  • Joung, Yoo-Sook;Hong, Sung-Do;Kim, E-Yong;Lee, Soo-Geun
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.10 no.1
    • /
    • pp.43-49
    • /
    • 1999
  • Objectives:One of the most common developmental problems is communication disorder in which a child appears normal in every way but who has failed to begin speaking or speaks very little. A few studies have examined the temperamental characteristics of children with communication disorders. This study was to investigate the temperamental characteristics of Korean children with communication disorders. Methods:The parents of 20 Korean children with communication disorders and the parents of 50 normal control children, the age of both groups ranges from 3 to 7, completed Korean version of Parental Temperamental Questionnaire developed by Thomas and Chess. Children with a pervasive developmental disorder, mental retardation, or speech-motor or sensory deficit were excluded. The scores of each temperamental scale of two groups and the diagnostic clusters of two groups were compared. Results:The children with communication disorders were characterized by lower mood scores and higher intensity of reaction scores than normal controls. The two groups showed no significant correlation in terms of the temperamental diagnostic clusters. Conclusion:This findings suggest the existence of a distinct temperamental profile of the children with communication disorders. Early detection of the profile may be of great value for parents in understanding the developmental characteristics of the children with communication disorders and in providing appropriate parenting approaches.

  • PDF

A Study on the Moment Capacity of H-Section Flexural Members with Local Buckling (국부좌굴이 발생하는 H-형강 휨부재의 강도에 관한 연구)

  • Seo, Gun-Ho;Seo, Sang-Jung;Kwon, Young-Bong
    • Journal of Korean Society of Steel Construction
    • /
    • v.23 no.6
    • /
    • pp.647-657
    • /
    • 2011
  • This paper describes the moment capacity of flexural members with local buckling based on a series of FE and experiment results. Thin-walled flexural members undergo local, lateral-torsional, or interactive buckling according to the section geometries and lateral boundary conditions. Flexural members with large width-to-thickness ratios in the flanges or the web may undergo local buckling before lateral-torsional buckling. Local buckling has a negative effect on the flexural strength based on the lateral-torsional buckling of flexural members. This phenomenon should be considered in the estimation of the flexural strength of thin-walled sections. Flexural members with various width-to-thickness ratios in their flanges and web were analyzed. Initial imperfections in the local buckling mode, and residual stresses, were included in the FE analyses. Simple bending moment formulae for flexural members were proposed based on the FE and test results to account for local and lateral-torsional buckling. The proposed bending moment formulae for the thin-walled flexural members in the Direct Strength Method use the empirical strength formula and the grosssection modulus. The ultimate flexural strengths predicted by the proposed moment formulae were compared with the AISC (2005), Eurocode3 (2003), and Korean Highway Bridge Design Specifications (2010). The comparison showed that the proposed bending moment formulae can reasonably predict the ultimate moment capacity of thin-walled flexural members.

Estimation of Fatigue Crack Initiation Life Distribution by Multi-notched Specimen (다응력집중부(多應力集中部)를 가진 판(判)에 의(依)한 피로균열(疲勞龜裂) 발생수명(發生壽命) 분포(分布) 추정(推定))

  • S.W. Kang;D.S. Uom;J.H. Lee
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.29 no.4
    • /
    • pp.234-243
    • /
    • 1992
  • Fatigue crack initiation life has a wide scatter and this makes the fatigue design of structural members difficult. In order to make the fatigue life distribution clear, it is required to prepare a large number of specimens and repeat the fatigue tests under the same loading condition. Such fatigue tests usually take much time and cost. In this study, a fatigue testing method using a multi-notched test specimen for the purpose of estimating the distribution function of fatigue crack initiation life by small number of fatigue tests is used. The purpose of this study is to verify the above fatigue testing method of a multi-notched specimen by using Bayesian reliability analysis, Least square method and Skewness method for the determination of unknown Weibull parameters. The multi-notched specimen is a specimen in which several tens of statistically identical notches are prepared.

  • PDF

Developing LCSI(Library Customer Satisfaction Index) Lite for Public Library (LCSI(Library Customer Satisfaction Index) Lite 공공도서관용의 개발)

  • Oh, Dong-Geun
    • Journal of the Korean Society for Library and Information Science
    • /
    • v.47 no.4
    • /
    • pp.335-361
    • /
    • 2013
  • This study tries to develop the so-called LCSI (Library Customer Satisfaction Index) Lite for public library which can be used easily in the fields as a simplified model. Its conceptual model is developed from the former research about library service quality and customer satisfaction. Based on the analyses on the twenty Delphi-type AHP questionnaires both from the library researchers and from the public library practitioners, and on the analysis and testing of the structural equation model using the data from the more than 800 user questionnaires, it suggests a model which consists of total 15 items - namely 8 items for service quality (2 for personnel, 4 for library resources and services, 2 for facilities and environment), 3 items for customer satisfaction, and 2 items for loyalty. Library Satisfaction Index for public library will be calculated by the sum total of service quality (50%), customer satisfaction (40%), and loyalty (10%).

The Piezoelectric Ultrasonic Cutter Using A Transverse Vibration Mode (횡 진동 모드를 이용한 압전 초음파 커터)

  • Lee, Won-Hee;Kang, Chong-Yun;Kim, Hyun-Jai;Ju, Byeong-Kwon;Yoon, Seok-Jin
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.37-38
    • /
    • 2006
  • 본 연구에서는 압전체의 횡 진동모드를 이용한 압전 초음파 진동자를 설계 분석하였다. 이전의 란쥬반 진동자는 진동을 얻기 위하여, 복수의 원판 또는 사각판 형태의 압전 세라믹을 서로 반대 방향으로 분극하여 마주 보도록 설치한 후 전기적으로 병렬로 연결하고 상단 및 하단에 금속부을 부착하여 전체를 볼트로 조인 복잡한 구조와 큰 출력 파워를 갚는 반면, 본 연구에서는 판상형의 압전소자와 일체형 금속진동체를 이용하여 기계적 출력 파워 조절이 용이한 구조의 압전 진동자를 고안하여, 압전진동자의 횡 진동 모드를 이용함으로써 신뢰성과 정확도가 높고 진동효율이 최대가 되도록 설계하였다. 설계 개발된 압전 진동자는 진동의 크기 조절이 용이하여 일반 진동자 뿐 만 아니라, 외과 및 안과 수술에 있어서 인체조직이나 각막상피의 활성화를 유지한 상태에서 안전하게 절개 및 분리 시술용 진동자로 사용 할 수 있는 이점이있다. 압전 진동자는 유한요소법 시뮬레이션 프로그램 (ATILA 5.2.4)을 이용하여 설계를 하였으며 압전소자의 두께는 각각 0.2 mm, 0.5 mm로 제작하여 시뮬레이션 결과와 제작된 샘플의 특성을 비교하였고, 변위측정은 칼날을 결합 한 상태에서 공진 주파수대역 부근 주파수별로 측정 비교하였다.

  • PDF

Sound Absorption Capability and Anatomical Features of Highly Sound Absorptive Wood (고흡음성 목재의 흡음성능과 구조적 특징)

  • Kang, Chun-Won;Kang, Wook;Kim, Gwang-Chul
    • Journal of the Korean Wood Science and Technology
    • /
    • v.38 no.4
    • /
    • pp.292-297
    • /
    • 2010
  • Sound absorption capability and anatomical features of kagikazura (Uncaria rhynchophylla) and larch (lalix kaemferi) wood were estimated. Sound absorption coefficients had been measured by the two microphone transfer function method and anatomical features of kagikazura wood examined by SEM observation. The sound absorption coefficients of Uncaria rhynchophylla was higher than lalix kaemferi. Especially, in the frequency range of 1 to 4KHz, sound absorption coefficients of kagikazura was about 2~3 times higher than those of lalix kaemferi. Abundant and big vessel observed on the cross sectional surface of kagikazura wood and simple perforation plate observed on the longitudinal surface. It was surmised that the abundant big vessel element and simple perforation plate behaved as a sound absorbing pore.

Lateral Wall Movements and Apparent Earth Pressures for In-situ Walls during Deep Excavations in Multi-Layered Grounds with Rocks (암반을 포함한 다층토 지반에서의 깊은 굴착시 흙막이벽체의 수평변위 및 겉보기토압)

  • 유충식;김연정
    • Journal of the Korean Geotechnical Society
    • /
    • v.16 no.4
    • /
    • pp.43-50
    • /
    • 2000
  • This paper presents the measured performance of in-situ walls using the measured data collected from various deep excavation sites in urban area. A variety of in-situ wall systems from 57 sites were considered, including H-pile walls, soil cement walls, cast-in-place pile walls, and diaphram walls. The examination included lateral wall movements as well as apparent earth pressure distributions. The measured data were thoroughly analyzed to investigate the effects of various components of in-situ wall system, such as types of wall and supporting system, on the lateral wall movement as well as on the apparent earth pressure distribution. The results wee then compared with the current design/analysis methods, and information is presented in chart formes to provide tools that can be used for design and analysis. Using the measured data, a semi-empirical equation for predicting deep excavation induced maximum lateral wall movement is suggested.

  • PDF

Analysis of the complaints and policy of the Ministry of Employment and Labor using the R program (R을 이용한 고용노동부 민원·정책 연관분석)

  • Sung, Bo-Kyoung;You, Yen-Yoo
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.7
    • /
    • pp.41-46
    • /
    • 2018
  • This study is based on the opinions of the Ministry of Employment and Labor and the Policy Bulletin of the National Intelligence Service (http://www.people.go.kr) The data were visualized, frequency analysis and correlation analysis using the R program Big Data method, and the analysis was conducted by analyzing the public opinion on civil affairs and policies such as industrial relations, industrial safety, wage policy, The results of this study are as follows: First, disagreement of wage concept and labor - management conflict were found as complaints factor due to complex wage structure in Korea and lack of awareness among labor and management Second, And there are various complaints caused by the economic panic of the workers etc. Third, in the absence of safety awareness of small business sites An industrial disaster is constantly occurring, and institutional support for work-family connection is lacking.

Design of Six-Component F/T Sensor with Flexible Fixed Ends (유연한 고정단을 가진 6축 F/T 센서의 설계)

  • Lee, Bong-Hee;Joo, Jin-Won
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.6
    • /
    • pp.771-780
    • /
    • 2010
  • This paper describes the design process of a six-component force/torque (F/T) sensor. The new six-component F/T sensor having leaf spring ends has been developed using a cross beam structure as the basic sensing element. Fundamental strain analysis of both ends fixed beam having a leaf spring structure is performed by finite element analysis. In order to obtain similar output sensing strains from the six component loads and minimize coupling strains, the optimal location of strain gages is determined and the strain gages are connected so that the bridge circuits with four strain gages would be balanced. Using leaf spring ends instead of rigid fixed ends, remarkable increment in output sensing strain can be achieved for two component forces. Several modifications in design result in a similar sensing strain of approximately $400\;{\mu}m/m$ for the six-component forces and moments, and a reduced coupling strain of $0\;{\mu}m/m$ between the forces and moments.