• Title/Summary/Keyword: 판막

Search Result 929, Processing Time 0.02 seconds

Histologic Changes of the Immunologically Untreated Xenogenic Valved Conduit (면역학적 처리 없는 이종 심장 판막 도관의 조직학적 변화에 관한 연구)

  • Sung, Ki-Ick;Seo, Jeong-Wook;Kim, Won-Gon
    • Journal of Chest Surgery
    • /
    • v.40 no.1 s.270
    • /
    • pp.1-7
    • /
    • 2007
  • Backgound: It has been shown that the endothelium of cardiac valves and adjacent great vessels have a reduced immune reaction compared to other vessels. We investigated the clinical feasibility of using immunologically untreated xenogenic valves, in a pig-to-goat pulmonary valve conduit implantation model. Material and Method: Porcine pulmonary valve conduits were prepared without specific immunologic treatment and implanted into the right ventricular outflow tract of goats while undergoing cardiopulmonary bypass. Two goats each were assigned to the following observation time intervals: one day, one week, three months, six months and twelve months. Echo-cardiographic examinations were performed prior to sacrifice of the goat to evaluate pulmonary valve function. After the xenograft specimens were retrieved, histological changes were evaluated microscopically. Result: Ten of the twelve animals survived the predetermined observation time intervals. Aneurysmal dilatations, of the anterior wall of the implanted pulmonary artery, were observed at each of three and twelve month-survival animals. A variable degree of pulmonary valve regurgitation was observed on echocardiography. However, valve stenosis, thrombotic occlusion and vegetation were not seen. Microscopically, the nuclei of the donor tissue disappeared as a result of pyknosis and karyolysis; however the three components of the implanted xenografts (the pulmonary artery, the valve and the infundibulum) were gradually replaced by host cells over time, while maintaining their structural integrity. Conclusion: Immunologically untreated xenogenic pulmonary valve conduits were replaced by host cells with few observed clinical problems in a pig to goat pulmonary valve implantation model. Therefore, they might be an alternative bioprosthesis option.

Infective Endocarditis Involving Aortic Valve, Mitral Valve, Tricuspid Valve, and luterventricular Septum -A Case Report (대동맥판막, 승모판막, 삼첨판막과 심실중격을 침범한 심내막염 -1예 보고-)

  • 박종빈;서동만
    • Journal of Chest Surgery
    • /
    • v.30 no.2
    • /
    • pp.200-204
    • /
    • 1997
  • This is a report of a successful management of a patient with infective endocarditis involving native aortic valve, mitral valve, tricuspid valve, and Interventric lar septum. A 16 year-old patient who underwent VSD patch closure, and aortic valvuloplasty at the age of 1 1 years showed Intractable congestive heart failure during antibiotics treatment for infective endocarditis. Operative findings revealed that there were large defect along the previous patch, aortic regurgitation with multiple perforations and vegetations, mitral regurgitation with vegetation, aortic paraannular abscess, interventricular myocardial abscess, and tricuspid regurgitation with perforations and vegetations. We reconstructed the interventricular defect with Dacron patch extending to the aortic valve annulus after radical debridement of all infected or devitalized tissues, and could implant aortic valve by anchoring to the reconstructed Dacron patch. Mitral valve was replaced and tricuspid valve was repaired with patient's own pericardium. The patient was discharged after antibiotics treatment for 6 weeks and in good condition without any sequelae for 12 months.

  • PDF

Fate of Regurgitation of Left Atrioventricular Valve Following Repair of Atrioventricular Septal Defect (완전 방실중격결손증의 수술적 교정 후 잔존 좌측 방실판막부전에 대한 장기적 임상 경과 관찰)

  • 김시호;박한기;장병철;조범구;방정희;박영환
    • Journal of Chest Surgery
    • /
    • v.36 no.12
    • /
    • pp.961-969
    • /
    • 2003
  • The purpose of this study was to evaluate the fate of left atrioventricular valve regurgitation(LAVVR) following repair of complete atrioventricular septal defects (AVSDs). Material and Method: Between July 1984 and March 2002, repair of complete AV defects were performed in 77 patients. Mean age at surgery was 30.23$\pm$69.11 months (range 1 to 456). Echocardiograms of all survivors after isolated AVSDs correction were reviewed. LAVVR were evaluated with color doppler echocardiography in 64 survival periodically. On each study, LAVVR severity was graded on a 1 to 4 scale, based upon the size of the regurgitated jet. Result: Mild deterioration of LAVV function was fairly common. LAVVR severity increased by >1 grade in 19 patients (30.2%) during the course of the study. However, the deterioration in LAVVR function occurred primarily between 12 and 24 months postoperatively. After the initial 24 postoperative months, LAVVR worsened on only 8 occasions and in each instance worsened by only 1 grade. Deterioration more than 3+ LAVVR occurred in only 3 patients. And deterioration to 4+ LAVVR was not observed after the initial 24 postoperative months but one. Survival curve analysis predicted a 88.2% of ten-year freedom rate from development of 4+ LAVVR after initial operation of complete AVSDs. Conclusion: Postoperative LAVVR remains fairly stable following AVSDs repair, Serious deterioration is rare after 24 postoperative months, especially after the initial 48 postoperative months. But serial follow-up study with echocariogram was need till 24 postoperative months after repair of complete AVSDs.

Biaxial Strain Analysis of Various Fixation Models in Porcine Aortic and Pulmonary Valves (돼지 대동맥 판막과 폐동맥 판막의 고정 방법에 따른 양방향 압력-신장도의 비교분석)

  • Cho, Sung-Kyu;Kim, Yong-Jin;Kim, Soo-Hwan;Choi, Seung-Hwa
    • Journal of Chest Surgery
    • /
    • v.42 no.5
    • /
    • pp.566-575
    • /
    • 2009
  • Background: The function of a bioprosthetic heart valve is determined largely by the material properties of the valve cusps. The uniaxial tensile test has been studied extensively. This type of testing, however, does not replicate the natural biaxial loading condition. The objective of the present study was to investigate the regional variability of the biaxial strain versus pressure relationship based on the types of fixation liquid models. Material and Method: Porcine aortic valves and pulmonary valves were assigned to three groups: the untreated fresh group, the fixed with glutaraldehyde (GA) group, and the glutaraldehyde with solvent (e.g., ethanol) group. For each group we measured the radial and circumferential stretch characteristics of the valve as a function of pressure change. Result: Radial direction elasticity of porcine aortic and pulmonary valves were better than circumferential direction elasticity in fresh, GA fixed and GA+solvent fixed groups (p=0.00). Radial and circumferential direction elasticity of pulmonary valves were better than aortic valves in GA fixed, and GA+solvent fixed groups (p=0.00). Radial and circumferential direction elasticity of aortic valves were decreased after GA and GA+solvent fixation(p=0.00), except for circumferential elasticity of GA+solvent fixed valves (p=0.785). The radial (p=0.137) and circumferential (p=0.785) direction of elasticity of aortic valves were not significantly different between GA fixed. and GA+solvent fixed groups. Radial (p=0.910) and circumferential (p=0.718) direction of elasticity of pulmonary valve also showed no significant difference between GA fixed and GA+solvent fixed groups. Conclusion: When fixing porcine valves with GA, adding a solvent does not cause a loss of mechanical properties, but, does not improve elasticity either. Radial direction elasticity of porcine aortic and pulmonary valves was better than circumferential direction elasticity.

Outcomes of Combined Mitral Valve Repair and Aortic Valve Replacement (대동맥판막 치환술과 동반시행한 승모판막 성형술 결과)

  • Baek, Man-Jong;Na, Chan-Young;Oh, Sam-Se;Kim, Woong-Han;Whang, Sung-Wook;Lee, Cheol;Chang, Yun-Hee;Jo, Won-Min;Kim, Jae-Hyun;Seo, Hong-Ju;Kim, Soo-Cheol;Lim, Cheong;Kim, Wook-Sung;Lee, Young-Tak;Choi, Hyun-Seok;Moon, Hyun-Soo;Park, Young-Kwan;Kim, Chong-Whan
    • Journal of Chest Surgery
    • /
    • v.36 no.7
    • /
    • pp.463-471
    • /
    • 2003
  • The long-term results of combined mitral valve repair and aortic valve replacement (AVR) have not been well evaluated. This study was performed to investigate the early and long-term results of mitral valve repair with AVR. Material and Method: We retrospectively reviewed 45 patients who underwent mitral valve repair and AVR between September 1990 and April 2002. The average age was 47 years: 28 were men and 17 women. Twelve patients had atrial fibrillation and three had a previous cardiac operation. The mitral valve disease consisted of pure insufficiency (MR) in 34 patients, mitral stenosis (MS) in 3, and mixed lesion in 8. Mitral valve disease was due to rheumatic origin in 24 patients, degenerative in 11, annular dilatation in 8, and ischemia or endocarditis in 2. The functional anatomy of mitral valve was annular dilatation in 31 patients, chordal elongation in 19, leaflet thickening in 19, commissural fusion in 13, chordal fusion in 10, chordal rupture in 6, and so on. Aortic prostheses used included mechanical valve in 32 patients, tissue valve in 12, and pulmonary autograft in one. The techniques of mitral valve repair included annuloplasty in 32 patients and various valvuloplasty of 54 techniques in 29 patients. Total cardiopulmonary bypass and aortic cross clamp time were 204$\pm$62 minute and 153$\pm$57 minutes, respectively. Result: Early death was in one patient due to low output syndrome (2.2%). After follow up of 57$\pm$37 months, late death was in one patient and the actuarial survival at 10 years was 96$\pm$4%. Recurrent MR developed grade II or III in 11 patients and moderate MS in 3. Three patients required reoperation for valve-related complications. The actuarial freedom from recurrent MR, MS, and reoperation were 64$\pm$11%, 86$\pm$8%, and 89$\pm$7% respectively. Conclusion: Combined mitral valve repair with AVR offers good early and long-term survival, and adequate techniques and selection of indication of mitral valve repair, especially in rheumatic disease, are prerequisites for better long-term results.

Early Clinical Outcome and Doppley Echocardiographic Data after Cardiac Valve Replacement with the ATS prosthesis (ATS 인공 판막의 조기 임상성적 및 도플러 심에코 검사 소견)

  • 박계현;박승우
    • Journal of Chest Surgery
    • /
    • v.30 no.7
    • /
    • pp.663-669
    • /
    • 1997
  • This is a report on the clinical outcome and hemodynamic profile of the ATSwcardiac valve prosthesis, which is a recently introduced pyrolytic carbon bileaflet prosthesis. We retrospectively reviewed the early outcome of 100 consecutive patients who underwent isolated cardiac valve replacement with the ATS(w prosthesis from October 1994 through June 1996 at our hospital. All patients were evaluated with Doppler echocardiography before discharge from the hospital. The mean age of the patients was 48.6 years(range: 2 to 74). A tota of 124 prosthesis were implanted; 71 mitral, 46 aortic, and 7 tricuspid. The two most frequently used sizes were 27 mm(40.8%) and 29 mm(35.2%) in the mitral position, and 23 mm(30.4%) and 21 mm(28.3%) in the aortic position. There was no early or late death. The total follow-up period was 950 patient-months with 99% follow-up rate. Serious late morbidity occurred in three patients; reoperation in two patients for late rupture of Sinus of Valsava in one and for endocarditis with prosthetic dehiscence in the other, and intracranial hemorrhage due to hypertension in one patient. There has been no thromboembolic complication or structural valval deterioration. In the mitral position, the average values of peak and mean transprosthetic pressure gradients and valve area calculated from pressure half time were 6.9$\pm$2.8 mmHg, 2.6$\pm$ 1.5 mmHg, and 2.7 $\pm$0.8 cm2 respectively. In the aortic position, the peak and mean pressure gradients'were 26.4 $\pm$ 15.9 mmHg and 14.2 $\pm$ 7.9 mmHg. For the mitra prostheses larger than 25-mm size, there was no significant difference among prosthetic sizes in terms of transprosthetic gradients, whereas there was a significant negative correlation between the prosthesis size and the transprosthetic gradients for the aortic valves. The peak and mean Pressere pradients were 52.2 $\pm$ 17.6 tmHg and 26.9$\pm$ 7.4 mmHg across the 19-mm aortic Prostheses, and 27.1 $\pm$ 11.9 mmHg and 13.3$\pm$6.6 mmHg across the 21-mm size. Above results can lead to the conclusion that the early clinical outcome of the ATS valve prosthesis is quite satisfactory, And the hemodynamic characteristics are comparable, if not better, with other bileaflet prostheses.

  • PDF

Mid-term Results of the Congenital Bicuspid Aortic Valve Repair (선천성 이엽성 대동맥판막질환에 대한 판막성형술의 중기 성적)

  • 조광리;곽재건;안혁
    • Journal of Chest Surgery
    • /
    • v.37 no.10
    • /
    • pp.833-838
    • /
    • 2004
  • Background: Despite the excellent early results after the repair of congenital bicuspid aortic valve (BAV) disease, the mid-term durability of the repaired valve has still controversies. Material and Method: To evaluate the mid-term results of BAV repair, retrospective review of medical records and echocardiographic data were done. Between 1994 and 2003, twenty-two patients underwent reparative procedure for either regurgitant or stenotic congenital bicuspid aortic valve (BAV). Result: Mean age was $41\pm14$ years with male predominance (Male=17, Female=5). The pathophysiologies of the BAV were regurgitation-dominant in 20 (91%) and stenosis-dominant in 2 (9%) cases. Various repair techniques were used for raphe, prolapsed leaflet, thickened leaflet, and commissures; 1) release of raphe in 19 (86%), 2) wedge resection and primary repair in 11 (50%), pericardial patch reinforcement after plication of the leaflet in 6 (27%), and plication of the leaflet in 3 (14%), 3) slicing of thickened leaflet was used in 12 (55%) cases, 4) commissuroplasty in 8 (36%), and commissurotomy in 6 (27%) cases. There was no in-hospital mortality. During the mean follow-up of $38\pm17$ months, one patient underwent aortic valve replacement after developing acute severe regurgitation from dehiscence of the suture on postoperative 2 months. New York Heart Association functional class was improved from $1.9\pm0.6$ to $1.2\pm0.5$ (p<0.01). Left ventricular end-systolic and diastolic dimension (LVESD/LVEDD) were also improved from $45\pm9$ and $67\pm10$ to $37\pm10$ and $56\pm10,$ respectively (p<0.01). The grade of aortic regurgitation (AR) was improved from preoperative $(3.1\pm1.2)$ to post-bypass $(0.9\pm0.7).$ However, the grade at last follow-up $(1.7\pm1.1)$ was deteriorated during the follow-up period (p<0.01). Freedom from grade III and more AR at one, three, and four year were 89.7%, 89.7%, and 39.9% respectively. Conclusion: Midterm clinical result of the BAV repair was favorable. But, the durability of the repaired valve was not satisfactory.

Tissue Failure of the Standard-Profile lonescu-Shiley Pericardial Valve in Mitral Position (승모판에서의 표준형 이오네스류 판막의 조직실패)

  • 김종환
    • Journal of Chest Surgery
    • /
    • v.29 no.10
    • /
    • pp.1111-1117
    • /
    • 1996
  • Structural deterioration of the bioprosthetic xenograft valves due to primary tissue failure occurs in two modes: from fatigue lesions with tear and wear with or without calcification and from calcification with obstruction. Two groups of consecutive 56 patients with the Hancock porcine ortic valve(HM) and of 1 13 patients with the standard-profile onescu-Shiley bovine pericardial valve(ISM) explanted from mitral position at the time of re-replacement surgery for primary tissue failure at Seoul national University Hospital until 1994, were studied for clinical and pathological features. Their ages at primary implant were 31.9 $\pm$9.2 years In HM and 30.4$\pm$ 12.5 years in ISM. Hemodrnamic dysfunction of the failed mitral bloprostheses were predominantly insufficiency in HM(64.3%) and stenosis in ISM(51.3%)(p<0.001). Pathologic findings of the explanted mitral valves reflected these hemodynamic changes, revealing failure more often from tissue damage(tears and wears) in HM and more often from calcification in ISM(p< 0.001). Explant period(from primary implant to explant) was relatively short in ISM(8.7$\pm$2.6years), compared with the one in HM(10.4 $\pm$2.6 years)(p<0.001). In conclusion, both the Hancock and the lonescu-shiley valves would fail from calcification as well as issue damage. However, while the Hancock porcine valves in mitral position failed more frequently from tissue failure and insufficiency, the standard-profile lonescu-Shiley pericardial valves did from calcification and stenosis, especially in young pAtients . Although the possibility of less occurrence of valve failure from mechanical reasons may be expected with newer generation bloprostheses, it does not seem to Improve durability significantly unless further refinement in antimineralization is achieved. Therefore, clinical use of the glutaraldehyde-treated bioprosthetic valves is, at present, limited to the patients of advanced age groups.

  • PDF

Changes of Microembolic Signals after Heart Valve Surgery (심장 판막 수술 후 미세색전의 변화)

  • 조수진;이은일;백만종;오삼세;나찬영
    • Journal of Chest Surgery
    • /
    • v.36 no.5
    • /
    • pp.316-320
    • /
    • 2003
  • Background: The detection of circulating microemboli by transcranial Doppler ultrasonography (TCD) has the potential to select the patients with high risk for future symptomatic brain embolism. We prospectively evaluated the positive rate and the frequency of microembolic signals (MES) before and after the heart valve surgery (HVS). Material and Method: Fifty in-patients with heart valve disease were enrolled in this study. Patients with history of previous stroke or heart valve surgery were excluded. Two unilateral TCD monitoring sessions were peformed from middle cerebral artery for 1-hour, before and after HVS. Result: Mechanical Heart valves were implanted in 28 patients, tissue valves were implanted in 10 patients, and remaining 12 patients received mitral valve repair. Positive rate of MES was significantly increased after HVS (50%), compared to that of before HVS (8%, p=0.00). There was no relation between MES after HVS and intensity of anticoagulation, cardiac rhythm, patients' age, and history of hypertension. The positive rate of MES after implantation of mechanical heart valve (71.4%) was significantly higher than those after implantation of tissue valve or mitral valve plasty (p=0.002). Conclusion: Positive rate of MES was increased significantly after the implantation of HVS. The changes of MES in those with mechanical prosthesis may be related to the increased risk or embolism after Hvs.

Aortic Stenosis in Systemic Lupus Erythematosus Syndrome (전신성 흥반성 낭창에 동반된 대동맥 판막 협착증의 수술 1에)

  • 최주원;김우식;고행일;강윤경;김용인
    • Journal of Chest Surgery
    • /
    • v.37 no.7
    • /
    • pp.613-616
    • /
    • 2004
  • Systemic lupus erythemotosus (SLE) is an autoimmune disorder with dermal, renal, and cardiac manifestations. It frequently has cardiovascular complications such as pericarditis, myocarditis, and valvular heart diseases. Valvular heart diseases in SLE comes mainly in the form of mitral or aortic insufficiencies. Report of aortic stenosis is extremely rare. Surgical treatments of valvular heart disease in SLE are not done frequently because of complications in other organs. Aortic stenosis developed in a 59 year-old woman with SLE, and aortic valve replacement was done successfully.