• Title/Summary/Keyword: 판독장치

Search Result 78, Processing Time 0.03 seconds

Traffic Lights Detection Based on Visual Attention and Spot-Lights Regions Detection (시각적 주의 및 Spot-Lights 영역 검출 기반의 교통신호등 검출 방안)

  • Kim, JongBae
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.6
    • /
    • pp.132-142
    • /
    • 2014
  • In this paper, we propose a traffic lights detection method using visual attention and spot-lights detection. To detect traffic lights in city streets at day and night time, the proposed method is used the structural form of a traffic lights such as colors, intensity, shape, textures. In general, traffic lights are installed at a position to increase the visibility of the drivers. The proposed method detects the candidate traffic lights regions using the top-down visual saliency model and spot-lights detect models. The visual saliency and spot-lights regions are positions of its difference from the neighboring locations in multiple features and multiple scales. For detecting traffic lights, by not using a color thresholding method, the proposed method can be applied to urban environments of variety changes in illumination and night times.

The Implementation of a PC GUI for a Multimedia Tele-Medical System based on ATM / B-ISDN (ATM/B-ISDN 통신망 기반의 멀티미디어 원격의료 정보시스템을 위한 PC용 GUI 구현)

  • 정연기;김영탁
    • Journal of Korea Multimedia Society
    • /
    • v.1 no.1
    • /
    • pp.45-55
    • /
    • 1998
  • In the tele-medical system, the broadband network for multimedia telecommunication and the multimedia terminal equipment for the remote access of the tele-medical information are essential. Especially, the tele-medical terminal equipment should provide the multimedia GUI environment in order to support the similar medical process by the tele-medical system. In this paper, we present a multimedia GUI (Graphic User Interface) for a Multimedia Tele-Medical System (TeleMedi_GUI) based on ATM/B-ISDN. In the tele-medical system, one workstation is used for the multimedia data server that is supporting multiple client terminals that are connected by the ATM network. The client terminals are based on Multimedia Personal Computers, and provide the remote access environment of the tele-medical database. We also developed the remote access protocols among the clients and the server to access multimedia medical information of the multimedia server. With using the TeleMedi_GUI, the doctors can examine and treat patients efficiently, using image data like X-ray/CT and voice data such as the S-ray diagnosis. The result of this paper can be applied to the following areas: 1) the implementation of the advanced medical service system interconnecting the small-scale health center and general hospitals, 2) the development of a fully computerized medical information system within the hospital.

  • PDF

Efficient Pseudo Random Functions for the e-seal Protection Protocol (e-seal 보안 프로토콜을 위한 효율적인 Pseudo Random Function)

  • Min Jung-Ki;Kang Seok-Hun;Chung Sang-Hwa;Kim Dong-Kyue
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2006.06c
    • /
    • pp.274-276
    • /
    • 2006
  • e-seal은 RFID(Radio Frequency IDentification) 기술을 사용하여 원격에서 자동으로 봉인상태를 확인할 수 있는 컨테이너 봉인 장치를 말한다. RFID의 특징상 반도체 칩에 기록된 정보를 제 삼자가 쉽게 판독 및 변조할 수 있다는 취약점으로 인하여 활성화되지 못하고 있는 실정이다. ISO에서는 RFID의 취약점을 보안하기 위한 표준작업(ISO 18185)을 진행 중이다. 이 중, ISO 18185-4는 e-seal에 저장되는 자료나 리더와의 RF통신에서 데이터 보호를 위한 표준이다. 이와 관련된 연구로는 인증 프로토콜과 ISO 18185-4를 위한 보고서로 제출된 보안 프로토콜이 있다. 제안된 e-seal 보안 프로토콜을 적용하기 위해서는 e-seal과 리더 간의 데이터를 암/복호화할 키가 필요하지만, 키 서버를 통해 전달받은 마스터 키를 데이터 암/복호화 키로 바로 사용하는 것은 보안 상의 문제점을 야기할 수 있기 때문에 PRF(Pseudo Random Function)을 이용하여 마스터 키로부터 MTK(Mutual Transient Key)를 유도하고, MTK를 암/복호화 키로 사용해야 한다. 기존의 PRF는 일방향 해시 함수(MD5, SHA 등)를 기반으로 하는 HMAC[2. 3]을 일반적으로 사용하였다. 그러나 일방향 해시 함수는 e-seal과 같은 제한된 자원을 갖는 환경에 적합하지 않다. 따라서, 본 논문에서는 e-seal 보안 프로토콜을 위한 효율적인 PRF을 제안한다. 기존의 일방향 해시 함수 기반이 아닌 블록 암호화 알고리즘을 기반으로 하는 MAC을 이용하여 PRF을 보다 효율적으로 구현하였고, 블록 암호화 알고리즘은 AES를 선택 합성체 $GF((2^4)^2)$을 통해 하드웨어 모듈을 최적화 하였다. AES를 기반으로 하는 MAC은 HMAC에 비해 면적 및 처리율에서 뛰어난 결과를 보여주었다.<0.01).이상의 연구 결과, cook-chill생산 시 녹차 추출물의 첨가가 미생물적 품질유지에 효과가 있다고 사료되는 바 본 연구결과를 기초로 급식소에서 음식 생산 시 녹차 추출물 및 천연 항균성 물질 첨가에 따른 미생물적 품질 및 관능적 품질검사를 통한 레시피 개발에 관한 지속적인 연구가 수행되어야 하겠다.다.다리다보니 점심시간을 활용할 수 없게 되는 문제점에 대한 재검토가 필요하다. 따라서 차후 학교급식의 안전성 확보를 위한 급식환경 개선의 일환으로 식당공간 확보 시 신속한 시간 내에 급식이 가능하도록 넓은 공간과 쾌적한 환경의 식당 조성에 대해 관심을 기울여야 할 것으로 사료된다. 이상 여부를 반영하는 임상증상의 빈도가 높은 청소년기 남녀 중학생의 경우 아침과 저녁의 결식빈도 및 외식과 간식의 빈도가 높았고, 아침식사의 질과 체형만족도가 낮은 것으로 나타나 청소년의 건강과 식습관 및 체형만족도가 상호 관련성이 높은 것으로 나타났다. 따라서 본 연구 결과는 성장기 청소년의 건강 유지를 위하여 바람직한 식습관의 중요성을 재인식할 수 있었으며, 올바른 식습관 확립을 위한 영양교육의 중요성이 재확인되었다.경제적일 것으로 판단된다.er 90 % of good relative dynamic modulus of elasticity due to fineness of formation caused by the increase of the unit powder content and the improvement of flowability, without regard to the replacement of crushed stone fines. Therefore, it can be said that the usage of crushed stone fines can control the strength of super flowing concrete by replacement and re

  • PDF

Actual condition on accuracy control of mammography equipment in Kyeongsangbuk-do (경상북도 유방촬영장비의 정도관리에 대한 실태조사)

  • Kim, Sang-Jin;Ji, Tae-Jeong
    • Journal of radiological science and technology
    • /
    • v.29 no.1
    • /
    • pp.29-37
    • /
    • 2006
  • The breast cancer has the highest occurrence rate among the female cancers, and as the living style changes, the occurrence is increasing gradually. For the breast cancer test among women, who comprises up to 50% of the total population, the mammography is mainly used as the screening test, and the accuracy control is the most important aspect of the testing. Therefore this research divided the northern part of Kyeongsangbuk-do into 4 regions and investigated the accordance ratio of examination field and light examination field, the total focus using the optical density and compression rate, and the overall maintenance of mammography within the regions. The equipments of 11 hospitals were investigated, and the 7 hospitals passed the standard level of the accordance ratio of examination field. 6 hospitals passed the standard optical density, and 7 hospitals had the passing performance in the compression rate. Fibers, group of specks, and masses within the Mammographic Accreditation Phantom scored 10, being within the standard range. However, only 3 hospitals were equipped with private development processor and illumination. The result reflects the fact that the image quality of breast is not correctly being maintained. Moreover, only 27.27% satisfied all the three categories of compression fitting, accordance ratio of examination field, and phantom image evaluation at the same time. The accuracy control must be maintained more precisely for the accurate diagnosis of breast cancer.

  • PDF

A Measurement of Exposure Dose for Patient Transporter (환자 이송원의 피폭선량 측정)

  • Song, Chaerim;Lee, Wanghui;Ahn, Sungmin
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.3
    • /
    • pp.433-438
    • /
    • 2019
  • The medical institutions use radiation generating devices and radioactive isotopes to diagnose and treat patients. The patient transporter performs work in an environment that is more likely to be exposed to radiation when compared with the general public, such as inevitably entering the radiation management area for patient transfer, or transferring the isotope-administered patient at a short distance. For this reason, we conducted a study to determine the degree of exposure of the patient transporter. The 12 patient transporters working at Incheon A General Hospital are eligible. From April 1, 2019 to April 30, 2019, the dosimeter was used in the chest for one month and the accumulated dose was measured. The dosimeter used was a Optically Stimulated Luminescence Dosimetry (OSLD) and the dose reading was OSLD Microstar Reading System. As a result of cumulative dose measurement for one month, the average of the deep dose was 0.13 mSv and the surface dose was 0.13 mSv, and the cumulative dose for one month was multiplied by 12 to estimate the cumulative dose expectation As a result, the average of the deep dose and the surface dose were 1.52 mSv and 1.51 mSv, respectively. It is necessary to classify the patient transporter as a frequent visitor in order to measure and manage the exposure dose, increase the knowledge of protection against radiation through education and training, and prevent radiation trouble through medical examination.

Diagnosis of Location and Size of Lesions using Chest X-ray Image (X-선 영상을 이용한 암의 위치 및 크기 진단)

  • Jung-Min, Son;Byung-Ju, Ahn
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.1
    • /
    • pp.167-173
    • /
    • 2023
  • X-ray general radiography is the simplest and most important one to get a lot of information. Nevertheless, current x-ray general radiography does not observation in-depth observation. Information about the anatomy of the human body and changes in disease in x-ray general radiography can be obtained but it is difficult to determine the size and shape of the actual lesion due to the disadvantage of expanding the image. In this study, PA and LAT images were acquired and cancer magnification was calculated in the images by measuring the distance of cancer samples. By adjusting the magnification the actual cancer length and thickness were measured and compared with the CT image and the actual cancer sample size. After the PA and LAT images of the inserted 6.0 mm cancer sample were obtained and the magnification was corrected, the length was 5.9 mm and the thickness was 6.1 mm. This value was measured similarly to the actual. The problem of obtaining the magnification that needs to know the actual length from the detector to the cancer sample was secured by obtaining the magnification through PA and LAT images and it is possible to accurately measure the cancer sample size. X-ray general radiography may provide useful information in situations where CT imaging is difficult.

Analysis of the Spatial Dose Rates during Dental Panoramic Radiography (치과 파노라마 촬영에서 공간선량률 분석)

  • Ko, Jong-Kyung;Park, Myeong-Hwan;Kim, Yongmin
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.509-516
    • /
    • 2016
  • A dental panoramic radiography which usually uses low level X-rays is subject to the Nuclear Safety Act when it is installed for the purpose of education. This paper measures radiation dose and spatial dose rate by usage and thereby aims to verify the effectiveness of radiation safety equipment and provide basic information for radiation safety of radiation workers and students. After glass dosimeter (GD-352M) is attached to direct exposure area, the teeth, and indirect exposure area, the eye lens and the thyroid, on the dental radiography head phantom, these exposure areas are measured. Then, after dividing the horizontal into a $45^{\circ}$, it is separated into seven directions which all includes 30, 60, 90, 120 cm distance. The paper shows that the spatial dose rate is the highest at 30 cm and declines as the distance increases. At 30 cm, the spatial dose rate around the starting area of rotation is $3,840{\mu}Sv/h$, which is four times higher than the lowest level $778{\mu}Sv/h$. Furthermore, the spatial dose rate was $408{\mu}Sv/h$ on average at the distance of 60 cm where radiation workers can be located. From a conservative point of view, It is possible to avoid needless exposure to radiation for the purpose of education. However, in case that an unintended exposure to radiation happens within a radiation controlled area, it is still necessary to educate radiation safety. But according to the current Medical Service Act, in medical institutions, even if they are not installed, the equipment such as interlock are obliged by the Nuclear Safety Law, considering that the spatial dose rate of the educational dental panoramic radiography room is low. It seems to be excessive regulation.

A Study on Gardening Theories of Li, Yu in 'Xian Qing Ou Ji' (한정우기(閑情偶寄)를 통해 본 이어(李漁)의 조원(造園) 이론)

  • Zhang, Lin;Jung, Woo-Jin;Sung, Jong-Sang
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.36 no.3
    • /
    • pp.137-148
    • /
    • 2018
  • Li Yu's Xian Qing Ou Ji was written during the late Ming and early Qing Dynasty when material culture flourished due to the development of the commercial economy. Xian Qing Ou Ji is considered a retrospective work that reflects the rich material society at that time. This study focuses on his gardening theories through the interpretation and analysis of these two texts of 'Jushibu(居室部)' and 'Zhongzhibu(種植部)' in Xian Qing Ou Ji. The results are summarized as follows. First, he explained the method of garden configuration and orientation according to the topography utilizing the theory of 'suiting one's measures to local conditions(因地制宜)'. He emphasized the detailed understanding of topography as the starting point for all the gardening theories. It stated that he tried to adjust the height of the terrain artificially to create an ideal form of 'anterior high and posterior low(前低後高)'. The successful arrangement of houses, pavilions, rockery and waterways et al. was able to be achieved because of his accurate understanding of topography. Second, 'borrowing scenery(取景在借)' means 'borrowing the outside scenery to the inside'. He applied this theory by 'viewing in motion(動觀)' and 'viewing in repose(靜觀)'. 'Viewing in motion' is seen as a positive methodology for landscape enjoyment. For example, the view through a window changes with movements of the boat, and it can portray thousands of landscape paintings which can be seen through the windows. In the case of 'viewing in repose', the window is regarded as a means of attracting outside garden views to the inside. Third, he emphasized 'the firmness of objects(制體宜堅)', where the design of windows and railings must be considered ahead of others. Fourth, he interpreted the contents of 'the pursuit of novelty(創異標新)'. This generalizes the characteristics of his gardening theory. The contents included 'hall wall(廳壁)', 'variable sun visor(活?)', 'hanging boards and couplets(聯?)' and 'method of supporting vines with bamboo screen(竹屛扶植法)'.