• Title/Summary/Keyword: 파장 스위핑 레이저

Search Result 9, Processing Time 0.02 seconds

Sweeping Linearization of Wavelength Swept Laser (파장 스위핑 레이저의 스위핑 선형화)

  • Eom, Jinseob
    • Journal of IKEEE
    • /
    • v.22 no.3
    • /
    • pp.605-612
    • /
    • 2018
  • In this paper, a new method for linear sweeping of wavelength swept laser has proposed, and the linear sweeping of 1kHz speed and 80nm range has realized by using this method. The proposed requires only one-shot calibration in the early stage on a wave pattern applied to FFP-TF. This makes the problem with nonlinear swept lasers like a cumbersome and time-consuming signal processing brought on by every recalibration to be resolved.

Flat Sweeping Automatic Hold of Wavelength Swept Laser (파장 스위핑 레이저의 평탄 스위핑 자동 유지)

  • Lee, Duk-Kyu;Eom, Jinseob
    • Journal of IKEEE
    • /
    • v.23 no.2
    • /
    • pp.606-613
    • /
    • 2019
  • In this paper, a new method for flat sweeping automatic hold of wavelength swept laser has proposed. Through the performance test on the implemented laser, even 5 hours passed, the flat sweeping has held up well, and 56nm flat sweeping range, 1kHz sweeping frequency, and 8.8mW average optical power were obtained. This showes that the proposed can eliminate the necessity of hand-operated polarization control required for previous swept lasers in case of long time operation and also optical spectrum analyzer needed to monitor the sweeping spectrum status.

Realization of Swept Source Optical Coherence Tomography with Loop Mirror Reference Arm (루프 미러로 구성된 기준팔을 가지는 파장 스위핑 OCT 구현)

  • Kim, Hoon-Sup;Namgoong, Myung-Woo;Lee, Jung-Ryul;Eom, Jin-Seob
    • Journal of Industrial Technology
    • /
    • v.27 no.B
    • /
    • pp.121-123
    • /
    • 2007
  • As a reflector of reference arm in OCT systems, a coated fiber reflector has mostly used. Instead, this paper has realized the swaept source optical coherence tomography system using a loop mirror within a reference arm. Through the experiments for a tilted thin glass plate, we found that the loop mirror is better than the coated fiber typed mirror for obtaining the clear image.

  • PDF

Sweeping Automatic Linearization for Wavelength Swept Laser Used in Structure Safety Monitoring (구조물 안전 모니터링용 파장 스위핑 레이저를 위한 스위핑 자동 선형화)

  • Lee, Duk-Kyu;Eom, Jinseob
    • Journal of Sensor Science and Technology
    • /
    • v.29 no.1
    • /
    • pp.51-58
    • /
    • 2020
  • In this study, a novel method for sweeping automatic linearization of wavelength swept laser is proposed. Through the test performed on the implemented laser, the linear sweeping is held up well with a 97% decrease in nonlinearity, and 60 nm sweeping range, 1 kHz sweeping frequency, and 8.8 mW average optical power were obtained. The proposed method uses fiber Bragg grating array, optical-electronic conversion circuit, FPGA embedded module, and a LabVIEW program to generate new compensated wave patterns which were applied to the fiber Fabry-Perot tunable filter. Linear sweeping can reduce the cumbersome and time-consuming recalibration process required for nonlinear sweeping. Additionally, the proposed method provides more accurate measurement results for the structure safety monitoring system.

Sweeping Center Setting Automation for Wavelength Swept Laser used in SS-OCT (SS-OCT용 파장 스위핑 레이저를 위한 스위핑 중심 세팅 자동화)

  • Eom, Jinseob
    • Journal of Sensor Science and Technology
    • /
    • v.26 no.5
    • /
    • pp.324-330
    • /
    • 2017
  • In this paper, the automation of sweeping center setting for wavelength swept laser used in SS-OCT has implemented. For 3 regions where the initial FFP-TF pass wavelength can be located, each different DC voltage pattern is applied to FFP-TF. Through its performance test to the laser, fast and exact setting to sweeping central wavelength, flat sweeping with ${\pm}0.5dB$ fluctuation range, and 10 mW average optical power were obtained. This shows that the realized automatic setting process can replace an inconvenient manual setting operation used for current wavelength swept laser. Additionally it cuts costs for optical spectrum analyzer necessary to laser spectrum monitoring.

Sweeping Linearization of Wavelength Swept Laser using PID Control (PID 제어를 이용한 파장 스위핑 레이저의 스위핑 선형화)

  • Eom, Jinseob
    • Journal of Sensor Science and Technology
    • /
    • v.29 no.6
    • /
    • pp.412-419
    • /
    • 2020
  • In this study, a PID control method for sweeping automatic linearization of a wavelength swept laser is proposed. First, the closedloop transfer function embodying the PID control is derived. Through the simulation of the function, Kp = 0.022, Ki = 0.008, Kd = 0.002 were obtained as the best PID coefficients for fast linear sweeping. The performance test using the PID coefficients showed that linear sweeping was held up well with a 98.7% decrement in nonlinearity after the 10th feedback, and 45 nm sweeping range, 1 kHz sweeping frequency, and 8.8 mW average optical power were obtained. The equipment consists of a fiber Bragg grating array, an optical-electronic conversion circuit, and a LabVIEW FPGA program. Every 5s, automatic feedback and PID control generate a new compensated waveform and produce a better linear sweeping than before. Compared with nonlinear sweeping, linear sweeping can reduce the cumbersome and time-consuming recalibration processes and produce more accurate measurement results.

Acquirement of in vivo epidermal cross-sectional image by using swept source optical coherence tomography (SS-OCT 방식을 이용한 생체의 표피단면 영상 획득)

  • Kim, Hoon-Sup;Lim, Hae-Jin;Eom, Jin-Seob
    • Journal of Industrial Technology
    • /
    • v.28 no.A
    • /
    • pp.163-166
    • /
    • 2008
  • In this paper, the swept source optical coherence tomography system has realized using a free-space interferometer based on a beam splitter. Personal computer has completed the control for tunable wavelength laser digitally and the B-scan motor as well. From each experiment for an onion and a salmon egg, we confirmed that the in vivo epidermal cross-sectional images for them can be obtained appropriately.

  • PDF

Automatic Sweep Flattening for Wavelength Sweeping Laser of SS-OCT (SS-OCT용 파장 스위핑 레이저를 위한 자동 스위프 평탄화)

  • Eom, Jinseob
    • Journal of Sensor Science and Technology
    • /
    • v.26 no.1
    • /
    • pp.44-49
    • /
    • 2017
  • In this paper, the automatic sweep flattening for wavelength swept laser of SS-OCT has implemented. Through its performance test applied to the laser, 50 nm flat sweeping range, ${\pm}0.5dB$ fluctuation range, 22 sec the time required, and 10 mW average optical power were obtained. This shows that the realized automatic process can replace the inconvenient manual operation used for polarization control of current sweeping laser. Additionally it cuts costs for optical spectrum analyzer necessary to sweep monitoring.

Measuring strain on fiber Bragg grating sensors with a linear wavelength sweeping laser (파장 선형 스위핑 레이저를 이용한 광섬유 격자 센서의 스트레인 측정)

  • Eom, Jinseob
    • Journal of Sensor Science and Technology
    • /
    • v.30 no.6
    • /
    • pp.420-428
    • /
    • 2021
  • In this study, linearized sweeping of a wavelength sweeping laser was realized. This technique was used to measure the strain on a fiber Bragg grating(FBG) sensor. For linear sweeping, PID control over the wavelength difference between linear and nonlinear sweeping was employed. The performance test showed that linear sweeping with a 46 nm range and a 1 kHz frequency held up well with a 99.5 % decrement in nonlinearity after the 120th feedback. When attached to a strain gage, the FBG sensor registered strain that matched the data sheet within a difference of 4.5[με]. Altogether, linear sweeping can play a leading role in monitoring a safety of large SOC structures as well as in other wavelength sweeping laser related fields.