• Title/Summary/Keyword: 파이프 쿨링

Search Result 15, Processing Time 0.021 seconds

Study on Thermal Crack Control Using Pipe-Cooling in Massive Concrete Foundation of Urban Bridge (파이프 쿨링을 이용한 도심 교량 기초 매스 콘크리트의 수화열 제어에 관한 연구)

  • 이주호;배한욱;우승민;우종일;하봉태;김지상
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.05a
    • /
    • pp.41-46
    • /
    • 2002
  • Recently, the design and construction of massive concrete structures are increased, But, the temperature rise within a large concrete mass makes the construction of massive concrete structures be very difficult. Therefore, various techniques of the thermal stress control of the mass concrete have been widely used. One of them is pipe-cooling which reduces the temperature of concrete with flowing water. It was shown to be possible to construct the massive concrete foundation of urban bridge successfully by application of pipe-cooling system with steel pipe and water circulation. It was also found to expected to make it possible to reduce the probability of thermal crack development in a massive concrete foundation of urban bridge by pipe-cooling system.

  • PDF

Design of Closed Loop Pipe Cooling System (냉각수 순환 형태의 파이프 쿨링 공법의 설계)

  • 박찬규;왕인수;구자중
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2001.11a
    • /
    • pp.52-57
    • /
    • 2001
  • In order to control hydration heat in mass concrete, pipe cooling method has been widely used. The pipe cooling method leads to the decrease of curing period by lagging materials as well as the decrease of temperature difference between center and surface of mass concrete member, There are two methods in the pipe cooling system, which are open loop system and closed loop system. However open loop pipe cooling system cannot be applied to the mass concrete structures when cooling water supply is difficult. To control hydration heat of high strength mass foundation in the central area of city, closed loop pipe cooling system was developed to solve the cooling water supply. This paper reports the performance results of hydration heat control with closed loop pipe cooling system.

  • PDF

The Cooling Effect of Pipe Cooling in Mass Concrete Structures (매스 콘크리트 구조물의 파이프 쿨링에 의한 냉각효과)

  • 오병환;신경준;차수원
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.04a
    • /
    • pp.299-304
    • /
    • 1999
  • Cracking of concrete is one of the main issues of structural design next to ensuring the load-bearing capacity. Thermal cracking is a recurring concern in the production of concrete structures in particular when large, massive structures are considered. Thremal stresses arise from the differential temperature distribution either within s sturcture or between newly cast sectons and adjoining older parts. There are many different methods of reducing thermal stresses. A method often used for reducing temperature within a structure, is to cool the inner core with embedded cooling pipes. In this study, finite element method is employed for thermal analysis of concrete structures. To calculate water temperature variation in pipe, the conservation of thermal energy in internal flow was adopted. The cooling effect of pipe cooling is studied with several factors like convective coefficient, water temperature, concrete heat characteristics

  • PDF

A Study on the Effect of Pipe Cooling in Mass-Concrete (매스콘크리트의 파이프 쿨링 효과)

  • 윤승권;김은경;김래현;신치범
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1995.10a
    • /
    • pp.329-333
    • /
    • 1995
  • The usual methods for the temperature control of mass-concrete structures include the use of low-heat cement, pre-cooling, or pipe-cooling. In order to control the heat of hydration of mass-concrete structures such as massive pier or anchor block, and mat foundation, the pipe cooling method is widely acceptable for pratical use. In this paper, method of analysis using the Finite Element Method was applied to analyze the heat exchange on the field of three dimensional thermal conduction. The result of analysis Well agreed with experimentally measurement data by "KUMATANI". The method of this analysis will be used widely to control the heat of hydration by the pipe cooling in mass-concrete.-concrete.

  • PDF

Application of Pipe-cooling Method in the Concrete Wall Structure (벽체 구조물의 파이프쿨링 공법 적용성 분석)

  • Shin, Kyoung-Seop;Kim, Se-Hoon;Cha, Soo-Won
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.501-504
    • /
    • 2008
  • A number of structures constructed during past decades have suffered from safety and serviceability problems due to deterioration and many engineers have been increasingly concerned about durability of concrete. Pipe-cooling method has been popularly used in the massive concrete to reduce temperature of the structure. Until now, usually this pipe-cooling method was applied only in foundation concrete structures, but it is newly tried to apply in the wall structure. We analyzed thermal stress of wall structure with the general structural analysis program that will be able to express the pipe-cooling element. We studied about the effect of reducing temperature and cracking control in the wall structure which can be applied in a pipe-cooling method with the analytical result which follows in an arrangement of the cooling pipe.

  • PDF