• Title/Summary/Keyword: 파열 건의 상태

Search Result 28, Processing Time 0.02 seconds

Anterior Cruciate Ligament Augmentation Using Autogenous Semitendinosus Tendon (자가 반건양건을 이용한 전방 십자 인대 보강술)

  • Choi, Nam-Yong;Han, Chang-Hwan;In, Yong;Moon, Chan-Woong;Choi, Seung-Woog;Jin, Sung-Ki
    • Journal of the Korean Arthroscopy Society
    • /
    • v.12 no.1
    • /
    • pp.12-17
    • /
    • 2008
  • Purpose: This study presents clinical results of anterior cruciate ligament(ACL) augmentation using autogenous two-strand semitendinosus tendon in the treatment of partial ACL tears with preservation of residual portion. Materials and Methods: From January 2004 to June 2006, twenty two patients who had an ACL injury underwent ACL augmentation using autogenous two-strand semitendinosus tendon were enrolled in this study. We evaluated the clinical results with regard to clinical findings(range of motion, Lachman test, pivot shift test), standard knee scales(Lysholm, Modified Feagin Scoring System), and KT-1000 arthrometer testing. Results: At minimum one year postoperatively, there was no limitation of range of motion. Lachman and pivot shift tests were negative in all knees. On instrumented anterior laxity test by KT-1000 arthrometer, mean side to side difference was improved from 4.6mm preoperatively to 1.7mm postoperatively. Average Lysholm score was improved from 70 to 92. Ninety one percent of cases were rated as good or excellent in Modified Feagin Scoring System. Conclusion: Augmentation using autogenous two-strand semitendinosus tendon with preservation of residual portion of the ACL seems to be an acceptable method for restoring knee stability and proprioceptive function.

  • PDF

Postoperative Imaging of Rotator Cuff Tear (회전근개 파열의 수술 후 영상)

  • Min Hee Lee;Hee Jin Park;Ji Na Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.6
    • /
    • pp.1388-1401
    • /
    • 2021
  • Postoperative imaging of the rotator cuff may be performed routinely, even if pain or disability develops after surgery or if there are no symptoms. Postoperative images are obtained through MRI or US, and the purpose is to confirm the integrity of the restored tendon in general. Postoperative MRI has a relatively poor diagnostic accuracy compared to that of preoperative images because various materials used in surgeries deteriorate the image quality. US can dynamically check the condition of the restored tendon and avoid artifacts from the surgical instruments used for recovery. Although imaging findings are not always consistent with the clinical symptoms or prognosis, sub-deltoid fluid retention is more important for pain and functional recovery than the thickness of the reconstructed tendon. Strain elastography can also be a useful method for predicting the prognosis.

New Technique for the Reconstruction of Both Anteromedial & Posterolateral Bundles of ACL (전방십자인대의 전내측 다발 및 후외측 다발을 각각 재건하는 새로운 수술 수기)

  • Ha Chul-Won;Awe Soo-Ik
    • Journal of the Korean Arthroscopy Society
    • /
    • v.6 no.2
    • /
    • pp.195-199
    • /
    • 2002
  • This article is to report a new technique for reconstruction of the anteromedial and posterolateral bundles of anterior cruciate ligament by separate tensioning and fixation of the each bundle. Method : Tibial and femoral tunnels were made with conventional technique of anterior cruciate ligament reconstruction. Tibial tunnel was enlarged $5\~7$ mm in anterior-posterior direction to make oval it in cross section. When preparing the Achilles tendon allograft, bone plug portion was trimmed as the conventional technique. The tendinous portion was trimmed as two separate bundles by dividing the tendinous portion longitudinally, so the graft is shaped like 'Y'. The bone plug portion of allograft was inserted into the femoral tunnel and fixed with absorbable cross pins. Two ligamentous portionss of the distal part of the grafts were tensioned separately at the external orifice. Anteromedial bundle was fastened under maximum tension with the knee flexed 90 degrees by post-tie method. The posterolateral bundle was fixed by the same technique with the knee in full extension. Then, an absorbable interference screw was inserted between the two bundles upto the upper end of the tibial tunnel, to get more initial rigidity of the reconstructed graft as well as to locate the two bundles in more anatomic position.

  • PDF

Second-Look Arthroscopy after ACL Reconstruction with Autograft Tendons (자가건을 이용한 전방 십자 인대 재건술 후 이차 관절경 검사)

  • Fang, Zhen-Zhu;Yoo, Moon-Jib;Kim, Myung-Ho;Bahng, Seung-Chu;Kim, You-Jin;Park, Hee-Gon
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.6 no.1
    • /
    • pp.38-44
    • /
    • 2007
  • Purpose: To evaluate status of reconstructed ACL and changes around graft through second-look arthroscopy after arthroscopic reconstruction of the ACL with autograft tendons. Material and Methods: Between Jun. 2003 and Feb. 2007, the second look arthroscopy was performed on 22 cases. Second-look arthroscopy was conducted on average 15.1 $(7\sim31)$ months after reconstruction. 15 cases received hamstring tendon autograft, 7 cases received bone-patellar tendonbone autograft. We measured graft tension using displacement by probing, synovial coverage by visual analysis at second-look arthroscopy The assay in Lysholm score, Lachmann test and KT-2000 arthrometer were evaluated status of reconstructed ACL. Results: The hamstring tendon group showed normal tension in 11 cases and lax tension in 4 cases. The patellar tendon group showed normal tension in 3 cases, lax tension in 2 cases and partial tear in 2 cases. In the hamstring tendon group, synovial coverage was good in 11 cases, half in 3 cases and pale in 1 case, and the bone-patellar tendon-bone group was good in 4 cases and half in 3 cases. The patellar tendon group was superior to the hamstring tendon group in Lysholm score (p<0.05), but insignificance difference in KT-2000 arthrometer results statistically. Conclusion: The hamstring tendon group was superior to the bone-patellar tendon-bone group in second-look arthroscopy after ACL reconstruction with autograft tendons results, but long term follow up will be necessary to further evaluated.

  • PDF

All-Inside Meniscal Repair Using FasT-Fix (FasT-Fix를 이용한 All-Inside 반월연골판 봉합술)

  • Jung, Yu-Hun;Choi, Nam-Hong;Kim, Byeong-Yeon
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.12 no.1
    • /
    • pp.24-28
    • /
    • 2013
  • Purpose: All-inside meniscal repair using FasT-Fix (Smith & Nephew Endoscopy, Andover, Massachusetts, USA) is a popular method for the meniscal tear. However, there was no report after all-inside repair using FasT-Fix for the meniscal tear in Korea. Therefore, the purpose of this retrospective study was to report clinical outcomes after all-inside meniscal repair using FasT-Fix. Materials and Methods: 25 consecutive patients underwent meniscal repairs using FasT-Fix for tears of the posterior horn of the medial or lateral menisci combined with hamstring anterior cruciate ligament (ACL) reconstructions. Postoperative evaluations included Lysholm knee score and Tegner activity scale. Using clinical criteria, a repaired meniscus was considered healed if there was no effusion or joint line tenderness, negative McMurray test, and no sense of giving way. Results: The average follow-up was 47.9 months (range, 40 to 61 months). At follow-up, the mean Lysholm score was 91.8 and the mean Tegner activity scale was 5.6. According to clinical criteria, 20 (80%) menisci was healed, and 5 (20%) failed. Conclusion: All-inside meniscal repair using FasT-Fix showed satisfactory results in patients with hamstring ACL reconstructions.

  • PDF

Posterior Internal Impingement of the Shoulder in Baseball Players -Preliminary Report of 5 Cases Study- (야구 선수에서의 견관절 내부 후방 충돌 -5예에 대한 예비보고-)

  • Kim, Young-Kyu;Choi, Kwang-Woon
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.4 no.1
    • /
    • pp.36-42
    • /
    • 2005
  • Purpose: To investigate the arthroscopic findings, and to evaluate the clinical outcomes of the treatment of posterior internal impingement of the shoulder in baseball players. Materials and Methods: We followed up 5 cases who were diagnosed as posterior internal impingement for the mean 15 months. All of the cases complained of the pain in the posterior shoulder at late cocking, and were positive in the relocation test added by hyper-horizontal abduction at $120^{\circ}$ abduction of the arm. We sutured posterior labral tear and SLAP lesion arthroscopically, and conducted debridement for rotator cuff. Three cases were performed of anterior capsular plication and the other two were performed of thermal capsular shrinkage. Pain, range of motion, and level of return to sports activity were assessed for the results. Results: As to the arthroscopic findings, all the five cases showed the fraying in posterosuperior labrum, and two of them was accompanied with the flap tear in posterosuperior labrum and the other one was accompanied with type 2 SLAP lesion. All the cases showed the fraying in supraspinatus, and one case showed partial tear. Meanwhile, in all the cases, the rotator cuff was impinged to the labrum at $90^{\circ}{\sim}120^{\circ}$ of abduction and external rotation. As to the postoperative results, all the cases did not complain of pain or instability while pitching, and the competition was recovered to be the mean 88%($80{\sim}100%$) of that before the injury. Conclusion: Definite diagnosis for the posterior internal impingement would be possible through arthroscopic examination. Favorable outcomes could be obtained with capsular plication or shrinkage for anterior microinstability and stretching exercise for posterior capsule tightness inducing the internal impingement.

  • PDF

Numerical Modeling for Effect on Bund Overtopping Caused by a Catastrophic Failure of Chemical Storage Tanks (저장시설의 순간 전량 방출 시 방류벽의 월파 효과에 대한 수치모델링)

  • Min, Dong Seok;Phark, Chuntak;Jung, Seungho
    • Korean Chemical Engineering Research
    • /
    • v.57 no.1
    • /
    • pp.42-50
    • /
    • 2019
  • As the industry develops in Korea, the use of hazardous chemicals is increasing rapidly and chemical accidents are increasing accordingly. Most of the chemical accidents are caused by leaks of hazardous chemicals, but there are also accidents in which all the substances are released instantaneously due to sudden high temperature/pressure or defection of the storage tanks. This is called catastrophic failure and its frequency is very low, but consequence is very huge when it occurs. In Korea, there were 15 casualties including three deaths due to catastrophic rupture of water tank in 2013, and 64 instances of failures from 1919 to 2004 worldwide. In case of catastrophic failure, it would be able to overflow outside the bund that reduces the evaporation rate and following consequence. This incident is called overtopping. Overseas, some researchers have been studying the amount of external overflow depending on bund conditions in the event of such an accident. Based on the previous research, this study identified overtopping fraction by condition of bund in accordance with Korea Chemicals Controls Act Using CFD simulation. As a result, as the height increases and the distance to the facility decreases while meeting the minimum standard of the bund capacity, the overtopping effect has decreased. In addition, by identifying the effects of overtopping according to atmospheric conditions, types of materials and shapes of bunds, this study proposes the design of the bund considering the effect of overtopping caused by catastrophic failure with different bund conditions.

Failure of Cross-Pin Femoral Fixation after Anterior Cruciate Ligament Reconstruction - A Case Report - (전방십자인대 재건술후 대퇴골 경골핀 고정의 실패 - 증례보고 -)

  • Lee Kee-Byoung;Kwon Duck-Joo;Ji Yong-Nam
    • Journal of the Korean Arthroscopy Society
    • /
    • v.7 no.1
    • /
    • pp.92-95
    • /
    • 2003
  • A 34-year-old man with ACL total rupture due to slip down injury, had received ACL reconstruction using autogenous hamstrings tendon with cross-pin femoral fixation. Postoperative course was as usual. But postoperative 3 months later, he complained posterolateral knee pain, recurrent effusion and mild instability. He was managed repeatitive aspiration and nonsteroid antiinflammatory drugs but was failed to relieve symptoms & signs. In CT scans, perforation of posteromedial femoral cortex of lateral femoral condyle was found. In second look arthroscopy, two pieces of broken femoral cross pin were found in between tibiofemoral Joint which was badly injured cartilage. We considered malposition of pins was the main cause of failure. We propose that femoral tunnel must be made more acute angle and femoral cross-pin guide must be positioned more external rotation 10-20 degree than transepicondylar axis made confirm the cross-pin tunnel position in order to avoid posterior cortex perforation and early failure.

  • PDF