• Title/Summary/Keyword: 파라미터연구

Search Result 3,193, Processing Time 0.032 seconds

The Effect of Nuclear Overhauser Enhancement in Liver and Heart $^{31}P$ NMR Spectra Localized by 2D Chemical Shift Technique (이차원 화학변위 기법을 이용한 간 및 심장 $^{31}P$ 자기공명분광에서의 Nuclear Overhauser 효과에 대한 연구)

  • Ryeom Hun-Kyu;Lee Jongmin;Kim Yong-Sun;Lee Sang-Kwon;Suh Kyung-Jin;Bae Sung-Jin;Chang Yongmin
    • Investigative Magnetic Resonance Imaging
    • /
    • v.8 no.2
    • /
    • pp.94-99
    • /
    • 2004
  • Purpose : To investigate the signal enhancement ratio by NOE effect on in vivo $^{31}P$ MRS in human heart muscle and liver. we also evaluated the enhancement ratios of different phosphorus metabolites, which are important in 31P MRS for each organ. Materials and Methods : Ten normal subjects (M:F = 8:2, age range = 24-32 yrs) were included for in vivo $^{31}P$ MRS measurements on a 1.5 T whole-body MRI/MRS system using $^1H-^{31}P$ dual tuned surface coil. Two-dimensional Chemical Shift Imaging (2D CSI) pulse sequence for $^{31}P$ MRS was employed in all $^{31}P$ MRS measurements. First, $^{31}P$ MRS performed without NOE effect and then the same 2D CSI data acquisitions were repeated with NOE effect. After postprocessing the MRS raw data in the time domain, the signal enhancements in percent were estimated from the major metabolites. Results : The calculated NOE enhancement for liver $^{31}P$ MRS were $\alpha-ATP\;(7\%),\;\beta-ATP\;(9\%),\;\gamma-ATP\;(17\%),\;Pi\;(1\%),\;PDE\;(19\%)$ and $PME\;(31\%)$. Because there is no creatine kinase activity in liver, PCr signal is absent. For cardiac $^{31}P$ MRS, whole body coil gave better scout images and thus better localization than surface coil. In $^{31}P$cardiac multi-voxel spectra, DPG signal increased from left to right according to the amount of blood included. The calculated enhancement for cardiac $^{31}P$ MRS were : $\alpha-ATP\;(12\%),\;\beta-ATP\;(19\%),\;\gamma-ATP\;(30\%),\;PCr\;(34\%),\;Pi\;(20\%),\;(PDE)\;(51\%),\;and\;DPG\;(72\%)$. Conclusion : Our results revealed that the NOE effect was more pronounced in heart muscle than in liver with different coupling to 1H spin system and thus different heteronuclear cross-relaxation.

  • PDF

Characteristics of Light-evoked Retinal Ganglion Cell Activity with Postnatal Maturation in SD Rat (SD rat 망막신경절세포의 생후 성숙기간에 따른 빛 자극 반응 특성)

  • Ye, Jang-Hee;Goo, Yong-Sook
    • Progress in Medical Physics
    • /
    • v.16 no.4
    • /
    • pp.214-219
    • /
    • 2005
  • As part of Korean retinal prosthesis project, we have provided preliminary experimental results regarding voltage parameters for the stimulation of chemically degenerated rabbit retina. Since our APB-treated chemically degenerated retina is only ON-pathway blocked, now we switch our experiments to more appropriate retinal degeneration model, genetically degenerated retina model (RD mouse: rd/rd (C3H/HeJ)). Before studying with RD mouse, we started control experiments with normal SD rat to understand characteristics of retinal ganglion ceil activity with postnatal maturation in rodents. Ganglion cell activities were recorded with 8${\times}$8 multi-electrode array. Moving spontaneous bursts appeared until postnatal day of 15. During pre-eye opening period, no light evoked response appeared. After postnatal day of 2 weeks (post-eye opening period), ON-, OFF- and ON/OFF response appeared. The fractional distributions of ON, OFF, and ON/OFF ganglion cell is about $40\%,\;50\%$, and $5\%$. The percentage ($\%$) of light evoked response in each dorso-temporal, ventral, and dorso-nasal area of eye is about $50\%,\;37.5\%$ and $12.5\%$, respectively. We concluded that the optimal period for experiment in rodent is about postnatal day of 2${\~}$3 weeks.

  • PDF

Comparison of Retinal Ganglion Cell Responses to Different Voltage Stimulation Parameters in Normal and rd1 Mouse Retina (정상망막과 변성망막에서 전압자극 파라미터 변화에 따른 망막신경절세포의 반응 비교)

  • Ye, Jang-Hee;Ryu, Sang-Baek;Kim, Kyung-Hwan;Goo, Yong-Sook
    • Progress in Medical Physics
    • /
    • v.21 no.2
    • /
    • pp.209-217
    • /
    • 2010
  • Retinal prostheses are being developed to restore vision for the blind with retinal diseases such as retinitis pigmentosa (RP) or age-related macular degeneration (AMD). Since retinal prostheses depend upon electrical stimulation to control neural activity, optimal stimulation parameters for successful encoding of visual information are one of the most important requirements to enable visual perception. Therefore, in this paper, we focused on retinal ganglion cell (RGC) responses to different voltage stimulation parameters and compared threshold charge densities in normal and rd1 mice. For this purpose, we used in vitro preparation for the retina of normal and rd1 mice on micro-electrode arrays. When the neural network of rd1 mouse retinas is stimulated with voltage-controlled pulses, RGCs in degenerated retina also respond to voltage amplitude or voltage duration modulation as well in wild-type RGCs. But the temporal pattern of RGCs response is very different; in wild-type RGCs, single peak within 100 ms appears while in RGCs in degenerated retina multiple peaks (~4 peaks) with ~10 Hz rhythm within 400 ms appear. The thresholds for electrical activation of RGCs are overall more elevated in rd1 mouse retinas compared to wild-type mouse retinas: The thresholds for activation of RGCs in rd1 mouse retinas were on average two times higher ($70.50{\sim}99.87\;{\mu}C/cm^2$ vs. $37.23{\sim}61.65\;{\mu}C/cm^2$) in the experiment of voltage amplitude modulation and five times higher ($120.5{\sim}170.6\;{\mu}C/cm^2$ vs. $22.69{\sim}37.57\;{\mu}C/cm^2$) in the experiment of voltage duration modulation than those in wild-type mouse retinas. This is compatible with the findings from human studies that the currents required for evoking visual percepts in RP patients is much higher than those needed in healthy individuals. These results will be used as a guideline for optimal stimulation parameters for upcoming Korean-type retinal prosthesis.

Dynamic Characteristic Analysis Procedure of Helicopter-mounted Electronic Equipment (헬기 탑재용 전자장비의 동특성 분석 절차)

  • Lee, Jong-Hak;Kwon, Byunghyun;Park, No-Cheol;Park, Young-Pil
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.8
    • /
    • pp.759-769
    • /
    • 2013
  • Electronic equipment has been applied to virtually every area associated with commercial, industrial, and military applications. Specifically, electronics have been incorporated into avionics components installed in aircraft. This equipment is exposed to dynamic loads such as vibration, shock, and acceleration. Especially, avionics components installed in a helicopter are subjected to simultaneous sine and random base excitations. These are denoted as sine on random vibrations according to MIL-STD-810F, Method 514.5. In the past, isolators have been applied to avionics components to reduce vibration and shock. However, an isolator applied to an avionics component installed in a helicopter can amplify the vibration magnitude, and damage the chassis, circuit card assembly, and the isolator itself via resonance at low-frequency sinusoidal vibrations. The objective of this study is to investigate the dynamic characteristics of an avionics component installed in a helicopter and the structural dynamic modification of its tray plate without an isolator using both a finite element analysis and experiments. The structure is optimized by dynamic loads that are selected by comparing the vibration, shock, and acceleration loads using vibration and shock response spectra. A finite element model(FEM) was constructed using a simplified geometry and valid element types that reflect the dynamic characteristics. The FEM was verified by an experimental modal analysis. Design parameters were extracted and selected to modify the structural dynamics using topology optimization, and design of experiments(DOE). A prototype of a modified model was constructed and its feasibility was evaluated using an FEM and a performance test.

Effect of Substrata Surface Energy on Light Scattering of a Low Loss Mirror (기판의 표면에너지가 반사경의 산란에 미치는 영향)

  • Lee, Beom-Sik;Yu, Yeon-Serk;Lee, Jae-Cheul;Hur, Deog-Jae;Cho, Hyun-Ju
    • Korean Journal of Optics and Photonics
    • /
    • v.18 no.6
    • /
    • pp.452-460
    • /
    • 2007
  • Ultra-low loss ZERODUR and fused silica mirrors were manufactured and their light scattering characteristics were investigated. For this purpose, ZERODUR and fused silica substrates were super-polished by the bowl feed method. The surface roughness were 0.292 ${\AA}$ and 0.326 ${\AA}$ in rms for ZERODUR and fused silica, respectively. To obtain the high reflectivity, 22 thin film layers of $SiO_2$ and $Ta_2O_5$ were deposited by Ion Beam Sputtering. The measured light scattering of ZERODUR and fused silica mirror were 30.9 ppm and 4.6 ppm, respectively. This shows that the substrate surface roughness is not the only parameter which determines the light scattering of the mirror. In order to investigate the mechanism for additional light scattering of the ZERODUR mirror, the surface roughness of the mirror was measured by AFM and was found to be 2.3 times higher than that of the fused silica mirror. It is believed that there is some mismatch at the interface between the substrate and the first thin film layer which leads to the increased mirror surface roughness. To clarify this, the contact angle measurements were performed by SEO 300A, based on the Giriflaco-Good-Fowkes-Young method. The fused silica substrates with 0.46 ${\AA}$ in its physical surface roughness shows lower contact angle than that of the ZERODUR substrate with 0.31 ${\AA}$. This indicates that the thin film surface roughness is determined by not only its surface roughness but also the surface energy of the substrate, which depends on the chemical composition or crystalline orientation of the materials. The surface energy of each substrate was calculated from a contact angle measurement, and it shows that the higher the surface energy of the substrate, the better the surface roughness of the thin film.

A new diagnostic method for diabetic neuropathy using $TcpO_2$ ($TcpO_2$ 이용한 당뇨병성 신경병증 환자의 조기진단)

  • Hong, Hyun-Ki;Kim, Sung-Woo;Nam, Ki-Chang;Cha, Eun-Jong;Kim, Deok-Won
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.44 no.3
    • /
    • pp.1-8
    • /
    • 2007
  • PDiabetic neuropathy is one of the most common diabetes related complications including diabetic nephropathy and retinopahty. In clinical practices, nerve conduction velocity (NCV) has been used as a standard method for diagnosing diabetic neuropathy. However, it applies maximum current of 100mA to nerves causing stress and pain to patients. In this study, as a non-invasive method, $TcpO_2$ was utilized to investigate the difference and relationship between $TcpO_2$ and $SpO_2$ of normal and diabetic neuropathy subjects. In addition, a new method of diagnosing diabetic neuropathy using $TcpO_2$ is suggested. 50 normal subjects and 50 diabetic patients with neuropathy diagnosed by NCV participated in this study. Parameters used in this study were $TcpO_2$, $TcpCO_2$, and $SpO_2$. As a result of the $TcpO_2$ measurements, statistical significances were found from $TcpO_2$ of hands and feet from normal and patients group(p<0.01). $SpO_2$ measured from index finger of normal and patient groups showed no statistical significance(p>0.05). On the other hand, $SpO_2$ measured from great toes of normal and patient groups showed statistical significance(p<0.01). Correlation coefficient between $SpO_2$ of finger and $TcpO_2$ of hand was 0.400 (p<0.01) and $SpO_2$ of toe and $TcpO_2$ of foot was 0.471(p<0.01). Both correlation values were statistically significant. Sensitivities and specificities of the $TcpO_2$ method were found to be 66 % and 92 %, respectively. If the suggested $TcpO_2$ method is used periodically, prevention and early diagnosis of diabetic neuropathy would be possible.

Experimental Studies on Lead Toxicity in Domestic Cats 1. Symptomatology and Diagnostic Laboratory Parameters (고양이의 납중독에 관한 실험적 연구 1. 임상증상 및 실험실적 평가)

  • Hong Soon-Ho;Han Hong-Ryul
    • Journal of Veterinary Clinics
    • /
    • v.10 no.1
    • /
    • pp.111-130
    • /
    • 1993
  • Lead toxicity was evaluated in forty-five cats on a balanced diet, Treated with 0(control), 10, 100(low), 1, 000, 2, 000, and 4, 000(high) ppm of lead acetate orally on a body weight basis. The objectives were to establish toxic dosage level of leaf in cats, to characterize changes in behavior and clinical pathology, and to demonstrate what blood lead concentrations correlate with the known dosages of lead. Some high dose cats showed projectile vomiting, hyperactivity, and seizures. The growth rates did not appear to be altered in any of the dosed groups. Normal blood lead concentration in cats were lower than that of humans, dogs, and cattle. Blood lead concentrations of 3 to 20$\mu\textrm{g}$/100$m\ell$ could be termed a 'subclinical' range in the cat. Clinical lead toxicity in cats may have blood lead concentrations ranging 20 to 120$\mu\textrm{g}$/100$m\ell$. Zinc protoporphyrin concentrations were proportional to lead dosages and a significant ZPP elevation, greater than 50$\mu\textrm{g}$/100$m\ell$, may be indicative of clinical lead toxicity. The enzyme aminolevulinic acid dehydratase showed an inverss dose response relationship for all lead dosages and a significant ZPP elevation, greater than 50$\mu\textrm{g}$/100$m\ell$, may be indicative of clinical lead toxicity. The enzyme aminolevulinic acid dehydratase showed an inverse dose response relationship for all lead dosages and appears to be a good indicator of lead exposure in cats. Urinary aminolevuliruc acid concentrations generally increased with lead dosage, but individual values varied. Hair lead concentrations rose proportionately to lead dosages. Lead at least in high doses appears to inhibit chemotactic activity of polymorphonuclear cells and monocytes. No consistent dose response relationships were observed in hemoglobin, RBC, WBC, neutrophil, lymphocyte, monocyte, and eosinophil counts. There were no consistent dose related changes in total protein, plasma protein, BUN, and ALT values. Reticulocyte counts did not increase significantly in most lead dosage levels, and are probably of little value in diagnosing lead toxicity in cats. The fact that no significant changes were found in nerve conduction velocities may support that there was no segmental demyelination resulting from lead ingestion. The lethal dose in cats appear to range from 60 to 150mg/kg body weight. A reliable diagnosis of lead poisoning can be made utilizing blood lead, ZPP, and ALAD, and hair lead.

  • PDF

Estimation and Mapping of Soil Organic Matter using Visible-Near Infrared Spectroscopy (분광학을 이용한 토양 유기물 추정 및 분포도 작성)

  • Choe, Eun-Young;Hong, Suk-Young;Kim, Yi-Hyun;Zhang, Yong-Seon
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.43 no.6
    • /
    • pp.968-974
    • /
    • 2010
  • We assessed the feasibility of discrete wavelet transform (DWT) applied for the spectral processing to enhance the estimation performance quality of soil organic matters using visible-near infrared spectra and mapped their distribution via block Kriging model. Continuum-removal and $1^{st}$ derivative transform as well as Haar and Daubechies DWT were used to enhance spectral variation in terms of soil organic matter contents and those spectra were put into the PLSR (Partial Least Squares Regression) model. Estimation results using raw reflectance and transformed spectra showed similar quality with $R^2$ > 0.6 and RPD> 1.5. These values mean the approximation prediction on soil organic matter contents. The poor performance of estimation using DWT spectra might be caused by coarser approximation of DWT which not enough to express spectral variation based on soil organic matter contents. The distribution maps of soil organic matter were drawn via a spatial information model, Kriging. Organic contents of soil samples made Gaussian distribution centered at around 20 g $kg^{-1}$ and the values in the map were distributed with similar patterns. The estimated organic matter contents had similar distribution to the measured values even though some parts of estimated value map showed slightly higher. If the estimation quality is improved more, estimation model and mapping using spectroscopy may be applied in global soil mapping, soil classification, and remote sensing data analysis as a rapid and cost-effective method.

Relationship between Stratum Corneum Carbonylated Protein (SCCP) and Skin Biophysical Parameters (Stratum Corneum Carbonylated Protein (SCCP)의 피부 생물학적 파라미터와의 관계)

  • Lee, Yongjik;Nam, Gaewon
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.45 no.2
    • /
    • pp.131-138
    • /
    • 2019
  • Carbonylated proteins (CPs) are synthesized by the chemical reaction of basic amino acid residues in proteins with aldehyde compounds yielded by lipid peroxidation. CPs are excited by a range of light from UVA to blue light, and resulted in the generation of superoxide anion radicals ($^{\cdot}O_2{^-}$) by photosensitizing reaction. Then, they CPs induce new protein carbonylation in stratum corneum through ROS generation. Furthermore, the superoxide anion radicals produce CPs in the stratum corneum (SC) through lipid peroxidation and finally affects skin conditions including color and moisture functions. The purpose of this study was to investigate the relationship between the production of stratum corneum carbonylated protein (SCCP) and the skin elasticity. 46 healthy female Koream at the ages of 30 ~ 50 years old were participated in this study for 8 weeks. The skin test was experiment conducted into two groups; placebo group (N = 23) used cream that did not contain active ingredients, and the other group (N = 23) used cream containing the elasticity improving ingredients. Test areas were the crow 's feet and the cheek. Various non-invasive methods were carried out to measure biophysical parameters on human skin indicating that dermis density and skin wrinkle were measured by using DUB scanner and Primos premium, respectively. Skin elasticity were measured using dermal torque meter (DTM310) and balistometer (BLS780). SCCP was assessed in a simple and non-invasive method using skin surface biopsy on the cheek of the subject. The amount of SCCP was determined using image analysis. All measurements were taken at 0, 4 and 8 8week. Results revealed that the amount of CP in SC was reduced when the skin wrinkle and skin elasticity related parameters were improved. This indicates that the correlation between the elasticity improvement and the amount of CP can be used as a anti-aging indicator and applicable to the skin clinical test for the measurement of skin aging in the future.

Evaluation of Robustness of Deep Learning-Based Object Detection Models for Invertebrate Grazers Detection and Monitoring (조식동물 탐지 및 모니터링을 위한 딥러닝 기반 객체 탐지 모델의 강인성 평가)

  • Suho Bak;Heung-Min Kim;Tak-Young Kim;Jae-Young Lim;Seon Woong Jang
    • Korean Journal of Remote Sensing
    • /
    • v.39 no.3
    • /
    • pp.297-309
    • /
    • 2023
  • The degradation of coastal ecosystems and fishery environments is accelerating due to the recent phenomenon of invertebrate grazers. To effectively monitor and implement preventive measures for this phenomenon, the adoption of remote sensing-based monitoring technology for extensive maritime areas is imperative. In this study, we compared and analyzed the robustness of deep learning-based object detection modelsfor detecting and monitoring invertebrate grazersfrom underwater videos. We constructed an image dataset targeting seven representative species of invertebrate grazers in the coastal waters of South Korea and trained deep learning-based object detection models, You Only Look Once (YOLO)v7 and YOLOv8, using this dataset. We evaluated the detection performance and speed of a total of six YOLO models (YOLOv7, YOLOv7x, YOLOv8s, YOLOv8m, YOLOv8l, YOLOv8x) and conducted robustness evaluations considering various image distortions that may occur during underwater filming. The evaluation results showed that the YOLOv8 models demonstrated higher detection speed (approximately 71 to 141 FPS [frame per second]) compared to the number of parameters. In terms of detection performance, the YOLOv8 models (mean average precision [mAP] 0.848 to 0.882) exhibited better performance than the YOLOv7 models (mAP 0.847 to 0.850). Regarding model robustness, it was observed that the YOLOv7 models were more robust to shape distortions, while the YOLOv8 models were relatively more robust to color distortions. Therefore, considering that shape distortions occur less frequently in underwater video recordings while color distortions are more frequent in coastal areas, it can be concluded that utilizing YOLOv8 models is a valid choice for invertebrate grazer detection and monitoring in coastal waters.