• Title/Summary/Keyword: 파괴형식

Search Result 110, Processing Time 0.025 seconds

Decision of Ultimate Failure Mode of High-Strength Concrete Beams Using Degrading Shear Strength Model (전단내력 감소식을 이용한 고강도 콘크리트 보의 파괴형식 판정 연구)

  • 장일영;송재호;박훈규;황규철
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.05a
    • /
    • pp.207-212
    • /
    • 2001
  • The aim of this study is to present a practical and simple method for decision of ultimate failure mode of high-strength concrete beam members, based on interaction between shear strength and displacement ductility. Four tests were conducted on full-scale beam specimens having concrete compressive strength of 410kgf/$cm^{2}$. Prediction of failure mode from presented method and comparison with test results are also presented

  • PDF

공구파손의 파괴역학적 해석에 관한 기초적 연구

  • 이태세
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1992.04a
    • /
    • pp.33-37
    • /
    • 1992
  • 구조물과 기계부품에 부하를 주는 하중은 여러가지 종류가 있고, 이에 따르는 파괴의 형식도 여러가지가 있다. 그중에서도 연강압연용 로울러, 베어링 레일등은 집중 압축하중을 받는데 이들 부재의 파괴사고가 빈번히 일어나고 잇다. 압축에 의한 파괴 중 frectting, 피팅등과 같은 마모 현상은 두 재료의 표면이 서로 미끌어질때 일어나며, 이것이 공구나 기계부품의 성능과 수명을 저하시키는 주원인이 되며, 이러한 궁구나 기계 부품을 수리 또는 교환을 하기위한 인적, 경제적 손실은 막대하다. 본 연구에서는 금형등 공구의 마모편이 발생되는 마지막 과정인 크렉의 성장을 고찰하기 위하여 Sub-surface크랙 모델을 설정하여 2차원 유한요소 법으로 경계층 근방에 크랙이 존재하는 반무한 평면에 집중하중이 작용할때의 응력확대계수를 해설하였는데, 일반화된 해석법으로 혼합모드에서의 응력확대계수를 결정하였다.

Fracture Behavior of Rail Steel under Mixed Mode Loading (혼합모드하에서의 레일강의 파괴거동)

  • Chang, Dong Il;Kim, Sung Hoon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.14 no.4
    • /
    • pp.761-769
    • /
    • 1994
  • Actual load acting on rail surface in the track is the combined mode loading due to the contact rolling load of the wheels. To investigate the fracture behavior on rail steel under combined modes I and II, fracture tests were performed by using the test jigs and fracture specimen which were designed by Richard. The analysis results of experimental fracture data were compared with various fracture criteria that have been introduced for determination of the crack propagation direction and the critical stress of fracture of a crack submitted to a mixed mode loading. From the results, it was shown that the actual crack propagation direction of rail steel agree with the crack propagation directions predicted by maximum tangential stress criterion and strain energy density criterion, and that fracture criterion follows principal strain criterion.

  • PDF

Stability Investigation of a Foundation Located above Limestone Cavities Using Scaled Model Tests (석회암공동 상부 기초의 안정성 검토를 위한 모형실험 연구)

  • Kim, Jong-Woo;Heo, Seok
    • Tunnel and Underground Space
    • /
    • v.26 no.6
    • /
    • pp.493-507
    • /
    • 2016
  • Scaled model tests were performed to investigate the stability of a foundation located above limestone cavities. Cavity shape was assumed to be an ellipse having 1/3 for the ratio of minor to major axis lengths. 12 different test models which have various depths, locations, inclinations, sizes and numbers of cavity were experimented and they were classified into 5 different groups. Crack initiation pressure, maximum pressure, deformation behaviors, failure modes and subsidence profiles of test models were obtained, and then the influences of those parameters on the foundation stability were investigated. No cavity model showed a general shear failure, whereas the models including various cavities showed the complicated three different failure modes which were only punching failure, both punching and shear failures, and double shear failure. The stability of foundation was found to be decreased as the cavity was located at shallower depth, the size and number of cavity were increased. Differential settlements appeared when the cavity was located under the biased part of foundation. Furthermore, subsidence profiles were found to depend on the distribution of underground cavities.

방파제케슨에 사용하는 신형식 푸팅구조의 역학적 특성과 구조해석

  • 한국어항협회
    • 어항어장
    • /
    • s.2
    • /
    • pp.86-127
    • /
    • 1988
  • 버트리스 푸팅 케슨(Buttress footing caisson) 및 상형 푸팅 케슨의 역학특성을 해명하고 구조설계법을 검토할 목적으로 재하실험을 실시했다. 재하실험에는 배근의 제약등을 고려해서 실구조물의 1/4정도의 대형모형공시체를 사용해서 푸팅부를 중심으로 해석하기위해 푸팅에 선분포하중을 재하했다. 유한요소법에 따른 선형구조해석을 실시하여 변위, 단면력과 한계상황설계법에서의 산정식에서 얻어진 단면내력과를 비교하여 동설계법의 케슨구조물에 대한 적용성에 관하여 고찰했다. 이 보고로써 얻어진 주요한 결론은 아래와 같다. (1) 재하실험에 의하면 버트리스 푸팅공시체의 파괴형식은 버트리스부의 철근에 연한 부착할열파괴였다. 또 상형푸팅공시체에서는 푸팅부의 내면전단파괴였다. 양구조물을 설계할 때는 종래의 면외력만의 검토뿐아니라 면내력도 적절히 평가할 필요가 있다. (2) 양공시체 함께 푸팅 케슨본체와의 접합부 및 푸팅과 상자옆쪽의 벽과의 접합부에 변형이 일어나 종래의 판구조설계에서 가정하고 있는 판주변의 고정조건이 만족되지 않았다. 따라서 케슨구조물의 구조해석에서 구조전체계를 취급할 필요가 있고 부재단위에서는 단면력을 과대 또는 과소로 산정할 우려가 있다. (3) 철근강복시정도까지는 구조전체계를 모델화한 유한요소법에 의한 선형구조해석결과와 실험결과가 잘 일치했다. (4) 한계상태설계법에서의 굽음내력, 전단내력 및 구열폭의 산정식은 실험결과와 비교해서 어느쪽이나 안전측의 치를 부여했다.

  • PDF

Case Study on Reliability Analysis of Offshore Wind Turbine Foundation (해상풍력기초 신뢰성해석 사례분석 연구)

  • Yoon, Gillim;Kim, Hongyeon
    • Journal of the Korean GEO-environmental Society
    • /
    • v.13 no.12
    • /
    • pp.91-98
    • /
    • 2012
  • In this paper, the behavior of offshore wind turbine(OWT) foundation which is modeled by using existing design method and FEM is compared. When the same type of foundation is designed under the same sea and ground condition, the behavior characteristics with each model are compared. As a result, the member forces between apparent fixity and distributed spring type foundation which consider the ground stiffness are not different markedly, while fixed-base type foundation shows relatively lower member forces, which results in smaller safety margin. In other words, considering ground stiffness is reasonable because soil-pile interaction affects significantly on the analysis result. A case study with a monopile shows significant errors between p-y and FEM model at the head and tip of the pile. Also, it shows that the errors at the tip with diameter increase of the pile is larger. Thus, considering ground characteristics and engineering judgment are necessary in practice. A comparison of reliability analysis between tripod and monopile type foundation on the same condition shows larger probability of failure in monopile type and it indicates that the safety margin of monopile type can be lower.

Seismic Performance of Column-Footing Connection of Modular Pier using CFT (CFT를 이용한 모듈러 교각 기둥-기초 연결부의 내진성능)

  • Kim, Ji Young;Kim, Ki Doo;Ma, Hyang Wook;Chung, Chul-Hun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.1
    • /
    • pp.73-85
    • /
    • 2014
  • The CFT (Concrete Filled steel Tubes) column-footing connection is cast-in-place embedded type which provides simple construction procedure, low cost, and superior structural performance. In this study, CFT column-footing connection of modular pier is proposed and structural performance is evaluated by experimental tests. To evaluate structural performance of the CFT column-footing connection, a series of experimental tests were performed for the 4 specimens with different embedded depth. As a result of the quasi-static test, the specimen with 0.6D (0.6 times the outside diameter of steel tube) embedded depth showed relatively low ductility than other specimens with larger embedded depth due to cone failure of base concrete occurred during the lower loading step. On the contrary, cone failure of the base concrete was not observed in the specimens with larger embedded depth than 0.9D, but typical flexural failure in lower part of CFT column was observed. With the analyses of force-displacement curve, displacement ductility, and energy dissipation capacity, it is concluded that the rational range of embedded depth of the CFT column-footing connection is from 0.9D to 1.2D in view of good seismic performance.

Flexural-Shear Behavior of Beam Members according to the Spacing of Stirrups and Tension Steel Ratio (스터럽간격과 인장철근비에 따른 고강도 콘크리트 보의 파괴거동)

  • Park, Hoon-Gyu;An, Young-Ki;Jang, Il-Young;Choi, Goh-Il
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.4
    • /
    • pp.513-521
    • /
    • 2003
  • Existing tests results have shown that confining the concrete compression region with closed stirrups improves the ductility and load-carrying capacity of beams. However, only few researchers have attempted to utilize the beneficial effects of the presence of these stirrups in design. This paper presents the result of experimental studies on the load-deflection behavior and the strengthening effect of laterally confined structural high-strength concrete beam members in which confinement stirrups have been introduced into the compression regions. Fifteen tests were conducted on full-scale beam specimens having concrete compressive strength of 41 MPa and 61 MPa. Different spacing of stirrups(0.25∼1.0d) and amount of tension steel($0.55{\sim}0.7{\rho}_b$) as major variables were investigated. And also, this study present an appropriate shear equation for decision of ultimate failure modes of high-strength concrete beams according to stirrup spacing. The equation is based on interaction between shear strength and displacement ductility. Prediction of failure mode from presented method and comparison with test results are also presenteded

An Experimental Study on the Shear Behavior of Composite Slabs Using Newly Developed Flat Deck-Plate(ACE-DECK) (신개발된 평데크플레이트(ACE-DECk)를 이용한 합성술래브의 전단거동에 관한 실험적 연구)

  • Heo, Byung-wook;Yang, Myung-Sook;Bae, Kyu-woong;Oh, Sang-Hoon
    • Journal of Korean Society of Steel Construction
    • /
    • v.13 no.3
    • /
    • pp.255-263
    • /
    • 2001
  • Longitudinal shear failure is the most common failure-type in composite slabs. In this paper, the shear-connection behavior of composite slabs with a particular profiled steel sheeting, so called ACE-DECK, having a depth of 60mm is studied experimentaly. Twenty two pull-out test specimens of different shapes, concrete topping thickness, and different steel sheeting thickness are carried out. It is founded that the shear connection behavior of composite slabs are not affected significantly in the steel sheeting thickness and concrete topping thickness. A new type of profiled steel sheeting is more effective in shear-bond strength that of existing flat-type deck plate, which can offer longitudinal shear strength in composite slope up to $3.6kgf/cm^2$

  • PDF

No Collapse Design for Typical Bridges (일반교량의 붕괴방지설계)

  • Kook, Seung-Kyu
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.27 no.3
    • /
    • pp.163-172
    • /
    • 2014
  • The purpose of earthquake resistant design for typical bridges is the No Collapse Design and the Earthquake Resistant Design Part of Roadway Bridge Design Code provides a design process to construct the Ductile Failure Mechanism for the bridge structure. However, if it is not practical to provide the Ductile Failure Mechanism due to structure types or site conditions, the Brittle Failure Mechanism is an alternative way to get the No Collapse Design. As well as the existing design process constructing the Ductile Failure Mechanism, the Earthquake Resistant Design Part provides a ductility-based design process as an appendix, which is prepared for bridges with reinforced concrete piers. According to the new design process, designer determines a required response modification factor for substructure and transverse reinforcement for confinement therefrom. In this study, a typical bridge with steel bearing connections and reinforced concrete piers is selected for which the existing as well as the ductility-based design processes are applied and different results from the two design processes are identified. Based on the results, an earthquake resistant design procedure is proposed in which designers should consider the two design processes.