• Title/Summary/Keyword: 트리열화

Search Result 63, Processing Time 0.022 seconds

A Network-adaptive Context Extraction Method for JPEG2000 Using Tree-Structure of Coefficients from DWT (DWT 계수의 트리구조를 이용한 네트워크-적응적 JPEG2000 컨텍스트 추출방법)

  • Choi Hyun-Jun;Seo Young-Ho;Kim Dong-Wook
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.30 no.9C
    • /
    • pp.939-948
    • /
    • 2005
  • In EBCOT, the context extraction process takes excessive calculation time and this paper proposed a method to reduce this calculation time. That is, if a coefficient is less than a pre-defined threshold value the coefficient and its descendents skip the context extraction process. There is a trade-off relationship between the calculation time and the image quality or the amount of output data such that as this threshold value increases, the calculation time and the amount of output data decreases, but the image degradation increases. Therefore, by deciding this threshold value according to the network environments or conditions, it is possible to establish a network-adaptive context extraction method. The experimental results showed that the range of the threshold values for acceptable image quality(better than 30dB) is from 0 to 4. The experimental results showed that in this range the Resulting reduction rate in calculation time was from $3\%\;to\;64\%$ in average, the reduction rate in output data was from $32\%$ to $73\%$ in average, which means that large reduction in calculation time and output data can be obtained with a cost of an acceptable image quality degradation. Therefore, the proposed method is expected to be used efficiently in the application area such as the real-time image/video data communication in wireless environments, etc.

A Consideration on the Causes of 22.9kV Cable Terminal Burning Accident (22.9kV 케이블 단말 부위 소손 사고의 원인에 관한 고찰)

  • Shim, Hun
    • Journal of Internet of Things and Convergence
    • /
    • v.8 no.2
    • /
    • pp.7-12
    • /
    • 2022
  • The main cause of cable accidents is the accelerated deterioration of the cable itself or internal and external electrical, mechanical, chemical, thermal, moisture intrusion, etc., which reduces insulation performance and causes insulation breakdown, leading to cable accidents. Insulation deterioration can occur even when there is no change in the appearance of the cable, so there is a difficulty in preventing cable accidents due to insulation deterioration. Since cable accidents can occur in areas with poor insulation due to the effects of overvoltage and overcurrent, it is necessary to comprehensively analyze transformers and circuit breakers, and ground faults caused by phase-to-phase imbalance. Ground fault accidents due to insulation breakdown of cables can occur due to defects in the cable itself and poor cable construction, as well as operational influences, arcs during operation of electrical equipment (switchers, circuit breakers, etc.). analysis is needed. This study intends to examine the causes of cable accidents through analysis of cable accidents that occurred in a manufacturing factory.

Image Data Compression Using Biorthgnal Wavelet Transform and Variable Block Size Edges Extraction (쌍직교 웨이브렛 변환과 가변 블럭 윤곽선 추출에 의한 영상 데이타 압축)

  • 김기옥;김재공
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.19 no.7
    • /
    • pp.1203-1212
    • /
    • 1994
  • This paper proposes a variable block size vector quantization based on a biorthogonal wavelet transform for image compression. An image is first decomposed with the biorthogonal wavelet transform into multiresolution image and the wavelet coefficients of the middle frequency bands are segmented using the quadtree sturcture to extract the perceptually important regions in the middle frequency bands. A sedges of middle frequency bands exist the corresponding position of high frequency bands, the complicated quadtree structure of middle frequency bands is equally applied to the high frequency bands. Therefore the overhaed information of the quadtree codes needed to segment the high frequency bands can be reduced. The segmented subblocks are encoded with the codebook designed at the each scales and directions. The simulation results showed that the proposed methods could reproduce higher quality image with bit rate reduced about 20(%) than of the preceding VQ method and sufficiently reduce the bolck effect and the edge degradation.

  • PDF

Effect of Additives on Paper Aging (종이 첨가제가 종이의 노화에 미치는 영향)

  • 윤병호;이명구;최경화
    • Journal of Korea Foresty Energy
    • /
    • v.21 no.2
    • /
    • pp.25-33
    • /
    • 2002
  • One of the critical problems to preserve books and documents in libraries and archives is the deterioration. Some of previous results showed that the major cause of paper deterioration was the acid-catalyzed hydrolysis of the cellulose in paper fibres and aging rate of acidic paper was faster than that of alkaline paper. Therefore, It is necessary to remove the acid in the paper for reducing the rate of paper deterioration. It has been reported to extend the useful life of acidic paper by three to five times. Recently, It has been recognized the need for an effective method of deacidifying large quantities of books and document. However, in the previous many reports little attention was paid to the effect of paper additives. In this paper, We carried out experiment about the effect of additives on paper aging and the effect of deacidification by the gaseous ethanolamines (monoehtanolamine, diethanolamine, triehtanolamine). In result, it was found that the strength of aging was in the order of the alum+rosin>alum >AKD> control and the rate of deacidification was in the order of the monoethanolamine>diethanolamine>triethanolamine. The treatment with the gaseous ethanolamines caused decreasing of brightness and dropping of fold endurances. However, deacidification by combination treatment of the various gaseous ehtnaolamines prevented from decreasing of brightness and dropping of folding endurances.

  • PDF

A Study on Long-time Electrical Treeing Deterioration Properties According to High Frequency Voltage of Epoxy Resin (에폭시수지의 고전압 전원주파수 변화에 따른 장시간 전기적 트리잉 열화 특성연구)

  • Park, Jae-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.11
    • /
    • pp.1571-1577
    • /
    • 2013
  • Electrical tree structure is one of the most important influencing factors for electrical treeing characteristics in polymers. In this paper, we focused on the structure characteristics of electrical treeing in epoxy resins (original) insulation under different high-frequency voltages (60, 500, 1000Hz). Effects of voltage frequency on the ac electrical treeing phenomena in an epoxy resins were carried out in needle-plate electrode arrangement. To measure the treeing initiation and propagation, and the breakdown rate, constant AC of 10 kV with three different voltage frequencies (60, 500 and 1,000 Hz) was applied to the specimen in needle-plate electrode specimen at $30^{\circ}C$ of insulating oil bath. At 60 Hz, the treeing initiation time was 360 min and the propagation rate was $6.85{\times}10^{-4}mm/min$, and the morphology was dense branch type. As the voltage frequency increased, the treeing initiation time decreased and the propagation rate increased. At 1,000 Hz, the treeing initiation time was 0 min and the propagation rate was $7.81{\times}10^{-2}mm/min$, and the morphology was dense bush type.

(Very Low Bitrate Image Compression Coding Based on Fractal) (프랙탈 기반 저전송율 영상 압축 부호화)

  • 곽성근
    • Journal of the Korea Computer Industry Society
    • /
    • v.3 no.8
    • /
    • pp.1085-1092
    • /
    • 2002
  • Studies on image information processing have been performed since long time ago because in daily life most of information are acquired by the since of sight. Since there should be a lot of data to describe image as a digital form, data compression is required in order to store or transmit digital image. Lately among most of image compression methods adopted on image compression standards, transform coding methods have been primarily used which transforms the correlations between pixels of image on frequency domain before image compression. It is blown that the standard methods using especially DCT features blocking effect which is the major cause of degrading the quality of image at high compression rate. Fractal encoding using quadtree partition is applied after reducing original image, and we are to find a optimal encoding for the number of scaling bit and offset bit.

  • PDF

Degradation Measurement from Electrical Tree Image Using Foreground Object Extracting Skill (전경 물체 추출 기법을 이용한 전기트리 영상에서 열화 측정)

  • Kim, Hyeng-Gyun;Joung, Ki-Bong;Go, Seok-Man;Oh, Moo-Song;Kim, Teh-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11b
    • /
    • pp.270-273
    • /
    • 2001
  • Electrical tree is studied widely by manufacture state of insulating material fare and blazing fire diagnosis system of use in phenomenon of part discharge that happen for main cause of dielectric breakdown of equipment for electric power. Use process that draw tree pattern here measuring above zero to study special quality of this electricity tree, real-time processing by image processing is proposed because reproduction of tree blazing fire process drops and pattern of tree is difficult correct quantification of tree growth by existent visual observation by involution. This research presents general process that need in image processing of tree blazing fire, and that remove various noises that happen in above zero by measuring electrical tree dividing background and complete view in measured above zero taking advantage of specially proposed complete view object abstraction techniques effectively and quantification of tree becomes easy naturally, can apply to dielectric breakdown estimate because can chase growth process of tree.

  • PDF

Preparation Method of 20wt% $Al_2$$O_3$/3Y-$ZrO_2$Composite through in situ Transformation of m-$ZrO_2$and its Mechanical Properties (m-$ZrO_2$의 in situ transformation에 의한 20wt% $Al_2$$O_3$/3Y-$ZrO_2$복합체 제조 및 향상된 기계적 특성)

  • 강건택;임경란
    • Journal of the Korean Ceramic Society
    • /
    • v.37 no.12
    • /
    • pp.1187-1191
    • /
    • 2000
  • 정방정형 지르코니아를 상온에서 안정화시키는 이트리아와, 지르코니아의 저온 열화을 억제하고 파괴강도의 증가에 기여하는 알루미나를 YAG(5Al$_2$O$_3$.3Y$_2$O$_3$) 졸의 형태로 m-ZrO$_2$와 알루미나의 혼합 slurry에 첨가하여, m-ZrO$_2$를 yttria 안정화 지르코니아로의 in situ 변환과 동시에 알루미나의 분산도를 향상시키고자 하였다. 20wt% 알루미나-지르코니아(YSZ)의 복합체 (20ATZ)를 1450$^{\circ}$~150$0^{\circ}C$에서 상압소결하여 0.5$mu extrm{m}$ 이하의 균일한 미세구조로 얻었다. 이 복합체는 정방정형 지르코니아와 $\alpha$-알루미나 상으로만 이루어지었고, 소결밀도 >99% TD이었다. 제조된 복합체의 파괴강도는 810 MPa로, 고상법으로 $Al_2$O$_3$와 3Y-ZrO$_2$분말로부터 제조된 시편의 682 MPa 보다 약 20% 향상되었고, 파괴인성은 5.52 MPa.m$^{1}$2/로 고상법으로 제조된 시편의 5.39 MPa.m$^{1}$2/과 비슷하였다.

  • PDF

A Study on the Electrical Properties of Electrical Tree Degradation in XLPE Cable Insulation (XLPE 케이블의 전기트리 열화에 따른 전기적 특성 검토)

  • Gang, Dong-Sik;Seon, Jong-Ho;Lee, Hong-Sik;Park, Jeong-Hu;Jo, Jeong-Su
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.7
    • /
    • pp.400-405
    • /
    • 2000
  • In order to improve the reliability of XLPE cables, it is necessary to understand the mechanism of electrical and water tree degradation. Especially, electrical tree initiation and propagation are important in XLPE cable insulation. This paper deals with the changes of electrical properties of XLPE cable insulation with electrical tree degradation. To understand the electrical properties of XLPE insulation, specimens were prepared by 22.9kV distribution cable and made in a type of block. Ogura needles having tip radius of 10${\mu}{\textrm}{m}$ were inserted into each block pieces. AC voltages of 8kV, 10kV and 12kV at 60Hz were applied to needle. We investigated the relationship between electrical properties(PD quantity, tan$\delta$ and DC current) and the growth of electrical tree. The electrical properties of the specimens were measured from initiation of tree to breakdown and their characteristics were analyzed.

  • PDF

A Study on the Insulation Diagnosis by Nonlinear Analysis of the Insulation Breakdown Mechanism (절연파괴 메카니즘의 비 선형 분석에 의한 절연진단에 관한 연구)

  • Lim, Yun-Seog;Jang, Jin-Kang;Kim, Sung-Hong;Park, Jae-Jun;Kim, Jae-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2262-2264
    • /
    • 1999
  • 절연체 내부의 보이드로 인하여 부분방전이 발생하면 국부 파괴와 완전절연파괴의 원인이 된다. 부분방전으로 생기는 트리잉은 절연재료를 열화시키며 부분방전 메카니즘 연구의 한 축을 이룬다. 이에 절연 파괴를 미연에 예측하고 감시하는 기술의 개발은 매우 중요하다. 이러한 관점에서, 부분방전의 메카니즘을 본래의 관점에서 비 선형적으로 해석할 수 있는 기법의 도입은 중요한 의미를 갖는다. 절연체의 부분방전을 시간 전개에 따라 해석함으로써 이후 실시간 감시 시스템 구축에 기초가 될 것이며 지금까지 수없이 시도 되어온 통계적인 방법과의 비교분석 및 데이터 베이스화에 따른 더욱 객관적이고 정확한 감지 결과가 기대된다. 부분방전 신호는 음향센서를 거쳐 개인용 컴퓨터에서 비선형적 해석기법과 통계적인 $\Phi$-q 기법을 적용하여 해석하였으며, 이 해석 결과는 다양한 해석 기준을 제공해 줄 것으로 기대된다.

  • PDF