• Title/Summary/Keyword: 트리열화

검색결과 63건 처리시간 0.03초

부분 방전 전하와 음향 방출 펄스의 동시 측정에 의한 트리잉 파괴 진단 (The Diagnosis of Treeing Breakdown Using Simultaneous Detection of Electrical Charge and Acoustic Emission Pulse of Partial Discharge)

  • 김성홍;박재준;김재환
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제10권3호
    • /
    • pp.247-254
    • /
    • 1997
  • Internal voids in insulators give rise to partial discharge, which causes a local breakdown and even entire insulation breakdown. Recently, the necessity of establishing the way to diagnose the aging of insulation materials and to predict of insulation breakdown become important. The purpose of our work are to investigate the treeing phenomena with an artificial needle shaped void by the charge of discharge and acoustic emission pulse in each phase angle area at the same time. We analyzed the .PHI.-QA-t pattern and .PHI.-AEA-t pattern using statistic operators such as pulse magnitude, pulse number, skewness, kurtosis. Therefore, the relation between the charge of discharge and acoustic emission pulse will be helpful to predict the breakdown just before the breakdown occur.

  • PDF

친환경 비가교 폴리에틸렌의 전기적 특성과 워터트리 가속열화에 관한 연구 (A Study on Electric Properties and Accelerated Water Tree Degradation of Environmental-friendly Non-crosslinked Polyethylene)

  • 이준호;공태식;김성중;권기형;이재순;구광회;조규철
    • 전기학회논문지
    • /
    • 제61권6호
    • /
    • pp.827-832
    • /
    • 2012
  • The crosslinked polyethylene (XLPE) is the most widely used insulating material for power cable. Due to its thermosetting characteristics, the XLPE can not be recycled, while the needs for the environmental friendly and recyclable insulator is rapidly increasing. In this paper, some important and basic electrical properties of non-crosslinked polyethylene such as conduction current characteristics, water the tree characteristics, AC breakdown test were experimentally investigated. It was shown that some of the tested samples had better performances from the application point of view for replacing current XLPE.

고압용 전선의 전기절연과 공간전하

  • 서광석;박진우
    • 전기의세계
    • /
    • 제39권2호
    • /
    • pp.12-24
    • /
    • 1990
  • 고분자는 전기장 내에 놓이게 되면 분극현상과 전하주입현상이 일어나며 절연체의 절연수명은 분극현상보다 전하주입에 의해 형성된 공간전하에 의하여 크게 좌우된다. 공간전하에 관한 연구에 있어서 공간전하의 정화한 측정 자체도 어려운 문제인 데, 최근에 개발된 방법인 압력펄스파 방법이 있다. 이 방법은 매우 짧은 폭의 펄스가 절연체를 통과하면서 얻은 공간전하에 관한 정보를 de convolution에 의한 후속신호처리하면 절연체내에 존재하는 전하의 공간분포에 따라서 전체전하량 등을 구할 수 있다. 고전압용 전선에 쓰이는 절연물질에서는 사용되는 전압의 종류에 따라 다른 형태의 문제점이 발견된다. dc절연에 있어서는 전압의 극성이 갑자기 바뀌는 polarity reversal에 의한 절연파괴가, 그리고 ac절연에서는 소위 트리잉 현상이라고 불리우는 전기적인 열화반응에 의한 절연체의 파괴 현상이 중요시되고 있다. 이들 모두 공간전하의 축적이 심할 수록, 그리고 기공 또는 그밖에 전기집중현상을 일으킬 수 있는 요인이 많을 수록 절연체의 절연수명을 급격히 감소한다. 따라서 절연수명을 향상시키기 위하여는 공간전하의 축적을 방지해야 하는데, 여기에는 전기적인 측면에서의 노력과 아울러 고분자 자체의 개량등의 노력도 함께 있어야 한다.

  • PDF

XLPE의 전기트리 열화에 따른 전기적특성의 변화 (Change of electrical properties of XLPE with electirical-tree degradation)

  • 강동식;류희석;선종호;최선도;이호진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2136-2138
    • /
    • 1999
  • In this study, we describe the change of electrical properties of XLPE with electrical-tree degradation. XLPE insulation was used as specimen which was cut off from 22.9kV XLPE insulated cable and made in a type of block. The applying voltages are 8kV, 10kV, 12kV and frequency is 60Hz Ogra needles having tip radius of 10$\mu\textrm{m}$ were inserted in blocks. PD quantity and $tan{\delta}$ and DC current were measured from inception of tree to breakdown and their characteristics were analyzed.

  • PDF

가지형 트리의 열화진단을 위한 방전통계량에 관한 연구 (A Study on Discharge Statistics Quantities for Deterioration Diagnosis of Branch-type Tree)

  • 신성권;김경민;김탁용;이덕진;박창옥;김재환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2345-2348
    • /
    • 1999
  • Existing $\psi$-AEA-t (phase-AEA-time) characteristic in polymer materials for power cable is good in general deterioration characteristic according to time variation, but it is difficult to clearly distinguish from deterioration state and diagnosis of deterioration is not enough to some extent. This paper is interpreted AE discharge statistics quantities measuring phase-amplitude variation of acoustic emission characteristic obtained from treeing breakdown experiment. Besides it can know useful discharge statistics quantities (AE average inception phase/amplitude, AE average maximum phase/amplitude) about so many for diagnosis of treeing deterioration.

  • PDF

해저케이블의 열화진단을 위한 트리잉의 화상처리 (Image Processing of Treeing for Diagnosis of Deterioration in Submarine Cable)

  • 이재봉;임장섭;박현빈;구할본;김태성;요시무라 노보루
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 C
    • /
    • pp.1655-1657
    • /
    • 1994
  • To measure treeing, visual measurement with an optical microscope has been used to explain breakdown mechanism by treeing in materials. The conventional direct visual method of tree deterioration observation is difficult to measure in short time processing, and impossible to analyze the deteriorated area by treeing, direction of tree growth, tree patterns etc. In this paper, we have developed a tree-measuring system using image processing for the tree growth, the area of deterioration, and other progresses of treeing. As experimental result, image processing is an effective alternative to direct visual observation method.

  • PDF

124-Mpixels/sec 하드웨어 HEVC 인코더의 화면간 예측 구현 (Implementation of Inter Prediction for 124-Mpixels/s Hardware HEVC Encoders)

  • 조승현;김현미;이석호
    • 한국방송∙미디어공학회:학술대회논문집
    • /
    • 한국방송공학회 2014년도 추계학술대회
    • /
    • pp.1-3
    • /
    • 2014
  • 본 논문에서는 하드웨어 HEVC 인코더의 화면간 예측의 구조를 제안한다. 제안된 화면간 예측은 정수화소 움직임 예측을 통해 코딩 트리 유닛 내 코딩 유닛 분할과 각 코딩 유닛의 분할모드를 결정한다. 그리고, 부화소 움직임 예측, Merge모드 판단을 통해 예측 유닛의 움직임 벡터를 확정하고 움직임 보상을 수행한다. 이 과정에서 율-왜곡 비용계산 및 보간 필터 등의 하드웨어 자원이 효율적으로 공유된다. 또한, 전력소모를 줄이기 위하여 코딩 유닛의 skip 여부의 조기 판단을 통해 부화소 움직임 예측 및 화면내-화면간 최종 예측모드 결정과정의 전부 또는 일부를 생략하는 방법을 제공한다. 제안된 화면간 예측을 포함한 하드웨어 HEVC 인코더를 구현하여 실험한 결과, 250 MHz 의 동작 주파수에서 초당 124 Mpixel 의 처리성능을 보였으며, HM-14.0 대비 PSNR 0.5~0.8 dB 수준의 화질열화를 나타냈다.

  • PDF

전경 물체 추출 기법을 이용한 전기트리 영상에서 열화 측정 (Degradation Measurement from Electrical Tree Image Using Foreground Object Extracting Skill)

  • 김형균;정기봉;고석만;오무송;김태성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집
    • /
    • pp.270-273
    • /
    • 2001
  • Electrical tree is studied widely by manufacture state of insulating material fare and blazing fire diagnosis system of use in phenomenon of part discharge that happen for main cause of dielectric breakdown of equipment for electric power. Use process that draw tree pattern here measuring above zero to study special quality of this electricity tree, real-time processing by image processing is proposed because reproduction of tree blazing fire process drops and pattern of tree is difficult correct quantification of tree growth by existent visual observation by involution. This research presents general process that need in image processing of tree blazing fire, and that remove various noises that happen in above zero by measuring electrical tree dividing background and complete view in measured above zero taking advantage of specially proposed complete view object abstraction techniques effectively and quantification of tree becomes easy naturally, can apply to dielectric breakdown estimate because can chase growth process of tree.

  • PDF

전기트리 발생/열화진행과 PD와의 관계분석 (Analysis relationship with PD characteristics and occurrence of electrical treeing)

  • 정해은;박성희;임기조;강성화
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 C
    • /
    • pp.1476-1477
    • /
    • 2006
  • Solid insulation exposed to voltage is degraded and by electrical tree process. And the degradation of the insulation is accelerated by voltage application. For this experimental, specimen of electrical tree model is made by XLPE(cross-linked polyethylene). And the size of the specimen is 7*5*7 $mm^3$. Distance of needle and plane is 2mm. Voltage applied for acceleration test are 12kV. And distribution characteristic of degraded stage is studied too. As a PD detecting and data process, discharge data acquire from PD detecting system(Biddle instrument). Their results of PD distribution show good present and are good discriminating skill.

  • PDF

14주기 열화에 따른 22.9kV TR CNCV-W 전력케이블의 Lightning-Impulse 파괴전압 특성분석 (Lightning Impulse Breakdown Voltage Characteristics for 22.9kV TR CNCV-W Power Cable Before and After Cyclic Aging for 14days)

  • 김위영;허종철;박태곤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 C
    • /
    • pp.1505-1506
    • /
    • 2006
  • XLPE 절연 전력케이블의 제조과정에서 발생하는 가교부산물을 제거할 목적으로 14주기노화를 실시한다. 이 과정에서 가교부산물이 제거되는 효과도 있지만 열에 의한 구조적 결함도 생기게 되며, 이들 모두가 뇌충격파괴전압에 영향을 준다. 22.9kV 트리억제형(TR CNCV-W) 케이블에 대하여 14주기노화 전과 후의 파괴전압을 분석하였으며, 전반적으로 노화과정이 파괴전압을 감소시키는 결과를 보였으나 60 $mm^2$ 케이블은 상승효과와 감소효과가 비슷하게 작용하는 것으로 나타났다.

  • PDF