• Title/Summary/Keyword: 튜브배열

Search Result 75, Processing Time 0.026 seconds

Stress Behaviors of Superheater Tubes under Load Change Operation in HRSG (배열회수보일러의 부하변동 운전에 따른 과열기 튜브들의 응력거동)

  • Chong, Chae-Hon;Song, Jung-Il
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.6
    • /
    • pp.33-39
    • /
    • 2008
  • The purpose of this study is not only to evaluate the stress behavior of tubes in superheater in HRSG during the load change operation but also to find root causes of failure from stress behavior. Firstly, temperature during operation was collected to perform stress analysis from actual HRSG. Part load and full load stress analysis which can be represented as the whole load change operations were performed using commercial finite element software. The possibility that can lead to tubes failure is found by stress analysis and its results is compared with metallurgical mircrostructure of failed tube which was taken from actual HRSG.

Fabrication Process of Single-walled Carbon Nanotube Sensors Aligned by a Simple Self-assembly Technique (간단한 자기 조립 기법으로 배열된 단일벽 탄소 나노 튜브 센서의 제작공정)

  • Kim, Kyeong-Heon;Kim, Sun-Ho;Byun, Young-Tae
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.48 no.2
    • /
    • pp.28-34
    • /
    • 2011
  • In previous reports, we investigated a selective assembly method of fabricating single-walled carbon nanotubes (SWCNTs) on a silicon-dioxide ($SiO_2$) surface by using only a photolithographic process. In this paper, we have fabricated field effect transistors (FETs) with SWCNT channels by using the technique mentioned above. Also, we have electrically measured gating effects of these FETs under different source-drain voltages ($V_{SD}$). These FETs have been fabricated for sensor applications. Photoresist (PR) patterns have been made on a $SiO_2$-grown silicon (Si) substrate by using a photolithographic process. This PR-patterned substrate have been dipped into a SWCNT solution dispersed in dichlorobenzene (DCB). These PR patterns have been removed by using aceton. As a result, a selectively-assembled SWCNT channels in FET arrays have been obtained between source and drain electrodes. Finally, we have successfully fabricated 4 FET arrays based on SWCNT-channels by using our simple self-assembly technique.

Thermopower Wave in Core-Shell Structures of Carbon Nanotube Chemical Fuels (나노튜브/화학연료의 동축 구조에서 생성되는 열동력 파도를 이용한 전기 에너지 생성)

  • Choi, Wonjoon;Strano, Michael S.
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.6
    • /
    • pp.615-620
    • /
    • 2013
  • There is considerable interest in developing energy sources capable of larger power densities. In our previous works, we proved that by coupling an exothermic chemical reaction with 1D nanostructures, a self-propagating reactive wave can be driven along its length with a concomitant electrical pulse of high specific power, which we identified as a thermopower wave. Herein, we discuss details about many different aspects of a thermopower wave. Different alignment degree in vertically aligned CNT films is evaluated in the reactive wave speed and correlated with its thermal reaction that affects the change in the magnitude of energy generation. The effects of the temperature-dependent properties of chemical fuels and CNTs are evaluated. Furthermore, we explore the convection and radiation portions in this thermal wave as well as the synchronization between the thermal reaction transfer and the oscillation of the electrical signal.

탄소나노튜브 첨가에 따른 복합나노섬유의 기계적-광학적 특성 변화

  • Lee, Mi-Hyeon;Song, U-Seok;Park, Jong-Yun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.289-289
    • /
    • 2010
  • 나노섬유는 지름이 수십에서 수백 나노미터(1나노미터=10억분의1m)에 불과한 초극세 물질로 비표면적이 매우 크고[1], 제작이 간편하여, 사용되어지는 고분자의 종류에 따라 에너지 환경 의료 관련 분야에서 전극소재 필터재 피복재 인공 피부등 다양한 분야에서의 활용이 가능하여 전 세계적으로 연구개발이 활발하게 이루어지고 있다. 그러나 그 자체만으로 응용하기에는 그 기계적 전기적 특성의 한계 때문에 응용의 다양성에 제약을 받고 있다. 그러나 그 자체만으로 응용하기에는 그 기계적 열적 전기적 특성을 가진 탄소나노튜브를 첨가한 복합나노섬유에 의해 그 응용영역의 한계를 넓혀가고 있다.[2] 본 연구에서는 전도성 고분자인 polymethyl methacrylate (PMMA)에 multi-walled carbon nanotubes (MWCNTs)를 첨가한 복합나노섬유를 전기방사법(electrospinning method)을 통해서 제조하였다. [2~3] CNTs 첨가농도에 따른 제조된 복합나노섬유의 형상변화와 섬유내의 CNTs 배열상태를 각각 주사전자 현미경(scanning electron microscope: SEM)과 투과전자현미경(transmission electron microscope: TEM)을 이용하여 관찰하였다. 또한, 복합나노섬유의 광학 특성 변화를 CNTs 첨가농도에 따라서 FT-IR과 Raman spectroscopy등을 이용하여 조사하였으며, 나노섬유의 tensile strength의 측정을 통해 CNTs 함량에 따른 기계적 특성 변화를 분석하였다.

  • PDF

Experimental Study on the Heat Transfer Characteristics of Spiral Fin-Tube Heat Exchangers (나선형 핀튜브 열교환기의 열전달 특성에 관한 실험적 연구)

  • Yun Rin;Kim Yongchan;Kim Sru;Choi Jong Min
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.6
    • /
    • pp.529-535
    • /
    • 2005
  • This study experimentally examines the air-side performance of spiral finned tube heat exchangers. The effects of fin spacing, fin height, and tube alignment were investigated. Reduction of fin spacing decreased the Colburn j factor. However, the effect of fin height on the Colburn j factor was negligible. An increase of tube row decreased the Nusselt number for both staggered and in-line tube alignments. However, the decrease of the Nusselt number for the in-line tube alignment was much more significant than that of the staggered tube alignment. The average Nusselt number of the staggered tube alignment was larger than that of the in-line tube alignment by $10\%$ when the Reynolds number ranged from 300 to 1700. An empirical correlation of the Nusselt number was developed by using geometric parameters of heat exchanger and correction factors. The correction factor considered the effects of tube alignment and number of tube rows on the heat transfer. The proposed correlation yielded a mean deviation of $4\%$ from the present data.

Natural Frequency Characteristics of Laminated Composite Structures Reinforced by a Wavy CNT (굴곡된 탄소나노튜브로 보강된 적층 복합재 판구조의 고유진동 특성)

  • Chultemsuren, Chunt;Choi, Hyung Bae;Lee, Sang-Youl
    • Composites Research
    • /
    • v.34 no.2
    • /
    • pp.123-128
    • /
    • 2021
  • This paper dealt with multi-scale natural frequency characteristics of wavy CNT (carbon nanotube) reinforced composites by applying the Mori-Tanaka method, rule of mixture, and Halpin-Tsai equation. By compelling benefit of an ad-hoc Eshelby tensor, the load-transfer characteristics of CNT with a waviness implanted in the polymer matrix was determined. The numerical results obtained are in good agreement with those reported by other investigators. Furthermore, the new results reported in this paper show the interactions between CNT weight, waviness ratios and layup sequences of laminated composites. Key observation points are discussed and significant considerations are given in practical designing of CNT reinforced composites.

Heat Transfer Characteristics according to the Tube Arrangement of Bundle Type Plastic Oil Cooler (플라스틱 관다발 타입 오일쿨러의 튜브 배열에 따른 열전달 특성)

  • Heo, Hyung-Seok;Bae, Suk-Jung;Kim, Hyun-Chul
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.15 no.2
    • /
    • pp.87-94
    • /
    • 2007
  • It has been argued that the use of plastics can cause problems during design and manufacture owing to their low strength, relatively poor thermal conductivity and large thermal expansion. However, the advantages of plastics e.g., corrosion resistance, low cost, curtailment of weight, design flexibility etc., can compensate abundantly for the disadvantages. This study analyzes and compares the heat transfer performance characteristics of automotive compact oil cooler composed of plastic tube bundle with conventional metal oil cooler on the same core area basis as diameter, tube thickness, number of tube or tube arrangement varies. The performance analyses are accomplished by use of computational fluid dynamics program Fluent 6.2, which is verified and compared with the results of performance tests. The result of analyses is coincided with that of experiments. Flow pattern at air side according to tube arrangement is dominant factor which affects heat dissipation in case of similar total heat transfer surface area.

Design and Estimation of Performance of Heat Regenerator for Small-scale Regenerative Radiant Tube Burner (소형 축열식 복사관 버너시스템용 축열기 설계 및 성능평가)

  • 조한창;조길원;이용국
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2004.05a
    • /
    • pp.171-176
    • /
    • 2004
  • Heat regenerator attached in small-scale regenerative radiant tube burner was designed using the theoretical computation code and was confirmed the performance of waste heat recovery ratio. From the computation, when ceramic ball of 4-5kg was used, temperature efficiency and available waste heat recovery ratio were predicted 80% and 70%, respectively. Similar efficiencies were obtained from the experiments using LPG. However, since exhaust gas temperature entered into regenerator was below 85$0^{\circ}C$ which was much lower than that we expected, preheat air temperature was lowered below 80$0^{\circ}C$.

  • PDF

pH Control of Feed Water for HRSG with Additional Injection of NH3 (암모니아 추가 주입에 의한 배열회수보일러 급수의 수소이온농도 조절)

  • Mok, Yong-kang;Moon, Seung-Jae;Lee, Jae-Heon
    • Plant Journal
    • /
    • v.11 no.2
    • /
    • pp.32-38
    • /
    • 2015
  • This study was conducted on combined cycle power plant consisting of HRSG with integral deaerator type to avoid tube failures of low pressure evaporator tubes. Based on the observation of pH variation at the discharge of boiler feed water pump by continuous pH measurement for a period of time, it was identified that pH of feed water is getting reduced as ammonia is distributed into vapor and liquid depending on the distribution ratio of ammonia in the LP drum after the deaerator. To solve this problem, the counterplan was prepared by reexamination of ammonia injection point and quantity. In conclusion, it was accomplished that 9.2~9.6 is the optimized pH range for boiler feed water by arranging additional piping for ammonia to inject directly to LP drum.

  • PDF