• Title/Summary/Keyword: 투시기 유도

Search Result 6, Processing Time 0.02 seconds

Ventral Fixation of Atlantoaxial Joint under Fluoroscopic Guidance Using Screws in a Chihuahua Dog (환축추 아탈구 견에서 투시기 유도를 통한 복측 나사 고정술)

  • Lee, Jae-Hoon;Yang, Hee-Taek;Yang, Wo-Jong;Chung, Dai-Jung;Kang, Eun-Hee;Eom, Ki-Dong;Choi, Chi-Bong;Chang, Hwa-Seok;Kim, Hwi-Yool
    • Journal of Veterinary Clinics
    • /
    • v.25 no.2
    • /
    • pp.131-135
    • /
    • 2008
  • A 5-year-old Chihuahua dog was evaluated for a tetraparesis. The dog was presented with a non-ambulatory tetraparesis and neck pain. Radiography demonstrated an atlantoaxial (AA) subluxation and increased distance between the dorsal arch of the C1 and the dorsal spinous process of the C2. The AA joint was fixed with ventral transarticular fixation using two screws under fluoroscopic guidance. Neck brace was applied during 3 weeks post-operation. After 4 weeks, the dog was fully ambulatory with improved neurological function. Postoperative radiographs confirmed reduction of the luxation and no migration of screws. The dog showed complete resolution of clinical signs without signs of recurrence till 4 months after operation. Proper angulations of screws provided under fluoroscopic guidance, enabled adequate stabilization of the AA joints using ventral transarticular screw fixation which improved neurologic outcome of the patient.

Ultrasound-guided Intervention in Lumbar Spine (요추부 초음파 유도하 중재술)

  • Moon, Sang Ho
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.6 no.2
    • /
    • pp.81-93
    • /
    • 2013
  • This review was described to investigate the feasibility of using ultrasound as an image tool for interventions of lumbar spine. This article will first provide an overview of lumbosacral spine surface anatomy and sonoanatomy. A detailed understanding of anatomy is critical for interpretation of ultrasound and procedural performance at spine. Fluoroscopy is most commonly used in interventional spine procedures, but radiation exposure is the major concern when obtaining fluoroscopic images. Ultrasound is radiation-free, is easy to use, and can provide real-time images with high accuracy. Also this device can be used in virtually any clinical setting. Ultrasound guidance offers a reliable alternative to fluoroscopy or computed tomography for lumbar interventions and can be safely performed without radiation exposure.

  • PDF

Fast Marker-based Registration of 3D CT and 2D X-ray Fluoroscopy Images (3차원 전산화 단층촬영영상과 2차원 X-선 투시영상간 표식기 기반 고속 정합)

  • Kim Gye-Hyun;Park Seong-Jin;Hong He-Len;Shin Yeong-Gil
    • Journal of KIISE:Software and Applications
    • /
    • v.33 no.3
    • /
    • pp.335-343
    • /
    • 2006
  • This paper proposes a novel technique of marker-based 2D-3D registration to combine 3D information obtained from preoperative CT images into 2D image obtained from intraoperative x-ray fluoroscopy image. Our method is divided into preoperative and intraoperative procedures. In preoperative procedure, we generate CT-derived DRRs using graphics hardware and detect markers automatically. In intraoperative procedure, we propose a hierarchical two- step registration to reduce a degree of freedom from 6-DOP to 2-DOF which is composed of in-plane registration using principal axis method and out-plane registration using minimal error searching method in spherical coordinate. For experimentation, we use cardiac phantom datasets with confirmation markers and evaluate our method in the aspects of visual inspection, accuracy and processing time. As experimental results, our method keeps accuracy and aligns very fast by reducing real-time computations.

New Method for Vehicle Detection Using Hough Transform (HOUGH 변환을 이용한 차량 검지 기술 개발을 위한 모형)

  • Kim, Dae-Hyon
    • Journal of Korean Society of Transportation
    • /
    • v.17 no.1
    • /
    • pp.105-112
    • /
    • 1999
  • Image Processing Technique has been used as an efficient method to collect traffic information on the road such as vehicle counts, speed, queues, congestion and incidents. Most of the current methods which have been used to detect vehicles by the image processing are based on point processing, dealing with the local gray level of each pixel in the small window. However, these methods have some drawbacks. Firstly, detection is restricted by image quality. Secondly, they can not deal with occlusion and perspective projection problems, In this research, a new method which possibly deals with occlusion and perspective problems will be proposed. It extracts spatial information such as the position, the relationship of vehicles in 3-dimensional space, as well as vehicle detection in the image. The main algorithm used in this research is based on an extension of the Hough Transform. The Hough Transform which is proposed to estimates parameters of vertices and directed edges analytically on the Hough Space, is a valuable method for the 3-dimensional analysis of static scenes, motion detection and the estimation of viewing parameters.

  • PDF

Ultrasound-Guided Injections in the Lumbar and Sacral Spine (요추 및 천추부에 대한 초음파 유도하 중재 시술)

  • Ko, Kwang Pyo;Song, Jae Hwang;Kim, Whoan Jeang;Kim, Sang Bum;Min, Young Ki
    • Journal of Korean Society of Spine Surgery
    • /
    • v.25 no.4
    • /
    • pp.185-195
    • /
    • 2018
  • Study Design: Literature review. Objective: Ultrasound-guided injections are a common clinical treatment for lower lumbosacral pain that are usually performed before surgical treatment if conservative treatment fails. The aim of this article was to review ultrasound-guided injections in the lumbar and sacral spine. Summary of Literature Review: Ultrasound-guided injections, unlike conventional interventions using computed tomography or C-arm fluoroscopy, can be performed under simultaneous observation of muscles, ligaments, vessels, and nerves. Additionally, they have no radiation exposure and do not require a large space for the installation of equipment, so they are increasingly selected as an alternative method. Materials and Methods: We searched for and reviewed studies related to the use of ultrasound-guided injections in the lumbar and sacral spine. Results: In order to perform accurate ultrasound-guided injections, it is necessary to understand the patient's posture during the intervention, the relevant anatomy, and normal and abnormal ultrasonographic findings. Facet joint intra-articular injections, medial branch block, epidural block, selective nerve root block, and sacroiliac joint injections can be effectively performed under ultrasound guidance. Conclusions: Ultrasound-guided injections in the lumbar and sacral spine are an efficient method for treating lumbosacral pain.

Analysis of the Imaging Dose for IGRT/Gated Treatments (영상유도 및 호흡동조 방사선치료에서의 영상장비에 의한 흡수선량 분석)

  • Shin, Jung-Suk;Han, Young-Yih;Ju, Sang-Gyu;Shin, Eun-Hyuk;Hong, Chae-Seon;Ahn, Yong-Chan
    • Radiation Oncology Journal
    • /
    • v.27 no.1
    • /
    • pp.42-48
    • /
    • 2009
  • Purpose: The introduction of image guided radiation therapy/four-dimensional radiation therapy (IGRT/4DRT) potentially increases the accumulated dose to patients from imaging and verification processes as compared to conventional practice. It is therefore essential to investigate the level of the imaging dose to patients when IGRT/4DRT devices are installed. The imaging dose level was monitored and was compared with the use of pre-IGRT practice. Materials and Methods: A four-dimensional CT (4DCT) unit (GE, Ultra Light Speed 16), a simulator (Varian Acuity) and Varian IX unit with an on-board imager (OBI) and cone beam CT (CBCT) were installed. The surface doses to a RANDO phantom (The Phantom Laboratory, Salem, NY USA) were measured with the newly installed devices and with pre-existing devices including a single slice CT scanner (GE, Light Speed), a simulator (Varian Ximatron) and L-gram linear accelerator (Varian, 2100C Linac). The surface doses were measured using thermo luminescent dosimeters (TLDs) at eight sites-the brain, eye, thyroid, chest, abdomen, ovary, prostate and pelvis. Results: Compared to imaging with the use of single slice non-gated CT, the use of 4DCT imaging increased the dose to the chest and abdomen approximately ten-fold ($1.74{\pm}0.34$ cGy versus $23.23{\pm}3.67$cGy). Imaging doses with the use of the Acuity simulator were smaller than doses with the use of the Ximatron simulator, which were $0.91{\pm}0.89$ cGy versus $6.77{\pm}3.56$ cGy, respectively. The dose with the use of the electronic portal imaging device (EPID; Varian IX unit) was approximately 50% of the dose with the use of the L-gram linear accelerator ($1.83{\pm}0.36$ cGy versus $3.80{\pm}1.67$ cGy). The dose from the OBI for fluoroscopy and low-dose mode CBCT were $0.97{\pm}0.34$ cGy and $2.3{\pm}0.67$ cGy, respectively. Conclusion: The use of 4DCT is the major source of an increase of the radiation (imaging) dose to patients. OBI and CBCT doses were small, but the accumulated dose associated with everyday verification need to be considered.