• Title/Summary/Keyword: 투사적 기법

Search Result 79, Processing Time 0.021 seconds

Enhanced Pseudo Affine Projection Algorithm with Variable Step-size (가변 스텝 사이즈를 이용한 개선된 의사 인접 투사 알고리즘)

  • Chung, Ik-Joo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.31 no.2
    • /
    • pp.79-86
    • /
    • 2012
  • In this paper, we propose an enhanced algorithm for affine projection algorithms which have been proposed to speed up the convergence of the conventional NLMS algorithm. Since affine projection (AP) or pseudo AP algorithms are based on the delayed input vector and error vector, they are complicated and not suitable for applying methods developed for the LMS-type algorithms which are based on the scalar error signal. We devised a variable step size algorithm for pseudo AP using the fact that pseudo AP algorithms are updated using the scalar error and that the error signal is getting orthogonal to the input signal. We carried out a performance comparison of the proposed algorithm with other pseudo AP algorithms using a system identification model. It is shown that the proposed algorithm presents good convergence characteristics under both stationary and non-stationary environments despites its low complexity.

Real-time Volume Rendering using Point-Primitive (포인트 프리미티브를 이용한 실시간 볼륨 렌더링 기법)

  • Kang, Dong-Soo;Shin, Byeong-Seok
    • Journal of Korea Multimedia Society
    • /
    • v.14 no.10
    • /
    • pp.1229-1237
    • /
    • 2011
  • The volume ray-casting method is one of the direct volume rendering methods that produces high-quality images as well as manipulates semi-transparent object. Although the volume ray-casting method produces high-quality image by sampling in the region of interest, its rendering speed is slow since the color acquisition process is complicated for repetitive memory reference and accumulation of sample values. Recently, the GPU-based acceleration techniques are introduced. However, they require pre-processing or additional memory. In this paper, we propose efficient point-primitive based method to overcome complicated computation of GPU ray-casting. It presents semi-transparent objects, however it does not require preprocessing and additional memory. Our method is fast since it generates point-primitives from volume dataset during sampling process and it projects the primitives onto the image plane. Also, our method can easily cope with OTF change because we can add or delete point-primitive in real-time.

Accelerating GPU-based Volume Ray-casting Using Brick Vertex (브릭 정점을 이용한 GPU 기반 볼륨 광선투사법 가속화)

  • Chae, Su-Pyeong;Shin, Byeong-Seok
    • Journal of the Korea Computer Graphics Society
    • /
    • v.17 no.3
    • /
    • pp.1-7
    • /
    • 2011
  • Recently, various researches have been proposed to accelerate GPU-based volume ray-casting. However, those researches may cause several problems such as bottleneck of data transmission between CPU and GPU, requirement of additional video memory for hierarchical structure and increase of processing time whenever opacity transfer function changes. In this paper, we propose an efficient GPU-based empty space skipping technique to solve these problems. We store maximum density in a brick of volume dataset on a vertex element. Then we delete vertices regarded as transparent one by opacity transfer function in geometry shader. Remaining vertices are used to generate bounding boxes of non-transparent area that helps the ray to traverse efficiently. Although these vertices are independent on viewing condition they need to be reproduced when opacity transfer function changes. Our technique provides fast generation of opaque vertices for interactive processing since the generation stage of the opaque vertices is running in GPU pipeline. The rendering results of our algorithm are identical to the that of general GPU ray-casting, but the performance can be up to more than 10 times faster.

The Comparison of Image Quality and Quantitative Indices by Wide Beam Reconstruction Method and Filtered Back Projection Method in Tl-201 Myocardial Perfusion SPECT (Tl-201 심근관류 SPECT 검사에서 광대역 재구성(Wide Beam Reconstruction: WBR) 방법과 여과 후 역투영법에 따른 영상의 질 및 정량적 지표 값 비교)

  • Yoon, Soon-Sang;Nam, Ki-Pyo;Shim, Dong-Oh;Kim, Dong-Seok
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.122-127
    • /
    • 2010
  • Purpose: The Xpress3.$cardiac^{TM}$ which is a kind of wide beam reconstruction (WBR) method developed by UltraSPECT (Haifa, Israel) enables the acquisition of at quarter time while maintaining image quality. The purpose of this study is to investigate the usefulness of WBR method for decreasing scan times and to compare to it with filtered back projection (FBP), which is the method routinely used. Materials and Methods: Phantom and clinical studies were performed. The anthropomorphic torso phantom was made on an equality with counts from patient's body. The Tl-201 concentrations in the compartments were 74 kBq (2 ${\mu}Ci$)/cc in myocardium, 11.1 kBq (0.3 ${\mu}Ci$)/cc in soft tissue, and 2.59 kBq (0.07 ${\mu}Ci$)/cc in lung. The non-gated Tl-201 myocardial perfusion SPECT data were acquired with the phantom. The former study was scanned for 50 seconds per frame with FBP method, and the latter study was acquired for 13 seconds per frame with WBR method. Using the Xeleris ver. 2.0551, full width at half maximum (FWHM) and average image contrast were compared. In clinical studies, we analyzed the 30 patients who were examined by Tl-201 gated myocardial perfusion SPECT in department of nuclear medicine at Asan Medical Center from January to April 2010. The patients were imaged at full time (50 second per frame) with FBP algorithm and again quarter-time (13 second per frame) with the WBR algorithm. Using the 4D MSPECT (4DM), Quantitative Perfusion SPECT (QPS), and Quantitative Gated SPECT (QGS) software, the summed stress score (SSS), summed rest score (SRS), summed difference score, end-diastolic volume (EDV), end-systolic volume (ESV) and ejection fraction (EF) were analyzed for their correlations and statistical comparison by paired t-test. Results: As a result of the phantom study, the WBR method improved FWHM more than about 30% compared with FBP method (WBR data 5.47 mm, FBP data 7.07 mm). And the WBR method's average image contrast was also higher than FBP method's. However, in result of quantitative indices, SSS, SDS, SRS, EDV, ESV, EF, there were statistically significant differences from WBR and FBP(p<0.01). In the correlation of SSS, SDS, SRS, there were significant differences for WBR and FBP (0.18, 0.34, 0.08). But EDV, ESV, EF showed good correlation with WBR and FBP (0.88, 0.89, 0.71). Conclusion: From phantom study results, we confirmed that the WBR method reduces an acquisition time while improving an image quality compared with FBP method. However, we should consider significant differences in quantitative indices. And it needs to take an evaluation test to apply clinical study to find a cause of differences out between phantom and clinical results.

  • PDF

Image-based Modeling by Minimizing Projection Error of Primitive Edges (정형체의 투사 선분의 오차 최소화에 의한 영상기반 모델링)

  • Park Jong-Seung
    • The KIPS Transactions:PartB
    • /
    • v.12B no.5 s.101
    • /
    • pp.567-576
    • /
    • 2005
  • This paper proposes an image-based modeling method which recovers 3D models using projected line segments in multiple images. Using the method, a user obtains accurate 3D model data via several steps of simple manual works. The embedded nonlinear minimization technique in the model parameter estimation stage is based on the distances between the user provided image line segments and the projected line segments of primitives. We define an error using a finite line segment and thus increase accuracy in the model parameter estimation. The error is defined as the sum of differences between the observed image line segments provided by the user and the predicted image line segments which are computed using the current model parameters and camera parameters. The method is robust in a sense that it recovers 3D structures even from partially occluded objects and it does not be seriously affected by small measurement errors in the reconstruction process. This paper also describesexperimental results from real images and difficulties and tricks that are found while implementing the image-based modeler.

Unsharp masking based on the vector projection for removing color distortion (색차 왜곡 방지를 위한 벡터투사 기반 언샤프 마스킹 기법)

  • Lee, Kwang-Wook;Dan, Byung-Kyu;Kim, Seung-Kyun;Ko, Sung-Jea
    • Journal of IKEEE
    • /
    • v.13 no.2
    • /
    • pp.224-231
    • /
    • 2009
  • Unsharp masking is a popular image enhancement technique used to sharpen an image appearance in gray images. However, the conventional unsharp making techniques amplify the noise and easily cause overshoot artifacts. Moreover, the unsharp masking tends to introduce color distortion when it is applied to the each color component independently. To solve these problems, we propose a novel unsharp masking technique based on human visual system and vector projection. The proposed algorithm consists of two steps. First, the proposed algorithm controls the level of sharpening by exploiting the characteristics of the human visual system and contrast region. Then the vector projection is applied to remove the color distortion. Experiment results show that our proposed algorithm successfully produces sharpened images that are free of noise and color distortion commonly found in the conventional unsharp masking algorithms.

  • PDF

On the Initial Optimum Step Size for the MPDSAP Adaptive Filter (최대 군위상 분해 부밴드 인접투사 적응필터를 위한 초기 최적 스텝사이즈 해석)

  • Kim, Young-Min;Shon, Sang-Wook;Bae, Hyeon-Deok;Choi, Hun
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.12 no.1
    • /
    • pp.20-25
    • /
    • 2011
  • In subband structure, the fullband AP adaptive filter with P projection dimension can be decomposed P adaptive sub-filters by applying maximally polyphase decomposition and noble identity. Each adaptive sub-filter has a simple weight update formula with the unit projection dimension. This subband decomposition method is one of the most practical solution in the viewpoint of implementation. For utilization in many applications, it is necessary that analysis for the optimum step size of the maximally polyphase decomposed subband AP(MPDSAP) adaptive filter. In this paper, we present an improved analysis model of mean square error and induce the initial optimum step size for the MPDSAP adaptive filter. Computer simulations show that there is a relatively good match between theory and practice for the improved analysis model of MSE and the induced initial optimum step size.

Technology to create a 360-degree panorama of a square room using a single projector and a hemispherical mirror (1대의 프로젝터와 반구형 반사경을 이용한 사각방 360도 파노라마 생성 기법)

  • Lee, Jung-jik;Park, Yoen-yong;Lee, Yun-sang;Lee, Jun-yuep;Jung, Eun-yeong;Yu, Rim;Kang, Myongjin;Jung, Moon-ryul
    • Journal of the Korea Computer Graphics Society
    • /
    • v.26 no.3
    • /
    • pp.133-142
    • /
    • 2020
  • In this research, we describe the method of implementing a 360-degree panorama using one projector, in terms of hardware and in the production of projected pre-distortion images. We propose a method of installing a projector and a reflector on the central ceiling of the space to minimize the shadows generated based on the position of the spectators. We used a virtual camera and virtual space where the projector and hemisphere positions were set to the same as in the exhibition space in Unity. After the image projected on the screen was mapped on the wall of the virtual space, the pre-distortion image was created by the method of capturing from the virtual camera using the ray tracing technique. When the produced pre-distortion image is hemispherical reflected and projected by the projector installed at the same position as the virtual camera, the image is reflected and projected 360 degrees on the panoramic screen.

Luminance Projection Model for Efficient Video Similarity Measure (효율적인 비디오 유사도 측정을 위한 휘도 투영모델)

  • Kim, Sang-Hyun
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.10 no.2
    • /
    • pp.132-135
    • /
    • 2009
  • The video similarity measure is very important factor to index and to retrieve for video data. In this paper, we propose the luminance projection model to measure the video similarity efficiently. Most algorithms for video indexing have been commonly used histograms, edges, or motion features, whereas in this paper, the proposed algorithm is employed an efficient measure using the luminance projection. To index effectively the video sequences and to decrease the computational complexity, we calculate video similarity using the key frames extracted by the cumulative measure, and compare the set of key frames using the modified Hausdorff distance. Experimental results show that the proposed luminance projection model yields the remarkable accuracy and performance than the conventional algorithm.

  • PDF

Improvement of Fourier Transform Arteriography by Use of Ramped RF Profile and Dual Projections (경사 윤곽의 고주파 펄스와 이중 투사법에 의한 Fourier 변환 동맥 혈관 촬영법의 성능 향상)

  • Jung, K. J.;Kim, I. Y.;Lee, M. W.;Yi, Y.
    • Investigative Magnetic Resonance Imaging
    • /
    • v.6 no.1
    • /
    • pp.41-46
    • /
    • 2002
  • The Fourier transform arteriography (FTA) exploits the periodic variation of arterial flow velociety of arterial flow velocity in stnchronized with cardiac cycles. This technique is intrinsically unique compared to other modern techniques. This technique separates the arteries from the veins using the pulsatile arterial flow without using the presaturation RF pulses. Therefore, it has less RF deposition and is free from the dark band artifacts that can arise from retrograde flow and curved arteries. Furthermore, it is free from the artifacts induced by eddy currents. However, there are some drawbacks such as a single projection view and the saturation of arteries at the end of an imaging slab. These drawbacks are circumvented by applying recently developed techniques. The fast gradient switching capability of modern MRI systems enabled us to incorporate dual projection views into the conventional FTA sequence without increasing the repetition time. In addition, signals from the distal arteries were enhanced by use of a ramped RF pulse and therefore the distal arteries were less saturated. By use of the FTA sequence with dual projection views and the ramped RF pulse, we acquired the sagittal and coronal projection views of femoral arteriograms simultaneously with more enhanced signals of distal arteries than the conventional FTA.

  • PDF