• Title/Summary/Keyword: 투과 영상

Search Result 323, Processing Time 0.028 seconds

Study on the Image Quality Comparison between in Digital RT and Film RT (용접부에 대한 디지털 방사선투과영상과 필름 방사선투과영상의 상질 비교에 관한 연구)

  • Park, Sang-Ki;Ahn, Yean-Shik;Gil, Doo-Song
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.31 no.4
    • /
    • pp.391-397
    • /
    • 2011
  • Conventional film radiographic test has been generally and widely used in the inspection on the weldment for quality assurance. On the other hand, since the analog RT is well known for typical time and cost consuming method with complex process of inspection, the industry has researched various ways how to improve radiographic test technology. In this study, we verified the fact that digital RT provides a lot more benefit in effectively detecting defects, ever film details, through digital processing of image enhancement, compared to film RT. As a result, we reached conclusion that digital RT is positively able to replace the film RT in industry in part or in whole.

Registration and Intensity Compensation of Tilted Images of the Mitochondria Section Obtained from the Transmission Electron Microscopy (미토콘드리아 절편의 여러 투사각에서 투과 전자 현미경으로 획득한 영상의 정합과 밝기 보정)

  • Kim, Dong-Sik
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.46 no.3
    • /
    • pp.1-9
    • /
    • 2009
  • Using the projected 2-dimensional tilted images obtained from the transmission electron microscopy, we can reconstruct the 3-dimensional structures of objects, such as cells. As a preprocessing procedure, the tilted images should be registered and compensated in terms of the spatial position and the intensity difference, respectively. In this paper, we employ the fiducial marker-based approach to perform a registration, and introduce a simple intensity compensation scheme. Based on the transmissivity image formation model, we propose an algorithm that can compensate the components of the illumination and transmissivity of each image according to the tilted angle. Numerical analysis using real images obtained from the transmission electron microscopy are shown in this paper to show the performance of the proposed algorithm.

IT융합 UVC대역 코로나방전 영상검출 기술 개발에 관한 연구

  • Jeong, Gyeong-Yeol
    • 기계와재료
    • /
    • v.22 no.2
    • /
    • pp.82-91
    • /
    • 2010
  • 본 연구에서는 전력설비의 절연성능을 주간에도 육안으로 확인 할 수 있도록 태양광에서 지구에 도달하지 못하는 UVC 파장대역을 선택적으로 투과한 코로나 영상과 방전 횟수를 보여주는 시스템을 개발하였다. 선택적인 파장대역을 투과하기 위해 광학계를 개발하였고 광증폭기를 거쳐 나오는 코로나 방전 영상과 가시광 영상을 동시에 확인할 수 있는 영상합성 및 제어기를 개발하여 휴대하기 편리한 코로나 방전 영상시스템을 구축하였다.

  • PDF

Evaluation of Depth Penetration by Changing Image Parameters using Phantom on Ultrasound (의료용 초음파 영상에 영향을 미치는 Algorithm Parameters 변환으로 빔 투과 깊이 연구)

  • Lee Bo Sam;Lim Hyun Soo
    • Journal of The Korean Radiological Technologist Association
    • /
    • v.30 no.1
    • /
    • pp.77-89
    • /
    • 2004
  • I. 목적 : 의료용 초음파 장비의 성능 관리 중 최적 화질의 기본이 되는 심부 투과 깊이에 대해 검증이 미흡한 장비 회사의 protocol setting 값이 현재 대부분의 병원에서 사용되고 있는 실정이다. 이러한 protocol에서 벗어나 국내 여러 모델의 장치에 공통적으로 환자 검사에 실제로 사용하고 있는 algorithm 인 parameters를 사용하여 초음파 영상에 영향을 미치는 빔 투과 깊이의 변화에 따른 최적영상을 평가하고자 한다. II.

  • PDF

Penetration Evaluation for X-ray Images Based on Residual Analysis of Histogram Equalization (히스토그램 평탄화 잔차 분석 기반 X-ray 영상의 투과도 평가 기법)

  • JunYoung Heo;HyeonJin Choi;Dong-Yeon Yoo;Joo-Sung Sun;Jung-Won Lee
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2023.11a
    • /
    • pp.597-598
    • /
    • 2023
  • X-ray는 촬영 방식의 한계로 진단하기 어려운, 품질 낮은 영상을 다수 발생시킨다. 이러한 저품질 영상은 임상 현장에서의 진단이 어려울 뿐만 아니라, 진단 보조 도구를 개발함에 모델의 성능과 신뢰도를 떨어뜨리는 주요 요소가 된다. 특히 투과도가 낮은 영상은 학습 성능에 악영향을 미친다는 것이 입증된 바 있다. 따라서 본 연구는 투과도가 낮은 영상을 진단에 부적합한 영상으로 정의하여, 이를 분류하는 기법을 제안한다. 제안하는 기법은 민감도 94.9%. 특이도 96.0%의 높은 성능을 보였다.

Alzheimer Dementia and Microvascular Pathology: Blood-Brain Barrier Permeability Imaging (알츠하이머 치매와 미세뇌혈관병리: 혈액뇌장벽 투과도 영상)

  • Won-Jin Moon
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.3
    • /
    • pp.488-500
    • /
    • 2020
  • Accumulating evidence suggests that Alzheimer's disease (AD) is not only caused by accumulation of abnormal proteins, including amyloid and tau, but is also closely associated with abnormalities in the microvascular environment including the blood-brain barrier (BBB), both of which lead to neuroinflammation and neurodegeneration. Application of in vivo magnetic resonance imaging (MRI) has recently increased to assess BBB permeability in AD and related diseases. Here, we provide a narrative review of BBB permeability-related pathology in Alzheimer dementia and recent MRI research on BBB permeability changes in AD and related diseases. Furthermore, we briefly introduce the measurement of BBB permeability using MRI and its methodological issues.

An Assessment of Post-Injection Transmission Measurement for Attenuation Correction With Rotating Pin Sources in Positron Emission Tomography (양전자방출단층촬영(PET)에서 회전 핀선원과 투과 및 방출 동시 영상 방법을 이용한 감쇠보정 방법 특성에 관한 고찰)

  • Lee, J.R.;Choi, Y.;Lee, K.H.;Kim, S.E.;Chi, D.Y.;Shin, S.A.;Kim, B.T.
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.4
    • /
    • pp.533-540
    • /
    • 1995
  • Attenuation correction is important in producing quantitative positron emission tomography (PET) images. Conventionally, photon attenuation effects are corrected using transmission measurements performed before tracer administration. The pre-injection transmission measurement approach may require a time delay between transmission and emission scans for the tracer studies requiring a long uptake period, about 45 minutes for F-18 deoxyglucose study. The time delay will limit patient throughput and increase the likelihood of patient motion. A technique lot performing simultaneous transmission and emission scans (T+E method) after the tracer injection has been validated. The T+E method substracts the emission counts contaminating the transmission measurements to produce accurate attenuation correction coefficients. This method has been evaluated in experiments using a cylindrical phantom filled with background water (5750 cc) containing $0.4{\mu}Ci/cc$ of F-18 fluoride ion and one insert cylinder (276 cc) containing $4.3{\mu}Ci/cc$. GE $Advance^{TM}$ PET scanner and Ge-68 rotating pin sources for transmission scanning were used for this investigation. Post-injection transmission scan and emission scan were peformed alternatively over time. The error in emission images corrected using post-infection transmission scan to emission images corrected transmission scan was 2.6% at the concentration of $1.0{\mu}Ci/cc$. No obvious differences in image quality and noise were apparent between the two images. The attenuation correction can be accomplished with post-injection transmission measurement using rotating pin sources and this method can significantly shorten the time between transmission and omission scans and thereby reduce the likelihood of patient motion and increase scanning throughput in PET.

  • PDF

Usefulness of Permeability Map by Perfusion MRI of Brain Tumor the Grade Assessment (뇌종양의 등급분류를 위한 관류 자기공명영상을 이용한 투과성영상(Permeability Map)의 유용성 평가)

  • Bae, Sung-Jin;Lee, Joo-Young;Chang, Hyuk-Won
    • Journal of radiological science and technology
    • /
    • v.32 no.3
    • /
    • pp.325-334
    • /
    • 2009
  • Purpose : This study was conducted to assess how effective the permeability ratio and relative cerebral blood volume ratio are to tumor through perfusion MRI by measuring and reflecting the grade assessment and differential diagnosis and the permeability and relative cerebral blood volume of contrast media plunged from blood vessel into organ due to breakdown of blood-brain barrier in cerebral. Subject and Method : Subject of study was 29 patients whose diagnosis were confirmed by biopsy after surgery and 550 (11 slice$\times$50 image) perfusion MRI were used to make image of relative cerebral blood volume with the program furnished on instrument. The other method was to transmit to private computer and the image analysis was made additionally by making image of relative cerebral blood volume-reformulated singular value decomposition, rCBV-rSVD and permeability using IDL.6.2. In addition, Kruskal-wallis test tonggyein non numerical average by a comparative analysis of brain tumors Results : The rCBV ratio (Functool PF; GE Medical Systems and IDL 6.2 program by analysis) and permeability ratio of tumors were as follows; high grade glioma(n=4), (14.75, 19.25) 13.13. low grade astrocytoma(n=5) (14.80, 15.90) 11.60, glioblastoma(n=5) (10.90, 18.60), 22.00, metastasis(n=6) (11.00, 15.08). 22.33. meningioma(n=6) (18.58, 7.67), 5.58. oliogodendroglioma(n=3) (23.33, 16.33, 15.67. Conclusion : It was not easy to classify the grade with the relative cerebral blood volume ratio measured by using the relative cerebral blood image by type of tumors, however, permeability ratio measured by permeability image revealed that the higher the grade of tumor, the higher the measured permeability ratio, showing the assessment of tumor grade is more effective to differential diagnosis.

  • PDF

Impact of Contrast agent for Attenuation Correction Using CT Scan in PET/CT System (PET/CT 시스템에서 CT 영상을 이용한 감쇠 보정 시 조영제가 PET 영상에 미치는 영향)

  • Son, Hye-Kyung;Turkington, Timothy G;Kwon, Yun-Young;Bong, Jung-Kyun;Jung, Hai-Jo;Kim, Hee-Joung
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2004.11a
    • /
    • pp.100-103
    • /
    • 2004
  • Experiments and simulation were done to study the impact of contrast agent when CT scan was used to attenuation correction for PET images in PET/CT system. Whole body phantom was imaged with various concentration of iodine-based contrast agent using CT. Mathematical emission and transmission density map with liver were made to simulate for whole body FDG imaging. Various transmission density maps was generated with non-uniform enhancement of contrast agent, hypo-attenuating of contrast agent for tumor, different concentration of contrast agent, and so on. Attenuation correction was done with all transmission maps. In the experiments, we confirmed that attenuation coefficient was changed by concentration of contrast agent. From the simulation data, image quality of attenuation corrected images was affected by contrast agent and artifact was produced by contrast agent. These results indicated that the contrast agent should be used with a full understanding of its potential problem in PET/CT system.

  • PDF

Evaluation of Image Uniformity and Radiolucency for Computed Tomography Phantom Made of 3-Dimensional Printing of Fused Deposition Modeling Technology by Using Acrylonitrile Butadiene Styrene Resin (아크릴로나이트릴·뷰타다이엔·스타이렌 수지와 용융적층조형 방식의 3차원 프린팅 기술로 제작된 전산화단층영상장치 팬톰에서 영상 균일성 및 X선 투과성 평가)

  • Seoung, Youl-Hun
    • Journal of radiological science and technology
    • /
    • v.39 no.3
    • /
    • pp.337-344
    • /
    • 2016
  • The purpose of this study was to evaluate the radiolucency for the phantom output to the 3D printing technology. The 3D printing technology was applied for FDM (fused deposition modeling) method and was used the material of ABS (acrylonitrile butadiene styrene) resin. The phantom was designed in cylindrical uniformity. An image uniformity was measured by a cross-sectional images of the 3D printed phantom obtained from the CT equipment. The evaluation of radiolucency was measured exposure dose by the inserted ion-chamber from the 3D printed phantom. As a results, the average of uniformity in the cross-sectional CT image was 2.70 HU and the correlation of radiolucency between PMMA CT phantom and 3D printed ABS phantom is found to have a high correlation to 0.976. In the future, this results will be expected to be used as the basis for the phantom production of the radiation quality control by used 3D printing technology.