• Title/Summary/Keyword: 통풍공

Search Result 29, Processing Time 0.024 seconds

A Study on the Characteristics of Forced Draft Cooling Tower (강제통풍식 냉각탑 특성에 관한 연구)

  • Seoh, Jeong-Il;Kim, Kwang-Soo;Lee, Young-Soo
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.13 no.2
    • /
    • pp.1-9
    • /
    • 1984
  • This paper presents design conditions due to the NTU of counter and cross flow type cooling tower. In the calculation of optimum design conditions for above two types which are widely used in our country, standard water-air ratio, ambient wet bulb temperature and bulk water temperature were adopted by domestic wheather conditions. The important result of this study is obtained as follows : Under the constant value of Ka and L, the number of transfer unit of cross flow type cooling tower Is about 1.1 times as large as that of counter, so the volume of cross flow type is about $10\%$ greater than that of counter.

  • PDF

Draft of Flue Gas in a Briquette Combustion (연탄연소가스유로의 통풍력)

  • Youm Dong-Soo
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.7 no.4
    • /
    • pp.227-238
    • /
    • 1978
  • Draft of the conbustion gab burning in a briquette gives a great part of driving force to the flue gas in an Korean conventional ondol heating system. The Paper present s how the draft intensity varies for each whole Combustion duration. In this experiment the temperatures of thirty spots In three gas courses of a briquette were measured and the drafts were calculated form those experimental data. The result is that the shorter the combustion duration of a briquette is, the stronger the draft becomes, the intensity of drafts ranging between 0.15mm Aq to 0.26mm Aq.

  • PDF

Study on the Flow of Briquette Gas in the Ondol Heating System (Chimney Draft of Low Temperature Moist Air) (온돌의 연탄개스유량에 관한 연구(1) (함습저온열기류의 굴뚝통풍력))

  • Min Man-Ki
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.4 no.2
    • /
    • pp.119-128
    • /
    • 1975
  • Natural draft and flow which low temperature moist gas produces in the chimney of an Ondol heating system were numerically analysed. Among several factors involved inlet gas temperature has the strongest influence on the chimney performance and then next specific humidity of the gas. Thermal conductivity of the chimney wall, however, has little influence on the performance of such a low temperature chimney. Under given flow conditions there exists an optimum chimney height which gives a maximum flow rate for a given chimney diameter. This optimum value of chimney height inereases with increase in chimney diameter, inlet gas temperature and specific humidity.

  • PDF

Study on Development of air-passing soundproofing panel (통풍형 방음벽 개발에 관한 연구 I)

  • Yoon, Je-Won;Sim, Sang-Deok;Kim, Young-Chan;Ku, Bon-Sung;Eom, Joo-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.638-643
    • /
    • 2011
  • The aluminum soundproofing panel used to the traffic noise reduction will judge with the material to improve because the CO2 emission is greater than other soundproofing panel such as plastic soundproofing panel. Also, if the air-passing soundproofing panel which can endure the fast wind velocity will be developed, it judged that it can reached to the target of low CO2 traffic technology development using the reduction of material cost and the lower consumption of steel. The objective of this study is to improve the soundproofing panel and to develop the air-passing soundproofing panel for the replacement of aluminum sound proofing panel which is more emit CO2 than other soundproofing panel. And, we tried to develop the reduction technology of CO2 emission through the development of air-passing soundproofing panel. At first, the flow and noise simulation were conducted for the purpose of the calculation of wind pressure on soundproofing wall and noise exposure level on receiver points according to the open ratio of air-passing soundproofing panel. And the 1st and 2nd mockup of air-passing soundproofing panel were made, and the design load test were conducted for these mockup.

  • PDF

The Improvement of The Exterior Air Flow Environment in The Inner Curved Area of Tower Type Apartment (탑상형 아파트 만곡부의 외부 통풍환경 개선에 대한 연구)

  • Chang, Hyun-Jae;Kim, Hyung-Jin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.1
    • /
    • pp.61-69
    • /
    • 2012
  • Recently, tower type apartment has been a main stream at the apartment market, in Korea. Tower type apartment has features that is easy to maintain a proper distance between apartment buildings, and to keep a prospect comparing to flat type apartment However, there is usually a inner curved area at tower type apartment, and it is able to make an unhealthy environment because of shaded area through a day and a bad air flow. In this study, the duration of sunshine and the exterior air flow environments are examined. As results, the duration of sunshine at the inner curved area of tower type apartment was extremely short, and the exterior air flow environment was very bad for the low air velocity of about 0.08m/s. Installing pilotis in the 1st floor which faces to the inner curved area makes the good improvement of exterior air flow environment.

A Study on Indoor Thermal Environment in an Tower Type Apartment House at Tropical Nights (여름철 열대야 발생시 탑상형 아파트의 실내온열환경에 대한 연구)

  • Chang, Hyun-Jae;Kim, Hyung-Jin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.1
    • /
    • pp.20-25
    • /
    • 2010
  • In this study, As a basic research for improving indoor thermal environment at tower type apartment houses, specifications of heat storage and heat emission in the structures of apartment houses were investigated, and the ratio of indoor and outdoor air velocity at tower type apartment house was examined, too. Indoor temperature at night time was higher than outdoor air temperature because heat emission from the structure of wall, ceiling and floor those are constructed by use of reinforced concrete which has large heat capacity. The ratio of indoor and outdoor air velocity was lower than 0.1 and this was caused by the plan of tower type apartment house. PMV was in the range of 0.3~1.9, and was about 1.0 (it means slightly warm) at 10 : 00 p.m.. To improve indoor thermal environment in summer season at tower type apartment houses, it needs more investigation on specifications of heat storage and heat emission in the structure including winter season, and on the improvement of the ratio of indoor and outdoor air velocity.

Numerical Study on the Flow Characteristics according to the Ventilation Holes Shape of the Carbon Composite Brake Disk (탄소복합재 브레이크 디스크의 통풍구 형상에 따른 유동특성에 관한 해석적 연구)

  • Ko, Dongguk;Yoon, Suckju
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.23 no.2
    • /
    • pp.191-198
    • /
    • 2015
  • In this study, the flow characteristics at the ventilation holes was analyzed by using numerical method when carbon composite brake disk was rotated at a constant speed. In order to ensure the validity of the analysis results, grid dependency test was performed by considering the accuracy and appropriateness, and 4mm mesh size was selected for decrease of the maximum error rate 63.6%. As a result, the outside air flows in the clearance between the disk and shaft in case of B model. whereas, the outside air flows in the clearance or the outlet of the ventilation holes in case of A and C models. And also average static pressure at the outlet was changed depending on shape of the ventilation holes and rotational speed of the disk in case of A and C models. Besides, in the B model, intake air according to the clearance goes with side surface of ventilation hole, and so increased by mean velocity of 4.64m/s and mean pressure of 0.58pa in the ventilation hole outlet, in case of disk rotational speed of 146.21rad/s.

A Study on the development and application of air-passing soundproofing wall (통풍형 방음벽 개발 및 적용에 관한 연구)

  • Yoon, Je-Won;Kim, Young-Chan;Kim, Keum-Mo;Jang, Kang-Seok;Ku, Bon-Sung;Eom, Joo-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.10a
    • /
    • pp.658-663
    • /
    • 2011
  • The purpose of this study is to develop an air-passing soundproofing panel with more improved structure to reduce the $CO_2$ emission and installation cost. To reduce the emission of $CO_2$ ; it is suggested to choose low $CO_2$ emission material relative to the aluminum and to reduce the materials by developing a specially designed air-passing soundproofing panel structure. First of all, we performed the flow analysis to predict the wind pressure according to the open angle of the air-passing soundproofing panel and the noise level analysis at the receiver point. To verify the simulation, a prototype of the soundproofing panel was made. The flow test in the wind tunnel and load test were performed. The economic evaluation for the installation of the air-passing soundproofing panel was performed and specifications of the installation was prepared. As the results of this research, it was verified that the wind load was reduced about 40% to that of the conventional one at 25m/s wind speed in the wind tunnel test. By applying the 4m span soundproofing wall with air-passing soundproofing panel and under the cost of 250 thousand $won/m^2$ instead of the conventional 2m span panel, the installation cost will always be lowered than the conventional one in the combination of (60:40~50:50) conventional to air-passing soundproofing panel from the economic evaluation. The 20% reduction of $CO_2$ was found by changing the 50% of aluminum soundproof panel to air-passing soundproofing panel.

  • PDF

Status of Soil Remediation and Technology Development in Korea (국내 오염토양 복원 현황과 기술 동향)

  • Yang, Ji-Won;Lee, You-Jin
    • Korean Chemical Engineering Research
    • /
    • v.45 no.4
    • /
    • pp.311-318
    • /
    • 2007
  • Soil contamination in Korea has been accelerated every year. Because of their persistence and cumulative tendency in the environment, soil contaminants have potential long-term environmental and health concerns and it is estimated to cost enormous expense for clean-up. Korea government has legislated the law on conservation of soil environment in mid 1990s, and managed and treated hazardous wastes in contaminated sites as a remediation policy since then. Soil remediation technologies are classified into in-situ/ex-situ or biological/physico-chemical/thermal processes according to applied places or treatment methods, respectively. In Korea, clean-up of polluted sites has been mostly carried out at military areas, railroad-related sites and small-scale oil spilt sites. For these cases, in-situ remediation technologies such as soil vapor extraction (SVE) and bioventing were mainly used. In recent days, an environmental-friendly soil remediation emerged as a new concept - for example, a new soil remediation process using nanotechnology or molecular biological study and an integrated process which can overcome the limitation of individual process. To have better applicability of remediation technologies, comprehensive understandings about the pollutants and soil characteristics and the suitable techniques are required to be investigated. Above all, development of environmental technologies based on the sustainability accompanied by public attention can improve soil environment in Korea.