Analysis and Design of FRT Detection System Using PMU (PMU를 사용한 FRT 검출시스템 설계 및 분석)

  • Kwon, Dae-Yun;Moon, Chae-Joo;Jeong, Moon-Seon;Yoo, Do-Kyeong
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.16 no.4
    • /
    • pp.643-652
    • /
    • 2021
  • Accidents or faults in the transmission and distribution system are never completely avoidable, and short-circuit and earth faults are occurs despite the efforts of the TSO and DSO. Recently, the connection to the transmission and distribution system of large-capacity new and renewable distributed power has increased rapidly and has various effects on the operation of the system. In order to minimize this, connection standards such as FRT (Fault-Ride-Through) have been established to provide wind turbines or solar inverters. In the event of a major faults of the power system, the operation support shall be provided so that the operator can stably operate the system by smoothly performing connection maintenance or rapid system separation. In this paper, in order to appropriately determine whether the FRT condition, which is the grid connection criterion for a representative DERs, is sufficient, a detection system using a PMU (Phasor Measurement Unit) that measures a synchro-phasors was designed and deployment and a system accident due to a generator step-out to analyze and evaluate the proposed system based on the case.

A Study on the Correction of Protection Relay of Temporary Electric Power Installations for Storage Tank (저장 탱크용 임시전력설비의 보호계전기 정정에 관한 연구)

  • Son, Seok-Geum
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.13 no.6
    • /
    • pp.562-567
    • /
    • 2020
  • In this paper, this is a study on the correction of protection relays to monitor temporary power facilities for storage tanks especially transformers to block and protect faults such as insulation breakdown. When an abnormality such as a short circuit or a ground fault occurs in the power system, it is important to detect this quickly cut off the device and equipment in which the fault occurred and separate it from the power system to correct the protection relay so that it does not interfere with power supply. In addition the fault current calculation that accurately applies the fault type and the cause of the fault for protection cooperation will be the most important factor in the correction of the protection relay. For protection coordination a study was conducted on the method of coordination for protection of power facility protection for storage tanks such as over current relay, ground over current relay, under voltage relay, and ground over voltage relay applied to temporary.

Estimation of Motor Deterioration using Pulse Signal and Insulation Resistance Measurement Algorithm (펄스 신호 및 절연저항 측정 알고리즘을 이용한 전동기 열화 추정)

  • Jeong, Sungin
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.22 no.5
    • /
    • pp.111-116
    • /
    • 2022
  • The causes of motor burnout include overload, phase loss, restraint, interlayer short circuit, winding ground fault, instantaneous overvoltage, and the rotor contacting the stator, leading to insulation breakdown, leading to breakdown or electrical accidents. Therefore, equipment failure causes not only loss due to cost required for equipment maintenance/repair, but also huge economic loss due to productivity decrease due to process stop because the process itself including the motor is stopped. The current level of technology for diagnosing motor failures uses vibration, heat, and power analysis methods, but there is a limit to analyzing the problems only after a considerable amount of time has passed according to the failure. Therefore, in this paper, a device and algorithm for measuring insulation resistance using DC AMP signal was applied to an industrial motor to solve this problem. And by following the insulation resistance state value, we propose a diagnosis of deterioration and failure of the motor that cannot be solved by the existing method.

Design of Reconfigurable Dual Polarization Patch Array Antenna (재구성 이중편파 패치 배열 안테나 설계)

  • Won Jun Lee;Young Jik Cha
    • Journal of Advanced Navigation Technology
    • /
    • v.27 no.4
    • /
    • pp.463-468
    • /
    • 2023
  • In this paper, we proposed reconfigurable dual polarization patch array antenna that can select two polarizations(Vertical, RHCP) using defected ground structure and Pin diode. The proposed antenna was designed arranging a circular polarization patch antenna implemented with a square microstrip patch and two slots 3x3 at 25.8mm placed, a half-wavelength of 5.8 GHz. Conect the pin diode and the capacitor to the slot diagonally placed on the ground of each antennas, and select polarization using the open/short operating according to the application of DC voltage to the pin diode. As a result of the design, the gain of the antenna is 11.7 dBi at vertical polarization and 11.6 dBic at RHCP. The axial ratio is 20.3 dB at 1.8 dB vertical polarization at RHCP. Mutual Coupling is Maximum to -20.8 dB for vertical polarization and Maximum to -30.1 dB for RHCP.

Design of a High-Performance Match-Line Sense Amplifier for Selective Match-Line charging Technique (선택적 매치라인 충전기법에 사용되는 고성능 매치라인 감지 증폭기 설계)

  • Ji-Hoon Choi;Jeong-Beom Kim
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.18 no.5
    • /
    • pp.769-776
    • /
    • 2023
  • In this paper, we designed an MLSA(Match-line Sense Amplifier) for low-power CAM(Content Addressable Memory). By using the MLSA and precharge controller, we reduced power consumption during CAM operation by employing a selective match-line charging technique to mitigate power consumption caused by mismatch. Additionally, we further reduced power consumption due to leakage current by terminating precharge early when a mismatch occurs during the search operation. The designed circuit exhibited superior performance compared to the existing circuits, with a reduction of 6.92% and 23.30% in power consumption and propagation delay time, respectively. Moreover, it demonstrated a significant decrease of 29.92% and 52.31% in product-delay-product (PDP) and energy-delay-product (EDP). The proposed circuit was validated using SPECTRE simulation with TSMC 65nm CMOS process.

Review of Typical Fault Current Limiter Types and Application Effect to Improve Power System Reliability (전력 계통 신뢰도 개선을 위한 대표적인 한류기 유형 및 적용 효과 분석)

  • Yun-Seok Ko;Woo-Cheol Lee
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.18 no.6
    • /
    • pp.1133-1142
    • /
    • 2023
  • A rapid increase in power capacity in a power system can seriously reduce system reliability by causing the fault capacity to exceed the breaking capacity of circuit breaker. Fault current limiter is a practical and effective way to improve reliability by limiting fault capacity to the breaking capacity level. In this study, in order to help develop an application methodology when applying fault current limiters to power systems, first the topology and operating principles of each type of fault current limiters was reviewed, and the main advantages and disadvantages was compared. Next, to verify the effect of applying fault current limiter to the power system, the power system in which the fault current limiter was introduced was modeled. Finally, after simulating a three-phase short-circuit fault using EMTP-RV, the effect of application was verified by comparing the fault current before and after application of the fault current limiter and confirming that the fault current was reduced by the fault current limiter.

Fault Location Estimation Algorithm in the Railway High Voltage Distribution Lines Using Flow Technique (반복계산법을 이용한 철도고압배전계통의 고장점표정 알고리즘)

  • Park, Kye-In;Chang, Sang-Hoon;Choi, Chang-Kyu
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.2
    • /
    • pp.71-79
    • /
    • 2008
  • High voltage distribution lines in the electric railway system placed according track with communication lines and signal equipments. Case of the over head lines is occurrence the many fault because lightning, rainstorm, damage from the sea wind and so on. According this fault caused protection device to wrong operation. One line ground fault that occurs most frequently in railway high voltage distribution lines and sort of faults is line short, three line ground breaking of a wire, and so on. For this reason we need precise maintenance for prevent of the faults. The most important is early detection and fast restoration in time of fault for a safety transit. In order to develop an advanced fault location device for 22.9[kV] distribution power network in electric railway system this paper deals with new fault locating algorithm using flow technique which enable to determine the location of the fault accurately. To demonstrate its superiorities, the case studies with the algorithm and the fault analysis using PSCAD/EMTDC (Power System Computer Aided Design/Electro Magnetic Transients DC Analysis Program) were carried out with the models of direct-grounded 22.9[kV] distribution network which is supposed to be the grounding method for electric railway system in Korea.

Development of a Acoustic Acquisition Prototype device and System Modules for Fire Detection in the Underground Utility Tunnel (지하 공동구 화재재난 감지를 위한 음향수집 프로토타입 장치 및 시스템 모듈 개발)

  • Lee, Byung-Jin;Park, Chul-Woo;Lee, Mi-Suk;Jung, Woo-Sug
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.22 no.5
    • /
    • pp.7-15
    • /
    • 2022
  • Since the direct and indirect damage caused by the fire in the underground utility tunnel will cause great damage to society as a whole, it is necessary to make efforts to prevent and control it in advance. The most of the fires that occur in cables are caused by short circuits, earth leakage, ignition due to over-current, overheating of conductor connections, and ignition due to sparks caused by breakdown of insulators. In order to find the cause of fire at an early stage due to the characteristics of the underground utility tunnel and to prevent disasters and safety accidents, we are constantly managing it with a detection system using image analysis and making efforts. Among them, a case of developing a fire detection system using CCTV-based deep learning image analysis technology has been reported. However, CCTV needs to be supplemented because there are blind spots. Therefore, we would like to develop a high-performance acoustic-based deep learning model that can prevent fire by detecting the spark sound before spark occurs. In this study, we propose a method that can collect sound in underground utility tunnel environments using microphone sensor through development and experiment of prototype module. After arranging an acoustic sensor in the underground utility tunnel with a lot of condensation, it verifies whether data can be collected in real time without malfunction.

Design of a TM31 Higher Order Mode Half Circular-Ring Microstrip Patch Antenna for On-Body Communications (인체 표면 통신을 위한 TM31 고차 모드 반원-링 인체 부착형 마이크로스트립 패치 안테나 설계)

  • Tak, Jinpil;Jeon, Jaesung;Kim, Sunwoo;Choi, Jaehoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.5
    • /
    • pp.491-503
    • /
    • 2014
  • In this paper, a $TM_{31}$ higher order mode half circular-ring microstrip antenna with monopole-like radiation characteristic for on-body communication is proposed. By using shorting vias, $TM_{31}$ resonance mode was excited, while achieving compact low-profile antenna with monopole-like radiation characteristics. To overcome the narrow bandwidth of a patch antenna, a C-shape half ring patch with shorting vias having $TM_{31}$ mode is closely located around a half circular patch. For size reduction, half mode is adopted. The proposed antenna has the overall dimensions of $0.25{\lambda}_0{\times}0.46{\lambda}_0{\times}0.025{\lambda}_0$ at the industrial, scientific, and medical(ISM) 2.45 GHz band(2.4~2.485 GHz) and the 10-dB return loss is 4.24 % ranging from 2.38 to 2.49 GHz. To verify body effect, two-thirds muscle equivalent semi solid phantom was fabricated and used to measure the antenna performance. A communication link is analysed to investigate the effect of human-body movements and antenna locations.

ISC-STS Proposal for Reliability Improvement of Communication System's (통신용 전원공급 신뢰성 증진을 위한 ISC-STS 제안)

  • Jung, Hyun-Chul;Hyun, Dong-Seok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.13 no.5
    • /
    • pp.383-390
    • /
    • 2008
  • The SCR in Static Transfer Switch (STS) is used for reliability improvement of important load's power supply in industry field. However an average of 2% fault in thyristor(SCR) occurs, so that the attached mechanical switch is paralleled with SCR's both end points and SCR operates only during the $12{\sim}208$[mS] before operation of the mechanical switch. Also, an ISC (Ideal State Conditioning Interlock Device) - STS system that two power supply paths may not be thrown at the same time is developed to remove the overlap section perfectly when a short or earth fault is generated in one system. This method has reduced the fault rate remarkably through the reduction of SCR's fatigue degree by using SCR in conversion operation corresponding to 0.89 times a year. Also, in case of fault generations, it does not affect to supply power to the load, therefore it contributes to the promotion of reliability in the power supply.