• Title/Summary/Keyword: 통과시간

Search Result 927, Processing Time 0.04 seconds

Development of a New Terrain Type Classification to be used in Highway Design (도로설계 적정화를 위한 새로운 지형구분에 관한 연구)

  • Kim, Sang-Youp;Choi, Jai-Sung;Lee, Seung-Yong;Han, Hyung-Gwan
    • International Journal of Highway Engineering
    • /
    • v.8 no.4 s.30
    • /
    • pp.49-62
    • /
    • 2006
  • The republic of korea has put a great emphasis on the role of the road as widening a social infra-structural facility. Thus, vast amount of money has been invested on the road establishment. As a result, there has been fruitful outcomes in establishing the road system of the nation especially for the flat road with ease. However, in order to have more systematic and sustainable road system, we should turn our attention to more painful and high-cost regions such as mountainous districts and those are to be developed effectively. The configuration of the road is an important factor to be considered in making a decision for the road planning. Nevertheless, current road planning criterion has no such clarified and objective judging standard for figuring the configuration of the road out and, as a result, speed planning can be decided incorrectly. our research has acknowledged the necessity of estimating the configuration of the road and aimed to make it organized and sorted according to the height, slope, and the vehicle's speed. The results are as follows. First, our research made use of GIS data and classified the road into 9 different areas according to the height and the slope. Also, road classification being matched to the data of vehicle's speed, it has been shown that those characteristics of different areas have made an influence on vehicle's speed. Secondly, based on the results of the similarity between geographical classification and, vehicle's speed of sorted groups according to the height and the slope, conclusively we have classified as flat, rolling region and mountain. Since our research has made use of vehicle's speed for National Highway, it is not applicable to different functional highways. However, for the highway to be established hereafter, it can be a standard for reflection geographical characteristics.

  • PDF

Distribution and Characteristics of Heterotrophic Plate Count Bacteria in Water Samples from Drinking Water Dispensers (냉온수기에서 일반세균의 분포 및 분리한 세균의 특성)

  • Lee, Eun-Hwa;Koh, Ji-Yun;Kim, Jong-Seol
    • Korean Journal of Microbiology
    • /
    • v.44 no.3
    • /
    • pp.244-250
    • /
    • 2008
  • To evaluate bacteriological water quality, samples were taken from drinking water dispensers placed at S company (S-C) and U highschool (U-H) in Ulsan. The medians of heterotrophic plate counts (HPCs) were 53 CFU/ml for the 74 water samples of S-C and 80 CFU/ml for the 36 cold water samples of U-H, and 38% of the S-C and 42% of the U-H samples showed HPC bacterial concentrations higher than 100 CFU/ml. Coliform bacteria were detected from one sample of S-C. To determine the major source of bacterial contamination, water samples were taken daily for $6\sim8$ days from the bottled water containers as well as the faucets of an experimental water dispenser. While the average HPCs in the bottled water containers were 33 CFU/ml for the first and 132 CFU/ml for the 2nd analysis, the HPC concentration in the cold water samples was 1,022 CFU/ml for the 2nd analysis. These results suggest that the majority of bacteria detected in the cold water samples were originated from the biofilms on the surface of water passages within the water dispensers. There was no significant increase in HPC bacterial concentrations within the bottled water container after installation on the water dispenser. We could isolate and tentatively identify 3 genera 6 species of Gram-positive and 7 genera 7 species of Gram-negative bacteria from the plate count agar plates of U-H samples. Among the isolates, 72% were observed as Gram-positive, and Micrococcus spp. was the most abundant with 54% of the total, followed by Sphingomonas paucimobilis with 16%. It appears that most of the HPC bacteria detected in water dispensers originate from indoor airborne bacteria, which may play important roles in the formation of biofilms on the surface of water passages within the water dispensers.

Characterization of an Ion Channel Prepared from Tomato Roots and Inhibitory Effects by Heavy Metal Ions (토마토 뿌리조직에서 분리한 이온채널의 중금속에 의한 저해)

  • Shin, Dae-Seop;Han, Min-Woo;Kim, Young-Kee
    • Applied Biological Chemistry
    • /
    • v.47 no.4
    • /
    • pp.390-395
    • /
    • 2004
  • In order to characterize ion channels present in tomato roots, microsomes were incorporated into an artificial lipid bilayer arranged for electrophysiological analysis. Of the five different ion channels that could be found, a channel of 450 pS conductance was found most frequently. This channel displayed subconductance states of 450, 257 and 105 pS. All subconductance states showed linear current-voltage relationships. At positive holding potentials, high frequency of transient channel openings was observed; however, at negative potentials, the open times were long and open probability high. Po was 0.83 at -40 mV. When an additional 50 mM $K^+\;or\;Na^+$ was added to the cis side of bilayer, the reversal potentials shifted in the negative direction to near -10 mV. Thus, the 450 pS cation channel selects poorly between $K^+\;and\;Na^+$. In the presence of $100\;{\mu}M$ metal ions, the channel activity was severely inhibited by $La^{3+},\;Ba^{2+},\;and\;Zn^{2+}$, and Po was decreased to 0.2 or even less. However, $Al^{3+}\;and\;Cd^{2+}$ decreased the activity by only 20%. Interestingly, each metal ion showed different kinetics of channel inhibition. While $500\;{\mu}M\;La^{3+}$ inhibited the activities of all subconductance state, 1 mM $Zn^{2+}$ inhibited all except the 105 pS state. $Cd^{2+}$ changed the gating of the channel from a long-opening state to brief transient openings even at negative holding potentials. These data represent that the metal ions may have different binding sites on the channel protein and could be useful modulators and probes to investigate structural characteristics as well as the functional roles of the 450 pS channel on the root physiology.

Interdecadal Variation of Tropical Cyclone Genesis Frequency over the Western North Pacific (북서태평양에서 열대 저기압 발생빈도의 십년간 변동 특성)

  • Choi, Ki-Seon;Kim, Baek-Jo;Lee, Seong-Lo;Park, Jong-Kil
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.9 no.6
    • /
    • pp.31-39
    • /
    • 2009
  • This study has found that there is a reverse phase with interdecadal variation in temporal variations of tropical cyclone (TC) genesis frequency (TCGF) between Northwest sector and Southeast sector, based on climatological mean tropical cyclone genesis location over the western North Pacific. The TCGF in the Northwest sector has been increased since the mid 1980s (1986-2005), while TCGF in the Southeast sector was higher until the early 1970s (1951-1970). The analysis of a difference between 1986-2005 and 1951-1970 showed results as follows: i) Through the analysis of vertical wind shear (VWS) and sea surface temperature (SST), less VWS and higher SST in the former (latter) period was located in the Northwest (Southeast) sector. ii) In the analysis of TC passage frequency (TCPF), TCs occurred in the Northwest sector frequently passed from east sea of the Philippines, through East China Sea, to Korea and Japan in the latter period, while TCs in the former period frequently has a lot of influences on South China Sea (SCS). In the case of TCs occurred in the Southeast sector, TCs in the west (east), based on $150^{\circ}E$ had a high passage frequency in the latter (former) period. In particular, TCs during the latter period frequently moved toward from the east sea of the Philippines to SCS and southern China. iii) This difference of TCPF between the two periods was characterized by 500 hPa anomalous pressure pattern. Particularly, anomalous cyclonic circulation strengthened over the East Asian continent caused anomalous southerlies along the East Asian coast line from the east sea of the Philippines to be predominate. These anomalous winds served as steering flows that TC can easily move toward same regions.

The Electrochemical Chlorination for Marine Plankton Community Disinfection (해양 플랑크톤 군집의 전기분해 염소소독 효과)

  • Kang, Jung-Hoon;Shin, Kyoung-Soon;Hyun, Bong-Gil;Jang, Min-Chul;Kim, Eun-Chan;Chang, Man
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.10 no.3
    • /
    • pp.127-137
    • /
    • 2007
  • To confirm whether or not the Electrochemical Disinfection System (EDS) meet with the D-2 regulation established by IMO (International Maritime Organization), the biological treatment efficacy of the EDS was assessed using three groups of natural marine plankton (bacteria, $10-50\;{\mu}m$ and $>50\;{\mu}m$ sized organisms). Influent water was passed through the EDS under the flow velocity ($23.8\;m^3/hr$) and test design was consisted of control (no treatment) and experimental (10 ppm and 30 ppm) condition for total residual chlorine (TRC). And the biological condition of the influent water followed the standards established by the guidelines for the approval of ballast water management systems. The disinfection efficacy of the $10-50\;{\mu}m$ sized organisms (phytoplankton) was assessed by three kinds of measurements using photomicroscope, epifluorescence microscope and fluorometer (fumer Designs 10-AU). After being passed through the EDS, all motile phytoplankton lost their motility under photomicroscope, the colour of chlorophyll fluorescence fumed from red into green under epifluorescence, and the high chlorophyll fluorescence (Expt. 1: 6.95, Expt. 2: 7.11) detected by fluorometer decreased into value not detected. These results indicated phytoplankton community was totally killed after electrochemical disinfection treatment. Survivorship of the larger organisms than $50\;{\mu}m$ was determined based on the appendage's movement under a stereomicroscope. Natural assemblage collected from ambient seawater was killed shortly after being passed through the EDS, whereas some Artemia remained alive. However, no live Artemia was found after 24 hour further exposure to each TRC concentration (10 and 30 ppm) under darkness. After electrochemical treatment, the target bacteria such as aerobes, coliform and Escherichia coli were completely killed on the basis of CFU (colony forming unit) on Petrifilm plate ($3\;M^{TM}$) after 48 hr incubation. Moreover, no regrowth was found in the three groups of plankton during five days under additional exposure to the treated water. These results indicated that the disinfection efficiency of the EDS on the three groups of plankton satisfy D-2 regulation.

  • PDF

Effect of Internal Organs of Todarodes pacificus Extracts on Blood Rheological Properties and Serum Lipid Concentration (오징어 부산물이 혈액 유동성 및 혈중 지질 농도에 미치는 영향)

  • Kang, Sung-Rim;Lee, Sang-Hyeon;Bae, Song-Ja;Park, Mi-Ra;Park, Joung-Hyun;Kim, Mi-Hyang
    • Journal of Life Science
    • /
    • v.20 no.1
    • /
    • pp.90-96
    • /
    • 2010
  • Menopause increases the onset of hypertension and heart disease. Whereas it increases the blood LDL-cholesterol, triglyceride and total-cholesterol levels, the HDL-cholesterol concentration is reduced. Accordingly, we examined the effect of internal organs of Todarodes pacificus (IOT) on improvement in blood flow ability and changes in serum lipid content by using ovariectomized rats. For this study, the following four groups of 9-week-old Sprague-Dawley strain female rats were evaluated over 6 weeks: normal rats (SHAM), ovariectomized rats (CON) and ovariectomized rats that were treated with IOT extracts. Ovary removal promoted platelet aggregability. However, IOT administration in the CON group after ovary excision resulted in a hinderance of coherence. The blood vessel passing time of ovariectomized rats was slower than the SHAM group. But the blood flow ability, which was slowed down for ovary removal, was improved by IOT administration. Serum triglyceride levels were significantly reduced by IOT administration. Moreover, blood HDL-cholesterol levels were reduced by ovary removal. However, IOT administration after ovary excision significantly increase HDL-cholesterol levels. The biological activity of IOT could be confirmed from these results. Moreover, IOT can be used in the development of functional foods which are meant to improve blood circulation and anti-platelet aggregation function. According to these results, we could know that IOT improved blood flow and anti-platelet aggregation. Therefore, it is expected that IOT can be used for the development of functional foods.

Effect of supercooling on the storage stability of rapidly frozen-thawed pork loins (과냉각 온도가 급속냉동-해동 처리된 돈육 등심의 저장성에 미치는 영향)

  • Choi, Eun Ji;Park, Hae Woong;Chung, Young Bae;Kim, Jin Se;Park, Seok Ho;Chun, Ho Hyun
    • Food Science and Preservation
    • /
    • v.24 no.2
    • /
    • pp.168-180
    • /
    • 2017
  • This study was performed to determine the rapid thawing method for reducing the thawing time of frozen pork loins and to examine the effects of supercooling on the microbiological, physicochemical, and sensory qualities of fresh and frozen-thawed pork during storage at -1.5, 4, and $15^{\circ}C$. Forced-air thawing at $4^{\circ}C$ was the most time-consuming process, whereas radio frequency thawing time was the shortest by dielectric heating. The supercooling storage temperature was chosen to be $-1.5^{\circ}C$ because microstructural damages were not observed in the pork sample after cooling at $-1.5^{\circ}C$ for 24 h. Fresh or frozen-thawed pork loins stored at $-1.5^{\circ}C$ had lower drip loss and total volatile base nitrogen, thiobarbituric acid-reactive substance, and Hunter b* levels than loins stored at 4 and $15^{\circ}C$. In addition, the least degree of increase in preexisting microorganisms counts of the fresh or frozen-thawed pork loin samples was obtained during supercooled storage at $-1.5^{\circ}C$. Sensory quality results of fresh and frozen-thawed pork loin samples stored at $-1.5^{\circ}C$ showed higher scores than the samples stored at 4 and $15^{\circ}C$. These data indicate that supercooling at $-1.5^{\circ}C$ in the meat processing industry would be effective for maintaining the quality of pork meats without ice crystal nucleation and formation.

Development of a Thermoplastic Oral Compensator for Improving Dose Uniformity in Radiation Therapy for Head and Neck Cancer (두경부암 방사선치료 시 선량 균일도 향상을 위한 Thermoplastic 구강 보상체의 개발)

  • Choi, Joon-Yong;Won, Young-Jin;Park, Ji-Yeon;Kim, Jong-Won;Moon, Bong-Ki;Yoon, Hyong-Geun;Moon, Soo-Ho;Jeon, Jong-Byeong;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.23 no.4
    • /
    • pp.269-278
    • /
    • 2012
  • Aquaplast Thermoplastic (AT) is a tissue-equivalent oral compensator that has been developed to improve dose uniformity at the common boundary and around the treated area during radiotherapy in patients with head and neck cancer. In order to assess the usefulness of AT, the degree of improvement in dose distribution and physical properties were compared to those of oral compensators made using paraffin, alginate, and putty, which are materials conventionally used in dental imprinting. To assess the physical properties, strength evaluations (compression and drop evaluations) and natural deformation evaluations (volume change over time) were performed; a Gafchromic EBT2 film and a glass dosimeter inserted into a developed phantom for dose verification were used to measure the common boundary dose and the beam profile to assess the dose delivery. When the natural deformation of the oral compensators was assessed over a two-month period, alginate exhibited a maximum of 80% change in volume from moisture evaporation, while the remaining tissue-equivalent properties, including those of AT, showed a change in volume that was less than 3%. In a free-fall test at a height of 1.5 m (repeated 5 times as a strength evaluation), paraffin was easily damaged by the impact, but AT exhibited no damage from the fall. In compressive strength testing, AT was not destroyed even at 8 times the force needed for paraffin. In dose verification using a glass dosimeter, the results showed that in a single test, the tissue-equivalent (about 80 Hounsfield Units [HU]) AT delivered about 4.9% lower surface dose in terms of delivery of an output coefficient (monitor unit), which was 4% lower than putty and exhibited a value of about 1,000 HU or higher during a dose delivery of the same formulation. In addition, when the incident direction of the beam was used as a reference, the uniformity of the dose, as assessed from the beam profile at the boundary after passing through the oral compensators, was 11.41, 3.98, and 4.30 for air, AT, and putty, respectively. The AT oral compensator had a higher strength and lower probability of material transformation than the oral compensators conventionally used as a tissue-equivalent material, and a uniform dose distribution was successfully formed at the boundary and surrounding area including the mouth. It was also possible to deliver a uniformly formulated dose and reduce the skin dose delivery.

Changes in quality characteristics of sliced garlic with different freezing conditions during storage (냉동조건에 따른 편마늘의 냉동저장 중 품질변화)

  • Kim, Seok-Young;Kim, Hee-Sun;Kim, Jin-Se;Han, Gwi-Jung
    • Food Science and Preservation
    • /
    • v.24 no.6
    • /
    • pp.746-757
    • /
    • 2017
  • This study was performed to evaluate the effect of different freezing conditions and storage periods on physicochemical and microbial characteristics of garlic. Garlics were washed, dried, sliced to 0.3 cm then packed in LDPE+LLDPE film bags. They were treated with still-air freezing at $-20^{\circ}C$ (SAF20), $-40^{\circ}C$ (SAF40) and immersed-liquid freezing at $-40^{\circ}C$ (ILF40). Frozen garlics were stored under frozen storage conditions for 7 months at $-20^{\circ}C$ and quality characteristics were measured monthly during the frozen storage. Freezing rate of garlic was the fastest in ILF 40 (10 min), SAF40 (40 min) and SAF20 (1,600 min) sequentially. In ILF40, drip loss, cutting force, total aerobic bacteria count and pH were the lowest, whereas pyruvic acid and allicin content were the highest (p<0.05) during frozen storage, these results were the most similar characteristics with the fresh garlic. During frozen storage, drip loss, color difference and total organic acid content were significantly fluctuated in SAF20 (p<0.05), while they were not changed in ILF40. Overall, total aerobic bacteria count and pH decreased, cutting force, pyruvic acid and allicin content remained unchanged in all groups. In conclusion, the optimal freezing conditions for garlic with the least quality changes was considered to be ILF40 (immersed liquid freezing), keeping quality characteristics up to 7 months by freezing storage.

Site Selection of Wildlife Passage for Leopard Cat in Urban Area using Space Syntax (공간구문론을 이용한 도시 내 삵 이동통로 적지선정)

  • Park, Jong-Jun;Woo, Dong-Geol;Oh, Dae-Hyun;Park, Chong-Hwa
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.40 no.1
    • /
    • pp.92-99
    • /
    • 2012
  • Many wildlife habitats have been destroyed and fragmented during the rapid industrialization and urbanization process in Korea. It is essential to connect these fragmented habitats to reduce road-kill of many types of endangered urban wildlife. The site selection for wildlife passages must take into account the behavior of the wildlife species for safe crossing utilizing many artificial barriers in urban areas. This study attempted to identify potential wildlife passage sites for the endangered and protected leopard cats of Gangseo Ecological Park in Seoul, Korea. A space syntax analysis, an analytical technique to objectively evaluate the spatial configurations related to passage selection, found that the integration value represents the accessibility and connectivity of spaces. In this paper, this means that the bigger the integration value, the more frequently the leopard cat passes through. The leopard cats were captured and radio-tracked for 72 hours once a month from March to June of 2009. The ArcGIS and Animal Movement of Hawth Tools were used to analyze the home range and movement paths, and Axwoman 4.0 was used to analyze space syntax. The daily average movement distance was $2.099{\pm}1.08km$. During the survey period, the leopard cats crossed over an urban expressway more than 20 times, running the risk of road-kill. The range of global integration values was 0.458~1.834, while that of the local integration was 0.210~6.061. Five sites that met across the leopard cats' movement routes and roads were selected to measure the local and global integrate values. Among these sites, the higher the integration value, the higher the road-kill possibility. Thus, two of five sites with high global and local integration values were suggested as potential wildlife passage sites for the leopard cats. Now, three tunnel passages are under construction at the suggested sites for which local integration value was highest (LI=4.369). Further studies are scheduled to verify these potential sites as suitable wildlife passages.