• Title/Summary/Keyword: 통계분석연구

Search Result 15,962, Processing Time 0.045 seconds

Short-term Effect of Botulinum Toxin Injection on the Surface EMG of Masticatory Muscles and Jaw Function (교근 부위의 보툴리눔 독소 주사가 저작근의 근전도 및 악기능에 미치는 영향)

  • Lee, Jeong-Yun;Park, Hee-Kyung;Chung, Jin-Woo
    • Journal of Oral Medicine and Pain
    • /
    • v.31 no.1
    • /
    • pp.69-77
    • /
    • 2006
  • Botulinum toxin injection has been used in the masticatory muscle area as an effective treatment method of various movement disorders and facial contouring, but its effects on jaw function have not been evaluated. The aims of this study were to evaluate the effects of botulinum toxin type A injection into the masseter muscle on the EMG activities of masseter and anterior temporal muscles, and the limitation of jaw function. Fourteen healthy subjects were recruited. Five subjects were injected with 80 units of botulinum toxin type A(Dysport, Ipsen, Wrexham, UK) into each side of masseter muscle, and nine subjects were injected with saline into the same site as the botulinum toxin group. The surface EMG activities at maximum voluntary contraction of masseter and anterior temporal muscles were recorded before, 1 week, 2 weeks, and 3 weeks after injection. Presence of jaw functional limitations in each subject was investigated using Korean version of Jaw Functional Limitation Scale(JFLS) questionnaire. The masseter muscle EMG was gradually decreased in the botulinum toxin group comparing with that of the control group(p<0.001), but the anterior temporal muscle EMG did not show significant changes. There was significant increases in the mastication (p<0.01), and global jaw limitation(p<0.05) subscales of JFLS at 1 week after injection, but no significant changes in the other subscales including opening, and verbal and emotional expression during the recording periods. Our results suggest that botulinum toxin injection into masseter muscle can affect modest limitation in mastication function at 1 week after injection but recovered to the baseline until 3 weeks after injection. The EMG activity of masseter muscle had been gradually decreased until 3 weeks after botulinum toxin injection but the anterior temporal muscle did not show any significant changes.

New Perspectives on Sunday School of Korean Church for Next Generation (다음 세대와 한국교회 주일학교의 새 전망)

  • Kim, Jeong Joon
    • Journal of Christian Education in Korea
    • /
    • v.67
    • /
    • pp.11-44
    • /
    • 2021
  • In the early 21st century, the global COVID-19 pandemic, which has arisen during the development of the technological science of the Fourth Industrial Revolution, has been a great challenge in all fields including politics, economy, industry, education and religion in Korean society. To prevent the spread of the COVID-19 epidemic, the Korean government announced 'social distancing guidelines,' focused on the 'prohibition of three conditions'(crowd, closeness, airtight) for safety reasons. These quarantine guidelines made it more difficult for Korean churches and Sunday schools to operate. In general, looking at the statistical data of the major denominations of the Korean Church in the second half of the 20th century, shows that the Church has entered a period of stagnant or declining growth. Data also show that the number of students attending Sunday School is decreasing. The researcher identified four causes of the crisis faced by the Korean church and Korean Sunday school entering the 21st century. These trends are influenced by the tendencies of postmodernism, the deconstruction of modern universalism, the certainty and objectivity of knowledge, and the grand narrative and worldview of diffusion. Moreover, it is a phenomenon in which the young population decreases in contrast to the increasing elderly population in the age of population cliff in Korean society. Sunday Schools are also facing a crisis, as the youth population, who will become the future heroes of the Korean church, is declining. Finally, constraints of Church and Sunday school education activities are due to COVID-19 Pandemic. As analysis shows the loss of the Church's educational vision and a decrease in the passion for education. Accordingly, the researcher suggests four new strategies for the next generation of Korean Sunday schools, whose ranges from 200 members or less; this range covers the majority of Sunday School program run by churches in Korea. First, in the age of postmodernism, a time of uncertainty and relativism, Christian Societies requires teachers who are certain of absolute Christian truth and faith. Second, in an era of declining population cliffs for younger generations, a shift to a home-friendly Sunday school paradigm is needed. Third, during the COVID-19 pandemic, educational activities must appropriately utilize face-to-face and non-face-to-face communication. Finally, even in difficult times, Korean Sunday school should nevertheless remember the Lord's great commandment(Matthew 28:18-20) and restore the vision and passion of education to announce and teach the gospel. The researcher hopes that this study will provide small, positive steps in rebuilding Korean Sunday school educational activities for future generations in difficult times.

An Optimization Method of Measuring Heart Position in Dynamic Myocardial Perfusion SPECT with a CZT-based camera (동적 심근관류 SPECT에서 심장의 위치 측정방법에 대한 고찰)

  • Seong, Ji Hye;Lee, Dong Hun;Kim, Eun Hye;Jung, Woo Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.1
    • /
    • pp.75-79
    • /
    • 2019
  • Purpose Cadmium-zinc-telluride (CZT) camera with semiconductor detector is capable of dynamic myocardial perfusion SPECT for coronary flow reserve (CFR). Image acquisition with the heart positioned within 2 cm in the center of the quality field of view (QFOV) is recommended because the CZT detector based on focused multi-pinhole collimators and is stationary gantry without rotation. The aim of this study was to investigate the optimal method for measuring position of the heart within the center of the QFOV when performing dynamic myocardial perfusion SPECT with the Discovery NM 530c camera. Materials and Methods From June to September 2018, 45 patients were subject to dynamic myocardial perfusion SPECT with D530c. For accurate heart positioning, the patient's heart was scanned with a mobile ultrasound and marked at the top of the probe where the mitral valve (MV) was visible in the parasternal long-axis view (PLAX). And, the marked point on the patient's body matched with the reference point indicated CZT detector in dynamic stress. The heart was positioned to be in the center of the QFOV in rest. The coordinates of dynamic stress and rest were compared statistically. Results The coordinates of the dynamic stress using mobile ultrasound and those taken of the rest were recorded for comparative analysis with regard to the position of the couch and analyzed. There were no statistically significant differences in the coordinates of Table in & out, Table up & down, and Detector in & out (P > 0.05). The difference in distance between the 2 groups was measured at $0.25{\pm}1.00$, $0.24{\pm}0.96$ and $0.25{\pm}0.82cm$ respectively, with no difference greater than 2 cm in all categories. Conclusion The position of the heart taken using mobile ultrasound did not differ significantly from that of the center of the QFOV. Therefore, The use of mobile ultrasound in dynamic stress will help to select the correct position of the heart, which will be effective in clinical diagnosis by minimizing the image quality improvement and the patient's exposure to radiation.

Comparison Analysis of The results of IRMA Test among Different Equipment According to Algorithm change. (IRMA 검사법 중 알고리즘 변경에 따른 장비 간 결과값 비교분석)

  • Kim, Jung In;Kwon, Won Hyun;Lee, Kyung Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.2
    • /
    • pp.43-50
    • /
    • 2019
  • Purpose The principle of nuclear medicine test is divided into two main categories: competition(radioimmunoassay, RIA) and noncompetitive reaction(Immunoradiometric assay, IRMA). It is known that the curve fitting method, which is commonly used in inspection field, uses Spline interpolation in RIA method and Linear interpolation method in IRMA method. Among them, the insulin test using the IRMA test showed a significant difference, especially at low concentrations, despite the same algorithm of linear interpolation between fully automated radio immunoassay analyzers. In this study, we aim to obtain results from applying two different of algorithm using fully automated radio immunoassay analyzers including Gamma pro, Gamma 10, Cobra, and SR300. Materials and Methods A total of 30 test samples were selected for the test of TSH, ferritin, C-peptide, and insulin serum levels. Test was performed by IRMA method. We compared the difference in the results of applying the linear interpolation method and the spline interpolation method to Gamma Pro, Gamma 10, Cobra, and SR300 equipment. Results Two-way ANOVA was used for statistical analysis. The significance level was applied as P <0.05. The results of TSH, ferritin, C-peptide, and insulin tests were compared between the fully automated radio immunoassay analyzers. There was a significant difference between ferritin, C-peptide, and insulin serum levels(P<0.001). TSH didn't show any significant different between the devices(P=0.29). In the difference between linear and spline interpolation, there was no significant difference between insulin test(P=0.08), TSH test(P=0.81), and Ferritin test(P=0.06). However, C-peptide test showed a significant difference(P=0.03). Especially, the insulin test showed significant difference in lower ranges. As a result of comparing and analyzing the difference between the two interpolation methods, the devices in the low concentration group showed significant difference(P<0.001). Conclusion In case of new equipment in the laboratory it is necessary to recognize that there is a difference in the curve fitting method for each automated radio immunoassay analyzers in the low concentration area when the principle of inspection is IRMA method.

Comparison and Review of GBEF% on the Anterior and Right Lateral Images of Nuclear Hepatobiliary Scan (핵의학 간담도 스캔 시, 전면상과 우측 측면상에서의 담낭박출률에 대한 비교 및 고찰)

  • Lee, Eun-Byeol;Kim, Jae-Il;Do, Yong-Ho;Llm, Jung-Jin;Cho, Sung-Wook;Noh, Gyeong-Woon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.2
    • /
    • pp.92-96
    • /
    • 2018
  • Purpose In case of nuclear medical hepatobiliary scan, To quantitatively evaluate contractility of a gallbladder, gallbladder ejection fraction (GBEF%) is calculated from anterior images using fatty meal. However, when a gallbladder and other organs overlap on an anterior image, the gallbladder ejection fraction is not accurately evaluated. In order to reduce this error, the objective of our study was to figure out whether there is a significant difference in GBEF% calculated from the anterior and right lateral images. Materials and Methods After intravenous injection of 99mTc-Mebrofenin 370 MBq to randomly 50 patients who visited our hospital, we started to examine nuclear hepatobiliary scan. Using skylight(Philips, United States), we acquired anterior and right lateral image at 10 minutes, 20 minutes, 30 minutes, 60 minutes, 90minutes after injection. Using images at 60 and 90 minutes, gallbladder ejection fraction (GBEF%) was calculated from the anterior and right lateral images using JETstream workspace. For drawing more accurate ROI, CT images were referenced and 4 radiologists calculated the GBEF% in the same image and calculated the average value. We assessed whether there was a significant difference in GBEF% calculated from the anterior and right lateral images using SPSS program(Statistical Package for the Social Science, SPSS Ver.18 Inc. USA). Results About randomly 50 patients, the average value of the GBEF% calculated from the anterior image was 63.212 and the average value of the GBEF% calculated from the right lateral image was 62.666. GBEF% decreased 0.433% on the right lateral image compared with anterior image. Result of paired sample t-test, p value is over 0.05. So, there was no significant difference in GBEF% calculated from the anterior and right lateral images. Conclusion In the case that a gallbladder and other organs are not separated on an anteior image, Right lateral image would be better to acquire more accurate GBEF% than using anterior image.

Comparison of the Morphometric Changes in the Cervical Foramen: Anterior Cervical Discectomy and Fusion versus Posterior Foraminotomy (전방 경유 디스크 절제술 및 유합술과 후방 추간공 절제술에서의 경추 추간공의 형태학적 변화 비교)

  • Chung, Sung-Soo;Sun, Woo-Sung;Chung, Jong-Chul;Heo, Ki-Sung;Kim, Hyun-Min
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.6
    • /
    • pp.512-518
    • /
    • 2021
  • Purpose: This study compared the change in foraminal space on magnetic resonance imaging (MRI) and the clinical outcome after anterior cervical discectomy and fusion (ACDF) versus foraminotomy in cervical foraminal stenosis. Materials and Methods: A retrospective case-control study was conducted from January 2018 to March 2019 on 186 patients who underwent ACDF and foraminotomy. One hundred and two cases were selected considering age, sex, and body mass index. MRI was performed before and on the 5th day after surgery to compare the changes in the foraminal diameter between the ACDF group (group A-51) and foraminotomy group (group B-51). Results: Between groups A and B, the average change in foraminal vertical diameter was 1.7 mm and 1.2 mm, respectively; group A was 0.5 mm larger difference (p=0.042). The average change in foraminal transverse diameter was 1.2 mm and 1.8mm, respectively; group B showed a 0.6 mm larger change (p=0.21). Both the neck disability index (NDI) and Japanese orthopaedic association (JOA) scores improved in both groups. Group A showed more improvement, but there was no significant difference (p=0.356, p=0.607, respectively). Conclusion: Foraminotomy is a useful option for patients with foraminal stenosis of the cervical spine because it showed comparable clinical and morphological results to ACDF and could minimize motion segment loss and muscle and ligament damage.

pH, Ion Release Capability, and Solubility Value of Premixed Mineral Trioxide Aggregates (Premixed MTA제재의 pH, 이온 유리 정도, 용해도)

  • Seolah, Back;YuJi, Jang;Junghwan, Lee;Joonhaeng, Lee;Jisun, Shin;Jongbin, Kim;Miran, Han;JongSoo, Kim
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.49 no.4
    • /
    • pp.379-391
    • /
    • 2022
  • The current study aimed to compare the pH, solubility value, and ion release capability of premixed mineral trioxide aggregates (MTAs) versus conventional pulp capping materials before and after setting. The following materials were used: resin-modified calcium silicate cement (TheraCal LC®, TLC), resin-modified calcium hydroxide cement (Ultra-BlendTM plus, UBP), and 2 kinds of premixed MTA (Endocem MTA® premixed regular [EMPR] and Well-RootTM PT [WRP]). The specimens of each material were prepared before and after setting and were immersed in distilled water. The materials' pH and solubility value were assessed. Next, three kinds of ion (calcium, sulfide, and strontium) released by pulp capping materials were evaluated via inductively coupled plasma atomic emission spectrometry. In the after-setting group, the pH of TLC and UBP decreased. However, the pH of the premixed MTAs increased with time. TLC released a higher concentration of strontium ion compared with the other materials. Meanwhile, EMPR released a significantly high concentration of sulfide ion (p < 0.05). In the after-setting group, the 2 kinds of premixed MTAs released a significantly higher concentration of calcium ion compared with the other materials (p < 0.05). In the after-setting group, EMPR had a significantly low solubility value (p < 0.05). The Kruskal-Wallis test, followed by the Mann-Whitney U test with Bonferroni correction, was used in statistical analysis. In conclusion, resin-modified calcium silicate cement, modified calcium hydroxide cement, and the 2 kinds of premixed MTAs had an alkaline pH and low solubility value and they released various concentrations of ions after setting.

Surface Roughness and Cariogenic Microbial Adhesion after Polishing of Smart Chromatic Technology-based Composite Resin (Smart Chromatic Technology 기반 복합 레진의 폴리싱 이후 표면 거칠기 및 우식원성 미생물 부착 )

  • Haesong Kim;Juhyun Lee;Haeni Kim;Howon Park
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.50 no.1
    • /
    • pp.65-74
    • /
    • 2023
  • This study compared the surface roughness and microbial adhesion characteristics of Omnichroma, a novel composite resin developed using "smart chromatic technology", with those of two other conventional composite resins with different filler compositions. A total of 144 specimens were fabricated using 3 types of composite resins: Omnichroma (nano-spherical), Filtek Z350XT (nanofill), and Tetric N-Ceram (nanohybrid) and, divided into 3 groups of 48. Finishing was performed using tungsten carbide burs. Specimens were then divided into 3 subgroups using different polishing methods: Control, SofLex, and PoGo. Surface roughness was analyzed quantitatively and qualitatively using an atomic force microscope and a scanning electron microscope. Microbial adhesion was assessed by culturing Streptococcus mutans on the specimens for 24 hours and then measuring colony-forming units attached to the upper surface. The surface roughness (Ra) of Omnichroma was 0.123 ㎛ after finishing, and it exhibited a smooth surface compared to the other resins. However, after polishing, there were no significant differences in the surface roughness between the three composite groups, regardless of the polishing methods. The surfaces of the Control subgroups were significantly rougher than those of the SofLex subgroups in all 3 composite groups. However, except for Tetric N-Ceram, there were no significant differences between the Control and PoGo subgroups in the other composite groups. Microbial adhesion assessment showed no significant differences between any of the 3 composite resin subgroups; however, Omnichroma exhibited higher microbial adhesion than the other two composites. No significant correlation was observed between surface roughness and microbial adhesion.

Effects of Changes in Collimation Size and the sub ROI on Exposure Index of Hand Radiography (손 방사선검사에서 조사야 크기와 보조관심영역 변화가 노출지수 값에 미치는 영향)

  • Young-Cheol Joo;Dong-Hee Hong
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.6
    • /
    • pp.851-857
    • /
    • 2023
  • The purpose of this study is to investigate the effect of changes in collimation size and sub ROI on exposure index(EI) in hand radiography, present collimation size and EI suitable for average hand size of Koreans, and present the effect of changes in sub ROI on EI. The subjects of this study were hand-wrist phantom, and the exposure conditions were set to 55 kVp, 125, mA, and 6.25 mAs, and source to image receptor distance was applied to 110 cm. Based on the vendor recommended sub-ROI (18.7" × 18.7", 8" × 10", 8" × 7.4", 6" × 7.4")and the textbook's recommended sub-ROI 8" × 10", each obtaining 30 images, and comparing the EI shown in the equipment. The EI according to the change in the size of the collimation were 1663.7±4.52, 8"×10" is 1489.1±4.49, 8"×7.4" is 1716.9±3.00, 6"×7.4" is 168.7±3.66 for each EI, and the average value of each value was statistically significant. The average EI according to the sub ROI change was 1489.1±4.49 for SS, LS was 1694.8±5.19 for AEC, 2052.9±5.96, VR was 1548.3±3.20, and HR was 1663.2±4.33. The appropriate field size considering the hand size of Koreans was found to be 8"×7.4". In addition, when the field size increases based on the generally known field size (8"×10") during hand radiography, the EI value changes from a maximum of 15% to a minimum of 11%, and the sub ROI shape based on sub ROI 'SS' Depending on the change, the EI value increased from a maximum of 37% to a minimum of 3%.

Comparison between Uncertainties of Cultivar Parameter Estimates Obtained Using Error Calculation Methods for Forage Rice Cultivars (오차 계산 방식에 따른 사료용 벼 품종의 품종모수 추정치 불확도 비교)

  • Young Sang Joh;Shinwoo Hyun;Kwang Soo Kim
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.25 no.3
    • /
    • pp.129-141
    • /
    • 2023
  • Crop models have been used to predict yield under diverse environmental and cultivation conditions, which can be used to support decisions on the management of forage crop. Cultivar parameters are one of required inputs to crop models in order to represent genetic properties for a given forage cultivar. The objectives of this study were to compare calibration and ensemble approaches in order to minimize the uncertainty of crop yield estimates using the SIMPLE crop model. Cultivar parameters were calibrated using Log-likelihood (LL) and Generic Composite Similarity Measure (GCSM) as an objective function for Metropolis-Hastings (MH) algorithm. In total, 20 sets of cultivar parameters were generated for each method. Two types of ensemble approach. First type of ensemble approach was the average of model outputs (Eem), using individual parameters. The second ensemble approach was model output (Epm) of cultivar parameter obtained by averaging given 20 sets of parameters. Comparison was done for each cultivar and for each error calculation methods. 'Jowoo' and 'Yeongwoo', which are forage rice cultivars used in Korea, were subject to the parameter calibration. Yield data were obtained from experiment fields at Suwon, Jeonju, Naju and I ksan. Data for 2013, 2014 and 2016 were used for parameter calibration. For validation, yield data reported from 2016 to 2018 at Suwon was used. Initial calibration indicated that genetic coefficients obtained by LL were distributed in a narrower range than coefficients obtained by GCSM. A two-sample t-test was performed to compare between different methods of ensemble approaches and no significant difference was found between them. Uncertainty of GCSM can be neutralized by adjusting the acceptance probability. The other ensemble method (Epm) indicates that the uncertainty can be reduced with less computation using ensemble approach.