• Title/Summary/Keyword: 토하중

Search Result 665, Processing Time 0.035 seconds

Development of an Empirical Equation for Estimating Lond Transfer Curve for Micropile in Weathered Soils (풍화지반에 근입된 마이크로파일의 하중전이곡선 추정을 위한 경험식 개발)

  • Park, Seong-Wan;Cho, Kook-Hwan;Roh, Kang-Koo
    • Journal of the Korean Geotechnical Society
    • /
    • v.23 no.1
    • /
    • pp.5-11
    • /
    • 2007
  • Micropiles have been used for underpinning or rehabilitation of existing foundations, and direct structural support system as well. However, relatively few studies have been done on the load-transfer mechanism of micropile systems in Korea. In addition to that, only the limited information is available for estimating the side friction values on micropiles installed in weathered soils. In this study, a full-scale test on an instrumented micropile is performed in order to establish the load-transfer curves based on a hyperbolic function. Then, an empirically derived equation that correlates the load-transfer curve of micropiles with the N values from field standard penetration tests is proposed. The results from all procedures are presented in this paper. Finally, back analysis using a finite difference method and the published field data are adopted for examination of a developed skin friction equation of micropile in weathered soils respectively.

Pullout Capacity of Ground Anchors in Weathered Soil (풍화토 지반에 설치된 앵커의 인발 특성)

  • 김낙경
    • Journal of the Korean Geotechnical Society
    • /
    • v.17 no.4
    • /
    • pp.231-239
    • /
    • 2001
  • 건설 현장에서 널리 사용되고 있는 그라운드 앵커의 거동 특성을 연구하기 위하여 계측기를 부착한 일곱 개의 그라운드 앵커를 국내에 널리 분포되어 있는 화강 풍화토 지반인 $\bigcirc$$\bigcirc$$\bigcirc$대학교 지반 시험장에 설치하여 인발 시험을 수행하였다. 저압 그라우트 인장형 앵커 3개와 압축형 앵커 4개를 시험하였고, 시험은 AASHTO 규정에 의거한 인발시험, 크리프시험, 장기거동시험을 수행하였다. 시험 결과로부터 화강 풍화토 지반에 설치된 저압그라우트 직선형 앵커의 지반과의 마찰계수, 크리프 변형율, 하중감소 특성을 평가하였다.

  • PDF

A Consideration with Load Height Effects for Inelastic Lateral-Torsional Buckling of Stepped Beam Subjected to a Concentration Load (집중하중을 받는 I형 스텝보의 비탄성 횡-비틀림 좌굴강도에 하중고 효과가 미치는 영향 고찰)

  • Park, Yi-Seul;Oh, Jeong-Jae;Park, Jong-Sub
    • Proceedings of the KAIS Fall Conference
    • /
    • 2011.05a
    • /
    • pp.464-467
    • /
    • 2011
  • 본 논문에서는 기존에 수행된 비탄성 영역 내 비지지 길이가 존재하고 균일단면을 가지는 I형 보의 좌굴 강도에 대한 해석적 이론적 연구를 토대로 변단면 I형보의 하중고 효과를 고려한 비탄성 횡-비틀림 좌굴강도에 대한 연구를 수행하였다. 유한요소해석에는 4절점 쉘요소인 S4R요소가 사용되었고, 플랜지 길이방향 비, 너비방향 비, 두께의 비로 스텝보를 나타내었으며, 집중하중을 작용시켰다. 개발된 좌굴강도 제안식은(오정재 등, 2011)과 해석결과를 하중고 효과 평가 시 큰 단면변화를 보이는 경우를 제외하고는 ${\pm}10%$의 오차범위를 나타내었다. 본 연구 결과는 다양한 형식의 I형보가 사용되는 빌딩 및 교량의 경제적이고 합리적인 설계의 근간을 제공해 줄 것이며, 향후 비탄성 횡-비틀림 좌굴강도에 대한 연구에도 많은 도움이 될 것이다.

  • PDF

Numerical and Experimental Researches on Buried Three-layered Pipeline Subjected to Soil Surface Vibration Compaction Loads (매설 삼중 보온관에 작용하는 진동 다짐 하중의 수치해석적 적용 및 현장 실험 비교, 분석)

  • Kim, Moon-Kyum;Won, Jong-Hwa;Kim, Jeong-Jae;Choi, Bong-Hyuck
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2010.04a
    • /
    • pp.421-424
    • /
    • 2010
  • 최근 노후한 기존 구조물의 교체 및 건물 증축으로 인하여, 도심지 내 공사 현장 및 주변 지반에 매설된 지중 배관은 차량 이동 하중 및 건설 장비 하중 등의 진동에 노출이 되어있는 실정이다. 이러한 장비하중이 매설배관에 미치는 영향을 분석, 예측하기 위하여 실증 실험 결과를 토대로 모델을 검증하고 수치해석을 수행하였다. 그 결과 최대 발생 응력은 외관은 $270^{\circ}$에서, 내관은 $180^{\circ}$에서 발생 하였으며, 이는 폴리우레탄 보온재의 하중 분산 효과로 설명 할 수 있다.

  • PDF

Equivalent Vehicle Load Factors for Girder and Beam of Parking Garage Structure (주차장 구조물의 보와 거더의 등가차량 하중계수에 관한 연구)

  • 곽효경;송종영
    • Computational Structural Engineering
    • /
    • v.10 no.3
    • /
    • pp.203-216
    • /
    • 1997
  • The Equivalent vehicle load factors of Beams and Girders on parking garage structure are proposed in this study. Without taking the sophisticated numerical analysis for the concentrated wheel loads, the design member forces of beam and girder can be easily calculated only with those for the distributed load by using the constructed relationships between the equivalent vehicle load factor and the length of member. Besides, the standard vehicle with total weight of 2.4ton is designed based on the review of many foreign design codes for parking garage and the investigation of small to medium vehicles made in Korea. Finally the efficiency and the reliability of the proposed equivalent vehicle load factors are demonstrated through the application of the typical beam and girder.

  • PDF

A Simple Evaluation Method for Shear Strength Decreasing with Increasing Number of Cyclic Loading (반복하중 증가에 따라 감소하는 전단강도의 간이 평가법)

  • Song, Byungwoong
    • Journal of the Korean GEO-environmental Society
    • /
    • v.8 no.4
    • /
    • pp.57-65
    • /
    • 2007
  • Earthquake is one of the factors to affect the stability of geotechnical structures. Numerous past earthquakes have shown that earthquakes have taught that damage of soil structures could occur on fine soils as well as coarse soils. For that reason, earthquake-induced decreasing tendency for strength on both coarse and fine soils has been investigated using direct simple shear (DSS) tests in laboratory. Based on the testing results the decreasing tendency for strength on coarse and fine soils is clearly identified in terms of the concept of volume decrease potential and plasticity index, respectively. Most of the soils except the weathered soil have shown similar reduction tendency of strength with the increasing number of cycles. Liquefaction strength of coarse and fine soils appears to decrease with the increment of volume decrease potential and the decrement of plasticity index, respectively. Reduction of strength on the weathered soil is particularly remarkable rather than others, which might be owing to the collapse phenomenon. From the DSS test results for soils, proposed is a simple method to evaluate strength decrement with the increasing number of cycles, and it can help estimate decrement of strength with the number of cycles easily.

  • PDF

Fundamental Study on the Behavior of Laterally Loaded Model Pile with Varying Water Content in Sand (사질토 지반에서 함수비 변화에 따른 모형말뚝의 수평거동에 대한 기초적 연구)

  • 김병탁;김영수
    • Journal of the Korean Geotechnical Society
    • /
    • v.17 no.4
    • /
    • pp.27-37
    • /
    • 2001
  • 본 연구에서는 지금까지 수행한 건조토 지반에 대한 말뚝의 수평거동 연구의 연속된 연구로서 지반내에 함수비가 존재하는 포화토 및 습윤토 지반에서의 수평거동에 대한 지반내 함수비의 영향성을 평가하고자 함이 목적이다. 말뚝의 수평거동을 고찰하기 위하여 각각 다른 함수비를 갖는 네 종류의 지반과 말뚝의 두부 및 선단 구속조건이 다른 네 종류의 말뚝조건으로 모형실험을 수행하였다. 본 연구에서 1회의 지하수 상승과 하강을 반복하는 모형실험결과에 의하면, 포화토와 습윤토 지반의 수평지지력은 건조토 지반에 비하여 각각 26%~45% 감소와 20%~36%정도 증가하는 것으로 나타났다. 말뚝두부 고정과 선단 자유조건의 경우, 동일 수평변위 1mm에서의 최대 휨모멘트는 건조토 지반에 비하여 25%의 함수비를 갖는 습윤토 지반에서 약 48% 증가하나, 34.06%의 함수비를 갖는 포화토 지반에서는 반대로 68% 감소하였다. 이는 지하수의 존재로 인한 입자간 인력에 의한 유효응력과 겉보기강도의 증가 그리고 단위중량의 증가로 설명할 수가 있다. 지속수평하중에 대한 수평변위와 최대 휨모멘트의 변화를 포화토 및 습윤토 지반에서 관찰할 수 있었다.

  • PDF

Behavior of shallow 2-Arch tunnel due to excavation under horizontal discontinuity plane (수평 불연속변 하부에 굴착한 얄은 심도의 2-Arch 터널의 거동)

  • Cheon, Eun-Sook;Kim, Hong-Moon;Lee, Sang-Duk
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.7 no.3
    • /
    • pp.227-237
    • /
    • 2005
  • In this study, the behavior of shallow 2-Arch tunnel due to excavation under horizontal discontinuity plane was verified experimentally. The model tests were carried out by varying the overburden height and the location of the discontinuity plane. The model tests followed exactly the real 2-Arch tunnel construction stages. As a result, it is discovered that stress-transfer mechanism and loosening area around the 2-Arch tunnel depends on the overburden heights and the location of the discontinuity plane. And central pillar load is also dependent on overburden height, location of discontinuity plane and construction stages.

  • PDF

Study on the Design Standard for the Wind Resistant on Transmission Tower (송전용 풍하중 설계기준 합리화를 위한 기술검토)

  • Shin, Koo-Yong;Lee, Dong-IL;Shin, Tae-Woo;Choi, Jin-Sung;Bang, Hang-Kweon
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.652-654
    • /
    • 2007
  • 본 논문에서는 국가의 기간 에너지원인 전력망을 구성하는 구조물인 송전철탑의 설계하중에 가장 큰 요인으로 작용하는 기준풍속 산정을 위한 연구내용을 고찰하고자 한다. 현행의 송전용 지지물 설계 기준은 전기설비기술기준에 고시된 가공전선로 지지물에 관한 기준을 토대로 전력사의 실무적인 설계를 위하여 보다 구체화하여 작성된 한국전력공사 송전설계기준에 근거하고 있다. 이러한 기존 설계기준은 1985년 이전의 기상자료를 토대로 제정되어 본 논문에서는 1980년대 후반부터 약 20년간의 기상청의 풍향, 풍속자료를 추가로 확보하고 이를 분석하여 재현기간을 반영한 지역별 설계기준 풍속 Map을 제시하였다. 이러한 흐름으로 최근의 기상자료를 포함하여 보다 정확한 분석을 도모하고, 사회 환경의 급변함에 따라 우려되는 기상이변 등을 고려한 안전성과 경제성이 향상된 기준풍속 산정과정을 고찰하고, IEC 등 해외 주요국의 풍하중 설계기준에서 반영하고 있는 국부지형을 고려한 설계방법에 대한 국내 기준 적용성 평가를 위한 비교분석 결과를 소개하였다.

  • PDF

Load Transfer Characteristics of Pile Foundation for Lightweight Pavement in Sand Soil using Laboratory Chamber Test (모형챔버시험을 이용한 사질토 지반의 경량포장체용 기초의 하중전달 특성)

  • Shin, Kwang-Ho;Hwang, Cheol-Bi;Jeon, Sang-Ryeol;Lee, Kwan-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.7
    • /
    • pp.4588-4594
    • /
    • 2014
  • In this study, small scaled (1/30) laboratory chamber tests of the pile foundation for a lightweight concrete pavement system were carried out to evaluate the safety of a pile foundation on sandy soil. The testing ground was simulated in the field and a standard pile-loading test was conducted. The test piles were divided into 3 types, Cases A, B and C, which is the location from the center of the slab by applying a vertical load. The interval between the piles was set to 8 cm. As a result of the pile foundation model test, the pavement settled when the vertical load was increased to 12kg from 1.5kg in sandy soil ground, particularly the maximum settlement of 0.04mm. Judging from the model chamber test, Case A showed compressive deformation, whereas Case B represented the compression and tensile forces with increasing vertical load. Case C showed an increase in tensile strain.