Journal of the Korean Society for Precision Engineering
/
v.21
no.9
/
pp.26-31
/
2004
일반적인 공업 제품은 다수의 부품들로 이루어져 있다. TV 등과 같은 가전제품은 천여개, 자동차는 만여개, 그리고 항공기는 십만여개의 부품으로 구성된다. 여러 개의 부품은 다양한 방법으로 조립되어 완제품을 이룬다. 자동차의 제조와 같은 기계공업 분야에서 가장 일반적인 조립방법은 볼트 또는 나사를 이용하는 방법이다.(중략)
Proceedings of the Korean Society of Precision Engineering Conference
/
2004.10a
/
pp.656-659
/
2004
As the demand for traceable calibrations of torque measuring devices has considerably increased both in the production sector and in research institutes, suitable standard machines had to be developed at the Korea Research Institute of Standards and Science. Owing to its special design, the small uncertainty of measurement required for the realization of the static torque can be reached (relative uncertainty of measurement < 5$\times$10$^{-5}$ in the measurement range between 500 and 2000 Nm, and < 1$\times$10$^{-4}$ in the measurement range from 10 to 500 Nm). The relative discrepancy between our torque calibration results of 2 kNm and PTB s (Physikalisch Technische Bundesanstalt, Germany) results was less than 2$\times$10$^{-5}$ , which confirming our uncertainty estimation.
Journal of the Korean Society for Precision Engineering
/
v.18
no.7
/
pp.46-52
/
2001
This study describes the precision control of the torque standard machine using a self-tuning fuzzy controller. The torque standard machine should generate the accurate torque for calibrating a torque sensor. In order to reduce the relative expanded uncertainty of the torque standard machine, when a weight is hanged to the end of the torque arm for generating the torque, the sloped torque arm should be accurately controlled to the horizontal level. If the slope of the torque arm is larger from the inaccurate control, the uncertainty of the torque standard machine due to control will be larger. This applies the inaccurate torque to a torque sensor to calibrate, and the measuring error of the torque sensor generate from it. Therefore the torque arm of the torque standard machine is accurately controlled. In this paper, the self-tuning fuzzy controller was designed using a fuzzy theory, and the torque arm of the torque standard machine was accurately controlled. The control gain of the fuzzy controller, that is the membership function size of the error, the membership function size of the error change and the membership function size of the controller were determined from the self-tuning. The control results of the torque standard machine were the overshoot within 0.0076mm, the rise time within 16.70sec and the steady state error within 0.0076mm.
Journal of the Korea Academia-Industrial cooperation Society
/
v.20
no.1
/
pp.1-8
/
2019
Most of rotor resistance estimators utilizes Classical qd Model (CQDM) and Alternate qd Model (AQDM). The rotor resistance estimators based on both models were shown to provide an accurate rotor resistance estimate under conditions where flux is constant such as a field-oriented control (FOC) based induction motor drives. Under the conditions where flux is varying such as a Maximum torque per amp (MTPA) control, AQDM based rotor resistance estimator estimates actual rotor resistance accurately even in different operating points. However, CQDM based rotor resistance estimator has not been investigated and its performance is questionable under condition where flux level is varying. Thus, in this work, the performance of CQDM based rotor resistance estimator was investigated and made comparisons with AQDM based estimator under conditions where flux level is significantly varying such as in MTPA control based induction motor drives. Unlike AQDM based estimator, the laboratory results show that the CQDM based estimator underestimates actual rotor resistance and exhibits an undesirable dip in the estimates in different operating points.
Lee, Choong Ho;Ha, Jong Woo;Jang, Ji Un;Lee, In Beom;Kim, Hyun Gyung
Proceedings of the Korean Society for Agricultural Machinery Conference
/
2017.04a
/
pp.86-86
/
2017
마늘파종기는 파종기구동부와 파종후 파종홀의 복토역할을 하는 파종기롤러, 지면과의 마찰을 통해 바퀴의 회전토크가 발생하며 발생된 토크는 파종기 내부 동력으로 전달되어 전체 파종시스템(배종, 호퍼캠, 파종부)을 동작 시키는 기능을 수행하는 파종바퀴, 마늘종구를 한알씩 집어올려 중간이송컵으로 이송하는 자세교정컵이 포함된 배종부와 자세교정컵에서 낙하된 마늘종구를 땅속으로 파종하는 파종장치로 구성된다. 배종율 95%, 2립 배종률 5% 성능을 확보할 수 있는 기술이 개발될 경우 세계적으로도 독보적인 기술 우위를 확보할 수 있다. 이와 같은 기본적인 기능을 구현할 수 있는 컨셉모델에 대한 설계를 수행하여 시제품개발 전 기구해석과 구조해석 등을 위한 기본설계를 수행하였다. 배종율 95% 이상을 확보하기 위해서는 기존의 현장경험의 의한 설계 방식으로는 한계가 있기 때문에 시뮬레이션 및 분석 개발이 필요한데, 프레임은 고정밀 마늘종구 배종부 장착을 위한 기본 구조물로써 작동시 동력을 얻기 위한 바퀴와 연계가 되도록 설계되었으며, 호퍼는 배종 수행을 위해 마늘을 저장해 두는 통으로써 배종부와 연결된다. 배종부의 배종판이 회전함에 따라서 배종판의 홈이 호퍼 내로 들어갔다 나오면서 마늘을 집게되며, 동력 전달부는 배종판을 회전시켜주고, 회전 속도 조절을 가능하게 한다. 파종부는 배종부에서 중간컵을 통해 하나씩 공급해준 마늘을 땅에 심는 부분으로서. 프레임의 바퀴 회전과 연동되어 회전하고 설계하였다. 배종판에서 중간컵으로 이송된 마늘을 파종부의 파종컵에 받아 회전하면서 땅속에 파종컵이 묻히면 파종컵이 열리면서 땅속에 마늘을 심는 원리이다. 조간조정은 7조식의 경우 초기설치시 고정되도록 설계되었으며 농촌진흥청 기계화 표준재배안에 따라 의성마늘 기준 $14{\times}14cm$(조간${\times}$주간)를 기준으로 개발하였다. 조간조정은 기계가 설치되면 조정하기 어려우므로 14cm로 설계하였으며, 주간조정은 원형배종장치의 구동기어부의 속도비로 간격을 조정할 수 있도록 기어장치를 설계하였다. 주간조정은 13에서 18cm의 범위에서 작동하도록 설계되었으며, 필요에 따라 간격조절이 가능함. 마늘은 그 크기가 다르고, 형상도 다르기 때문에 종자에 따른 개별적인 파종기술들이 개발되어야하기 때문에 개발 기간이 오래 걸리고, 수익에 비하여 개발비가 과다하게 요구되는 실정인데 축적된 시뮬레이션 툴을 이용한 파종기 분석 기술을 확보할 경우 다른 파종기의 연구 개발에도 크게 도움이 될 것으로 기대되며, 생육측정 실험과 동역학 해석 툴 RecurDyn을 통해 파종기의 기구학적 분석을 통한 설계반영 인자를 도출할 계획이다.
본 논문은 EPS(전자식 파워 스티어링)에 사용되는 Torque and Angle sensor 의 절대각 신뢰성 보증 방식에 관한 것으로, Inductive 방식의 센서에서 절대각 신호 신뢰성 보증에 대한 효과적인 방법을 제시한다. 전동식 파워 스티어링 시스템의 ECU(전자제어유닛)는 조타각도를 출력하는 2 개의 소자에서 버니어 알고리즘을 통해 360 도 이상의 멀티 조타각을 인식하게 된다. 토크&조향각 센서는 절대 조향각을 계산하는 1 개의 Hall IC 소자 신호와, 상대 조향각을 계산하는 ASIC 소자 신호를 사용하여 멀티 조타각을 인식한다. 인식된 조타각이 추가적인 검증 절차 없이 제어에 사용된다면, 센서의 이상 발생 시에 운전자의 조타감을 불편해질 수 있고, 나아가서는 차량사고의 위험을 발생시킬 수 있다.따라서 차량 거동 시 절대 조향각의 신뢰성 검증은 제어와 동시에 항상 요구되어야 한다. 특히, 유럽/미국 업계의 ISO 26262 표준 도입에 따라 절대 조향각의 높은 신뢰성이 요구된다. 본 논문에서는 이러한 요구사항을 만족하기 위해 측정된 절대각 신호를 기준으로 상대각 신호 2 개를 측정에 사용하고, Driving 시에도 절대각 기준의 신뢰도 향상을 위해 절대각 신호 1 개를 비교기로 사용한다. 최적화된 에러 기준을 근거로 절대 조향각 신호의 신뢰성을 보장하는 방법을 제안한다. 이러한 방법을 적용한다면, 정확하고 안정적으로 조타각을 결정함으로써 EPS 안전성 확보에 도움을 줄 수 있다.
A simple and practical method for the determination of caffeine in coffee, black tea and green tea was studied. The analysis of caffeine was performed by reverse phase high perfomance liquid chromatography using a ${\mu}-Bondapak$ C18 column at isocratic condition with methanol-acetic acid-water (20: 1: 79) on UV detector at 280 nm. The extraction and clean-up of caffeine in sample is based on combing a simple pretreatment with the use of a Sep-Pak Alumina A cartridge. The average recoveries of caffeine from several samples were 95.2 -101.3%, the relative standard deviation for the whole procedure was 0.10 ~ 0.62%, and the detection limit of caffeine in sample solution was about $0.1\;\mu\textrm{g}\;per\;ml$.
KSCE Journal of Civil and Environmental Engineering Research
/
v.44
no.5
/
pp.719-731
/
2024
For efficient construction management, linking BIM with schedule and cost is essential, but there are limits to the application of 5D BIM due to the difficulty in disassembling thousands of WBS and CBS. To solve this problem, a standardized WBS-CBS set is configured in advance, and when a new construction project occurs, the CBS in the BOQ is automatically linked to the WBS when a text most similar to it is found among the standard CBS (Public Procurement Service standard construction code) of the already linked set. A method was used to compare the text similarity of CBS more efficiently using artificial intelligence natural language processing techniques. Firstly, we created a civil term dictionary (CTD) that organized the words used in civil projects and assigned numerical values, tokenized the text of all CBS into words defined in the dictionary, converted them into TF-IDF vectors, and determined them by cosine similarity. Additionally, the search success rate increased to nearly 70 % by considering CBS' hierarchical structure and changing keywords. The threshold value for judging similarity was 0.62 (1: perfect match, 0: no match).
Background: Portable cardiopulmonary bypass(CPB) technique has been used increasingly as a potent and effective option for emergency cardiopulmonary resuscitation(CPR) because it can maintain more stable hemodynamics and provide better survival than conventional CPR techniques. This study was designed to develop a prototype of Korean portable CPB system and, by applying it to CPR, to discriminate whether it would be superior to standard open-chest CPR. Material and Method: By using adult mongrel dogs, open-chest CPR(OCPR group, n=4) and portable-CPB CPR(CPB group, n=4) were compared with respects to restoration of spontaneous circulation(ROSC), hemodynamics, effects on blood cells, blood gas patterns, biochemical markers, and survivals. Ventricular fibrillation-cardiac arrest(VF-CA) of arrest(VF-CA) of 4 minutes followed by basic life support(BLS) of 15 minutes was applied in either group, which was standardized by the protocol of American Heart Association. Then, advanced life support(ALS) was applied to either group under the support of internal cardiac massage or CPB. ALS was maintained until ROSC was achieved but not longer than 30 minutes regardless of the presence of ROSC. All of the measured values were expressed as means±SD percent change from baseline. Result: During the early ALS, higher mean arterial pressure was maintained in CPB group than in OCPR group(90±19 vs. 71±32 %; p<.05) and lower mean pulmonary arterial pressure was also maintained in CPB group than in OCPR group(105±24 vs. 146±6%; p<.05). ROSC was achieved in all dogs. Post-ROSC levels of hematocrit, RBC, and platelet were decreased and plasma free hemoglobin was increased significantly in CPB group compared to OCPR group(p<.05). Changes in blood gas patterns, lactate, and CK-MB levels were not different between groups. Early mortality was seen in 3 dogs in OCPR group(survival time 31±36 hours) and 2 in CPB group(228±153 hours, p=ns). The remainders in both groups showed prolonged survival. Conclusion: These findings indicate that portable CPB can be effective to maintain stable hemodynamics during cardiac arrest, to achieve ROSC and to prolong survival. Further study is needed to refine the portable CPB system and to meet clinical challenges.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.