• Title/Summary/Keyword: 토양함수율

Search Result 141, Processing Time 0.031 seconds

Estimation Method of Evapotranspiration over Goheung bay Wetland (고흥만 습지에서 증발산량의 산출 방법)

  • KWON, Byung Hyuk;KIM, Dong Su;KIM, Geun Hoi;KANG, Dong Hwan
    • Journal of Wetlands Research
    • /
    • v.10 no.1
    • /
    • pp.21-30
    • /
    • 2008
  • Evapotranspiration is an important factor in the energy interaction process between the surface and the air. Over a vegetable canopy, evapotranspiration was investigated by measuring the sensible heat flux, the soil heat flux and the net radiation flux. Evapotranspiration based on routine AWS data is in good agreement with that estimated from the energy balance equation except for weak wind shear less than $1s^{-1}$ and a cloudy period. Soil heat flux can be approximately to 10% of net radiation flux at the lower layer. When the slope of the saturation vapor pressure versus temperature curve ($de_s/dT$) is approximated to 1.5, the evapotranspiration can be described in function of the net radiation energy flux over Goheung bay wetland covered with the vegetable canopy, reeds.

  • PDF

Comparison of efficiency the grounding resistance enhancement materials used organic.inorganic composite (유.무기 복합재료를 이용한 접지저감제의 성능 비교)

  • Cho, D.H.;Lee, K.S.;Kim, J.W.
    • Proceedings of the KIEE Conference
    • /
    • 2004.05b
    • /
    • pp.66-72
    • /
    • 2004
  • 본 연구는 접지저감제의 성분으로 수용성 고분자의 유기물과 층상형 점토의 무기재료를 주재료하여 새롭게 개발한 새로운 형태의 접지저감제의 성능비교에 관한 것이다. 신개발의 접지저감제는 수분을 흡습하여 수분에 용해된 수용성고분자가 수분과 함께 층상형점토의 층으로 삽입되어 접지저감 성능을 발휘하게 된다. 본 연구의 유 무기 복합재료형 접지저감제는 함수율과 팽창률이 매우 우수할 뿐 아니라 300wt%의 수분을 공급 후 측정한 전기전도도도 매우 뛰어나다. 또한 환경친화적인 천연재료들이므로 인체나 환경에 매우 안전하며, 접지전극의 부식과 전식을 방지하는 기능이 매우 뛰어나 염해나 화학적으로 부식성이 높은 토양에서 큰 장점을 갖는다. 본 논문에서는 신개발의 접지저감제와 기존의 여러 접지저감의 성능을 비교 분석하였다. 이를 위해 현장의 대지저항율을 측정 분석하여 각각의 접지저감제의 접지설계에 적용하여 시뮬레이션하였으며, 시뮬레이션 결과와 현장에서 실제 시공한 측정 결과와 비교 분석하였다.

  • PDF

Assessment of the Wetland Soil Development in Constructed Wetlands using the Soil Properties of a Reference Wetland (기준습지 토양특성을 활용한 인공습지의 토양발달 평가)

  • Lee, Ja-Yeon;Kang, Dae-Seok;Sung, Ki-June
    • Journal of Wetlands Research
    • /
    • v.12 no.1
    • /
    • pp.1-14
    • /
    • 2010
  • Changes in wetland soil properties of two constructed wetlands after their constructions were compared to those of a natural wetland to determine if they could be used for the evaluation of the success of constructed wetlands and the assessment of their functions. One natural wetland as a reference wetland and two constructed wetlands(treatment wetland and experimental wetland) with different contaminant inflow characteristics were selected for this study. Major physicochemical properties of wetland soil such as soil texture, water content, pH, CEC(cation exchange capacity), organic matter content, total nitrogen, and available phosphorus were monitored to investigate the effects of inundation and accumulation of organic matters and nutrients on the wetland soil development. There was a clear difference in soil texture between the natural wetland and the constructed ones, with the high sand content in the constructed wetlands as compared to the high clay content in the natural one. Gradual increases of silt and clay contents over time were observed in the constructed wetlands. The soil of the natural wetland was higher in water content and organic matter but lower in pH than those of the constructed wetlands. The pH of the constructed wetlands reached near neutral ranges after initial increase. CEC and nutrient concentrations of the constructed wetlands seemed to be affected mainly by outside inflows of organic matter and contaminants. Concentrations of organic matter and nutrients decreased over time in the experimental wetland where surface and deep soils with different characteristics were mixed during its construction, suggesting that changes in soil properties during wetland constructions may affect the development of wetland soils or wetland biogeochemistry. This study showed that changes in physicochemical properties of soils in constructed wetlands could be used to assess the success of constructed wetlands and their functions, and also the importance of reference wetlands for the appropriate assessment.

A Study of Heavy Metal-Contaminated Soil Remediation with a EDTA and Boric acid Composite(I): Pb (EDTA와 붕산 혼합용출제를 이용한 중금속으로 오염된 토양의 처리에 관한 연구(I): 납)

  • Lee Jong-Yeol;Kim Yong-Soo;Kwon Young-Ho;Kong Sung-Ho;Park Shin-Young;Lee Chang-Hwan;Sung Hae-Ryun
    • Journal of Soil and Groundwater Environment
    • /
    • v.9 no.4
    • /
    • pp.1-7
    • /
    • 2004
  • To choose a organic acid and in-organic acid composite which is the most effective in soil-flushing process cleaning lead-contaminated sites, lead removal rates were investigated in the experiments with some organic acids; 0.01M of EDTA showed the highest lead-extraction rate ($69.4\%$) compared to the other organic acids. Furthermore, the lead removal rates were measured with 0.01M of EDIA and 0.1M of in-organic acid ; a EDTA and boric acid composite showed the highest lead-extraction rate ($68.8\%$) at pH5 compared to the other composites. As the concentration of boric acid was increased from 0.1M to 0.4M in a 0.01M of EDTA and boric acid composite, lead removal rate was decreased from $68\%\;to\;45\%$. But as the concentration of EDTA was increased from 0.01M to 0.04M in a EDTA and 0.1M of boric acid composite, permeability was decreased from $6.98{\times}10^{-4}cm/sec$ (0.01M of EDTA) to $5.99{\times}10^{-4}cm/sec$ (0.04M of EDTA). However, permeability was increased from $4.41{\times}10^{-4}cm/sec$ (0.03M of EDTA) to $6.26{\times}10^{-4}cm/sec$ (0.03M of EDTA and 0.1M of boric acid composite). indicating EDTA could increase lead dissolution/extraction rate and decrease permeability. In this system, lead remediation rate is the function of lead dissolution rate from soils and permeability of the composite into soils, and the optimized [EDTA]/[Boric acid] ratio is [0.01M]/[0.1M].

Remediation of Petroleum-Contaminated Soil by a Directly-Heated Thermal Desorption Process (직접 가열식 열탈착 공정을 이용한 유류오염토양의 정화)

  • Min, Hyeong-Sik;Yang, In-Ho;Jeon, Sang-Jo;Kim, Han-S.
    • Journal of Soil and Groundwater Environment
    • /
    • v.14 no.5
    • /
    • pp.62-70
    • /
    • 2009
  • A field soil highly contaminated with petroleum hydrocarbons (JP-8 and diesel fuels) was employed for its remediation by a lab-scale thermal desorption process. The soil was collected in the vicinity of an underground storage tank in a closed military base and its contamination level was as high as 4,476 ppm as total petroleum hydrocarbon (TPH). A lab scale directly-heated low temperature thermal desorption (LTTD) system of 10-L capacity was developed and operated for the thermal treatment of TPH contaminated soils in this study. The desired operation temperature was found to be approximately $200-300^{\circ}C$ from the thermal gravimetric analysis of the contaminated field soils. The removal efficiencies higher than 90% were achieved by the LTTD treatment at $200^{\circ}C$ for 10 min as well as at $300^{\circ}C$ for 5 min. As the water content in the soils increased and therefore they were likely to be present as lumps, the removal efficiency noticeably decreased, indicating that a pre-treatment such as field drying should be required. The analysis of physical and chemical properties of soils before and after the LTTD treatment demonstrated that no significant changes occurred during the thermal treatment, supporting no needs for additional post-treatments for the soils treated by LTTD. The results presented in this study are expected to provide useful information for the field application and verification of LTTD for the highly contaminated geo-environment.

A Development of Groundwater Level Fluctuations Due To Precipitations and Infiltrations (강우에 의한 지하수위 변동 예측모델의 개발 및 적용)

  • Park, Eun-Gyu
    • Journal of Soil and Groundwater Environment
    • /
    • v.12 no.4
    • /
    • pp.54-59
    • /
    • 2007
  • In this study, a semi-analytical model to address groundwater level fluctuations in response to precipitations and its infiltration is developed through mathematical modeling based on water balance equation. The developed model is applied to a prediction of groundwater level fluctuations in Hongcheon area. The developed model is calibrated through a nonlinear parameter estimator by using daily precipitation rates and groundwater fluctuations data of a same year 2003. The calibrated input parameters are directly applied to the prediction of groundwater fluctuations of year 2004 and the simulated curve successfully mimics the observed. The developed model is also applied to practical problems such as a prediction of a effect of reduced recharge due to surface coverage change and a induced water level reduction. Through this study, we found that recharge to precipitation ratio is not a constant and may be a function of a precipitation pattern.

An Experimental study to estimate physical properties of porous media by a permittivity method (유전율법에 따른 다공질 매질의 특성 파악을 위한 실험적 연구)

  • 김만일;니시가끼마코토
    • The Journal of Engineering Geology
    • /
    • v.13 no.4
    • /
    • pp.405-418
    • /
    • 2003
  • Measurements of volumetric water content and saturation of porous media are very important factors in understanding the physical characteristics of soil, groundwater recharge by rainfall, pollutant movement, and slope failure. To measure such physical parameters, a permittivity method using electromagnetic wave is applied and use is made of the special permittivity response of understand to water and ethanol. In particular, the estimation is required because permittivity is influenced by the nature of the underground environment. In this study, we carried out experiments on the relative dependency of soil density, temperature and salinity of standard sand and granitic weathered soil using FDR-V system (Frequency domain reflectometry with vector network analyzer) within a frequency range of 1 - 18 GHz. The results of the study showed that the dielectric constants of standard sand and granitic weathered soil increased with increased volumetric water content of soil. However, the dependency of soil density was found to be a little low. Changes of dielectric constant with temperature appeared definitely in the real part of 1 GHz. That is, the dielectric constant of real part at 1 GHz of water and standard sand increased with the rise of temperature. However, ethanol showed decreased tendency. The study also showed that dielectric constant increased with increase in salinity at imaginary part of 1 GHz. It could be concluded from this study FDR-V system can adequately measure the physical properties of soil and the degree of salinity concentration of porous media within 1 GHz frequency range using dielectric constant.

Performance Evaluation of the Field Scale Sequential Washing Process for the Remediation of Arsenic-Contaminated Soils (Field 규모 연속 토양세척공정을 이용한 비소 오염토양 정화 효율 평가)

  • Choi Sang Il;Kim Kang Hong;Han Sang-Keun
    • Journal of Soil and Groundwater Environment
    • /
    • v.10 no.6
    • /
    • pp.68-74
    • /
    • 2005
  • This study was carried out to evaluate the feasibility of field-scale sequential soil washing process for remediation on Kyongsangnamdo D mine soils which was heavily contaminated by arsonic. Arsenic concentration of untreated soils was $321\pm32mg/kg$. By applying the basic operating condition which was proposed from several pilot-scale experiments, arsenic concentration of treated soils was reduced 2.04 mg/kg ($99\%$ removal efficiency). We optimized the basic operating condition (mainly on washing solution concentration, cut-off size, and mixing ratio) to improve efficiently and economically the field-scale sequential soil washing process. The resulting optimized conditions were that solution concentration is 0.2M HCl, 1.0M HCl, 1.0M NaOH, that the cut-off size is 0.15mm (seive $\sharp$100), and that the mixing ratio is 1 3. Also, the optimized pH value for soil washing effluent treatment was 6 (33 ppb), in which the precipitation disruption caused by supersaturation of the floe did not occur. Results of TCLP tests showed that arsenic concentration from the washed gravels was 1.043 mg/L, that from soils ND (not detected), and that from filter cakes 0.066 mg/L. Also, the water content as a percentage of dewatered sludges was low $(48\%)$ and so the dewatered sludges can be disposed by landfilling. Through these results, we can concluded that tile field-scale sequential soil washing process developed in this study is adopted for remediation of arsenic-contaminated soils.

Analysis and Comparison of Physicochemical Characteristics of First-Grade Soils from Ecological and Nature Map -Focused on Igneous Rocks Area- (생태·자연도 1등급 토양의 물리화학적 특성에 대한 분석 및 비교 -화성암 지역을 중심으로-)

  • So-Jin Lee;Chang-Oh Choo;Gyo-Cheol Jeong;Jong-Tae, Kim
    • The Journal of Engineering Geology
    • /
    • v.33 no.1
    • /
    • pp.61-68
    • /
    • 2023
  • This study analyzed and compared the physicochemical characteristics of topsoil and subsoil of Grade 1 soil from an igneous rock area on the ecological and nature map. The water content and pH of the collected soil samples were measured, and X-ray fluorescence and X-ray diffraction analyses were performed. The results showed that the water content of the topsoil was higher than that of the subsoil, and its pH was more acidic than that of the subsoil. According to the X-ray fluorescence analysis results, sample I9 was closest to kaolinite, while sample I7 was most distant from kaolinite. All other samples were located between samples I7 and I9. The X-ray diffraction analysis showed that the average content of clay minerals was higher in the topsoil than in the subsoil. The most notable clay minerals produced included illite, vermiculite, kaolinite, chlorite, and gibbsite. The results of this study will be used as a basic data for topsoil restoration to convert subsoil into topsoil.

Laboratory Tests for Trichloroethylene (TCE) and Toluene Remediation in Soil Using Soil Vapor Extraction (토양증기추출(Soil Vapor Extraction)을 이용한 토양 내 Trichloroethylene (TCE)과 Toluene정화 실험)

  • 이민희;강현민
    • Economic and Environmental Geology
    • /
    • v.35 no.3
    • /
    • pp.221-227
    • /
    • 2002
  • Column experiments were performed to evaluate the removal efficiency of soil vapor extraction (SVE) iota TCE (trichloroethylene) and toluene in soil. Homogeneous Ottawa sands and real soils collected from contaminated area were used to investigate the effect of soil properties and SVE operation conditions on the removal efficiency. In column teats with two different sizes of Ottawa sand, the maximum effluent TCE concentration in a coarse sand column was 442 mg/L and 337 mg/L in a fine sand column. However, after 20 liter gas flushing, the effluent concentrations were very similar and more than 90% of initial TCE mass were removed from the column. For two real contaminated soil columns, the maximum effluent concentration decreased 50% compared with that in the homogeneous Ottawa coarse sand column, but 99% of initial TCE mass were extracted from the column within 40 liter air flushing, suggesting that SVE is very available to remove volatile NAPLs in the contaminated soil. To investigate the effect of contaminant existing time on the removal efficiency, an Ottawa sand column was left stable for one week after TCE was injected and the gas extraction was applied into the column. Its effluent concentration trend was very similar to those for other Ottawa sand columns except that the residual TCE after the air flushing showed relatively high. Column tests with different water contents were performed and results showed high removal efficiency even in a high water content sand column. Toluene as one of BTEX compounds was used in an Ottawa sand column and a real soil column. Removal trends were similar to those in TCE contaminated columns and more than 98% of initial toluene mass were removed with SVE in both column.