• Title/Summary/Keyword: 토목 구조물

Search Result 1,205, Processing Time 0.031 seconds

Evaluation of Inertial Interaction of a Multi-degree-of-freedom Structure during a Large-scale 1-g Shaking Table Test (대형 진동대 실험을 이용한 다자유도 구조물의 관성 상호작용 평가)

  • Chae, Jonghoon;Yoon, Hyungchul;Jung, Jongwon
    • Journal of the Korean Geotechnical Society
    • /
    • v.38 no.6
    • /
    • pp.17-28
    • /
    • 2022
  • The effect of the soil-structure interaction (SSI) on has been recently evaluated in shaking table tests. However, most of these tests were conducted on single-degree-of-freedom (SDOF) superstructures and a single-pile. This study investigates the inertial interaction effect of a multi-degree-of-freedom (MDOF) superstructure system with a group piles on a large-scale shaking table test. Whereas the SDOF superstructure system shows a single-frequency amplification tendency, the MDOF superstructure system exhibited amplification tendencies of the acceleration phase and frequency responses for multiple frequencies. In addition, the amplification phenomenon between the footing and the column-type superstructure exceeded that between the footing and the wall-type superstructure, indicating a greater inertial interaction effect of the column-type superstructure. The relationship between shear force and inertial force, the relative vertical and horizontal displacements on the footing was figured out. Also, the ananlysis of dynamic p-y curve at each depth was conducted. In summary, the MDOF and SDOP superstructure systems exhibited different behaviors and the column-type superstructure exerted a higher interaction effect than the wall-type superstructure.

An Experimental Evaluation for Geotechnical Properties of Geosynthetic composites by Direct Shear Test (전단시험에 의한 토목섬유 보강재의 지반 적용성 평가)

  • 조성호;최세환;차동환;류중재;전한용
    • Proceedings of the Korean Fiber Society Conference
    • /
    • 2003.04a
    • /
    • pp.267-270
    • /
    • 2003
  • 일반적으로 토목 공사에서 구조의 보강 용도로 주로 사용되는 지오그리드(geogrids)는 우수한 인장 탄성계수와 인장강력을 지니고 있어서 하중이 집중적으로 작용하는 토목 구조물에서 보강기능을 원활히 수행하는 보강재료 이지만, 비교적 큰 격자상 외관 구조를 가지므로 지오그리드를 관통하는 각종 물질, 특히 함유 수분과 세립질 토양의 이동이나 유실 등을 효과적으로 제어하지 못한다는 단점도 있어 사용상의 제약이 있다. (중략)

  • PDF

Case Study on Application of DMU to Civil Infra Structures to Improve Constructibility (토목구조물분야에서 DMU 적용을 통한 시공성개선 사례 연구)

  • Park, Kyoung-Lae;Lee, Kwang-Myong;Lee, Yoon-Bum;Lee, Chung-Hee;Lee, Tae-Young
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2011.04a
    • /
    • pp.320-323
    • /
    • 2011
  • 본 논문에서는 BIM의 기술 중 하나인 DMU(Digital Mock-Up)을 실제 프로젝트에 적용하여 업무 효율에 기여한 결과를 소개한다. 삼성물산 건설부문의 경우 DMU는 건설 프로젝트의 입찰단계 및 시공계획 단계에서 적용되어 많은 성과를 거두었다. 입찰단계의 경우 대상 프로젝트의 교량, 터널 등의 구조물을 실제와 같은 지형조건 및 설계 조건으로 모델링하여 프로젝트의 개요 파악, 정보의 공유, 선정된 공법의 효과 분석 등에 적용하였으며 시공단계에서는 주로 복잡한 구조물의 철근 간섭 검토 및 효율적인 배근 방법 분석을 위한 도구로 사용되었다. 적용결과 공기단축, 원가절감, 시공성 향상에 기여하였으며, DMU는 향후 프로젝트 관리도구로 통합되어 구조물공사의 원가절감 및 생산성 향상에 기여할 것으로 예상된다.

  • PDF

Using Air-coupled Sensors (ASC) for Non-contact Non-destructive Evaluation of Concrete in Structures (Air-coupled 센서를 이용한 비접촉 콘크리트 비파괴 검사법)

  • Kee, Seong Hoon
    • Magazine of the Korea Institute for Structural Maintenance and Inspection
    • /
    • v.17 no.1
    • /
    • pp.48-59
    • /
    • 2013
  • 응력파의 기반한 비파괴 검사법은 비교적 실험 절차 및 실험에 필요한 장비가 단순하고, 인체에 해가 없으며, 비용이 저렴한 특성을 갖고있다. 따라서 건축/토목 구조물의 비파괴 검사에 매우 효과적인 방법으로 알려져 있다. 하지만 기존의 가속도계, 변위계, 지오폰과 같은 부착 센서를 사용할 경우 표면 처리, 센서의 부착 및 이동에 따른 추가적인 시간이 소요되고, 센서와 구조물의 불완전한 커플링으로 인한 측정 결과의 신뢰성 및 일관성을 유지하지 어렵다는 문제를 발생시킨다. 최근 이러한 문제의 해결책으로 Air-coupled sensor (ACS)의 사용이 각광받고 있으며, 여러 연구자들에 의해 ACS의 가능성 및 실용성이 증명되고 있다. 기존의 접촉센서와 비교하여 ACS를 사용했을 때 얻을 수 있는 가장 큰 장점은 센서의 커플링 문제를 근본적으로 해결하여 신뢰도가 높고 일관적인 측정이 가능하고, 대형 건축/토목 구조물의 표면을 음향스캔하여 결과를 신속하게 처리하여 실시간으로 시각화 할 수 있다는 점이다. 이론적으로 ACS를 이용하여 측정하는 물리값은 콘크리트 내부에서 발생된 응력파의 일부가 공기중으로 전파된 누설파 (Leaky wave)이다. 콘크리트 비파괴 검사에 주로 사용하는 100 kHz이하의 저주파를 측정할 경우 일반적으로 콘텐서마이크가 ACS로 사용될 수 있다. 기존 연구자들은 실험 및 이론적 연구를 통하여 응력파에 기반한 비파괴 방법에서 ACS가 기존의 접촉 센서를 대체할 수 있다는 점을 보여주고 있다. 현재 미국에서는 연방 도로청 (FHWA) 및 국가표준기술연구소 (NIST)의 연구비 지원으로 ACS의 실용성을 높이기 위하여 최적화된 음향반사판의 설계를 통한 ACS 의 민감도를 높이기 위한 연구, 다채널 센서 배열 및 데이터 통합을 위한 새로운 알로리즘 개발, 자동화 및 로봇 기술과 융합과 같은 연구가 활발히 진행되고 있다. 멀지 않은 미래에는 ACS를 장착한 무인 로봇이 다양한 종류의 건축/토목 구조물의 건전도를 평가하기 위하여 종횡무진 활약하는 모습을 현실 속에서 볼 수 있을 것이라 기대한다.

  • PDF

Response Analysis of Frame Structures with the Consideration of Tunnel Construction (프레임구조물의 터널시공에 따른 거동분석)

  • Son, Moorak;Park, Jaehyun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.3C
    • /
    • pp.121-127
    • /
    • 2012
  • This paper investigates the response of frame structures with the consideration of tunnel construction (ground loss) conditions. The response of four-story open frame structure and block-infilled frame structures, which are subjected to tunnelling-induced ground movements, has been investigated in different construction (ground loss) conditions using numerical analysis. The open frame structure has been modelled as an elastic structure, while the block-infilled frame structure has been modelled to have real cracks when the shear and tensile stress exceed the maximum shear and tensile strength. The response of the two different frame structures has been investigated in terms of construction (ground loss) conditions considering the magnitude of deformations and cracks in structures. In addition, the damage levels, which are possibly induced in the structures, has been provided in terms of construction (ground loss) conditions using the state of strain damage estimation criterion (Son and Cording, 2005). The results of this study will provide a background for better understandings for controlling and minimizing building damage on nearby frame structures due to tunnelling-induced ground movements.

The Phase Difference Effects on 3-D Structure of Wave Pressure Acting on a Composite Breakwater (혼성방파제에 작용하는 3차원 파압구조에 미치는 위상차의 영향)

  • Hur, Dong-Soo;Yeom, Gyeong-Seon;Bae, Ki-Seong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.5B
    • /
    • pp.563-572
    • /
    • 2006
  • In designing the coastal structures, the accurate estimation of wave forces on them is very important. Recently, the empirical formulae such as Goda formula are widely used to estimate wave forces, as well as 2-D hydraulic and numerical model tests. But, sometimes, these estimation methods mentioned above seem to be unreasonable to predict 3-D structure of wave pressure on the coastal structures with 3-D plane arrangement in the real coastal area. Especially, in case of consideration of phase difference at harbor and seaward sides of the large-sized coastal structures like a composite breakwater, it is easily expected that the real wave pressures on each section of coastal structure have 3-D distribution. A new numerical model of 3-D Large Eddy Simulation, which is applicable to permeable structure, is developed to clarify the 3-D structure of wave pressures acting on coastal structure. The calculated wave forces on 3-D structure installed on the submerged breakwater show in good agreement with the measured values. In this study, the composite breakwater is adopted as a representative structure among the large-sized coastal structures and the 3-D structure of wave pressures on it is discussed in relation to the phase difference at harbor and seaward sides of it due to wave diffraction and transmitted wave through rubble mound.

Efficient Analysis for a Three-Dimensional Multistory Structure with Wings (여러 Wing들로 구성된 3차원 구조물의 효율적인 해석모델)

  • Moon, Seong Kwon;Lee, Dong Guen
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.14 no.3
    • /
    • pp.429-438
    • /
    • 1994
  • Three-dimensional analyses of multistory structures with wings using finite element models require tedious input data preparation, longer computation time. and larger computer memory. So this study lays emphasis on the development of efficient analysis models for a three-dimensional multistory structure with wings, including in-plane deformation of floor slabs. Since a three-dimensional multistory structure with wings is regarded as a combination of wing structures and their junction in this study, the proposed analysis models are easily applicable to multistory structures with plans in the shape of letters Y, U, H, etc. Dynamic analyses results obtained using proposed models are in excellent agreement to those acquired using three-dimensional finite element models in terms of natural vibration periods, mode shapes and displacement time history.

  • PDF

콘크리트 표면차수벽형 석괴댐의 균열원인 분석

  • 김광일;장동일;채원규;원일석;조광현;손영현
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 2000.11a
    • /
    • pp.423-428
    • /
    • 2000
  • 콘크리트구조물은 비교적 경제적인 시공이 가능하며 구조물의 수명 또한 안정적인 관계로 널리 사용되어 왔다. 그러나 최근 콘크리트의 고강도화 및 설계의 최적화에 따른 부재단면의 최소화 경향, 새로운 공법의 적용 등에 따른 균열문제가 빈번하게 대두되고 있는 실정이다. 특히 다양한 토목구조물중 매스콘크리트구조물, 벽체구조물 등과 같은 종류에서의 균열문제가 자주 언급되고 있으며, 균열에 따른 심리적 불안감과 콘크리트 내구성의 저하, 궁극적으로는 구조물의 안전성에 대한 불안심리를 가증 시키고 있다.(중략)

  • PDF

Reduction of Differential Settlements due to Deep Excavation Using the Micro-piling Method (마이크로 파일을 이용한 가설 벽체 인접 구조물의 침하 억제에 관한 연구)

  • Huh, In-Goo;Hwang, Tae-Hyun;Lee, Sang-Ryeong;Shin, Jong-Ho;Kwon, Oh-Yeob
    • Journal of the Korean Geotechnical Society
    • /
    • v.24 no.10
    • /
    • pp.71-81
    • /
    • 2008
  • Wall displacements caused by earth pressure, rainfalls, rise in ground water level, inappropriate deep excavation and structural defects of the wall may produce differential settlements to existing buildings, which often result in damages and/or collapses of the building structures. In this case, measures to protect the walls and nearby structures would be required. One of the recent measures to reduce differential settlements and protecting walls is to reinforce the ground using micro-piles. In this study physical model tests were carried out to evaluate the performance of the micro-pile method. It is revealed that reduction of the settlement was maximized when the length of micro-pile is twice of the foundation width, distance between piles is twice of the pile diameter and the distance to wall is one tenth of the foundation width. Based on the test results some design recommendations were made.