• 제목/요약/키워드: 토모그래피-레이저흡수분광법

검색결과 4건 처리시간 0.019초

레이저흡수분광 토모그래피법에서의 레이저빔의 최적 배치에 관한 연구 (Study on Optimal Arrangements of Laser Beams in Tunable Diode Laser Absorption Spectroscopy Based Tomography (TDLAST))

  • 김경원;윤동익;최두원;조경래;도덕희
    • 한국수소및신에너지학회논문집
    • /
    • 제28권6호
    • /
    • pp.729-737
    • /
    • 2017
  • The measurement accuracy of Tunable Diode Laser Absorption Spectroscopy based Tomography (TDLAST) for the temperature and concentration fields are dependant upon the arrangement method of the used laser beams. This paper reports on the optimization of laser beam arrangements using phantom data. It has been verified that the measurement error of the TDLAST decreased with increase of laser beam numbers. Further, it has been confirmed that perpendicular arrangements between the horizontal and the vertical laser beams without additional diagonal laser beams shows the minimum measurement errors.

CT-레이저흡수분광법(TDLAS) 성능향상을 위한 레이저 선폭확장 함수 최적 계수 선정에 관한 연구 (Study on Optimal Coefficients of Line Broadening Function for Performance Enhancements of CT-TDLAS)

  • 최두원;조경래;;백태실;도덕희
    • 한국수소및신에너지학회논문집
    • /
    • 제27권6호
    • /
    • pp.773-782
    • /
    • 2016
  • The performance of the CT-TDLAS (computed tomography-tunable diode laser absorption spectroscopy) is strongly dependent upon the line broadening functions. The line of the laser beam used in the TDLAS is scattered by the natural broadening, the collisional broadening and the doppler broadening. The influence of the natural broadening to the experimental spectra obtained in the TDLAS is negligible. The influences of the collisional broadening and the doppler broadening to the experimental spectra are relatively large, in high pressure gas flows and in high temperature low pressure gas flows, respectively. In this study, optimal coefficients are proposed for the doppler broadening function by using the experimental data obtained in a flat burner test. The optimal coefficients were ${\gamma}_j=0.16$ and n=0.37. Using these coefficients, the temperature and concentration distributions at the engine exhaust gas pipe have been calculated showing their validities.

컴퓨터토모그래피 레이저흡수분광법(CT-TDLAS) 기반 2차원 온도분포 산정 Two-Ratios-of-Three-Peaks (2R3P) 알고리듬 개발 (2D Temperature Measurement of CT-TDLAS by Using Two-Ratios-of-Three-Peaks Algorithm)

  • 최두원;조경래;심준환;;김동혁;도덕희
    • 한국수소및신에너지학회논문집
    • /
    • 제27권3호
    • /
    • pp.318-327
    • /
    • 2016
  • In order to improve the performance of temperature field measurements by CT-TDLAS (Computer Tomography Tunable Diode Laser Absorption Spectroscopy), a new reconstruction algorithm, named two-ratios-of-three-peaks method is proposed in this paper. Further, two methods for selecting appropriate initial values of the iterative calculation of CT-TDLAS are proposed. One is MLOS (multiplicative line of sight) method and the other one is ALOS (additive line of sight) method. Two-ratios-of-three-peaks (2R3P) algorithm combined with MART (multiplicative algebraic reconstruction technique) is finally developed for the enhancements of reconstructive calculations. The results have been compared with those obtained by the conventional one-ratio-of-two-peaks (1R2P) algorithm. In order to evaluate the performance of this algorithm, numerical test has been performed using phantom Gaussian temperature distributions with $11{\times}11$ square mesh. The performance of the constructed algorithm has been demonstrated by comparing the results obtained in actual burner experiments with those obtained by thermocouples. It has been verified that 2R3P algorithm with MART and MLOS showed best performance than that of 1R2P algorithm.

레이저흡수분광법(TDLAS) 기반 가스온도분포 산정을 위한 상호상관계산 알고리듬 개발 (Developments of a Cross-Correlation Calculation Algorithm for Gas Temperature Distributions Based on TDLAS)

  • 최두원;김광남;조경래;심준환;김동혁;;도덕희
    • 한국수소및신에너지학회논문집
    • /
    • 제27권1호
    • /
    • pp.127-134
    • /
    • 2016
  • Most of reconstruction algorithms for the calculation of temperature distributions in CT (computed tomography)-TDLAS (tunable diode laser absorption spectroscopy) are based upon two-line thermometry method. This method gives unstable calculation convergence due to signal noise, bias error, and signal mis-matches. In this study, a new reconstruction algorithm based on cross-correlation for temperature calculation is proposed. The patterns of the optical signals at all wave lengths were used to reconstruct the temperature distribution. Numerical test has been made using phantom temperature distributions. Using these phantom temperature data, absorption spectra for all wave lengths were constructed, and these spectra were regarded as the signals that would be obtained in an actual experiments. Using these virtually generated experimental signals, temperature distribution was once again reconstructed, and was compared with those of the original phantom data. Calculation errors obtained by the newly proposed algorithm were slightly large at high temperatures with small errors at low temperature.