• 제목/요약/키워드: 텐던

Search Result 159, Processing Time 0.022 seconds

Mechanical Behavior of Anchorage Zones in Prestressed Concrete Members with Single and Closely-Spaced Anchorages (단일텐던 및 복수텐던이 설치된 프리스트레스트 콘크리트 부재의 정착부 거동 연구)

  • Oh, Byung Hwan;Lim, Dong Hwan;Yoo, Seung Woon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.14 no.6
    • /
    • pp.1329-1339
    • /
    • 1994
  • The purpose of present study is to explore the mechanical behavior of anchorage zones in prestressed concrete members with single and closely-spaced multiple tendon anchorages. The cracking loads and local stress distributions at these anchorage zones are studied. To this end, a series of experiments have been conducted. From this study, it is found that the failure of anchorage zones of the closely-spaced multiple tendon members is initiated by cracking along the tendon path and that the tensile stresses arising in the vicinity of anchorage zone of the first tendon are reduced due to additional compression of the second tendon. This results in the increase of cracking capacity of the member. The effects of multiple tendons are presented in the form of strain distribution and cracking load comparisons.

  • PDF

Tensile Stress Measurement of Tendon with Wiedemann Effect (Wiedemann 효과를 이용한 텐던의 인장력 측정)

  • Kang, Sunju;Son, Derac;Joh, Changbin;Lee, Jungwoo
    • Journal of the Korean Magnetics Society
    • /
    • v.26 no.4
    • /
    • pp.133-136
    • /
    • 2016
  • In this study, we have constructed a measuring system to investigate tensile stress of tendons, which is employed in bridges, by means of the magnetic non-destructive testing (NDT) method. For the twisted 7-strands tendon, we have used Wiedemann effect. An ac current was applied to the tendon and voltage induced from Search Coil on Tendon (SCT) under applying tensile stress was measured. The measuring system consists of tensile stress applying apparatus up to 2 GPa, and ac current supply to apply current to the tendon directly to magnetize the tendon. We have invested two kinds of tendon which were produced by different companies for testing with constructed measuring system. Voltage induced from SCT was decreased up to 1.5 GPa linearly and two kinds of tendon which were produced by different companies shows similar trends. Thus, Wiedemann effect was also applicable to measure tensile stress of tendon by means of magnetic NDT.

Experimental Relationship between Applied Stress and Elastic Velocity of Bonded Tendon (부착식 텐던의 도입 긴장응력과 탄성파속도와의 실험적 관계)

  • Kim, Byeong-Hwa;Kim, Soo-Jin;Yeo, Keum-Soo
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2010.04a
    • /
    • pp.649-652
    • /
    • 2010
  • 본 연구는 부착식 PSC 텐던의 긴장력를 비파과적인 방법으로 추정하기 위한 방법을 소개한다. 제안기법은 텐던 정착단 양쪽 단부에 가속도계를 부착하고, 가속도신호의 도달 속도를 계측함으로써 텐던의 긴장력을 추정하는 방법이다. 가속도신호의 도달속도를 산성하기 위하여 신호의 상호상관을 이용하는 방법을 제안한다. 제안기법은 도입장력이 다른 6개의 8m 부착식 PSC 시험체를 통하여 검증되었다.

  • PDF

Feasibility Study of Estimating Prestress Force of Grouted Tendons (종진동특성을 이용한 부착식 텐던의 긴장력 추정 타당성 연구)

  • Kim, Byeong Hwa;Jang, Jung Bum;Lee, Hong Pyo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.2A
    • /
    • pp.103-111
    • /
    • 2010
  • A feasibility study for nondestructively estimating prestress force of a grouted tendon using axial vibrations has been investigated. Total eight prestressed concrete beams with different stress levels have been specially designed and constructed for this investigation. The various axial vibration tests have been conducted in order to extract the dynamic characteristics of the prestressed concrete beams. It turns out that the axial frequency, elastic wave velocity and elastic modulus are nonlinearly increased as the prestress force level increases. It seems that the axial vibration characteristics of the existing grouted tendons are a feasible indicator for the identification of their tensile force.

Longitudinal Vibration Mechanism of Grouted PSC Tendon (부착식 PSC 텐던의 종진동 메카니즘)

  • Kim, Byeong Hwa;Jang, Jung Bum;Lee, Hong Pyo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.3A
    • /
    • pp.261-267
    • /
    • 2011
  • This study reveals the longitudinal vibration mechanism of tendon embedded in a prestressed concrete. The extensional and torsional displacements of the strand are coupled, and the applied prestress level of tendon affects not only axial rigidity but also torsional rigidity. Measuring the elastic wave velocity of tendon, the applied prestress level of tendon could be evaluated. This is because the elastic wave velocity is a function of extensional and torsional rigidity. Using the experimental results for the six prsteressed concrete beams with different prestress levels, the longitudinal vibration mechanism and the effect of prestress level have been examined. To estimate the system ridigities of tendon, a system identification algorithm has been newly developed. The estimated system rigidities have been compared with the available results of related previous study.

Stress Distribution on Construction Joint of Prestressed Concrete bridge Members with Tendon Couplers (텐던커플러를 사용한 프리스트레스트 콘크리트 교량부재의 이음부 응력분포 특성)

  • 오병환;채성태;김병석;이만섭
    • Journal of the Korea Concrete Institute
    • /
    • v.13 no.1
    • /
    • pp.1-8
    • /
    • 2001
  • Recently, prestressed concrete(PSC) bridge structures with many repetitive spans have been widely constructed using the segmental construction method in many countries. In these segmentally constructed PSC bridges, there exist many construction joints which is required coupling of tendons or overlapping of tendons to introduce continuous prestress through several spans of bridges. The purpose of this paper is to investigate in detail the complicated stress distributions around the tendon coupled joints in prestressed concrete girders. To this end, a comprehensive experimental program has been set up and a series of specimens have been tested to identify the effects of tendon coupling. The present study indicates that the longitudinal and transverse stress distributions of PSC girders with tendon couplers are quite different from those of PSC girders without tendon couplers. It is seen that the longitudinal compressive stresses introduced by prestressing are greatly reduced around coupled joints according to tendon coupling ratios. The large reduction of compressive stresses around the coupled joints may cause deleterious cracking problems in PSC girder bridges due to tensile stresses arising from live loads, shrinkage and temperature effects. The analysis results by finite element method correlate very well with test results observed complex strain distributions of tendon coupled members. It is expected that the results of this paper will provide a good basis for realistic design guideline around tendon coupled joints in PSC girder bridges.

Tensile Stress Measurement of Tendon by Means of Non-contact Yoke Method (Yoke를 사용한 비접촉 방법에 의한 텐던 인장응력 측정)

  • Kang, Sunju;Son, Derac;Joh, Changbin;Lee, Jungwoo
    • Journal of the Korean Magnetics Society
    • /
    • v.26 no.1
    • /
    • pp.19-23
    • /
    • 2016
  • In this study, we have constructed a measuring system to investigate tensile stress measurement of tendons, which is employed in bridges, by means of the non-destructive and non-contact method. The measuring system consists of tensile stress applying apparatus up to 2 GPa, and power supply for ac and dc current to tendon directly to magnetize tendon in circular direction and to coil wound on yoke to magnetize tendon in axial direction. We have used two kinds of tendon, which were produced by different companies, using the measuring system constructed in this work. Two kinds of experiments are carried out in this work; $1^{st}$ experiment : ac current was applied to the tendon and dc current was applied to coil wound on the yoke, and voltage induced from search coil wound on yoke (SCY) was measured and $2^{nd}$ experiment : dc current was applied to the tendon and ac current was applied to coil wound on the yoke, and voltage induced from search coil on tendon (SCT) was measured. In case of $1^{st}$ experiment, voltage induced from SCY was changed below 200MPa tensile stress but the voltage was not increased above 200 MPa. In case of $2^{nd}$ experiment, voltage induced from SCT was decreased up to 1.5 GPa linearly. We expect that $2^{nd}$ experiment could be applied to the non-destructive testing of tensile stress measurement of tendon.

Effect of Applied Tensile Stress of Bonded PSC Tendon on Longitudinal Vibration Mechanism (부착식 PSC 텐던의 도입 긴장응력이 종진동 메카니즘에 미치는 영향)

  • Kim, Byeong-Hwa;Kim, Soo-Jin;Yeo, Keum-Soo;Cho, Seung-Je
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2011.04a
    • /
    • pp.392-395
    • /
    • 2011
  • 본 논문은 부착식 PSC 텐던에 도입된 긴장응력이 종진동 메카니즘에 미치는 영향을 소개한다. 텐던의 종방향 변형과 비틀림 변형은 상호 연동하여 거동하고, 텐던에 도입된 긴장응력은 축강성과 비틀림 강성에 영향을 미친다. 따라서 텐던의 탄성파 속도는 도입된 긴장응력의 크기에 따라서 변한다. 실험적 검증을 위하여 도입 긴장응력이 다른 6개의 부착식 PSC 시험체에 대한 종진동 실험이 수행되었다. 실험결과로부터 도입 응력과 탄성파 속도와의 역학적 관계를 확인하였으며, 기존 문헌의 실험결과와 비교하였다.

  • PDF

A Study of the Tendon Profile of a PSC Continuous Beam Able to Resist the Negative Bending Moment of Continuous Intergirders (거더 연속부의 부모멘트 제어에 효과적인 PSC 연속보의 텐던 배치에 관한 연구)

  • Kim, Eui Hun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.41 no.6
    • /
    • pp.617-625
    • /
    • 2021
  • The problems associated with the continuous method of a domestically improved prestressed concrete (PSC) girder and the bending moment of a continuous tendon were studied. Based on the results, a continuous tendon model was proposed that can resist the negative bending moment of an intergirder. This model lowers the anchorage of the continuous tendon as far as possible under the girder, and extends the tendon section arranged under the girder. This method reduces the PS's bending moment in the middle of the span, but maximizes it in the intergirder. This continuous tendon model can offer a suitable method for continuity before manufacturing a composite, which requires a higher design bending moment in the intergirder than in the middle of the span.

Effect of the Prestressing Tendon Arrangement in the Wall of Circular Storage Tank (원형탱크 구조물 벽체의 텐던 배치에 대한 고찰)

  • 전세진;정철헌;진병무
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.5
    • /
    • pp.759-765
    • /
    • 2002
  • Prestressing tendons in the wall of circular storage tank are investigated from the viewpoint of equivalent load method. Special attention is paid to the effectiveness of eccentricities of the hoop and vertical tendons. Local effect at the bent Point of vertical tendon in the wall with varying thickness is examined. Some aspects which are frequently overlooked or misinterpreted in the conventional analyses of vertical tendons are discussed. Numerical examples are presented to emphasize the significance of accurate analysis of the vortical tendon in practice. It is expected that the equivalent load method can be effectively used to simplify the analysis of tendons in the circular wall and to minimize the errors.