• Title/Summary/Keyword: 테플론

Search Result 62, Processing Time 0.022 seconds

Wall Contamination of Teflon Bags Used as a Photochemical Reaction Chamber of Ambient Air (실제 대기의 광화학 반응 챔버로 사용되는 테플론 백의 오염도 평가)

  • Lee, Seung-Bok;Bae, Gwi-Nam;Lee, Young-Mee;Moon, Kil-Choo
    • Particle and aerosol research
    • /
    • v.9 no.3
    • /
    • pp.149-161
    • /
    • 2013
  • Experiments on photochemical reactions of purified air alone in an indoor smog chamber were carried out after flushing Teflon bags with purified air for many hours in order to check the level of contamination on the chamber wall. Ozone concentrations were linearly increased from <4 ppb up to about 8 ppb with irradiation time for four hours. Outgassing of NOx from the chamber wall was found to be less than 1 ppb. New ultrafine particles were formed and grown up to about 70 nm during the photochemical reactions, and then total number and mass concentrations of particles were increased from <10 particles/$cm^3$ up to about 4,000 particles/$cm^3$ and $1.3{\mu}g/m^3$, respectively. The wall conditions of these Teflon bags flushed with purified air might not severly affect the chamber experimental results for photochemical reactions of polluted urban ambient air. The difference of gaseous species between two chambers was 2.4 ppb of ozone at most, indicating that the wall cleaning performance of two chambers was nearly similar.

4-Branch Waveguide Thermo-Optic Switch With Unequal Width Heaters (크기가 다른 전극폭을 갖는 4분기 광도파로형 열광학스위치)

  • Song, Hyun-Chae;Rhee Tae-Hyung;Shin, Sang-Yung
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.37 no.6
    • /
    • pp.57-63
    • /
    • 2000
  • A multi-branch thermo-optic switch has a problem that driving powers in the switching states are different from each other; the power consumption for the inner output port is more than twice as large as that form the outer output port. In this pater, to solve this problem unequal width heaters and the waveguide structure with a thin overcladding layer are proposed in a four-branch thermo-optic switch. The proposed structure is fabricated with the polymer materials with high index difference, Teflon and polyimides. The fabricated device was measured at the wavelength of 1550 nm. The measured characteristics exhibit the smaller difference in the power consumption between the switching states and the driving power les than the previous four-branch thermo-optic switch with equal width heaters. As for the device performance, the crosstalk is better than - 16 dB at about 310 ~ 390 mW, the insertion loss is 4.7 dB, and the switching time is less than 1 ms.

  • PDF

Fabrication and Characterization of Porous Silicon-based Urea Sensor Syst (다공질 실리콘을 이용한 요소검출용 바이오 센서 제작)

  • Jin, Joon-Hyung;Kang, Chul-Goo;Kang, Moon-Sik;Song, Min-Jung;Min, Nam-Ki;Hong, Seok-In
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.2003-2005
    • /
    • 2002
  • 바이오 마이크로 시스템 및 바이오 MEMS 분야, 특히 실리콘을 기질로 하는 바이오 센서 제작에서 반도체 공정 기술은 센서의 대량 생산과 초소형화를 위해서 반드시 필요한 기술이다. 그러나, 감지전극의 마이크로화에 따른 센서의 감도 및 안정성 저하 문제는 해결해야 할 과제이다. 최근, 다공질 실리콘이 갖는 대면적이 실리콘 기질과 생체 고분자 (예: 단백질, 핵산 등) 간의 결합력을 향상시킬 수 있음이 알려지면서, 바이오 센서 분야에서, 새로운 형태의 드랜스듀서 재료로서의 다공질 실리콘에 대한 논의가 활발히 전개되고 있으며 또한, ISFET (Ion-Selective Field-Effect Transistors) 와는 달리 다공질 실리콘 층은 저항이 크기 때문에 센서 제작 과정에서의 부가적인 절연막을 필요로 하지 않는다. 본 연구에서는, 백금을 증착한 다공질 실리콘 표면에 전도성 고분자로서 Polypyrrole (PPy) 필름과 생체 고분자 물질로서 Urease를 각각 전기화학적으로 흡착하였다. 다공질 실리콘 층의 형성을 위해 테플론 소재의 전기화학 전지에 불산 (49%), 에탄올 (95%), $H_2O$ 혼합 용액을 넣고 실리콘 웨이퍼에 일정시간 수 mA의 산화 전류를 흘려주었으며, 약 $200{\AA}$의 티타늄 박막과 $200{\AA}$의 백금 박막을 RF 스퍼터링하여 작업 전극을 제작하였고, 백금 박막 및 Ag를 기화 증착하여 제작한 Ag/AgCl 박막을 각각 상대 전극과 기준전극으로 하였다. 박막 전극의 표면 분석을 위해 SEM (Scanning Electron Microscopy), EDX (Energy Dispersive X-ray spectroscopy) 등을 이용하였다. 제작된 요소 센서로부터 요소 농도 범위 0.01 mmol/L ${\sim}$ 100 mmol/L에서 약 0.2 mA/decade의 감도를 얻었다.

  • PDF

Bronchial Foreignbody after Right Lower Lobe Lobectomy (우측 폐 하엽 절제술 후 발생한 기관지 이물질)

  • Lee, Hyoung-Chae;Han, Il-Yong;Jun, Hee-Jae;Lee, Yang-Haeng;Hwang, Youn-Ho;Cho, Kwang-Hyun
    • Journal of Chest Surgery
    • /
    • v.41 no.2
    • /
    • pp.281-284
    • /
    • 2008
  • Bronchial foreign bodies commonly occur through aspiration or inhalation. Here we present a very rare case of migration of a non-metallic foreign body into the bronchus 5 years after lobectomy. The foreign body, a Teflon pellet used to control parenchymal bleeding in the lung, was removed by a bronchofiberscope. Although the mechanism of migration remains unknown, our case and a previous Japanese case provide evidence that non-metallic foreign bodies can migrate from the lung parenchyma to the bronchus.

Ln-resin and HIBA Method for La-Ce and Sm-Nd Isotope Measurement (La-Ce 및 Sm-Nd 동위원소계 측정을 위한 란탄-레진법과 HIBA(Hydroxy Isobutyric Acid)분리법의 상호비교)

  • Lee, Seung-Gu;Lee, Hyomin;Asahara, Yoshihiro;Lee, Mi-Jeong;Choo, MiKyeong;Lee, SeungRyeol
    • The Journal of the Petrological Society of Korea
    • /
    • v.21 no.4
    • /
    • pp.431-439
    • /
    • 2012
  • A column chemistry is the most useful tools for isolating the elements of interest in isotope geochemistry. Here we introduce the chemical experimental procedure for Sm, Nd, La and Ce separation such as Teflon powder or Ln-resin method using HDEHP of KIGAM, KBSI, KOPRI and ${\alpha}$-HIBA(${\alpha}$-Hydroxy Isobutyric acid) method of Nagoya University, Japan. This technical report will provide an useful information in selecting the experiment method for rare earth element isotope system study such as Sm-Nd and La-Ce isotope system.

Design and Fabrication of Active Type Patch Antenna for S-DMB (위성 DMB용 능동형 패치 안테나의 설계 및 제작)

  • Yun, Li-Ho;Kim, Byung-Mun
    • 전자공학회논문지 IE
    • /
    • v.45 no.4
    • /
    • pp.54-59
    • /
    • 2008
  • In this paper, circularly polarized patch antenna with 2-stage LNA for the reception of S-DMB is presented. It used teflon didelectric substrate of ${\in}_r$=2.2 and the size is $40{\times}40{\times}15\;[mm]$. Experimental results of fabricated antenna show that bandwidths of input return loss and axial ratio are about 22 [MHz] and 25 [MHz]. Input return loss, output return loss, gain, and noise figure of the fabricated 2-stage LNA are $S_{11}$=-14 [dB], $S_{22}$=-18 [dB], $S_{21}$=26.8 [dB], and NF=1.14 [dB] respectively. The fabricated active type antenna has total gain of 30.4 [dB] at 2.642 [GHz].

Electrically Small Square Loop Antenna with SRR (Split Ring Resonator) Cover Structure (SRR (Split Ring Resonator) 덮개 구조를 갖는 전기적 소형 정사각형 루프 안테나)

  • Kim, Yong-Jin;Kim, Jung-Han;Lee, Hong-Min
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.45 no.6
    • /
    • pp.52-58
    • /
    • 2008
  • In this paper, electrically small square loop antenna with SRR (Split Ring Resonator) cover structure is built and tested. The proposed antenna has very small size, ka = 0.34 by Chu limit. The experimental result shows that the resonant frequency and impedance bandwidth($VSWR{\leq}2$) are 906MHz and 5.8MHz (901.7 - 907.5MHz), respectively. The proposed antenna is matched and designed by equivalent circuit model. The proposed antenna is fabricated simple structure without additional matching network and printed on a Teflon substrate without ground plane. Therefore, it has advantages of low cost, small size, and light weight and will be applied to wireless communication systems where small antennas are required.

Experimental Study on Coating Corrosion Characteristics of Heat Exchanger for Sea Water (해수용 열교환기의 코팅 부식특성 실험연구)

  • Kwon, Young-Chul;Kim, Ki-Young;Huh, Cheol;Cho, Meang-Ik;Kwon, Jeong-Tae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.9
    • /
    • pp.4117-4123
    • /
    • 2013
  • In the present study, coating corrosion characteristics of the heat exchanger for sea water are experimentally investigated. Coating types by a teflon, an electrodeposition and a ceramic+silicon were tested and compared with the corrosion characteristics of an aluminum. For the acceleration of corrosion by sea water, the temperature of sea water $70^{\circ}C$ and the concentration of salt 3.5% were considered. And the specimens were immersed in sea water during 9 weeks. Coating corrosion characteristics were measured by using the impedance method and SEM. Experimental results showed that polarization resistances obtained from Bode plot were related to the corrosion resistance of coating types, and the corrosion resistance of double coating were maintained during 4 weeks. From SEM photograph, we saw that blisters was generated on the interface between metal and coating.

THERMAL CHANGE AND MICROHARDNESS IN CURING COMPOSITE RESIN ACCORDING TO VARIOUS CURING LIGHT SYSTEM (광중합기에 따른 복합레진 중합시 온도 변화와 미세경도에 관한 연구)

  • Lee, Dong-Jin;Kim, Dae-Eop;Yang, Yong-Sook;Lee, Kwang-Hee
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.3
    • /
    • pp.391-399
    • /
    • 2004
  • The purpose of this study was to compare curing efficiency of newly developed curing units to traditional halogen curing unit by measuring thermal change and surface microhardness according to curing light system. Materials and mathods : The types of curing units were traditional low intensity halogen light(Optilux 360), plasma arc light(Flipo), low heat plasma arc light(Aurys), low intensity LED(Starlight), and high intensity LED(Freelight2). Temperature at the tip of light guide was measured by a digital thermometer using K-type thermocouple. And after resin was filled to 2, 3, 4mm teflon mold, bottom temperature measured during curing. After 24 hours, microhardness of top surface and bottom surface of each resin specimen were measured. Results : The result of this study can be summarized as follows, 1. As measuring temperature of curing unit tips, Flipo is the highest as $52.4^{\circ}C,\;Freelight2(37.86^{\circ}C),\;Optilux360(32.68^{\circ}C),\;Aurys(32.34^{\circ}C),\;and\;Starlight(26.14^{\circ}C)$ were followed. 2. Flipo and Freelight2 were the highest similarly and Optilux360 and Aurys were similarly next and Starlight was lowest in temperature of bottom surface of resin mold. 3. Microhardness of top surface were generally similar, and Aurys was relatively low. 4. Optilux 360 and Freelight2 were the highest, and Flipo, Starlight, and Aurys were followed in microhardness of bottom surface. Conclusions : The results suggest that careful use of Flipo and Freelight2 might be able to cure greater depth of resin composite and do not cause thermal problems than other curing units.

  • PDF

Teflon Felt Strip Mitral Valve Repair as an Alternative to Expensive Commercial Rings (테플론 펠트를 사용한 승모판막 성형술: 고가의 상업적 제품에 대한 대체물로 가능한가?)

  • Park, Kook-Yang;Jeon, Yang-Bin;Park, Chul-Hyun
    • Journal of Chest Surgery
    • /
    • v.41 no.2
    • /
    • pp.216-222
    • /
    • 2008
  • Background: Prosthetic annuloplasty rings are used for the reconstruction of the mitral valve annulus. However, there is controversy over the best ring to use for reconstruction. In this study, we evaluated the long term result of using a Teflon felt strip as an alternative to commercial rings. Material and Method: From 1996 to 2007, we enrolled 47 patients with pure mitral regurgitation greater than grade III. All patients had an ejection fraction of 40% or more. Patients with congenital heart disease or other valvular heart disease were excluded from this study. They were divided into two groups; the commercial ring group (Group CR) and the Teflon felt ring group (Group TF). Result: There was no mortality. The postoperative echocardiography showed no significant change in the overall ejection fraction (from $58.0{\pm}11.2%\;to\;42.8{\pm}8.4%$). There were no significant differences between the two groups with regard to morbidity, the reoperation rate and recurrence of mitral regurgitation greater than grade II. Conclusion: The long term results from this study showed that posterior mitral annuloplasty using Teflon felt had similar results compared to annuloplasty using commercial rings.